首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 17 毫秒
1.
A highly sensitive liquid chromatography–tandem mass spectrometry (LC–MS–MS) method for the determination of troxerutin in human plasma using tramadol as internal standard (IS) has been developed and validated. Sample preparation involved liquid–liquid extraction with ethyl acetate–isopropanol (95:5, v/v). The analyte and IS were separated by RP–LC with gradient elution using 10 mM ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.9 mL min?1. LC–MS–MS in the positive ion mode employed multiple reaction monitoring of the transitions at m/z 743.2→435.3 and m/z 264.1→58.0 for troxerutin and IS, respectively. The assay was linear in the concentration range 0.01–10 ng mL?1 with precision and accuracy within assay variability limits as per FDA guidelines. The assay was successfully applied to a pharmacokinetic study involving oral administration of 300 mg troxerutin to eight healthy Chinese volunteers.  相似文献   

2.
A rapid and sensitive method for the quantitative determination of picroside II in rat plasma was developed and validated using liquid chromatographic separation with tandem mass spectrometric detection. The analytes of interest were extracted from rat plasma samples by ethyl acetate after acidification with 1.0% acetic acid solution. Chromatographic separation was achieved on a Hypersil GOLD column (50 × 2.1 mm I.D., 5 μm) using a mobile phase consisting of acetonitrile–0.1% formic acid solution (30:70, v/v) at a flow rate of 0.2 mL min?1. Detection was performed on a triple quadrupole tandem mass spectrometer by selected reaction monitoring (SRM) mode via electrospray ionization (ESI). The calibration curve was linear in the concentration range of 1.00–400 ng mL?1 in rat plasma, with a 1.00 ng mL?1 lower limit of quantification (LLOQ). Satisfactory results were achieved for intraday repeatability [relative standard deviation (RSD) = 6.4–12.4%] and inter-day precision (RSD = 6.8–14.7%). The accuracy in terms of relative error ranged from ?2.1 to 10.0%. The extraction recoveries of picroside II and icariin (internal standard) were 80.0 and 89.3%, respectively. The developed method was successfully employed to determine picroside II plasma concentrations after oral administration to Wistar rats.  相似文献   

3.
Batifiban is a new platelet GPIIb/IIIa receptor antagonist. In this work, an analytical method based on liquid chromatography and electrospray ionization tandem mass spectrometry has been firstly developed and validated for the quantitative measurement of batifiban in human plasma to support the investigation of this compound. Separation of analyte and the internal standard eptifibatide was performed on a Thermo HyPURITY C18 column (150 × 2.1 mm, 5 μm) with a mobile phase consisting of formic acid 0.1% (v/v)–acetonitrile (40:60, v/v) at a flow rate of 0.25 mL min?1. The Waters QuattroMicro API triple quadrupole mass spectrometer was operated in multiple reaction monitoring mode via positive electrospray ionization interface using the transition m/z 819.2 → m/z (623.9 + 159.4) for batifiban and m/z 833.4 → m/z (645.7 + 159.3) for IS. The method was linear over the concentration range of 2.45–5,000 μg L?1. The intra- and inter- day precisions were less than 15% in terms of relative standard deviation, and the accuracy was within 8.5% in terms of relative error (RE). The lower limit of quantification (LLOQ) was identifiable and reproducible at 2.45 μg L?1 with acceptable precision and accuracy. The validated method offered sensitivity and wide linear concentration range. This method was successfully applied for the evaluation of pharmacokinetics of batifiban afer single oral doses of 55, 110 and 220 μg kg?1 batifiban to 36 Chinese healthy volunteers.  相似文献   

4.
A sensitive and selective liquid chromatography–tandem mass spectrometry method for the determination of memantine was developed and validated over the linearity range 0.1–25 ng mL?1 with 0.5 mL of plasma using procainamide as the internal standard. This analysis was carried out on a Cosmosil 5C18-MS column and the mobile phase was composed of methanol: 0.5% formic acid (50:50, v/v). Detection was performed on a triple–quadrupole tandem mass spectrometer using positive ion mode electrospray ionization and quantification was performed by multiple reaction monitoring mode. The MS–MS ion transitions monitored were m/z 180 → 107 and 236 → 163 for memantine and procainamide, respectively. The between- and within-day precision was less than 10.9% and accuracy was less than 2.5%. The lower limit of quantification (LLOQ) was 0.1 ng mL?1. The method proved to be accurate and specific, and was applied to the pharmacokinetic study of memantine in healthy Chinese volunteers.  相似文献   

