 共查询到20条相似文献,搜索用时 15 毫秒
1.
A novel effective co-reactant for electrogenerated chemiluminescence (ECL) of Ru(bpy)(3)(2+) has been found. Alpha-position-dialkylated thiophene derivatives such as 2,5-dimethylthiophene (DMT) could be used as a co-reactant for Ru(bpy)(3)(2+) ECL. The reaction mechanism of the Ru(bpy)(3)(2+)/DMT system was proposed on the basis of the identification of the reaction product, the relationship between the molecular structure and the chemiluminescent intensity, and the electrochemical study. The obtained reaction mechanism was similar to that of the Ru(bpy)(3)(2+)/aliphatic tertiary amine system. Based on these results, the preliminary studies of the Ru(bpy)(3)(2+) ECL detection system using DMT as a co-reactant were performed. Under the optimal ECL conditions, the plot of ECL intensity versus the concentration of Ru(bpy)(3)(2+) was linear over the concentration range 1.0x10(-8) to 1.5x10(-7) M (determination coefficient=0.9996).  相似文献   

2.
The electrochemiluminescence (ECL) of magnetic microbeads modified with tris(2,2'-bipyridine)ruthenium(II) ([Ru(bpy)3]2+) was studied in the presence of tri-n-propylamine (TPA) to develop highly sensitive ECL detection system, where the employed microbead has a diameter of 4.5 microm. The ECL signal of the [Ru(bpy)3]2+ derivative-modified magnetic microbeads was found to be affected by the geometrical distribution of the magnetic microbeads on the electrode surface. The ECL peak intensity increased with increasing the number of the beads on the electrode surfaces up to 1.6 x 10(6) beads cm(-2), although above 1.6 x 10(6) beads cm(-2), it decreased. The ECL decrease arises from the physical prevention of the ECL from reaching the photomultiplier tube by the excessive beads. The observed peak ECL signal of the [Ru(bpy)3]2+ derivative-modified magnetic microbeads in the presence of NaN3, which serves as a preservative substance, mainly appeared at a potential of +0.90 V vs Ag/AgCl where [Ru(bpy)3]2+ is hardly oxidized, whereas the ECL signal in the absence of NaN3 appeared at a potential of +1.15 V. The presence of NaN3 on the electrode surface retards formation of an oxide layer on the electrode surfaces and promotes TPA oxidation. The ECL response at +0.90 V was mainly attributed to ECL reaction of excited-state [Ru(bpy)3]2+* formed by oxidation of [Ru(bpy)3]+ with TPA radical cation, where the [Ru(bpy)3]+ was generated by reduction of [Ru(bpy)3]2+ with TPA radical.  相似文献   

3.
Lu X  Wang H  Du J  Huang B  Liu D  Liu X  Guo H  Xue Z 《The Analyst》2012,137(6):1416-1420
Electrochemiluminescence (ECL) of Ru(bpy)(3)(2+) using metabolites of catecholamines: homovanillic acid (HVA) and vanillylmandelic acid (VMA) as co-reactants were investigated in aqueous solution for the first time. When HVA and VMA were co-existent in the buffer solution containing Ru(bpy)(3)(2+), ECL peaks were observed at a potential corresponding to the oxidation of Ru(bpy)(3)(2+), and the ECL intensity was increased noticeably when the concentrations of HVA and VMA were at lower levels. The linear calibration range was from 8.0 × 10(-5) to 1.0 × 10(-9) M for HVA and VMA. The detection limit (S/N = 3) of HVA and VMA was 4.0 × 10(-10) M. The formation of the excited state Ru(bpy)(3)(2+*) was confirmed to result from the reaction between Ru(bpy)(3)(3+) and the intermediates of HVA or VMA radicals. Moreover, it was found that the ECL intensity was quenched significantly when the concentrations of HVA and VMA were relatively higher. The mechanism of self-quenching processes involved in the Ru(bpy)(3)(2+)-HVA and -VMA ECL systems are proposed in this study.  相似文献   

4.
This paper reports a novel detection method for DNA hybridization based on the electrochemiluminescence (ECL) of Ru(bpy)(3)(2+) with a DNA-binding intercalator as a reductant of Ru(bpy)(3)(3+). Some ECL-inducible intercalators have been screened in this study using electrochemical methods combined with a chemiluminescent technique. The double-stranded DNA intercalated by doxorubicin, daunorubicin, or 4',6-diamidino-2-phenylindole (DAPI) shows a good ECL with Ru(bpy)(3)(2+) at +1.19 V (versus Ag/AgCl), while the non-intercalated single-stranded DNA does not. In order to stabilize the self-assembled DNA molecules during ECL reaction, we constructed the ECL DNA biosensor separating the ECL working electrode with an immobilized DNA probe. A gold electrode array on a plastic plate was assembled with a thru-hole array where oligonucleotide probes were immobilized in the side wall of thru-hole array. The fabricated ECL DNA biosensor was used to detect several pathogens using ECL technique. A good specificity of single point mutations for hepatitis disease was obtained by using the DAPI-intercalated Ru(bpy)(3)(2+) ECL.  相似文献   

