首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel liquid chromatographic method has been developed and validated for the determination of ranolazine, its potential four impurities in drug substance and drug products. Efficient chromatographic separation was achieved on a C18 stationary phase (150 × 4.6 mm, 3.0 microns particles) with simple mobile phase combination delivered in gradient mode at a flow rate of 1.0 mL min?1 at 210 nm. In the developed method, the resolution between ranolazine and its four potential impurities was found to be greater than 2.0. Regression analysis shows an r value (correlation coefficient) greater than 0.999 for ranolazine and for its four impurities. This method was capable to detect all four impurities of ranolazine at a level below 0.004% with respect to test concentration of 1.0 mg mL?1 for a 10 μL injection volume. The method has shown good, consistent recoveries for ranolazine (98.8–101.1%) and for its four impurities (97.2–100.3). The test solution was found to be stable in the diluent for 48 h. The drug was subjected to stress conditions. The mass balance was found close to 99.5%.  相似文献   

2.
A new, sensitive, stability indicating gradient RP-LC related substances and assay method has been developed for the quantitative determination of entacapone in bulk drugs. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination of buffer and acetonitrile. Buffer consisted of 0.1% orthophosphoric acid, delivered in a gradient mode and quantitation was carried out using ultraviolet detection at 220 nm with a flow rate of 1.5 mL min?1. In the developed LC method the resolution (R s ) between entacapone and its three potential process impurities were found to be >2.0. Regression analysis showed an r 2 value (correlation coefficient) >0.99 for entacapone and its three potential impurities. This method was capable to detect all three process impurities of entacapone at a level of 0.003% with respect to test concentration of 0.5 mg mL?1 for a 20 μL injection volume. The inter- and intra-day precision values for all three impurities and for entacapone was found to be within 2.0% RSD. The method has shown good and consistent recoveries for entacapone in bulk drugs (99.2–101.5%) and its three impurities (99.5–102.2%). The test solution was found to be stable in diluent for 48 h. The drug substances were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress, base stress and oxidative conditions. The stressed test solutions were assayed against the qualified working standard of entacapone and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

3.
A novel, sensitive, stability indicating RP-LC method has been developed for the quantitative determination of deferasirox, its related impurities in both bulk drugs and pharmaceutical dosage forms. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in an isocratic mode and quantitation was by ultraviolet detection at 245 nm. The mobile phase consisted of buffer, acetonitrile and methanol (50:45:5, v/v) delivered at a flow rate of 1.0 mL min?1. Buffer consisted of 10 mM potassium dihydrogen orthophosphate monohydrate, pH adjusted to 3.0 by using orthophosphoric acid. In the developed LC method the resolution (R s ) between deferasirox and its four potential impurities was found to be greater than 2.0. Regression analysis showed an r value (correlation coefficient) greater than 0.999 for deferasirox and its four impurities. This method was capable to detect all four impurities of deferasirox at a level of 0.002% with respect to test concentration of 0.5 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precision values for all four impurities and for deferasirox was found to be within 2.0% RSD. The method showed good and consistent recoveries for deferasirox in bulk drugs (98.3–101.1%), pharmaceutical dosage forms (100.2–103.1%) and for its all the four impurities (99.7–102.1%). The test solution was found to be stable in methanol for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress hydrolysis. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.95%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

4.
A simple, sensitive isocratic rapid resolution liquid chromatographic assay method has been developed for the quantitative determination of quetiapine hemifumarate in bulk active pharmaceutical ingredient, used for the treatment of schizophrenia. The developed method is also applicable for the process related impurities determination. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a isocratic mode and quantification was by ultraviolet detection at 225 nm at a flow rate of 1.0 mL min?1. In the developed LC method the resolution between quetiapine hemifumarate and its three potential impurities was found to be greater than 2.0. Regression analysis showed an r value (correlation coefficient) greater than 0.99 for quetiapine hemifumarate and its three impurities. This method was capable to detect all three impurities of quetiapine hemifumarate at a level of 0.003% with respect to test concentration of 1.0 mg mL?1 for a 3 μL injection volume. The bulk active pharmaceutical ingredient was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in oxidative stress conditions. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.5%. The developed RR-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

5.

