首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

A stability-indicating liquid chromatographic method was developed and validated for quantitative determination of olmesartan medoxomil (OLM) in coated tablets in the presence of degradation products generated under stress conditions. An isocratic LC separation was performed using a Phenomenex RP-18 column using a mobile phase consisting of water:triethylamine:acetonitrile (60:0.3:40 v/v/v, pH adjusted to 6.3 with phosphoric acid). The flow rate was 1.2 mL min−1 and the detection was achieved with a photodiode array detector set at 257 nm. The response was linear over a range of 10.0 to 30.0 μg mL−1 (r = 0.9999). The specificity and stability-indicating capability of the method was verified subjecting the reference substance and drug product to hydrolytic, oxidative, photolytic, and thermal stress conditions. The method showed a good and consistent recovery (100.2%) with low intra- and inter-day relative standard deviation (RSD) (≤1.0%). A considerable degradation occurred in all stress conditions and the degradation product was well resolved from the main peak. There was no interference of the excipients in the determination of the active pharmaceutical ingredient. Thus, the proposed method was found to be stability-indicating and can be used for routine analysis for quantitative determination of OLM in coated tablets without the interference of major degradation products.

  相似文献   

2.
A stability-indicating HPLC method has been developed and subsequently validated for the simultaneous determination of domperidone and pantoprazole in commercial tablets. The proposed HPLC method utilizes Phenomenex® Gemini C18 column (150 mm × 4.6 mm i.d., 5 μm) and mobile phase consisting of methanol-acetonitrile-20 mM dipotassium hydrogen phosphate and phosphoric acid buffer pH 7.0 (20:33:47, v/v/v) at a flow rate of 1.19 mL min?1. Quantitation was achieved with UV detection at 285 nm based on peak area with linear calibration curves at concentration ranges 0.5–5.0 μg mL?1 for domperidone and 1.0–10 μg mL?1 for pantoprazole (R 2 > 0.999 for both drugs). The method was validated in terms of accuracy, precision, linearity, limits of detection, limits of quantitation and robustness. This method has been successively applied to pharmaceutical formulation and no interference from the tablet excipients was found. Domperidone, pantoprazole and their combination drug product were exposed to acid, base and neutral hydrolysis, oxidation, dry heat and photolytic stress conditions and the stressed samples were analyzed by the proposed method. As the proposed method could effectively separate the drug from its degradation products, it can be employed as stability-indicating method for the determination of instability of these drugs in bulk and commercial products.  相似文献   

3.
A stability-indicating hydrophilic interaction liquid chromatography (HILIC) method has been developed and validated for the quantitative determination of Brimonidine tartrate (BT) formulated as an ophthalmic solution. Isocratic separation was achieved using an acetonitrile-buffer mixture (92:8, v/v) at pH 7.1 on an unmodified silica column (250 × 4.6 mm, 5 μm). The drug was subjected to oxidative, hydrolytic, photolytic and thermal stress conditions and complete separation was achieved for the parent compound and degradation products. The influence of acetonitrile, pH and ionic strength of the buffer was studied. Linearity range and recoveries for BT were 100–400 μg mL?1 and 100.12%, respectively. The method was validated for BT and indicated that the method was sufficiently sensitive with a limit of detection at 0.005 μg mL?1 and a limit of quantitation at 0.02 μg mL?1, respectively.  相似文献   

4.
Simple, sensitive, selective, precise, and stability-indicating thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) methods for the determination of mosapride and pantoprazole in pharmaceutical tablets were developed and validated as per the International Conference on Harmonization guidelines. The TLC method employs aluminum TLC plates precoated with silica gel 60F254 as the stationary phase and ethyl acetate/methanol/toluene (4:1:2, v/v/v) as the mobile phase to give compact spots for mosapride (R f 0.73) and pantoprazole (R f 0.45) separated from their degradation products; the chromatogram was scanned at 276 nm. The HPLC method utilizes a C18 column and a mobile phase consisting of acetonitrile/methanol/20 mM ammonium acetate (4:2:4, v/v/v) at a flow rate of 1.0 mL min?1 for the separation of mosapride (t R 11.4) and pantoprazole (t R 4.4) from their degradation products. Quantitation was achieved with UV detection at 280 nm. The same HPLC method was successfully used in performing calibrations in lower concentration ranges for both drugs in human plasma using ezetimibe as internal standard. The methods were validated in terms of accuracy, precision, linearity, limits of detection, and limits of quantification. Mosapride and pantoprazole were exposed to acid hydrolysis and then analyzed by the proposed methods. As the methods could effectively separate the drugs from their degradation products, these techniques can be employed as stability-indicating methods that have been successively applied to pharmaceutical formulations without interference from the excipients. Moreover the HPLC method was successfully used in the determination of both drugs in spiked human plasma.  相似文献   

