首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The mass fractions of Hg and methylmercury, in two certified reference materials, NIST2710 and DORM-2, have been determined by total and species-specific isotope dilution analysis (IDA), respectively, and uncertainty budgets for each analysis calculated. The mass fraction of Hg in NIST2710 was determined by ID using multicollector sector field inductively coupled plasma mass spectrometry (MC-SF-ICP-MS) whilst the mass fraction of methylmercury in DORM-2 was determined using HPLC coupled with quadrupole ICP-MS.

The extent of equilibration between the spike and the particulate bound mercury compounds was studied temporally by monitoring the 200Hg:199Hg isotope amount ratio and by determining the total amount of Hg in the liquid phase. For the NIST2710 complete equilibration was only achieved when concentrated HNO3 in combination with a microwave digestion was employed, and good agreement between the found (31.7±4.0 μg g−1, expanded uncertainty k=2) and certified (32.6±1.8 μg g−1) values was obtained. For DORM-2 complete equilibration of methylmercury between the liquid and solid phases was achieved when using 50:50 H2O:CH3OH (v/v) and 0.01% 2-mercaptoethanol as the solvent. Even though only 50% of the analyte was extracted into the liquid phase, complete equilibration was achieved, hence, the found methylmercury mass fraction (4.25±0.47 μg g−1, expanded uncertainty k=2) was in good agreement with the certified value (4.47±0.32 μg g−1).  相似文献   


2.
R.M. Callejon  A.M. Troncoso  M.L. Morales   《Talanta》2007,71(5):1610-2097
A complete methodology for the determination of chloroanisoles and chlorophenols in cork material is proposed. The determination is accomplished by means of a previous liquid–solid extraction followed by stir bar sorptive extraction (SBSE) coupled to gas chromatography–mass spectrometry (GC–MS). Two different liquid–solid extraction experiments were conducted and eight compounds considered (2,6-dichloroanisole, 2,4-dichloroanisole, 2,4,6-trichloroanisole, 2,4,6-trichlorophenol, 2,3,4,6-tetrachloroanisole, 2,3,4,6-tetrachlorophenol, pentachloroanisole and pentachlorophenol). From the results obtained we can conclude that high volume extraction extending extraction time up to 24 h is the best choice if we have to release compounds from the inner surfaces of cork stoppers. Recovery percentages ranged from 51% for pentachloroanisole to 81% for 2,4-dichloroanisole. This method allows the determination of an array of compounds involved in cork taint at very low levels from 1.2 ng g−1 for 2,4,6-tricholoroanisole to 23.03 ng g−1 for 2,3,4,6-tetrachlorophenol.  相似文献   

3.
Polystyrene–divinylbenzene (8%) has been functionalised by coupling it through an ---N=N--- group with 6-mercaptopurine. The resulting chelating resin has been characterised by using elemental analysis, thermogravimetric analysis and infrared spectra. The resin is highly selective for Hg(II) and Ag(I) and has been used for preconcentrating Hg(II) and Ag(I) prior to their determination by atomic absorption spectrometry. The maximum sorption capacity for Hg(II) and Ag(I) was found to be 1.74 and 0.52 mmol g−1, respectively, over the pH range 5.5–6.0. The calibration range for Hg(II) was linear up to 10 ng ml−1 with a 3σ detection limit of 0.02 ng ml−1; the calibration range for Ag(I) was linear up to 5 μg ml−1 with a detection limit of 29 ng ml−1. The recoveries of the metals were found to be 99.7±3.8 and 101.3±4.1% at the 95% confidence level for both Hg(II) and Ag(I). In column operation, it has been observed that Hg(II) and Ag(I) in trace quantities can be selectively separated from geological, medicinal and environmental samples.  相似文献   