A new, sensitive, stability indicating gradient RP-LC related substances and assay method has been developed for the quantitative determination of entacapone in bulk drugs. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination of buffer and acetonitrile. Buffer consisted of 0.1% orthophosphoric acid, delivered in a gradient mode and quantitation was carried out using ultraviolet detection at 220 nm with a flow rate of 1.5 mL min−1. In the developed LC method the resolution (R s ) between entacapone and its three potential process impurities were found to be >2.0. Regression analysis showed an r 2 value (correlation coefficient) >0.99 for entacapone and its three potential impurities. This method was capable to detect all three process impurities of entacapone at a level of 0.003% with respect to test concentration of 0.5 mg mL−1 for a 20 μL injection volume. The inter- and intra-day precision values for all three impurities and for entacapone was found to be within 2.0% RSD. The method has shown good and consistent recoveries for entacapone in bulk drugs (99.2–101.5%) and its three impurities (99.5–102.2%). The test solution was found to be stable in diluent for 48 h. The drug substances were subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in acid stress, base stress and oxidative conditions. The stressed test solutions were assayed against the qualified working standard of entacapone and the mass balance in each case was close to 99.7% indicating that the developed method was stability-indicating. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.

  相似文献   

6.
A novel liquid chromatographic method has been developed, and validated for the determination of tolterodine tartarate, for its potential three impurities in drug substances and drug products. Efficient chromatographic separation was achieved on a C8 stationary phase (150 × 4.6 mm, 3.5 μm particles) with a simple mobile phase combination delivered in an isocratic mode at a flow rate of 0.8 mL min?1 and quantitation was carried out using ultraviolet detection. Microwave assisted degradation procedure was employed for stress testing studies in addition to the conventional way of a refluxing method. The results of both studies were compared. In the developed LC method, the resolution between tolterodine and its three potential impurities was found to be greater than 2.0. Regression analysis shows an r value (correlation coefficient) greater than 0.999 for tolterodine and for its three impurities. This method was capable to detect all three impurities of tolterodine at a level below 0.0038% with respect to a test concentration of 0.5 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precisions for all three impurities and for tolterodine were found to be within 1.1% RSD at its specification level. The method has shown good, consistent recoveries for tolterodine (98.9–101.6%) and for its three impurities (94.5–103.0%). The test solution was found to be stable in the diluent for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation, as prescribed by ICH. Degradation was found to occur in alkaline stress condition, while the drug was stable to water hydrolysis, acid hydrolysis, oxidative stress, photolytic and thermal stress. The assay of stressed samples was calculated against a qualified reference standard and the mass balance was found close to 99.5%. Microwave degradations were very fast and comparable to the conventional way of the refluxing method. Robustness studies were carried out and suggested that system suitability parameters were unaffected by small changes in critical factors. The validated method was successfully applied for the determination of tolterodine tartarate in drug substances and drug products.  相似文献   

7.
A simple reverse phase liquid chromatographic method was developed for the quantitative determination of desipramine hydrochloride and its related impurities in bulk drugs which is also stability-indicating. During the forced degradation at hydrolysis, oxidative, photolytic and thermal stressed conditions, the degradation results were only observed in the oxidative stress condition. The blend of the degradation product and potential impurities were used to optimize the method by an YMC Pack Pro C18 stationary phase. The LC method employs a linear gradient elution with the water–acetonitrile–trifluoroacetic acid as mobile phase. The flow rate was 1.0 mL min?1 and the detection wavelength 215 nm. The stressed samples were quantified against a qualified reference standard and the mass balance was found close to 99.0% (w/w) when the response of the degradant was considered to be equal to the analyte (i.e. desipramine). The developed RP-LC method was validated in agreement with ICH requirements.  相似文献   

8.
A novel, sensitive, stability-indicating gradient RP-LC method has been developed for quantitative analysis of balsalazide disodium and its related impurities both in the bulk drug and in pharmaceutical dosage forms. Efficient chromatographic separation was achieved on a C18 stationary phase with a simple mobile-phase gradient prepared from methanol and phosphate buffer (10 mm potassium dihydrogen orthophosphate monohydrate, adjusted to pH 2.5 by addition of orthophosphoric acid). The mobile-phase flow rate was 1.0 mL min?1. Quantification was achieved by use of ultraviolet detection at 240 nm. Under these conditions resolution of balsalazide disodium from its three potential impurities was greater than 2.0. Regression analysis resulted in a correlation coefficient greater than 0.99 for balsalazide disodium and all three impurities. This method was capable of detecting the three impurities at 0.003% of the test concentration of 0.3 mg mL?1, using an injection volume of 10 μL. Inter-day and intra-day precision for all three impurities and for balsalazide disodium was within 2.0% RSD. Recovery of balsalazide disodium from the bulk drug (99.2–101.5%) and from pharmaceutical dosage forms (99.8–101.3%), and recovery of the three impurities (99.1–102.1%) was consistently good. The test solution was found to be stable in 70:30 (v/v) methanol–water for 48 h. When the drug was subjected to hydrolytic, oxidative, photolytic, and thermal stress, acidic and alkaline hydrolysis and oxidizing conditions led to substantial degradation. The RP-LC method was validated for linearity, accuracy, precision, and robustness.  相似文献   