5.
A stability-indicating UPLC method was developed for the simultaneous quantitative determination of losartan potassium, atenolol, and hydrochlorothiazide in pharmaceutical dosage forms in the presence of degradation products. The separation was achieved on a simple isocratic method (water: acetonitrile: triethyl amine: ortho phosphoric acid (60:40:0.1:0.1, v/v) at 0.7 mL min?1, a detection wavelength of 225 nm). The retention times of losartan potassium, atenolol, and hydrochlorothiazide were 2.3, 0.6 and 0.9 min. The total runtime was 3 min. Losartan potassium, atenolol, and hydrochlorothiazide were subjected to different ICH prescribed stress conditions. The method was validated with respect to linearity, accuracy, precision, robustness and ruggedness.  相似文献   

6.
A forced degradation study on ropinirole hydrochloride in bulk and in its modified release tablets was conducted under the conditions of hydrolysis, oxidation and photolysis in order to develop an isocratic stability-indicating LC-UV method for quantification of the drug in tablets. An impurity peak in standard solution was found to increase under acidic and neutral hydrolytic conditions while another degradation product was formed under alkaline condition. The drug and its degradation products were optimally resolved on a Hypersil C18 column with mobile phase composed of diammonium hydrogen orthophosphate (0.05 M; pH 7.2), tetrahydrofuran and methanol (80:15:5% v/v) at a flow rate of 1.0 mL min?1 at 30 °C using 250 nm as detection wavelength. The method was linear in the range of 0.05–50 μg mL?1 drug concentrations. The %RSD of inter- and intra-day precision studies was <1. The system suitability parameters remained unaffected during quantification of the drug on three different LC systems. Excellent recoveries (101.59–102.28%) proved that the method was sufficiently accurate. The LOD and LOQ were found to be 0.012 and 0.040 μg mL?1, respectively. Degradation behaviour of the drug in both bulk and tablets was similar. The drug was very unstable to hydrolytic conditions but stable to oxidative and photolytic conditions. The method can be used for rapid and accurate quantification of ropinirole hydrochloride in tablets during stability testing. Based on chemical reactivity of ropinirole in different media, the degradation products were suspected to be different from the known impurities of the drug.  相似文献   

7.
This paper describes development and validation of a high-performance liquid chromatographic method for simultaneous analysis of tramadol hydrochloride (TR) and aceclofenac (AC) in a tablet formulation. When the combination formulation was subjected to ICH-recommended stress conditions, adequate separation of TR, AC, and the degradation products formed was achieved on a C18 column with 65:35 (v/v) 0.01 M ammonium acetate buffer, pH 6.5—acetonitrile as mobile phase at a flow rate of 1 mL min?1. UV detection was performed at 270 nm. The method was validated for specificity, linearity, LOD and LOQ, precision, accuracy, and robustness. The method was specific against placebo interference and also during forced degradation. The linearity of the method was investigated in the concentration ranges 15–60 μg mL?1 (r = 0.9999) for TR and 40–160 μg mL?1 (r = 0.9999) for AC. Accuracy was between 98.87 and 99.32% for TR and between 98.81 and 99.49% for AC. Because degradation products were well separated from the parent compounds, the method was stability-indicating.  相似文献   

8.
A simple, accurate, precise and fully automated method for the simultaneous determination of abacavir, lamivudine and zidovudine in pharmaceutical tablets, human serum samples and drug dissolution studies has been developed. Separation was performed on a 5 μm Zorbax® C18 column (150 × 4.6 mm ID) with methanol:water:phosphate buffer at pH 5.65 (80:10:10; v/v/v) isocratic elution in less than 7 min with a flow rate of 0.6 mL min?1.Good sensitivity for all analytes was observed with UV detection at 275 nm. The method allowed quantitation over the 500–3,000 ng mL?1 range for abacavir and 500–5,000 ng mL?1 range for lamivudine and zidovudine. The method has been applied, without any interference from excipients or endogenous substances, for the simultaneous determination of these three compounds in tablets. Human serum and drug dissolution studies.  相似文献   