4.
A new analytical procedure for the reliable and direct determination of arsenic (As) in nitric acid digests of ombrotrophic peat samples in the low ng l−1 range has been developed based on hydride generation-atomic absorption spectrometry (HG-AAS). The pre-reduction capabilities of KI/ascorbic acid and of l-cysteine in nitric acid digests of peat and plant samples for the conversion of As(V) to As(III) were tested systematically. Samples were digested with high purity nitric acid in a high-pressure microwave autoclave at 240 °C and subsequently measured using HG-AAS or ICP-SF-MS (inductively coupled plasma-sector field-mass spectrometry). Using KI/ascorbic acid as pre-reductant, the accuracy and precision were poor when digests of complex matrices, such as peat were analyzed for As by HG-AAS. However, 10 g l−1 l-cysteine was successfully employed as pre-reductant in diluted nitric acid digests (3%, v/v) of peat samples prior to hydride generation of As with 0.5% (m/v) of NaBH4 and 7 mol l−1 HCl. The analytical procedure was critically evaluated by analyzing several certified plant reference materials, two in-house peat reference materials and by the determination of As in diluted digests of peat samples with ICP-SF-MS. The results for the determination of As in various peat and plant materials showed excellent agreement with the reference values. The method detection limits for the determination of As by the optimized HG-AAS procedure and by ICP-SF-MS were 23 ng g−1 and 1.4 ng g−1 in solid peat, respectively. The newly developed analytical procedure was applied to the determination of As in selected peat samples. Results for As in these peat samples obtained by the developed HG-AAS procedure and the optimized procedure for the determination of As with ICP-SF-MS were highly correlated (R2 = 0.993, n = 12).  相似文献   

5.
Commercial non-food packaging materials of four different matrices (paper, low density polyethylene (LDPE), polyethylene-polypropylene (PE-PP) and high density polyethylene (HDPE)) were examined for the content of Cr, Ni, Cu, Zn, As, Mo, Cd, Sb, Ba, Hg, Tl, Pb and U. The examined samples (0.17–0.35 g) were digested in HNO3 and H2O2 (papers, LDPE and PE-PP) and in HNO3, H2SO4 and H2O2 (HDPE) using microwave assisted high pressure system. The inductively coupled plasma-time of flight-mass spectrometry (ICP-TOFMS) has been employed as the detection technique. All measurements were carried out using internal standardization. Yttrium and rhodium (50 ng g−1) were used as internal standards. The detection and quantification limits obtained were in the range of 0.005 ng g−1 (52Cr) to 0.51 ng g−1 (66Zn) and 0.015 μg g−1 (52Cr) to 2.02 μg g−1 (66Zn) of dry mass, respectively. The evaluated contents (mg kg−1) of particular elements in the examined materials were as follows: 0.22–219; <1.05–9.03; 1.25–112; <2.02–449; <0.98–<1.30; <0.36–2.06; <0.29–113; <0.22–44.1; <0.06–57.4; <0.66–<0.88; <0.08–0.24; <0.13–1222 and <0.08–0.44 for Cr, Ni, Cu, Zn, As, Mo, Cd, Sb, Ba, Hg, Tl, Pb and U, respectively.  相似文献   

6.
An inductively coupled plasma mass spectrometer (ICP-MS) equipped with a dynamic reaction cell™ (DRC) was used for the determination of Ca, Fe and Zn in milk powder samples. The effect of the operating conditions of the DRC system was studied to get the best signal-to-noise (S/N) ratio. The potentially interfering 40Ar+, 40Ar16O+, 40Ca16O+, 48Ca16O+ and 32S16O16O+ at the masses m/z 40, 56 and 64 were reduced in intensity significantly by using CH4 as the reaction cell gas in the DRC while a q-value of 0.7 was used. The limits of detection for 40Ca, 56Fe and 64Zn estimated from the external calibration graphs were 1, 0.01 and 0.001 ng ml−1, respectively, which correspond to 1000, 10 and 1 ng g−1 in the original powder sample. This method was applied to the determination of Ca, Fe and Zn in NIST SRM 1549 non-fat milk powder and two milk powder samples purchased locally. The results for the reference sample agreed satisfactorily with the reference values; the accuracy of the determination was better than 3.8, 18 and 2.2% for Ca, Fe and Zn, respectively. The results for which no reference value was available were also found to be in good agreement between different isotopes. Precision (R.S.D.) between sample replicates was better than 10% for all the determinations.  相似文献   