9.
A simple and sensitive liquid chromatography with ultraviolet detection (LC?CUV) method was developed for the determination of three impurities with a content over 0.1% (w/w) in technical triadimefon. A Gemini C18 column (5 ??m, 250 mm × 4.6 mm i.d.) was used for the chromatographic separations. The samples were separated by gradient elution with water (solvent A) and methanol (solvent B) using the following conditions: 70% A isocratic for 12 min, linear to 0% A within 8 min, and isocratic for 10 min at 0% A with a flow rate of 1.0 mL min?1. Chromatograms were recorded at an absorption wavelength of 280 nm. The chromatographic resolutions between triadimefon and its potential impurities A, B, and C were greater than 3. The developed LC method was validated with respect to linearity, accuracy, precision, and robustness. This method was successfully applied to analyze the impurities in commercial technical triadimefon. In addition, the structures of the three impurities were identified to be (A) 4-chlorophenol, (B) 1-(2,4-dichlorophenoxy)-3,3-dimethyl-1-(1H-1,2,4-triazol-1-yl)-2-butanone, and (C) 1,1-bis(4-chlorophenoxy)-3,3-dimethyl-2-butanone.  相似文献   

10.
A novel liquid chromatographic method for analysis three potential impurities in brimonidine tartrate drug substance has been developed and validated. Efficient chromatographic separation was achieved on a C8 column (250 mm × 4.6 mm, 5-μm particles) with a simple mobile-phase gradient at a flow rate of 1.0 mL min?1. Quantification was achieved by use of ultraviolet detection at 248 nm. Resolution between brimonidine tartrate and its three potential impurities was greater than 3.0. Regression analysis showed the r value (correlation coefficient) was >0.999 for brimonidine and its three impurities. The method was capable of detecting all three impurities of brimonidine tartrate at levels below 0.07 μg in a test concentration of brimonidine tartrate of 1.0 mg mL?1 and for an injection volume of 10 μL. A solution of brimonidine tartrate in acetonitrile–water 2:8 (v/v) was stable for 48 h. The drug was subjected to stress conditions as prescribed by the ICH. Degradation was found to occur slightly under oxidative stress conditions but the drug was stable to aqueous, acidic, and basic hydrolysis, and photolytic and thermal stress. The assay of the stressed samples was calculated relative to a qualified reference standard and the mass balance was found close to 99.8%. The method was validated for linearity, accuracy, precision, and robustness.  相似文献   

11.
A simple, sensitive gradient RP-LC assay method has been developed for the quantitative determination of amtolmetin guacyl in bulk drug, used as anti-inflammatory drug. The developed method is also applicable for related substances determination. Efficient chromatographic separation was achieved on a C18 stationary phase with simple mobile phase combination delivered in a gradient mode and quantification was carried out using ultraviolet detection at 313 nm at a flow rate of 1.0 mL min?1. In the developed LC method the resolution between Amtolmetin Guacyl and its three potential impurities was found to be greater than 2.0. Regression analysis shows an r value (correlation coefficient) greater than 0.99 for amtolmetin guacyl and its three impurities. This method was capable to detect all three impurities of amtolmetin guacyl at a level of 0.002% with respect to test concentration of 0.5 mg mL?1 for a 10 μL injection volume. The inter- and intra-day precision values for all three impurities and for amtolmetin guacyl was found to be within 2.0% RSD at its specification level. The method has shown good and consistent recoveries for amtolmetin guacyl (99.2–101.5%) and its three impurities (94.5–104.8%). The test solution was found to be stable in diluent for 48 h. The drug was subjected to stress conditions of hydrolysis, oxidation, photolysis and thermal degradation. Considerable degradation was found to occur in oxidative stress conditions. The stress samples were assayed against a qualified reference standard and the mass balance was found close to 99.6%. The developed RP-LC method was validated with respect to linearity, accuracy, precision and robustness.  相似文献   