9.
A simple, sensitive, selective, precise and stability-indicating thin-layer chromatographic method for determination of dutasteride both as a bulk drug and as pharmaceutical tablets was developed and validated as per the International Conference on Harmonization guidelines. The method employed thin-layer chromatography aluminium plates precoated with silica gel 60F254 as the stationary phase and the mobile phase consisted of acetonitrile:methanol:dichloromethane in the ratio of 2.0:1.0:2.0, v/v/v. This solvent system was found to give compact spots for dutasteride (R f value of 0.64 ± 0.02). Densitometric analysis of dutasteride was carried out in the absorbance mode at 244 nm. The linear regression analysis data for the calibration plots showed good linear relationship with r = 0.9943 with respect to peak area in the concentration range of 100–600 ng per band. The method was validated for precision, accuracy, ruggedness and recovery. The limits of detection and quantitation were 7.54 and 22.85 ng per band, respectively. Dutasteride was subjected to acid and alkali hydrolysis, oxidation, photo degradation, dry heat and wet heat treatment. The drug undergoes degradation under acidic, basic conditions, photolytic, oxidative and upon wet and dry heat treatment. The degraded products were well separated from the pure drug. The statistical analysis proves that the developed method for quantification of dutasteride as bulk drug and from pharmaceutical tablets is reproducible and selective. As the method could effectively separate the drug from its degradation products, it can be employed as stability-indicating.  相似文献   

10.
A simple, stability-indicating, reversed-phase liquid chromatographic method was developed for the determination of lacidipine in the presence of its degradation products. The analysis was carried out using a 150 mm × 4.6 mm i.d., 5 μm particle size Nucleodur MN-C18 column. Mobile phase containing a mixture of acetonitrile and 0.02 M phosphate buffer (70:30) at pH = 5.0 was pumped at a flow rate of 1 mL min?1 with UV-detection at 254 nm. The method showed good linearity in the range of 0.06–15 μg mL?1 with a limit of detection (S/N = 3) of 0.016 μg mL?1 (3.5 × 10?8 M). The suggested method was successfully applied for the analysis of lacidipine in bulk and in commercial tablets with average recoveries of 100.19 ± 0.81% and 100.05 ± 0.69%, respectively. The results were favorably compared to those obtained by a reference method. The suggested method was utilized to investigate the kinetics of alkaline, acidic, peroxide and photo-induced degradation of the drug. The apparent first-order rate constant, half-life times and activation energies of the degradation process were calculated. The pH profile curve was derived. The proposed method was successfully applied to the content uniformity testing of tablets.  相似文献   

11.
A stability-indicating UPLC method was developed for quantitative determination of 9-desmethyl-α-dihydrotetrabenazine (9-DM-α-DTBZ), the precursor for preparing a widely used vesicular monoamine transporter 2 imaging agent 11C-α-DTBZ. Compound 9-DM-α-DTBZ was subjected to various stress conditions consisting of acidic, alkaline, oxidative, thermal and photolytic forced degradation. The decomposition of 9-DM-α-DTBZ was observed under oxidative condition, whereas no obvious degradation was shown under the other stress conditions. For chromatographic separation of 9-DM-α-DTBZ and its degradation products, an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm) and a mobile phase of 20:80 (v/v) methanol/ammonium acetate buffer (pH 4.5, 10 mM) were used. Quantitative determination of 9-DM-α-DTBZ was performed using a PDA detector at a flow rate of 0.30 mL min?1. UPLC–MS analysis was further utilized to characterize the two degradation products. The proposed method was fully validated as per USP guidelines with respect to linearity, accuracy, precision, robustness, limit of detection (LOD) and limit of quantification (LOQ). The linear regression analysis showed a good linear relationship (r 2  = 0.9995) in the concentration range of 0.001–1.00 mg mL?1 (n = 6). The assay method was found to have good precision (1.14–1.35% RSD) and recovery (98.91–101.23%). Additionally, the LOD and LOQ of 9-DM-α-DTBZ were 0.30 and 1.00 μg mL?1, respectively. These results indicated that the present method could be used to evaluate the quality of regular production samples and also used in stability assays.  相似文献   

12.
The objectives of this investigation were to establish a validated stability-indicating LC method for assay of carvedilol and to study the degradation behaviour of the drug under different ICH-recommended stress conditions. Chromatographic separation was achieved on a C18 column with 55:45 (%, v/v) acetonitrile–0.02 m phosphate buffer, pH 3.5, as mobile phase at a flow rate of 1.0 mL min?1; detection was by UV absorbance at 242 nm. The method was validated for linearity, precision, accuracy, robustness, specificity, and sensitivity, with the bulk drug. The drug was subjected to forced degradation and peaks of all the degradation products were well resolved from that of the pure drug, with significantly different retention times, which indicates the specificity and stability-indicating properties of the method. First-order degradation kinetics of carvedilol were observed under acidic and alkaline conditions. When the utility of the method was verified by analysis of the drug in marketed tablets and a nano-emulsion formulation, the assay was found to be 98.60–99.61 and 99.52–99.87, respectively. These results indicate the method can be successfully used for routine analysis of carvedilol in the bulk drug and in pharmaceutical dosage forms.  相似文献   

