首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Sulphathiazole in the presence of sulphametazine is determined by a method based on derivative solid-phase spectrophotometry. Both compounds are fixed on a dextran-type cation-exchange gel. The absorbance of the gel, packed in a 1-mm silica cell, is measured directly. The range of application is between 0.20 and 18.0 g/ml of sulphathiazole in the presence of up to 20 g/ml of sulphametazine, the relative standard deviation is 0.6% and the detection limit is 0.05 g/ml. The method has been applied to the determination of sulphathiazole in synthetic mixtures and pharmaceuticals, with recoveries of 95.0 to 102.5%  相似文献   

2.
    
Zusammenfassung 2-Thiobarbitursäure wird zum Nachweis und zur Bestimmung von Fe(III) verwendet. Im Reagensglas kann noch 1 g Fe(III)/ml nachgewiesen werden. Eine größere Empfindlichkeit (0,2 g/ml) wird bei Anwendung eines mit Thiobarbitursäurelösung getränkten Papiers erreicht. Die photometrische Bestimmung ist im Konzentrationsbereich 4–40 g/ml mit einem Fehler von höchstens ±0,5 g möglich.
Summary 2-Thiobarbituric acid is recommended for the detection and determination of trivalent iron. In the test tube 1 g of Fe(III)/ml can be detected, whereas this limit can be reduced to 0.2 g of Fe(III)/ml by use of paper impregnated with the reagent. The photometric determination is possible within the range of 4–40 g of Fe(III)/ml with an error of not more than ±0.5 g.
  相似文献   

3.
Zusammenfassung Ein schnelles und einfaches Mikroverfahren zum Nachweis einiger Heteroatome organischer Verbindungen wurde entwickelt. Nach Aufschluß mit metallischem Kalium werden die entstehenden Ionen mit der Ringofenmethode getrennt und mit empfindlichen Reaktionen nachgewiesen. Nachweisgrenze: 0,5 bis 1g Stickstoff, 1 bis 2g Schwefel, 2 bis 3g Jod, 4 bis 5g Brom, 5 bis 10g Chlor in 0,5 bis 1 mg Einwaage.
Summary A rapid and simple micromethod was developed for the detection of several hetero-elements in organic compounds. After breaking down the sample with metallic potassium, the resulting ions are separated by the ring oven method and detected by means of sensitive reagents. Detection limits: 0.5 to 1g nitrogen, 1 to 2g sulfur, 2 to 3g iodine, 4 to 5g bromine, 5 to 10g chlorine in samples weighing 0.5 to 1 mg.

Résumé On a découvert un procédé à l'échelle micro, simple et rapide, pour rechercher certains hétéroéléments dans les composés organiques. Après mise en solution par le potassium métallique, on sépare les ions formés suivant la méthode du four annulaire et l'on effectue la recherche au moyen de réactions sensibles. Limite de dilution: 0,5 à 1g d'azote, 1 àg de soufre, 2 àg d'iode, 5 à 10g de chlore sur 0,5 à 1 mg de prise d'essai.
  相似文献   

4.
The characteristics of knitted open tube (KOT) figure eight reactors and coil reactors at l/min flow rates were compared using plate height (H) calculations and peak height measurements. Peak broadening independent of flow rate was seen for the figure eight KOT but not the coil at flow rates of 150–300 l/min. Below 150 /min, the plate height values of both reactors were inversely proportional to flow rate. It was concluded that a 0.5-m KOT figure eight reactor is the most effective way to introduce delay time for a 1 1 injection size and tubing of 0.3 mm I.D. Enhancement of peak height response was particularly pronounced at flow rates less than 100 l/min.  相似文献   

5.
The effect of cationic surfactants (cetyltrimethylammonium bromide, cetylpyridinium bromide, and tetrabutylammonium perchlorate) and a nonionic surfactant (OP-7) on the conditions of the immobilization of 4-(2-pyridylazo)resorcinol (PAR) on three types of silica gel (Silochrom S-120 (200–350 m), Silochrom S-120 (315–500 m), and Silochrom S-80 (200–350 m)) was studied. It was found that OP-7 does not affect the adsorption of surfactants. The effect of cationic surfactants increases in the order tetrabutylammonium perchlorate < cetyltrimethylammonium bromide < cetylpyridinium bromide. The adsorption activity of silica gels increases in the order Silochrom S-120 (315–500 m) < Silochrom S-80 (200–350 m) < Silochrom S-120 (200–350 m). Cetylpyridinium bromide provides full immobilization of PAR on silica gel Silochrom S-120 (200–350 m) in the pH range 2–9.  相似文献   