7.
《Analytica chimica acta》2004,520(1-2):237-243
In the Czech Republic no study on the levels of brominated flame retardants in human milk has been conducted, yet. In the first step analytical method for determination of PBDEs in this bioindicator matrix was implemented. Liquid–liquid extraction (LLE) (hexane, diethyl ether), followed by gel permeation chromatography was employed for isolation of PBDEs. Identification and quantification of PBDEs was carried out by GC–MS operated in negative chemical ionisation (NCI). Two mass spectrometric technologies, one employing quadrupole and the other one high resolution (HR) time-of-flight (TOF) analyzer, etc. were used in our study. Detection limits (LODs) obtained by quadrupole analyzer ranged from 0.02 to 0.05 ng g−1 lipid weight, using high resolution time-of-flight analyzer LODs were significantly lower, ranging from 0.002–0.005 ng g−1 lipid weight, what enabled detection of minor PBDE congeners.

Within this pilot study 103 breast milk samples, obtained from mothers living in Olomouc region, were examined. Ten PBDE congeners were determined. All samples examined till now contained PBDEs residues, the dominating contaminant representing this group was congener BDE 47. In most of analysed samples levels of this compound ranged from 0.2 to 2 ng g−1 of lipid weight. Three exceptionally contaminated samples, containing levels of PBDEs 5–10 times higher than other samples, were found.  相似文献   


8.
The determination of cobalt in marine sediments by electrothermal atomic absorption spectrometry was studied using no modifier and magnesium and titanium as modifiers. Titanium is one of the major sediment constituents, which widely affects the cobalt determination and it was studied as a chemical modifier since it was the only concomitant that increased the cobalt signal in the concentration range usually found in sediments. The performance of Mg and Ti as chemical modifiers was compared relative to maximum pyrolysis and atomization temperatures, linear calibration range, sensitivity and matrix effects. The pyrolysis curves showed that the analyte could be stabilized up to 1400 °C when either Ti or Mg(NO3)2 was present, while only 1000 °C could be used in the absence of a modifier. The optimum atomization temperature was 2500 °C in all cases. Analytical curves were compared using no modifier, 5 μg Ti and 100 μg Mg(NO3)2 as modifiers, and the linear range found was up to approximately 4 ng Co whether a modifier was used or not. With Ti as a chemical modifier, analytical curves for cobalt in aqueous solution and in a synthetic matrix resulted in the same sensitivity (m0=55 pg), whereas the use of Mg led to characteristic mass values of 59 and 72 pg in aqueous solution and in a synthetic matrix, respectively, showing some matrix effect. The detection limits (3σ, n=10) were 0.4 μg g−1 using no modifier and 0.3 μg g−1 with Ti as a modifier in the original matrix. A reference estuarine sediment NIST 1646 with a non-certified content of 10.5 μg g−1 Co was analyzed and the found value of 10.9±2.4 μg g−1, (n=3), using Ti as chemical modifier and calibration against aqueous standards, was in good agreement with the recommended value.  相似文献   