5.
Lu X  Liu D  Du J  Wang H  Xue Z  Liu X  Zhou X 《The Analyst》2012,137(3):588-594
The novel phenomenon of cathodic electrochemiluminescence on a gold electrode in tris(bipyridine) ruthenium(II) (Ru(bpy)(3)(2+)) solution is described for the first time. A cathodic electrochemiluminescence (ECL) was found to mainly occur at 0.4-0.8 V with continuous potential scanning from 0.2-1.4 V and the ECL peak was observed around 0.68 V, which was quite different from generally reported Ru(bpy)(3)(2+) ECL. Our group speculated that Ru(bpy)(3)(2+) possibly reacts with the gold electrode in the acidic phosphate buffer solution (PBS) to generate luminescence. The possible ECL mechanism was discussed according to the presented results. Moreover, it is revealed that the Au as co-reactant in the Ru-system contributed dominantly to the whole ECL. Therefore, the reaction between Ru(bpy)(3)(2+) and the newly formed Au implied that the inert metal Au could become a promising material for ECL investigations.  相似文献   

6.
It was found that stannous chloride (SnCl(2)), as a popular inorganic reducing reagent, could obviously enhance the electrochemiluminescence (ECL) of tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+)) in aqueous solution. Some factors affecting the ECL reactions between Ru(bpy)(3)(2+) and Sn(2+), including pH, concentrations of coreactant, and electrode materials, were investigated by comparison with a classic ECL coreactant tripropylamine (TPA). The Ru(bpy)(3)(2+)-Sn(2+) ECL coreactant system produces stronger and more stable ECL signals, can keep its excellent ECL activity over a wider pH range and has more choices in using electrode materials than the Ru(bpy)(3)(2+)-TPA ECL coreactant system. The ECL mechanism of the Ru(bpy)(3)(2+)-Sn(2+) coreactant system was also studied in detail.  相似文献   

7.
Bruce D  McCall J  Richter MM 《The Analyst》2002,127(1):125-128
The effects of electron withdrawing and electron donating groups on the electrochemiluminescent (ECL) properties of tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+) where bpy = 2,2'-pyridine) are reported. The electrochemistry, photophysics and ECL of (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ (DC = 4,4'-dicarboxy-2,2'-bipyridine; DM = 4,4'-dimethyl-2,2'-bipyridine) have been studied relative to Ru(bpy)3(2+) in 50:50 (v/v) acetonitrile(CH3CN):H2O (0.1 M KH2PO4), and aqueous solutions. Furthermore, the effects of Triton X-100 (polyethylene glycol tert-octylphenyl ether) on the electrochemical, spectroscopic and ECL properties of these compounds are reported. The anodic oxidation of Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ produces ECL in the presence of tri-n-propylamine (TPrA) in all solvent systems. ECL efficiencies (phi(ecl), photons produced per redox event) of 0.73 and 0.84 for (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+ were obtained in aqueous buffered solution, using Ru(bpy)3(2+) as a relative standard (phi(ecl) = 1.0). Addition of 0.4 mM Triton X-100 results in a greater than 2-fold increase in ECL efficiences (i.e., 3.8, 2.4 and 2.3 for Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+, respectively) using aqueous Ru(bpy)3(2+) containing no surfactant as standard (phi(ecl) = 1.0). ECL efficiencies of 27.4, 16.5 and 26.1 were found in 50:50 (v/v) CH3CN:H2O (0.1 M KH2PO4) for Ru(bpy)3(2+), (bpy)2Ru(DC-bpy)2+, and (bpy)2Ru(DM-bpy)2+, respectively, using aqueous Ru(bpy)3(2+) containing no surfactant as standard (phi(ecl) = 1.0). Detailed studies support adsorption of surfactant on the electrode surface, thus facilitating TPrA and ruthenium oxidation.  相似文献   