5.
In this study, a rapid, sensitive and reproducible liquid chromatography–tandem mass spectrometry method for the determination of levonorgestrel in human plasma, was developed and validated. With a structural analogue norethindrone as the internal standard, levonorgestrel was extracted from plasma using ethyl acetate. The organic layer was evaporated to dryness and the residue was reconstituted in mobile phase. An aliquot of 20 μL was chromatographically analyzed on a Phenomenex Luna C18 column with water and acetonitrile as the mobile phase. Selected reaction monitoring was specific for mass detection employing positive electrospray ionization. The calibration standards were linear over the concentration range 0.625–40 ng mL?1. The intra- and inter-day precision over the entire concentration range were less than 8.16%. The method was found to be suitable for application to a pharmacokinetic study after oral administration of 1.5 mg levonorgestrel tablet to 20 healthy female volunteers.  相似文献   

6.
A sensitive and specific liquid chromatography–electrospray ionization-tandem mass spectrometry method has been developed and validated for the identification and quantification of ursolic acid in human plasma using glycyrrhetic acid as an internal standard. The method involves extraction with methyl tert-butyl ether. The analyte was separated on a C18 column and analyzed in multiple reaction monitoring mode with a negative electrospray ionization interface using the [M–H]? ions, m/z 455.4 for ursolic acid and m/z 469.5 → m/z 425.5 for glycyrrhetic acid. The method was validated over the concentration range of 0.86–110.0 μg L?1. The intra- and inter-day precisions were less than 13.53% relative standard deviation (RSD) and the accuracy was within ?4.76% in terms of relative error (RE). The lower limit of quantification was 0.86 μg L?1 with acceptable precision and accuracy. There were almost no matrix effects. Recovery of ursolic acid from spiked drug-free plasma was higher than 68%. The method was used to study the pharmacokinetic profile of ursolic acid in human plasma after oral administration of Jieyu capsules.  相似文献   

7.
8.
9.
A sensitive and specific liquid chromatography–tandem mass spectrometry (LC–MS–MS) method was developed and validated for the quantification of poricoic acid A (PAA) in rat plasma. The plasma samples were precipitated by protein precipitation with methanol. Glycyrrhetic acid was used as the IS. Chromatography was performed on a Dionex C18 120 Å (4.6 × 250 mm, 5 μm) column with the mobile phase composed of acetonitrile–water (90:10, v/v) at a flow rate of 0.8 mL min?1. A tandem mass spectrometer equipped with an ESI source was used as the detector and was operated in the negative ion mode. Quantification was performed using multiple reaction monitoring (MRM) of the transitions m/z 497.4 → 423.3 and m/z 469.2 → 425.1 for PAA and IS, respectively. The calibration curves were linear over the range of 5–5,000 ng mL?1 (r 2 = 0.9966) and the lower limit of quantification (LLOQ) was 5 ng mL?1. In this range, RSDs were <10% for intra-assay and inter-assay precisions. The accuracy expressed by deviation (DEV) was <6%, and the extraction recoveries of QC samples were >78%. The validated method was successfully used to study the pharmacokinetics of PAA in rats after intravenous administration at a dose of 1.0, 2.5 and 5.0 mg kg?1 and oral administration at a dose of 25, 50 and 100 mg kg?1, respectively. The relative bioavailability of PAA in rats following oral administration was achieved.  相似文献   

10.
Xin Hu  Yun-Feng Lv  Kai-Shun Bi 《Chromatographia》2009,69(9-10):1073-1076
A rapid and simple high-performance liquid chromatographic tandem mass spectrometric method has been developed and validated for analysis of strictosamide in rat plasma. Chromatographic separation was achieved on a C18 column by gradient elution with mixtures of methanol, water, and acetonitrile containing 0.05% acetic acid. Digoxin was used as internal standard. Selected reaction monitoring (SRM) was used for MS quantitation. Linearity was good in the range 0.05–20 ng mL?1 in rat plasma. The lower limit of quantitation was 0.04 ng mL?1. The method is precise and reliable and can be applied to pharmacokinetic studies.  相似文献   