9.
Amberlite XAD-16 resin has been functionalized using nitrosonaphthol as a ligand and characterized employing elemental, thermogravimetric analysis and FT-IR spectroscopy. The sorption of Ni(II) and Cu(II) ions onto this functionalized resin is investigated and optimized with respect to the sorptive medium (pH), shaking speed and equilibration time between liquid and solid phases. The monitoring of the influence of diverse ions on the sorption of metal ions has revealed that phosphate, bicarbonate and citrate reduce the sorption up to 10–14%. The sorption data followed Langmuir, Freundlich, and Dubinin–Radushkevich (D–R) isotherms. The Freundlich parameters computed are 1/n = 0.56 ± 0.03 and 0.49 ± 0.05, A = 9.54 ± 1.5 and 6.0 ± 0.5 mmol g−1 for Ni(II) and Cu(II) ions, respectively. D–R isotherm yields the values of Xm = 0.87 ± 0.07 and 0.35 ± 0.05 mmol g−1 and of E = 9.5 ± 0.23 and 12.3 ± 0.6 kJ mol−1 for Ni(II) and Cu(II) ions, respectively. Langmuir characteristic constants estimated are Q = 0.082 ± 0.005 and 0.063 ± 0.003 mmol g−1, b = (4.7 ± 0.2) × 104 and (7.31 ± 0.11) × 104 l mol−1 for Ni(II) and Cu(II) ions, respectively. The variation of sorption with temperature gives thermodynamic quantities of ΔH = −58.9 ± 0.12 and −40.38 ± 0.11 kJ mol−1, ΔS = −183 ± 10 and −130 ± 8 J mol−1 K−1 and ΔG = −4.4 ± 0.09 and −2.06 ± 0.08 kJ mol−1 at 298 K for Ni(II) and Cu(II) ions, respectively. Using kinetic equations, values of intraparticle transport and of first order rate constant have been computed for both the metal ions. The sorption procedure is utilized to preconcentrate these ions prior to their determination in tea, vegetable oil, hydrogenated oil (ghee) and palm oil by atomic absorption spectrometry using direct and standard addition methods.  相似文献   

10.
A liquid chromatographic–tandem mass spectrometric (HPLC-MS/MS) method is proposed for the identification and quantification of tylosin in honey. Sample treatment involves an extraction in a Tris buffer at pH 10.5, followed by a solid-phase clean up step on an Oasis HLB column. Roxithromycin was used as the internal standard. Chromatographic separation of tylosin and roxithromycin was performed on an XTerra MS C18 column (100 mm × 2.1 mm i.d., 5 μm) using a gradient of aqueous 0.01 M ammonium acetate pH 3.5 and acetonitrile as the mobile phase, at a flow rate of 0.25 ml min−1. The method was validated according to the guidelines laid down by the Commission Decision 2002/657/EC. Tylosin residues were confirmed by MS/MS experiments considering the appropriate identification points. All validation parameters such as Cc (lower than 3 ng g−1), Ccβ (lower than 5 ng g−1), recovery and precision were assessed on the basis of the “critical ion” (less intense ion permitting unambiguous identification of the analyte).  相似文献   

11.
A comparison of chiral separation and analysis of selenomethionine in breast and formula milk, using high performance liquid chromatography (HPLC) on a glycopeptide teicoplanin-based chiral stationary phase (Chirobiotic T), coupled to atomic fluorescence spectrometry (AFS) and inductively coupled plasma (ICP) MS detectors has been performed. The coupling HPLC-microwave-assisted digestion hydride generation requires on-line post-column analytes treatment, and a severe sample clean-up for fat and proteins elimination using centrifugation and ultrafiltration. Underivatized -selenomethionine enantiomers were completely resolved in 10 min using unbuffered water mobile phase at 1 ml min−1 flow. Good selectivity and sensitivities (detection limits 3.1 and 3.5 ng ml−1 as Se for - and -selenomethionine, respectively) were obtained, and method robustness and simplicity, together to the low cost of AFS detector, makes it suitable for infant milk routine analysis. HPLC–ICP-MS coupling exhibits very low detection limits (0.9 ng ml−1, as Se) for each -selenomethionine enantiomers, but the method suffers from matrix influence, that produces a poor S/N ratio and low reliability.