8.
Guo W  Yuan J  Li B  Du Y  Ying E  Wang E 《The Analyst》2008,133(9):1209-1213
A unique multilabeling at a single-site protocol of the Ru(bpy)(3)(2+) electrochemiluminescence (ECL) system is proposed. Nanoparticles (NPs) were used as assembly substrates to enrich ECL co-reactants of Ru(bpy)(3)(2+) to construct nanoscale-enhanced ECL labels. Two different kinds of NP substrates [including semiconductor NPs (CdTe) and noble metal NPs (gold)] capped with 2-(dimethylamino)ethanethiol (DMAET) [a tertiary amine derivative which is believed to be one of the most efficient of co-reactants of the Ru(bpy)(3)(2+) system] were synthesized through a simple one-pot synthesis method in aqueous media. Although both CdTe and gold NPs realized the enrichment of ECL co-reactants, they presented entirely different ECL performances as nanoscale ECL co-reactants of Ru(bpy)(3)(2+). The different effects of these two NPs on the ECL of Ru(bpy)(3)(2+) were studied. DMAET-capped CdTe NPs showed enormous signal amplification of Ru(bpy)(3)(2+) ECL, whereas DMAET-capped gold NPs showed a slight quenching effect of the ECL signal. DMAET-capped CdTe NPs can be considered to be excellent nanoscale ECL labels of the Ru(bpy)(3)(2+) system, as even a NP solution sample of 10(-18) M was still detectable after an electrostatic self-assembly concentration process. DMAET-capped CdTe NPs were further applied in the construction of aptamer-based biosensing system for proteins and encouraging results were obtained.  相似文献   

9.
Qiu H  Yin XB  Yan J  Zhao X  Yang X  Wang E 《Electrophoresis》2005,26(3):687-693
A simultaneous electrochemical (EC) and electrochemiluminescence (ECL) detection scheme was introduced to both microchip and conventional capillary electrophoresis (CE). In this dual detection scheme, tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)3(2+)) was used as an ECL reagent as well as a catalyst (in the formation of Ru(bpy)3(3+)) for the EC detection. In the Ru(bpy)3(2+)-ECL process, Ru(bpy)3(3+) was generated and then reacted with analytes resulting in an ECL emission and a great current enhancement in EC detection due to the catalysis of Ru(bpy)3(3+). The current response and ECL signals were monitored simultaneously. In the experiments, dopamine and three kinds of pharmaceuticals, anisodamine, ofloxacin, and lidocaine, were selected to validate this dual detection strategy. Typically, for the EC detection of dopamine with the presence of Ru(bpy)3(2+), a approximately 5 times higher signal-to-noise ratio (S/N) can be achieved than that without Ru(bpy)3(2+), during the simultaneous EC and ECL detection of a mixture of dopamine and lidocaine using CE separation. The results indicated that this dual EC and ECL detection strategy could provide a simple and convenient detection method for analysis of more kinds of analytes in CE separation than the single EC or ECL detection alone, and more information of analytes could be achieved in analytical applications simultaneously.  相似文献   

10.
Ru(bpy) 3 2+ electrogenerated chemiluminescence (CL) has rapidly gained importance as a sensitive and selective detection method in analytical science. The Ru(bpy) 3 2+ ECL is observed when Ru(bpy) 3 3+ reacts with Ru(bpy) 3 + and yields an excited state Ru(bpy) 3 2+* . ECL emission can also be obtained when a variety of oxidants and reductants react with the reduced or oxidized forms of Ru(bpy) 3 2+ . Either the reductant or the oxidant can be treated as an analyte. The Ru(bpy) 3 2+ ECL is used as a detection method for the determination of oxalate and a variety of amine-containing analytes without derivatization in flowing streams such as flow injection and HPLC. When the ECL format is used as a detector for HPLC, unstable post-column reagent addition can often be eliminated and, the problems of both sample dilution and band broadening can be avoided because the Ru(bpy) 3 3+ species are generatedin situ in the reaction/observation flow cell. Since NADH is sensitively detected with the Ru(bpy) 3 2+ ECL, many clinically important analytes can be detected by coupling them to dehydrogenase enzymes that utilize -nicotinamide adenine cofactors to convert NAD+ to NADH. Ru(bpy) 3 2+ -derivatives are used as CL labels for immunoassay and PCR assay with Ru(bpy) 3 2+ /tripropylamine ECL system. The Ru(bpy) 3 2+ ECL label can be sensitively determined at subpicomolar concentrations, along with an extremely wide dynamic range of greater than six orders of magnitude. Furthermore, it can eliminate disposal and lifetime problems inherent in radio immunoassays. In this paper, basic principles of the Ru(bpy) 3 2+ ECL are discussed. In addition, analytical applications of the Ru(bpy) 3 2+ ECL are illustrated with examples.  相似文献   