13.
A simple reverse phase liquid chromatographic method was developed for the quantitative determination of desipramine hydrochloride and its related impurities in bulk drugs which is also stability-indicating. During the forced degradation at hydrolysis, oxidative, photolytic and thermal stressed conditions, the degradation results were only observed in the oxidative stress condition. The blend of the degradation product and potential impurities were used to optimize the method by an YMC Pack Pro C18 stationary phase. The LC method employs a linear gradient elution with the water–acetonitrile–trifluoroacetic acid as mobile phase. The flow rate was 1.0 mL min?1 and the detection wavelength 215 nm. The stressed samples were quantified against a qualified reference standard and the mass balance was found close to 99.0% (w/w) when the response of the degradant was considered to be equal to the analyte (i.e. desipramine). The developed RP-LC method was validated in agreement with ICH requirements.  相似文献   

14.
A simple, isocratic, stability-indicating liquid chromatographic method for quantitative determination of curcumin was successfully developed. The chromatographic separations were achieved using a Hi-Q-Sil C18; 4.6 mm × 250 mm and 10 μm particle size column employing acetonitrile and acetate buffer (pH 3.0; 60: 40, v/v) as the mobile phase. The analyte was subjected to acidic, basic, oxidative, thermal and photo degradation. The method was validated with respect to linearity, precision, accuracy, limit of detection and limit of quantification. Curcumin was detected by UV-Vis detector at 425 nm whereas the degradation products were detected at 280 nm. The method was linear over the concentration range of 1–10 μg mL?1. The limit of detection was found to be 0.06 μg mL?1 and the quantification limit was 0.21 μg mL?1. Considerable degradation of the analyte was observed when it was subjected to alkaline conditions. Accuracy, evaluated as recovery, was in the range of 97–103%. Intra-day precision and intermediate precision showed relative standard deviations <1% and <2% respectively.  相似文献   

15.
The stability-indicating LC assay method was developed and validated for quantitative determination of cefcapene pivoxil in the presence of degradation products formed during forced degradation studies. An isocratic RP-HPLC method was developed with a Lichrospher RP-18 (250 mm × 4.6 mm, 5 μm) column and the mobile phase composed of 45 volumes of acetonitrile and 55 volumes of mixture composed of citric acid 10 mmol L?1 and potassium chloride 18 mmol L?1. The flow rate of the mobile phase was 1 mL min?1. Detection wavelength was 270 nm and temperature was 30 °C. Cefcapene pivoxil, similar to other cephalosporins, was subjected to stress conditions of degradation in aqueous solutions including hydrolysis, oxidation, and thermal degradation. The method was validated with regard to linearity, accuracy, precision, selectivity, and robustness. The method was applied successfully for the determination of cefcapene pivoxil during kinetic studies in aqueous solutions (pH and thermal degradation) and in solid state (oxidative, thermal, and radiolytic degradation).  相似文献   

16.
A simple rapid and stability-indicating LC method using a narrow-bore column has been developed, fully validated, and applied to the quantification of alfuzosin in pharmaceutical formulations. Chromatography was achieved isocratically on a narrow-bore, 5-μm particle size, C8 analytical column. The mobile phase was a 35:65 (v/v) 0.0125 m ammonium formate–acetonitrile at a flow rate of 0.35 mL min?1. Detection was by UV absorption at 245 nm. Evaluation over the range 200–800 ng mL?1 revealed linearity was good. Limits of detection and quantification for alfuzosin were 22.9 and 69.5 ng mL?1, respectively. Intra-day and inter-day RSD were less than 6.4%, and the relative percentage error was less than ?1.7% (n = 5). Accelerated degradation performed under different stress conditions including oxidation, hydrolysis, and heat, proved the selectivity of the procedure. The method was successfully used for quality-control and content-uniformity testing of commercial tablets.  相似文献   