The methods were applied to breast and formula milk samples with recoveries of 80% of the total selenium presence, which is attributable to the existence of other unknown species. -Selenomethionine was the only isomer present in breast milk, but a 30% of -selenomethionine was also detected in formula milk.  相似文献   


12.
The proposed flow system was developed in order to minimize the drawbacks related to the PGEs determination by quadrupole-inductively coupled plasma-mass spectrometry (Q-ICP-MS). It was intended not only to lower the limits of detection (LODs) but also to eliminate the interferences originating from some atomic and molecular ions produced in the argon plasma. This was accomplished by means of an on-line sample clean-up/pre-concentration step, using a chelating resin (Metalfix™ Chelamine™) in which Rh, Pd and Pt were preferably retained when compared with the interfering species.

The results obtained by using the developed flow system in the analysis of urine samples are presented. With a sampling rate of 9 samples h−1 (i.e., 27 determinations) and a sample consumption of ca. 10 mL, the developed flow system allowed linear calibration plots up to 100 ng L−1 with detection limits of 1.2 ng L−1 (Rh), 0.4 ng L−1 (Pd) and 0.9 ng L−1 (Pt). Repeatability studies showed good precision (R.S.D.%, n = 5): 3.7% (Rh); 2.6% (Pd) and 2.4% (Pt), for 10 ng L−1; 2.4% (Rh); 1.4% (Pd) and 1.9% (Pt), for 50 ng L−1; and 1.3% (Rh); 0.58% (Pd) and 0.62% (Pt), for 100 ng L−1. By spiking human urine samples, recovery tests were performed, and the values obtained ranged between 89% and 105% (Rh); 90% and 104% (Pd); and 93% and 105% (Pt).  相似文献   


13.
A novel amino-functionalized polymer was synthesized using 3-(trimethoxysilyl) propyl amine (TMSPA) as precursor and hydroxy-terminated polydimethylsiloxane (OH-PDMS) by sol–gel technology and coated on fused-silica fiber. The synthesis was designed in a way to impart polar moiety into the coating network. The scanning electron microscopy (SEM) images of this new coating showed the homogeneity and the porous surface structure of the film. The efficiency of new coating was investigated for headspace solid-phase microextraction (SPME) of some environmentally important chlorophenols from aqueous samples followed by gas chromatography–mass spectrometry (GC–MS) analysis. Effect of different parameters influencing the extraction efficiency such as extraction temperature, extraction time, ionic strength and pH was investigated and optimized. In order to improve the separation efficiency of phenolic compounds on chromatography column all the analytes were derivatized prior to extraction using acetic anhydride at alkaline condition. The detection limits of the method under optimized conditions were in the range of 0.02–0.05 ng mL−1. The relative standard deviations (R.S.D.) (n = 6) at a concentration level of 0.5 ng mL−1 were obtained between 6.8 and 10%. The calibration curves of chlorophenols showed linearity in the range of 0.5–200 ng mL−1. The proposed method was successfully applied to the extraction from spiked tap water samples and relative recoveries were higher than 90% for all the analytes.  相似文献   

14.
Rapid leaching procedures by Pressurized Liquid Extraction (PLE) have been developed for As, Cd, Cr, Ni and Pb leaching from environmental matrices (marine sediment and soil samples). The Pressurized Liquid Extraction is completed after 16 min. The released elements by acetic acid Pressurized Liquid Extraction have been evaluated by inductively coupled plasma-optical emission spectrometry. The optimum multi-element leaching conditions when using 5.0 ml stainless steel extraction cells, were: acetic acid concentration 8.0 M, extraction temperature 100 °C, pressure 1500 psi, static time 5 min, flush solvent 60%, two extraction steps and 0.50 g of diatomaceous earth as dispersing agent (diatomaceous earth mass/sample mass ratio of 2). Results have showed that high acetic acid concentrations and high extraction temperatures increase the metal leaching efficiency. Limits of detection (between 0.12 and 0.5 μg g− 1) and repeatability of the over-all procedure (around 6.0%) were assessed. Finally, accuracy was studied by analyzing PACS-2 (marine sediment), GBW-07409 (soil), IRANT-12-1-07 (cambisol soil) and IRANT-12-1-08 (luvisol soil) certified reference materials (CRMs). These certified reference materials offer certified concentrations ranges between 2.9 and 26.2 μg g− 1 for As, from 0.068 to 2.85 μg g− 1 for Cd, between 26.4 and 90.7 μg g− 1 for Cr, from 9.3 to 40.0 μg g− 1 for Ni and between 16.3 and 183.0 μg g− 1 for Pb. Recoveries after analysis were between 95.7 and 105.1% for As, 96.2% for Cd, 95.2 and 100.6% for Cr, 95.7 and 103% for Ni and 94.2 and 105.5% for Pb.  相似文献   