11.
A liquid chromatography–tandem mass spectrometry (LC–MS–MS) method was developed for the simultaneous determination of paracetamol, pseudoephedrine and chlorpheniramine in human plasma. Diphenhydramine was used as the internal standard. Analytes were extracted from alkalized human plasma by liquid–liquid extraction (LLE) using ethyl acetate. After electrospray ionization positive ion fragments were detected in the selected reaction monitoring (SRM) mode with a triple quadrupole tandem mass spectrometer. The method was linear in the concentration range of 20.0–10000.0 ng mL?1 for paracetamol, 1.0–500.0 ng mL?1 for pseudoephedrine and 0.1–50.0 ng mL?1 for chlorpheniramine. The intra- and inter-day precisions were below 14.5% and the bias was between ?7.3 and +2.8% for all analytes. The validated LC–MS–MS method was applied to a pharmacokinetic study in which each healthy Chinese volunteer received a tablet containing 300 mg benorylate, 30 mg pseudoephedrine hydrochloride and 2 mg chlorpheniramine maleate. This is the first assay method described for the simultaneous determination of paracetamol, pseudoephedrine and chlorpheniramine in human plasma samples.  相似文献   

12.
13.
A bioanalytical method has been developed and validated for determination of drospirenone in human plasma. The analytical method consists in the extraction of plasma sample with dichloromethane, followed by determination of drospirenone by LC–MS–MS using levonorgestrel as internal standard. Separation was achieved on a Peerless cyano column with an isocratic mobile phase consisting of methanol and ammonium formate buffer. Protonated ions formed by a Turboionspray in the positive mode were used to detect analyte and IS. The MS–MS detection was by monitoring the fragmentation for drospirenone and for levonorgestrel on a triple quadrupole mass spectrometer. The assay was calibrated over the range 5–100 ng mL?1 with a correlation coefficient of 0.9998. Validation data showed intra-batch (n = 6) CV% ≤ 5.58 and RE (%) between ?3.34 and +6.27 and inter-batch (n = 18) CV% < 6.08 and RE (%) between ?1.84 and +6.73. Mean extraction recovery were 83.31–92.58% for three QC samples and 89.32% for IS. Plasma samples were stable for three freeze-thaw cycles, or 24 h ambient storage, or 1 and 3 months storage at ?20 °C. Processed samples (ready for injection) were stable up to 72 h at autosampler (4 °C). This method has been used for analyzing plasma samples from a bioequivalence study with 12 volunteers.  相似文献   

14.
15.
A rapid and sensitive LC?CMS?CMS method was developed for the quantification of amphotericin B in rabbit tears using natamycin as internal standard. The analyte and internal standard were extracted from the tear sample using a solid phase extraction method. Chromatographic separation was achieved on a Phenomenex Luna 3 ??m CN column (100 × 2 mm, 3 ??m) using 3.5 mM ammonium acetate (pH 4):methanol (10:90) as mobile phase. The assay was validated with a linear range of 0.1?C3.2 ??g mL?1 for amphotericin B using 10 ??L of tear sample. The intra- and inter-day assay precision ranged from 2.49 to 4.37 and 2.17 to 5.59%, respectively, and intra- and inter-day assay accuracy was between from 0.27 to 3.32 and ?0.51 to 3.72%, respectively. The method was successfully applied to the pharmacokinetic studies of amphotericin B eye drops in rabbit tears.  相似文献   

16.
A sensitive and specific liquid chromatography?Celectrospray ionization?Ctandem mass spectrometry method has been developed and validated for the identification and quantification of brivudine in human plasma using diclofenac as an internal standard. The method involves extraction with ethyl acetate. The analyte was separated on a C18 column and analyzed in multiple reaction monitoring mode with a negative electrospray ionization interface using the [M?CH]? ions, m/z 332.8??m/z 80.9 for brivudine, m/z 293.6??m/z 249.5 for diclofenac. The method was validated over the concentration range of 5.54?C2,836 ??g L?1 for brivudine. The intra-and inter-day precisions were less than 8.91% in terms of relative standard deviation (RSD), and the accuracy was within ?4.22% in terms of relative error (RE). The lower limit of quantification (LLOQ) was 5.54 ??g L?1 with acceptable precision and accuracy. There were almost no matrix effects. Recovery of brivudine spiked in drug-free plasma was higher than 77.17%. The method was used to study the pharmacokinetic profile of brivudine in human plasma after oral administration of brivudine tablets.  相似文献   