6.
The absorption spectra of 4f electron transitions of the systems of neodymium and erbium with 2-isobutylformyl-1,3-dione-indane and TX-100 have been studied by normal and derivative spectrophotometry. Their molar absorptivities at the maximum absorption bands are about 7.2 (at 571 nm) times greater for neodymium and 13.1 (at 519 nm) times greater for erbium than those in the absence of the complexing agents. Use of second derivative spectra both eliminates the interference from other rare earths and increases the sensitivity from neodymium and erbium. Beers law is obeyed from 020 g/ml for neodymium and 025 g/ml for erbium. The relative standard deviations are 1.2% and 1.6% for 5.0 g/ml of neodymium and 8.0 g/ml of erbium, respectively. The detection limits (signal-to-noise ratio=2) are 0.14 g/ml and 0.20 g/ml. A method for the direct determination of neodymium and erbium in rare earth mixtures with good accuracy and selectivity is proposed.  相似文献   

7.
The reaction of the tetranuclear trimethylacetate complex Co4(3-OH)2(-OOCCMe3)4(2-OOCCMe3)2(EtOH)6 with pyridine in acetonitrile was studied. Two new compounds, viz., the hexanuclear cobalt(ii) complex Co6py4(3-OH)2(-OOCCMe3)10 (25% yield) and the unusual ionic compound [Co3py3(3-O)(-OOCCMe3)6]+[Co4py(4-O)(-OOCCMe3)7] (5% yield), were prepared. The structures of the new compounds were established by X-ray diffraction analysis.  相似文献   

8.
New homopolynuclear nickel(II) xanthate complexes with nitrogen donor heterocycles as bridging ligands have been prepared, namely [Ni(Rxa)2(-L)]n and [Ni2(Rxa)4(-L1)], where R=i-Pr,i-Am; xa=OCS2– L=1,2-bis(4- pyridyl)ethane (bpe), 4,4-dithiodipyridyl (dtp), 1,2-bis(4- pyridyl)ethylene (dpe), 4,4-trimethylene-dipyridine (tmd); L1=2,3-bis(2-pyridyl)pyrazine (bpp), 2,4-bis(5,6- diphenyl-1,2,4-triazine-3-yl)pyridine (bdt), or 2,4,6-tris(2- pyridyl)-1,3,5-triazine (tpt). The compounds have been characterized by elemental analyses, i.r. and electronic spectroscopies, magnetochemical and conductivity measurements. The results show that the [Ni(Rxa)2(-L)]n complexes are linear polymers in which the nitrogen heterocycles bridge between the nickel(II) ions, which are coordinated by four sulfur and two nitrogen atoms and have trans-octahedral geometry. The nearly constant values of the effective magnetic moment (3.36–3.34 eff/B) over the 77–295 K temperature range indicate that exchange interactions are lacking among the paramagnetic centres in the linear structure, [Ni(i-Amxa)2(dpe)]n. The variable- temperature magnetic susceptibilities of the [Ni2(i-Prxa)4(bpp)] (3.00–2.95eff/B per Ni atom), [Ni2(i-Prxa)4(bdt)] (2.72–2.63 eff/B per Ni atom), and [Ni2(i-Amxa)4(tpt)] (2.76–1.87 eff/B per Ni atom) were measured down to liquid nitrogen temperature. In the case of binuclear nickel(II) complexes with bdt or tpt, antiferromagnetic coupling between the nickel(II) ions was detected, giving the exchange integral J=–4.0cm–1 and –29.6cm–1, respectively.  相似文献   