15.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

16.
Muzikar M  Fontàs C  Hidalgo M  Havel J  Salvadó V 《Talanta》2006,70(5):1081-1086
A new matrix separation/preconcentration method is developed for the on-line determination of palladium(II) and platinum(IV) in complex matrices using a sequential ICP-OES instrument. These metals are preconcentrated in a microcolumn packed with Metalfix-Chelamine, a polymeric functionalised resin containing the tetraethylenepentamine group. The hydrodynamic and chemical conditions of the flow system affecting the loading and elution steps are optimised off-line using a mixture of 1.0 mol L−1 thiourea and 2.0 mol L−1 NaClO4 in 4.0 mol L−1 HCl which proved to be the most effective solution for the simultaneous elution of Pd(II) and Pt(IV). High enrichment factors of nearly 35 are achieved for both metals and the detection limits (LOD) are 22 ng L−1 for platinum and 2.5 ng L−1 for palladium. The accuracy of the method was tested by analysing a used pellet catalyst (certified reference material NIST 2556) and trace metal solutions resulting from the leaching of this material. Despite the fact that this CRM contains zirconium and large amounts of aluminium and lead, a high level of agreement was achieved demonstrating the efficiency of the resin in eliminating interfering elements.  相似文献   

17.
A simple procedure was developed for the speciation of inorganic arsenic by electrochemical hydride generation atomic absorption spectrometry (EcHG–AAS), without pre-reduction of As(V). Glassy carbon was selected as cathode material in the flow cell. An optimum catholyte concentration for simultaneous generation of arsine from As(III) and As(V) was 0.06 mol l−1 H2SO4. Under the optimized conditions, adequate sensitivity and difference in ratio of slopes of the calibration curves for As(III) and As(V) can be achieved at the electrolytic currents of 0.6 and 1 A. The speciation of inorganic arsenic can be performed by controlling the electrolytic currents, and the concentration of As(III) and As(V) in the sample can be calculated according to the equations of absorbance additivity obtained at two selected electrolytic currents. The calibration curves were linear up to 50 ng ml−1 for both As(III) and As(V) at 0.6 and 1 A. The detection limits of the method were 0.2 and 0.5 ng ml−1 for As(III) and As(V) at 0.6 A, respectively. The relative standard deviations were of 2.1% for 20 ng ml−1 As(III) and 2.5% for 20 ng ml−1 As(V). The method was validated by the analysis of human hair certified reference material and successfully applied to speciation of soluble inorganic arsenic in Chinese medicine.  相似文献   