17.
Hegazy  Maha A.  Yehia  Ali M.  Mostafa  Azza A. 《Chromatographia》2011,74(11):839-845

Simple, sensitive, selective, precise, and stability-indicating thin-layer chromatography (TLC) and high-performance liquid chromatography (HPLC) methods for the determination of mosapride and pantoprazole in pharmaceutical tablets were developed and validated as per the International Conference on Harmonization guidelines. The TLC method employs aluminum TLC plates precoated with silica gel 60F254 as the stationary phase and ethyl acetate/methanol/toluene (4:1:2, v/v/v) as the mobile phase to give compact spots for mosapride (R f 0.73) and pantoprazole (R f 0.45) separated from their degradation products; the chromatogram was scanned at 276 nm. The HPLC method utilizes a C18 column and a mobile phase consisting of acetonitrile/methanol/20 mM ammonium acetate (4:2:4, v/v/v) at a flow rate of 1.0 mL min−1 for the separation of mosapride (t R 11.4) and pantoprazole (t R 4.4) from their degradation products. Quantitation was achieved with UV detection at 280 nm. The same HPLC method was successfully used in performing calibrations in lower concentration ranges for both drugs in human plasma using ezetimibe as internal standard. The methods were validated in terms of accuracy, precision, linearity, limits of detection, and limits of quantification. Mosapride and pantoprazole were exposed to acid hydrolysis and then analyzed by the proposed methods. As the methods could effectively separate the drugs from their degradation products, these techniques can be employed as stability-indicating methods that have been successively applied to pharmaceutical formulations without interference from the excipients. Moreover the HPLC method was successfully used in the determination of both drugs in spiked human plasma.

  相似文献   

18.
A reversed-phase liquid chromatography (RP-LC) method was validated for the determination of rupatadine in pharmaceutical dosage forms. The LC method was carried out on a Gemini C18 column (150 mm × 4.6 mm I.D.), maintained at 30 °C. The mobile phase consisted of ammonium acetate buffer (pH 3.0; 0.01 M) with 0.05% of 1-heptanesulfonic acid–acetonitrile (71.5:28.5, v/v), run at a flow rate of 1.0 mL min?1 and using photodiode array (PDA) detection at 242 nm. The chromatographic separation was obtained with retention time of 5.15 min, and was linear in the range of 0.5–400 μg mL?1 (r = 0.9999). The specificity and stability-indicating capability of the method was proven through the degradation studies and showing also, that there was no interference of the excipients. The accuracy was 100.39% with bias lower than 0.58%. The limits of detection and quantitation were 0.01 and 0.5 μg mL?1, respectively. Moreover, method validation demonstrated acceptable results for precision, sensitivity and robustness. The proposed method was applied for the analysis of pharmaceutical dosage forms assuring the therapeutic efficacy.  相似文献   

19.
A simple, selective and sensitive stability indicating LC method has been developed and validated for the determination of faropenem in bulk drug and pharmaceutical formulations in the presence of degradation products. The separation was achieved by using an isocratic mobile phase mixture of acetate buffer of pH 3.5 and methanol (65:35, v/v) and 250 mm × 4.6 mm I.D., 5 μm particle size SGE make Wakosil C-18 AR column at flow rate of 1.0 mL min?1 with detection at 305 nm. The retention time of faropenem is 6.63 min and was linear in the range of 5–75 μg mL?1 (r = 0.9999). The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation and was found to be unstable in all the stress conditions. The proposed method was successfully employed for quantification of faropenem in bulk drug and its pharmaceutical formulations.  相似文献   

20.
A new, sensitive, stability indicating gradient RP-LC related substances and assay method has been developed for the quantitative determination of entacapone in bulk drugs. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination of buffer and acetonitrile. Buffer consisted of 0.1% orthophosphoric acid, delivered in a gradient mode and quantitation was carried out using ultraviolet detection at 220 nm with a flow rate of 1.5 mL min?1. In the developed LC method the resolution (R s ) between entacapone and its three potential process impurities were found to be >2.0. Regression analysis showed an r 2 value (correlation coefficient) >0.99 for entacapone and its three potential impurities. This method was capable to detect all three process impurities of entacapone at a level of 0.003% with respect to test concentration of 0.5 mg mL?1 for a 20 μL injection volume. The inter- and intra-day precision values for all three impurities and for entacapone was found to be within 2.0% RSD. The method has shown good and consistent recoveries for entacapone in bulk drugs (99.2–101.5%) and its three impurities (99.5–102.2%). The test solution was found to be stable in diluent for 48 h. The drug substances were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress, base stress and oxidative conditions. The stressed test solutions were assayed against the qualified working standard of entacapone and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