9.
Summary Spots of citrinin, ochratoxin A, aflatoxin M1 and penicillic acid on thin-layer chromatograms can be semi-quantitatively estimated by using a grey scale, commonly used in photo laboratories. The detection limits are 0.01 g for citrinin, 0.006 g for ochratoxin A, 0.002 g for aflatoxin M1 and 0.01 g for penicillic acid. Standard curves for these mycotoxins are given.
Halbquantitative Bestimmung der Mycotoxine Citrinin, Ochratoxin A, Aflatoxin M1 und Penicillinsäure auf Dünnschicht-Chromatogrammen mit Hilfe eines Graukeils
Zusammenfassung Mit Hilfe eines in Photolabors gebräuchlichen Graukeils können dünnschicht-chromatographische Flecke der obengenannten Mycotoxine halbquantitativ bestimmt werden. Die Nachweisgrenzen betragen 0,01 g für Citrinin, 0,006 g für Ochratoxin A, 0,002 g für Aflatoxin M1 und 0,01 g für Penicillinsäure. Eichkurven werden angegeben.
  相似文献   

10.
In current textbooks fugacity is introduced according to its differential or integral mathematical formulation. In this article an alternative method of explanation is offered. It is suggested that the real state of a pure gas can be described by comparing it to a hypothetical idealized state. The differences between these two states can then be expressed in terms of a function, , defined as (T,P) = real(T,P) - ideal(T,P) where real and ideal are the chemical potentials of the gas in its real and ideal states, respectively. The function is a molar excess quantity and is expressed as (T,P) = RT1n where is the fugacity coefficient. This approach introduces fugacity deductively through the function, which leads to , the fugacity coefficient. This method is also appropriate for introducing the activity of solution components and the fugacity of a real gas in gaseous mixtures.  相似文献   

11.
Polypyrrole (PPy) was electrochemically synthesized on stainless steel frits as a sorbent for the micro solid phase extraction (SPE) of ochratoxin A (OTA). Using 20 l of standard solution under a fast flow rate of 0.5 ml/min, 80% recovery of OTA was achieved in the concentration range from 0.1–10 pg/l. This good recovery was achieved within a short residence time of 1.2 s. A binding capacity of 1 ng OTA was estimated for each PPy-modified frit, or 2 ng OTA for two frits in series. The bound OTA could be pulsed eluted (PE) with 20 l of 1% triethylamine in acetonitrile. On-line coupling of this PPy-on-a-frit and PE technique to high performance liquid chromatography (HPLC) was straightforward. On-line SPE-PE-HPLC results clearly demonstrated the capability of PPy-on-a-frit to bind OTA in the presence of red wine, beer, and orange juice components.  相似文献   

12.
The discharge of thin films of Li x V2O5 is described by a mathematical diffusion model. The chemical diffusion coefficient for lithium ions, estimated with the model, is equal to (1.01–2.5) × 10–11 cm2/s. As the film thickness increases, the discharge capacity at a current of 20 A/cm2 tends to the calculated limiting of 3.12 C/cm2. The optimum thickness of the film electrode calculated for a discharge current of 20 A/cm2 is 33.4 m and agrees satisfactorily with the experimental value.  相似文献   

13.
Summary Laser microprobe mass analysis (LAMMA) was applied to characterize aerosol particles collected and separated from 16m to 0.06m by a low pressure cascade impactor. Positive ion LAMMA spectra showed characteristic molecular peaks such as PbCl+, a series of Si2O+–Si2O4 + and NaAl2Si2O2 +–NaAl2Si2O5 +, and TiO+ in 0.06–0.12m, 0.5–1m and 4–8m fraction, respectively. In the negative ion LAMMA spectra, it was observed that the fragment peaks of sulfate ions were deficient above 2m and those of nitrate ions were deficient under 2m. LAMMA allows remarkable insights into the chemical nature of aerosol particles.
Charakterisierung luftgetragener Teilchen durch Laser-Microprobe-Massenspektrometrie
Zusammenfassung Laser-Microprobe-Spektrometrie (LAMMS) wurde zur Analyse atmosphärischen Aerosols herangezogen, welches im Korngrößenbereich zwischen 16m und 0.06m mit einem Niederdruckkaskadenimpaktor fraktioniert gesammelt wurde. Positive LAMMS-Spektren zeigten charakteristische molekulare Peaks, wie etwa PbCl+, eine Serie von Si2O+–Si2O4 + und NaAl2Si2O2 +–NaAl2Si2O5 +, sowie TiO+ in der 0,06–0,12-m,- 0,5–1–m- bzw. 4–8-m-Fraktion. In den negativen LAMMS-Spektren konnten über 2m keine Fragmentpeaks für Sulfationen, unter 2m. keine für Nitrationen beobachtet werden. LAMMS ermöglicht eine bemerkenswerte Einsicht in die chemische Natur von Aerosolteilchen.
  相似文献   