18.
The microbial activity in a Rhodic eutrudox (R), a Typic eutrudox (V) and a Quartzipsamment (Q) was monitored by respirometric and calorimetric methods. CO2 evolution was monitored for 98 days by titrimetry and conductimetry for control amended samples (A) with 25% of cattle manure (E), municipal refuse compost (L), earthworm casts (H) or 1.25 kg ha−1 of trifluralin (T). Average values of all treatments through respiration at the end of the incubation period were 5.24±0.34, 6.13±0.31 and 6.50±0.33, in mg CO2 g−1 soil, for R, V and Q, respectively, by titrimetry and 8.89±0.44, 10.41±0.54 and 10.41±0.52, in mg CO2 g−1 soil, for R, V and Q, respectively, for conductimetry. Excellent correlation (r=1.00) between titrimetry and conductimetry was observed. The decreasing order for respiration was E, H, L and T. After each incubation time, the conductimetric values were higher than those for titrimetry, for all treatments of these Brazilian soils. Average values of the exothermic thermal effect were: 0.58±0.02, 0.60±0.02 and 0.67±0.01 kJ g−1 soil, for R, V and Q, respectively, for 103 days. A significant correlation coefficient of 0.91 and P<0.0001 between calorimetric and respirometric values over 98 days was observed. Based on the obtained calorimetric results, it can be proposed that this technique should be as a useful analytical method for determining the microbial activity in soils.  相似文献   

19.
In this work, tetramethylammonium hydroxide (TMAH) was used to solubilize the DORM-1 dogfish muscle certified reference material as a model substance for the determination of As, Cd, Pb and Se by electrothermal atomic absorption spectrometry (ET AAS). The sample was mixed with a small amount of TMAH and heated to 60 °C for 10 min in a water bath. After dissolution, As and Se were determined using palladium and magnesium nitrates as a chemical modifier added in solution. For Cd and Pb, best results were obtained with a mixture of 250 μg of each of iridium and rhodium as permanent modifiers. In both cases, the calibration was performed with aqueous solutions in 0.2% v/v HNO3. The temperature program for each analyte was optimized using pyrolysis and atomization curves established with the fish reference material. The detection limits in dry samples and the characteristic mass values were: Cd 0.005 μg g−1 and 0.9 pg; Pb 0.04 μg g−1 and 7.6 pg; As 0.4 μg g−1 and 13 pg and Se 0.6 μg g−1 and 20 pg, respectively. Results from the determination of these elements in the DORM-1 certified fish reference material were within the 95% confidence interval of the certified values.  相似文献   

20.
Analytical procedures have been developed for the reliable determination of 19 trace elements (Ag, Al, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Pb, Rb, Sb, Sc, Sr, Tl, U, V, Zn) in ice samples at pg g−1 and fg g−1 concentrations using ICP-sector field mass spectrometry (ICP-SMS). Concentrations of most elements in the high purity water and doubly distilled HNO3 employed were distinctly lower than previously reported values. The accuracy of the results was carefully evaluated using the certified water reference material SLRS-4. Contributions of unwanted trace elements due to acidification of the ice samples (0.5% HNO3) to the total element budget amounted to only 0.001 pg g−1 for Bi, 0.34 pg g−1 for Cr, 0.2 pg g−1 for Fe, 0.004 pg g−1 for Pb, 0.00015 pg g−1 for U and 0.0025 pg g−1 for V: compared to the concentrations of the metals in ice these are negligible. The use of a detergent (0.05%) in the rinsing solution (0.5% HNO3), helped to reduce memory effects by 59–98%, depending on the element considered; this resulted in shorter washing times between samples (i.e. 1 min) and improved analysis time. Adopting strict clean room procedures, the detection limit for Pb (0.06 pg g−1) is a factor of ten lower than the current state-of-the-art. Compared to previous studies, the improved LODs obtained here for other trace elements amount to 2× (Ag), 4× (Sb), 5× (Ba), 6× (Cu, Mn, U), 9× (Bi), 13× (Cd), 18× (Fe) and 21× (V). The developed analytical protocols were successfully applied to the determination of selected trace elements in age-dated ice samples from the Canadian High Arctic. The toxic trace element Tl (median: 0.16 pg g−1; range: 0.03–1.32 pg g−1) and the lithogenic reference element Sc (0.53 pg g−1; 0.06–2.9 pg g−1) have been determined in a polar ice core for the first time.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号