12.
A novel liquid chromatographic method for the analysis of four potential impurities in the anti-cancer agent Bexarotene has been developed and validated using efficient chromatographic separation, achieved on a C18 column (50 mm × 2.1 mm, 1.7-μm particles) with a simple isocratic mobile phase at a flow rate of 0.5 mL min?1. The mobile phase consisted of a 70:30:0.1 (v/v/v) mixture of acetonitrile, water and trifluoroacetic acid, and quantification was achieved by use of ultraviolet detection at 260 nm. Resolution between Bexarotene and its four potential impurities was greater than 2.0. Regression analysis showed the r value (correlation coefficient) was >0.999 for Bexarotene and its four impurities. The method was capable of detecting all four impurities of Bexarotene at levels below 0.10 μg in a Bexarotene test concentration of 0.5 mg mL?1 using an injection volume of 5 μL. The recovery for Bexarotene in assay method at a 100% level was observed to be 99.1 ± 0.32% with % RSD value of 0.5% for drug substance and 98.9 ± 0.46% for Bexarotene capsules with % RSD value of 0.4%. Recovery of imp-1, imp-2, imp-3, and imp-4 from bulk drug samples ranged from 96.3 to 102.0%. Recovery of imp-1, imp-2, imp-3, and imp-4 from Bexarotene Capsule samples ranged from 97.2 to 101.4%. A solution of Bexarotene in ethanol was stable for 48 h. The drug was also subjected to stress conditions as prescribed by ICH Guidelines. Degradation was found to occur under acidic and basic hydrolysis stress conditions; however, the drug was stable to oxidative, photolytic, and thermal stress. Assay of the stressed samples was calculated relative to a qualified reference standard and the mass balance was found to be close to 99.8%. The method was validated for linearity, accuracy, precision, and robustness.  相似文献   

13.
A gradient HPLC method coupled with diode array detection was developed and fully validated for the analysis of impurities in ropinirole using a Kromasil® C8 100 Å (250 × 4.6 mm, 5 μm) column with a flow rate 1.0 mL min?1 and detection at 250 nm. The mobile phase component A consisted of a mixture of 19.6 mM aqueous potassium dihydrogen phosphate–acetonitrile (98:2 v/v), pH adjusted to 7.0 with triethylamine and the mobile phase component B consisted of acetonitrile. The method was validated in terms of linearity, sensitivity, precision, accuracy and stability. The calibration curves for ropinirole and its five impurities showed good linearity (r > 0.998) within the calibration ranges tested. The intra- and inter-day RSD values were <3.9 %, while the relative percentage error E r was <5.8 % for all compounds. Accelerated stability studies performed under various stress conditions including oxidation, hydrolysis and UV light irradiation at 254 nm proved the selectivity of the procedure. Long-term stability studies performed on blistered tablets and under various conditions of heat and humidity indicate the presence of four of the studied impurities in less than 0.07 %. The method was applied successfully to the detection and determination of ropinirole impurities in pharmaceutical formulations.  相似文献   

14.
A simple, fast, inexpensive capillary zone electrophoresis method for the separation and determination of tiapride hydrochloride and its two related impurities in pharmaceutical formulations has been developed and validated. The successful separation of these compounds was achieved in less than 3 min using a fused silica capillary and photodiode array detector at 218 nm. The best conditions were obtained using a 10 mM sodium tetraborate (pH 8.0) as the running buffer. The linear responses covered the ranges from 1.0 to 100 μg mL?1 (R = 0.9989) for tiapride hydrochloride. The detection (LOD) and quantitation limits (LOQ) for tiapride hydrochloride were 2.7 and 9.0 μg mL?1, respectively. The intra- and inter-day relative standard deviations for migration times and peak areas were less than 0.47 and 5.7%, respectively. The method was validated for the determination of tiapride hydrochloride in commercial tablets.  相似文献   

15.
Six related substances were detected in diosmin bulk drug substances and products by a newly developed gradient reverse-phase high performance liquid chromatography (RP-HPLC) with UV detection. The chromatographic system consisted of an Intersil Wondasil TM ODS (C 18) column (250 × 4.6 mm; 5 μm). The mobile phase consisted of water/acetic acid 66:6 v/v (solvent A) and methanol (solvent B) using a gradient program at a flow rate of 0.8 mL min?1 with 345 nm detection and an injection volume of 20 μL. In addition, the linearity, quantitation limit (QL), accuracy, selectivity, robustness and precision were determined. Good linearity was obtained over the concentration range 0.5–200 μg mL?1 with the coefficient of determination (r 2) of 0.999. The QL was 0.125 μg mL?1 (relative standard deviation <2.0 %). The major impurities have been resolved and identified using two analytical systems, HPLC and HPLC/electrospray ionization-mass spectrometry operated in a negative ion mode. One of these impurities marked as 7-hexopyranosidal diosmetin was unknown and has not been reported previously. Based on mass spectrometry data the structure of the new impurity was proposed as 5-hydroxy-2-(3-hydroxy-4-methoxyphenyl)-4-oxo-4H-chromen-7-yl hexopyranoside. The newly developed RP–LC method for quantitative determination of diosmin-related substances was found to be precise, accurate, robust and specific. It has been successfully employed for the quality evaluation of different sources of raw material and generic formulations of diosmin.  相似文献   