14.
By using the coincident measurement, an ERD method has been established and used for hydrogen profiling in thin foils. In the present study, 6 MeV has been used as incident particle, the scattered and the recoiled proton from one collision were coincidentally detected at 150 (proton) and 173.9 (). This method has been used for hydrogen profiling of 5.6 m Mylar and 8.6 m aluminium foils. Because of the coincident measurement, the background is largely reduced, and its minimum detection limit is about 0.5% (atomic), lower than the conventional ERD method. The measured depth resolution in 5.6 m Mylar is 0.6 m. It is possible to use this method for hydrogen profiling in thin foils of several micron thickness.  相似文献   

15.
First- and second-derivative spectrophoto-metric methods for the simultaneous determination of aluminium and iron in their mixtures are described. The methods are based on the colored complexes formed by aluminium and iron with hematoxylin in the presence of cetyltrimethylammonium bromide as a surfactant. The zero-crossing method has been utilized to measure the first- and second-derivative value of the derivative spectrum. Aluminium (0.05–1 gml-1) could be determined in the presence of iron (0.09–1.6 gml-1) and vice versa. The detection limits of aluminium and iron are 0.01 and 0.09 gml-1, respectively in the first-derivative mode and 0.014 and 0.1 gml-1 in the second-derivative mode. The proposed method has been applied to the simultaneous determination of aluminium and iron in glasses, phosphate rocks, cement and magnesite alloy.  相似文献   

16.
The absorption spectra of 4f electron transitions of the neodymium and erbium complexes with benzoyl-indan-1,3-dione and cetylpyridinium chloride have been studied by conventional and derivative spectrophotometry. The second-derivative spectrum has been used to eliminate the interference of the other lanthanides, and to increase the sensitivity by a further factor of 4–6. Beer's Law is obeyed for 6–29 g/ml Nd and 7–33 g/ml Er. The relative standard deviations evaluated from 10 independent determinations of 5.0 g/ml Nd and Er were 1.1% (Nd) and 1.6% (Er). The detection limits obtained from the sensitivity of the calibration graphs and 3s b, (standard deviation of the blank,n = 11) were 0.63 g/ml Nd and 0.61 g/ml Er. The quantification limits (10s b) were 2.1 g/ml Nd and 2.0 g/ml Er. A method for the direct determination of neodymium and erbium in rare earth mixtures with good accuracy and selectivity is proposed.  相似文献   

17.
Summary Aspects of cracking and joining capillaries have been investigated. Capillary coupling was achieved using various methods. The most successful used hydrofluoric acid-etched capillaries to form male and female ends which were then joined together. This type of joint was used to connect sections of capillary of similar and different internal diameters with minimal loss in resolution, peak width and number of theoretical plates. (Uridine and hypoxanthine was used as a test mixture). For hypoxanthine on a 50 m/50 m etched joined capillary 10 cm from the detector window the number of theoretical plates was 96.6% of that for hypoxanthine on an unbroken capillary. Following the relative success of capillary joining, a coupled capillary flowcell (50 m/200 m) was produced and evaluated.  相似文献   

18.
A first-order derivative spectrophotometric method has been developed for the simultaneous determination of copper, mercury and lead at g/L levels using dithizone as reagent. The procedure involves the simultaneous extraction of these elements by dithizone in chloroform from weakly alkaline solutions. Linear calibration curves were obtained in the ranges 0.5–10 (Cu), 1–10 (Hg) and 1–10 (Pb) g present in 40 ml of aqueous phase with detection limits of 5 g/L (Cu) and 20 g/L (Hg and Pb). The R.S.D.s for 100 g/L of copper, mercury and lead were 2.5, 2.6 and 3.1% respectively, for 5 determinations. The method is applicable for the determination of copper and lead in marine sediment samples with good precision and accuracy.  相似文献   

19.
    