11.
Several [Ru(bpy)3]2+ (bpy = 2,2'-bipyridine and its derivatives) complexes were synthesized and compared electrochemically and spectroscopically in the search for better luminophores for electrochemiluminescence (ECL)-based analytical applications. ECL measurement in [Ru(bpy)3]2+/tripropylamine (TPA) aqueous buffer solutions has led to a conclusion that due to the complexity of the ECL generation process, the photoluminescence efficiency cannot be used to predict ECL intensity and there is no obvious relationship between the photoluminescence quantum yield and the ECL intensity. Under the present experimental condition, when compared with the pristine [Ru(bpy)3]2+, the ethoxycarbonyl-substituted derivative, [Ru(bpy-COOEt)3]2+, one of the most efficient luminophores under photoexcitation, did not generate reasonably intense ECL, whereas luminophores with lower photoluminescence quantum yields demonstrated higher ECL. These findings are useful for further efforts in the search for more efficient ECL luminophores.  相似文献   

12.
陶颖  李梅金  章丽燕  陈曦 《化学学报》2006,64(18):1885-1888
在玻碳电极上, 联吡啶钌[Ru(bpy)32+]于+1.50 V (vs. Ag/AgCl)左右被氧化为Ru(bpy)33+, 该氧化态离子与碱性水溶液中(pH 8.2)的OH•反应生成激发态的[Ru(bpy)32+*]而发光. 研究比较了15种金属离子对Ru(bpy)32+碱性水溶液电致化学发光的影响, 并对这些影响进行了初步的解释.  相似文献   

13.
We describe the influence of dissolved oxygen on the emission of Ru(bpy)3(2+) (bpy = 2,2'-bipyridine) by electrogenerated chemiluminescence (ECL) with tertiary amine as coreactant in aqueous solutions. The significance of the reactions between molecular oxygen and the ECL intermediate reducing radicals has been demonstrated for the first time. By varying the experimental conditions, the oxygen effect on different ECL routes of the Ru(bpy)3(2+)/tri-n-propylamine (TPrA) system was examined. When coreactant direct oxidation played a predominant role in producing ECL, the maximum emission intensity, especially that of the low-oxidation-potential (LOP) ECL, could change from O2-insensitive to highly O2-sensitive with decreasing TPrA concentration. This behavior can be interpreted as follows: A large excess of intermediate reducing radicals was produced at high [TPrA], and the dissolved oxygen within the ECL reaction layer was completely reduced by these radicals and exerted no quenching effect on the emission. At low [TPrA], however, coreactant oxidation generated a relatively small amount of reducing intermediates, and molecular oxygen acted as an interceptor, destroying the intermediates before they participated in the ECL pathways, which led to the obvious reduction of the emission intensity. In the latter case, the less efficient LOP ECL route was more remarkably affected. When ECL was generated primarily via the catalytic route at high [Ru(bpy)3(2+)], the reactions consuming the intermediate radicals by O2 became insignificant, and he drop of emission intensity in the presence of oxygen could mainly be ascribed to the excited-state quenching. A similar oxygen effect was also observed for the Ru(bpy)3(2+)/triethylamine (TEA) system.  相似文献   

14.
Wang J  Yang Z  Wang X  Yang N 《Talanta》2008,76(1):85-90
Tris(2,2'-bipyridyl) ruthenium(II) (Ru(bpy)(3)(2+))-roxithromycin based electrochemiluminescence (ECL) was enhanced greatly by gold nanoparticles 10 nm in diameter. Capillary electrophoresis (CE) was coupled with the resultant ECL system as a detector for roxithromycin. This ECL emission is explained by the coreactant mechanism where roxithromycin behaves as a coreactant to generate strong reducing species and gold nanoparticles act as "floating nanoelectrodes". The reaction of Ru(bpy)(3)(3+) with the generated strong reducing species on the Pt working electrode as well as on "floating nanoelectrodes" releases Ru(bpy)(3)(2+*), resulting in enhancement of ECL emission. The selectivity of this detection system towards roxithromycin was examined by CE. Under the optimized conditions, the intensity of ECL emission varies linearly with the concentration of roxithromycin from 24 nM to 0.24 mM. The detection limit is 8.4 nM, while without adding gold nanoparticles it is only 84 nM. The detection of roxithromycin in pharmaceutical and urine samples was also performed by the proposed CE-ECL method.  相似文献   

15.
One solid-state electrochemiluminescence(ECL) protein biosensor based on the competing reaction and substitute reaction between protein-to-DNA aptamer and DNA-to-DNA aptamer was proposed.Additionally,the biosensor was based on ECL photo-quenching effect of ferrocene(Fc) to tris(2,2'-bipyridyl)ruthenium(II)(Ru(bpy)32+).It was built up by modification of Au nanoparticles(AuNPs) and Ru(bpy)3 2+ on one Au electrode firstly,and then self-assembly of one special double-stranded DNA(dsDNA) onto the electrode.This ...  相似文献   