17.
A sensitive, specific, and rapid liquid chromatography?Celectrospray ionization?Ctandem mass spectrometry (LC?CESI?CMS?CMS) method was developed for determination of revaprazan in human plasma. Plasma samples were simply treated with methanol to precipitate, and then isolated supernatants were directly injected into the LC?CESI?CMS?CMS system. A Thermo Hypurity C18 column (150 × 2.1 mm, 5 ??m) with mobile phase of methanol?Cwater (70:30, v/v) containing 0.05% formic acid was used for chromatographic separation. Mass-spectrometric quantification was carried out in multiple reaction monitoring (MRM) mode, monitoring the m/z transitions 363.1 ?? 245.1 for revaprazan and 531.2 ?? 489.2 for ketoconazole (internal standard, IS) in positive ion mode. The linear calibration curves covered a concentration range of 2?C1,000 ??g L?1. The intra- and interday precisions (percentage relative standard deviation, RSD%) for revaprazan at three quality control levels were all <5%, and the accuracies were between 90% and 110%. The method has been successfully applied to a pharmacokinetic study involving 12 Chinese volunteers, and the main pharmacokinetic parameters of revaprazan in Chinese population are reported for the first time.  相似文献   

18.
A fast, sensitive, and specific LC?CMS?CMS method for determination of quinine (QN) and doxycycline (DOX) in rat plasma has been developed and validated. QN, DOX, and cimetidine (internal standard, IS) were extracted from the plasma by protein precipitation. The compounds were separated on a C18 column with methanol?C0.1% aqueous formic acid 70:30 (v/v) as mobile phase at a flow rate of 0.5 mL min?1 (split 1:3). Detection was by positive electrospray ionization (ESI+) in multiple reaction monitoring (MRM) mode, monitoring the transitions 325.0 ?? 307.0, 445.0 ?? 428.1, and 252.8 ?? 159.0, for QN, DOX, and IS, respectively. The analysis was carried out in 2.0 min and the method was linear in the plasma concentration range 5?C5,000 ng mL?1. The mean extraction recoveries for QN, DOX, and IS from plasma were 89.4, 90.5, and 86.3%, respectively. The method was validated for linearity, precision, accuracy, specificity, and stability; the results obtained were within the acceptable range. The proposed method was successfully applied to the determination of QN and DOX in rat plasma samples to support pharmacokinetic studies.  相似文献   

19.
A reversed-phase liquid chromatography coupled to tandem mass spectrometry (LC?CMS?CMS) method was developed and validated for the determination of fulvestrant in rat plasma. Sample preparation involved a liquid-liquid extraction using 1.0 mL of n-hexane?Cisopropanol (90:10, v/v) to extract the analyte from 0.1 mL of rat plasma. The analytes were separated on a phenyl-based column using the mobile phase consisting of methanol/water containing 5 mM ammonium acetate at the flow rate of 0.3 mL min?1. The analytes were monitored by tandem mass spectrometry under electrospray negative ionization mode. Linear calibration curves were generated over the fulvestrant concentration ranges of 0.05?C10.0 ng mL?1 in rat plasma. The accuracy and within- and between-day precisions were within the generally accepted criteria for bioanalytical methods (<15%). This developed and validated assay method was successfully employed to characterize the plasma concentration-time profile of fulvestrant after its intramuscular administration in rats at a dose of 10 mg kg?1.  相似文献   

20.
A sensitive, specific and rapid high performance liquid chromatography?Catmospheric pressure chemical ionization source-tandem mass spectrometry (LC-APCI-MS-MS) method for the determination of pilocarpine in human plasma was developed and validated. The method is based on liquid?Cliquid extraction, followed by a reversed-phase liquid chromatographic separation, and detected by means of tandem mass spectrometry. The linear calibration curve covered a concentration range of 2?C500 ??g L?1. The intra- and inter-day precisions for pilocarpine were <10% and the accuracies were between 90 and 110%. The method was applied successfully to a pharmacokinetic study involving 20 healthy Chinese male volunteers after oral administration of 6 mg pilocarpine.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号