Zusammenfassung Eine korngrößenfraktionierende Probenahme von Staub zur nachfolgenden chemischen Analyse ist in einem weiten Korngrößenbereich mit Niederdruck-Kaskadenimpaktoren möglich.Zur Probenahme von lungengängigem und atembarem Staub wurde ein 5stufiger Lochkranzstufenimpaktor, Typ TU mit einem Abscheidebereich von 0,1–25 m aerodynamischem Massenäquivalentdurchmesser herangezogen. Mit einer Sammelrate von 5 m3 h–1 werden im urbanen Bereich Aerosolfraktionen mit hoher zeitlicher Auflösung erhalten.Zur Auswertung der Massenkorngrößenverteilungsdaten von urbanen Stäuben wird das Verfahren der erzwungenen Bimodalität eingeführt, welches eine vergleichbare Darstellung von Staubverteilungsdaten, die mit verschiedenen Impaktortypen bestimmt wurden, erlaubt. Die erzwungene Bimodalität beruht auf der definitionsgemäßen Festlegung eines Minimums der Massendichteverteilung urbaner Aerosole bei 2 für solche korngrößenseparierende Probenahmeverfahren, deren Auflösung die exakte Bestimmung des Minimums nicht erlaubt. Eine Analyse von Verteilungsdaten aus verschiedenen Städten, sowie von verschiedenen Meßstellen in Wien zeigte, daß der Anteil des vom Grobteilchenkollektiv (> 2 m AD) chemisch unterschiedlichen Akkumulationsstadiums (Teilchen 2 m AD) an einem Feinstaub nach TA Luft 1974 (Teilchen 10 m AD) größeren Schwankungen unterliegen kann. Im städtischen Bereich ist der Anteil des Feinstaubes (10 m) am Gesamtstaub stark vom Verkehrsanteil an der Staubentwicklung abhängig.Zur chemischen Analyse der abgeschiedenen Teilchenfraktionen wird ein Analysenschema vorgeschlagen, das zeitlich stark variierende Staubkomponenten als Kurzcharakteristik nach 1 h Probenahmeintervall quantifiziert. Zur Erstellung der Gesamtcharakteristik des Staubes, beinhaltend die Durchschnittsanalyse der Haupt- und Nebenbestandteile, ausgewählter toxischer Spurenelemente, der Spezifizierung der Kohlenstoff-, Schwefel- und Stickstoffverbindungen sowie der Identifizierung ausgewählter organischer und anorganischer Verbindungen werden 24 h Probenahmezeit benötigt.
Sampling of respirable and lung penetrating atmospheric particles for integrated dust analysis
Summary The size-selective sampling of particles in a wide size range for chemical analysis is practicable with cascade impactors. The sampling of respirable particles is carried out with a 5-stage circular-arranged multiorifice impactor, type TU, with a deposition range of 0.1–25 m aerodynamic massequivalent diameter. A sampling rate of 5 m3 h–1 yields aerosol fractions with high temporal resolution.For the evaluation of mass-size distribution data of urban particles the concept of forced bimodality is introduced, thus obtaining comparable results from aerosol distribution data obtained with different types of impactors. Mass distribution data from several cities indicate that the portion of the accumulation mode (particles 2 m AD) within a fine particle fraction of particles < 10 m AD is subjected to considerable variations. The relation fine particles/coarse particles is strongly influenced by traffic derived particles.An analytical scheme for constituents with frequent changes in concentration (short characteristic) and for extensive characterization of the atmospheric particles is proposed. In urban regions, minimum sampling periods of 1 h are required for short and 24 h for full characterization.
  相似文献   

20.
The reaction between Ru3(3-2-PhC2C=CPh)(-dppm)(CO)8 and Co2(CO)8 afforded dark red Co2Ru3(4-C2Ph)(3-C2Ph)(-dppm)(-CO)2(CO)9, shown by an X-ray structure determination to contain a strongly twisted Co2Ru3 bow-tie cluster (central Co), to which two PhC2 units derived from cleavage of the original diyne are attached. One a these is strongly interacting with four metal atoms, the other being attached in the familiar 1,22-mode. The dppm ligand remains bridging two of the Ru atoms.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号