16.
The electrogenerated chemiluminescence (ECL) of the Ru(bpy)32+ (bpy, 2,2′-bipyridine)/tri-n-propylamine (TPrA) system can be produced at an oxidation-potential well before the oxidation of Ru(bpy)32+. Here, we describe the unique features of the low-oxidation-potential (LOP) ECL. The LOP ECL exhibited strong dependence on solution pH with the maximum emission at pH  7.7. Compared with the conventional ECL, the LOP ECL was much more significantly diminished at high pH (>10), probably due to the short lifetime of TPrA cation radical which is a crucial intermediate for the LOP emission. It was also found that the preceding deprotonation step played an important role in TPrA oxidation at neutral pH and would remarkably influence the emission intensity. As excess intermediate radicals were produced upon rapid TPrA oxidation, only 5 mM TPrA was needed to achieve the maximum LOP ECL intensity in detecting trace Ru(bpy)32+ (<1 μM) and the LOP ECL response to Ru(bpy)32+ concentration was linear. Compared with the conventional Ru(bpy)32+/TPrA ECL, the LOP ECL technique not only produces higher emission intensity at lower oxidation-potential, but also significantly reduces the amount of the coreactant.  相似文献   

17.
赵丽  陶颖  陈曦 《化学学报》2006,64(4):320-324
通过电化学循环伏安法和电致化学发光方法,研究了Ru(bpy)32 在玻碳电极上的吸附,研究结果表明,2Ru(bpy)3 的浓度和与玻碳材料接触的时间,直接影响了Ru(bpy)32 在玻碳上的吸附.还考察了吸附的Ru(bpy)32 在玻碳电极上被氧化后脱附的情况.  相似文献   

18.
In this paper, we describe the electrochemiluminescent (ECL) behavior of Ru(bpy)33+-incorporated clay colloids. Experimental results based on the electrochemical-quartz-crystal-microbalance (EQCM) techniques showed that Ru(bpy)33+ could be adsorbed by the clay colloids (montmorillonite K10, denoted K10). The resulting clay particles could emit light (λem 610 nm) when they were fabricated as thin films sandwiched by two conductive ITO electrodes with opposite biases. These Ru(bpy)33+-incorporated clay-modified electrodes could also emit light in aqueous oxalate solutions (pH 10) when potentials more positive than 0.9 V vs. SCE were applied. EDTA was an effective promoter for the Ru(bpy)3 (clay)3+-oxalate ECL reaction. The resulting ECL showed a remarkable sensitivity to oxygen. A glucose optrode was thus fabricated based on the Ru(bpy)33+-incorporated K10 colloids and glucose oxidase (GOx). The ECL signals behaved as a function of [glucose], covering a range from 0.1 to 10 mM at pH 10. The detection limits reached a level of 0.1 mM at this pH.  相似文献   

19.
Bifunctional nanoarchitecture has been developed by combining the magnetic iron oxide and the luminescent Ru(bpy)32+ encapsulated in silica. First, the iron oxide nanoparticles were synthesized and coated with silica, which was used to isolate the magnetic nanoparticles from the outer-shell encapsulated Ru(bpy)32+ to prevent luminescence quenching. Then onto this core an outer shell of silica containing encapsulated Ru(bpy)32+ was grown through the St?ber method. Highly luminescent Ru(bpy)32+ serves as a luminescent marker, while magnetic Fe3O4 nanoparticles allow external manipulation by a magnetic field. Since Ru(bpy)32+ is a typical electrochemiluminescence (ECL) reagent and it could still maintain such property when encapsulated in the bifunctional nanoparticle, we explored the feasibility of applying the as-prepared nanostructure to fabricating an ECL sensor; such method is simple and effective. We applied the prepared ECL sensor not only to the typical Ru(bpy)32+ co-reactant tripropylamine (TPA), but also to the practically important polyamines. Consequently, the ECL sensor shows a wide linear range, high sensitivity, and good stability.  相似文献   

20.
石鑫  王捷  刘仲明 《化学研究》2010,21(4):92-95
本文简要介绍了毛细管电泳Ru(bpy)32+电化学发光的基本特性,概述了其在与复合材料和微控芯片结合应用时的研究进展,就近几年来的报道,综述了毛细管电泳Ru(bpy)32+电化学发光在药物分析,食品分析,生命科学领域的应用,并对毛细管电泳Ru(bpy)32+电化学发光的前景进行了展望.  相似文献   