16.

A simple reverse phase liquid chromatographic method was developed for the quantitative determination of desipramine hydrochloride and its related impurities in bulk drugs which is also stability-indicating. During the forced degradation at hydrolysis, oxidative, photolytic and thermal stressed conditions, the degradation results were only observed in the oxidative stress condition. The blend of the degradation product and potential impurities were used to optimize the method by an YMC Pack Pro C18 stationary phase. The LC method employs a linear gradient elution with the water–acetonitrile–trifluoroacetic acid as mobile phase. The flow rate was 1.0 mL min−1 and the detection wavelength 215 nm. The stressed samples were quantified against a qualified reference standard and the mass balance was found close to 99.0% (w/w) when the response of the degradant was considered to be equal to the analyte (i.e. desipramine). The developed RP-LC method was validated in agreement with ICH requirements.

  相似文献   

17.
18.
A fast, selective and sensitive reversed phase liquid chromatographic method employing a C-18 column has been developed and validated for simultaneous analysis of four impurities of duloxetine hydrochloride, an antidepressant drug, viz., (S)-N,N-dimethyl-3-hydroxy-(2-thienyl)-propanamine, phenolic impurity, 1-napthol and duloxetine succinamide. Good separations were achieved by a gradient elution with mobile phase consisting of a mixture of phosphate buffer 14 mM containing 0.1% of sodium octanesulfonate, pH 3.0, at a flow rate of 0.8 mL min?1. The detection was at 220 nm. The method was validated for precision, linearity and accuracy. Finally, the developed method was used to quantify the impurities during stability sample analysis of duloxetine hydrochloride drug products.  相似文献   

19.
《Analytical letters》2012,45(6):970-982
A simple, rapid, and automated method for the spectrophotometric determination of flavonoids in medicinal plants was developed using a stepwise injection manifold. The determination was based on formation of colored complexes of flavonoids with Al(III) in micellar media. Analytical characteristics of the determination were significantly improved when cetylpyridinium chloride was used as a micellar catalyst. It was found that the rate of colored complex formation of rutin with Al(III) increased (k = (1.8 ± 0.1) · 104 min?1mol?2 L2) in the presence of cetylpyridinium chloride. Under the optimum conditions, a linear response was found from 0.004 to 0.2% (volume of weight %). The detection limit (3s) was determined as 0.001% rutin versus the weight of the sample. The developed method was used for the analysis of different medicinal plants for flavonoids.  相似文献   

20.
Madhavi  A.  Naidu  A.  Subba Rao  D. V.  Srinivasu  P. 《Chromatographia》2009,69(11):1413-1419

A novel liquid chromatographic method for analysis three potential impurities in brimonidine tartrate drug substance has been developed and validated. Efficient chromatographic separation was achieved on a C8 column (250 mm × 4.6 mm, 5-μm particles) with a simple mobile-phase gradient at a flow rate of 1.0 mL min−1. Quantification was achieved by use of ultraviolet detection at 248 nm. Resolution between brimonidine tartrate and its three potential impurities was greater than 3.0. Regression analysis showed the r value (correlation coefficient) was >0.999 for brimonidine and its three impurities. The method was capable of detecting all three impurities of brimonidine tartrate at levels below 0.07 μg in a test concentration of brimonidine tartrate of 1.0 mg mL−1 and for an injection volume of 10 μL. A solution of brimonidine tartrate in acetonitrile–water 2:8 (v/v) was stable for 48 h. The drug was subjected to stress conditions as prescribed by the ICH. Degradation was found to occur slightly under oxidative stress conditions but the drug was stable to aqueous, acidic, and basic hydrolysis, and photolytic and thermal stress. The assay of the stressed samples was calculated relative to a qualified reference standard and the mass balance was found close to 99.8%. The method was validated for linearity, accuracy, precision, and robustness.

  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号