1.
For the separation of peptides with gradient-elution liquid chromatography a poly(butyl methacrylate-co-ethylene dimethacrylate) (BMA) monolithic capillary column was prepared and tested. The conditional peak capacity was used as a metric for the performance of this column, which was compared with a capillary column packed with C18-modified silica particles. The retention of the peptides was found to be smaller on the BMA column than on the particulate C18 column. To obtain the same retention in isocratic elution an approximately 15% (v/v) lower acetonitrile concentration had to be used in the mobile phase. The retention window in gradient elution was correspondingly smaller with the BMA column. The relation between peak width and retention under gradient conditions was studied in detail. It was found that in shallow gradients, with gradient times of 30min and more, the peak widths of the least retained compounds are strongly increased with the BMA column. This was attributed to the fact that these compounds migrate and elute with an unfavorable high retention factor. More retained compounds are eluted later in the gradient, but with a lower effective retention factor. With shallow gradients the peak capacity of the BMA column ( approximately 90) was clearly lower than that of a conventional packed column ( approximately 150). On the other hand, with steep gradients, when components elute with a low effective retention factor, the performance of the BMA column is relatively good. With a gradient time of 15min similar peak widths and thus similar peak capacities ( approximately 75) were found for the packed and the monolithic column. Two strategies were investigated to obtain higher peak capacities with methacrylate monolithic columns. The use of lauryl methacrylate (LMA) instead of butyl methacrylate (BMA) gave an increase in retention and narrower peaks for early eluting peptides. The peak capacity of the LMA column was approximately 125 in a 60min gradient. Another approach was to use a longer BMA column which resulted in a peak capacity of approximately 135 could be obtained in 60min.  相似文献   

2.
A new approach to high speed, comprehensive online dual gradient elution 2DLC (LCxLC) based on the use of ultra-fast, high temperature gradient elution reversed phase chromatography is described. Entirely conventional gradient elution instrumentation and columns are assembled in a system which develops a total peak capacity of about 900 in 25 min; this is equivalent to roughly one peak/2 s. Each second dimension gradient is done in a cycle time of 21 s and the peak retention times measured for a set of twenty six indole-3-acetic acid (IAA) derivatives are reproducible to 0.2 s. Each peak eluting from the first dimension column is sampled at least twice across its width, as the corresponding peaks on the second dimension column appear in two or three consecutive second dimension chromatograms, clearly indicating that there is little loss in the resolution gained in the first dimension separation. Application to the separation of the low molecular weight components of wild-type and mutant maize seedlings indicates the presence of about 100 peaks on a timescale of 25 min. Compelling illustrations of the analytical potential of fast, high temperature 2DLC are evident in the clear presence of nine distinct peaks in a single second dimension chromatogram from a single quite narrow first dimension peak, and the great power of 2DLC to solve the "analytic dynamic range" problem inherent in the measurement of small peaks that are neighbors to a gigantic peak.  相似文献   

3.
Gradient elution provides significantly higher peak capacity in comparison to the isocratic elution mode, hence it is very useful in online comprehensive two-dimensional liquid chromatography (LC). We compared suitability of five commercial core-shell columns and one monolithic column for fast gradients in the second LC dimension, where the time of separation is strictly limited by the fraction cycle time. In two-dimensional reversed-phase systems with partially correlated retention, the resolution, the peak capacity, and the regularity of coverage of the second-dimension retention space can be improved by appropriate adjusting the gradient time and the gradient range to suit the sample properties. We developed a new strategy for adjusting the gradient mobile phase composition range in the second-dimension, employing the retention data of representative sample standards characterizing the sample properties, which can be calibrated using the reference alkylbenzene series. Optimized second-dimension gradients with single-step or segmented profiles covering two or more fraction ranges, employed for the separation of subsequent fractions from the first-dimension, improve significantly the resolution, the separation time, and the regularity of coverage of the two-dimensional retention plane. The approach was applied to the two-dimensional comprehensive separation of phenolic acids and flavonoid compounds occurring as natural antioxidants.  相似文献   

4.
The mixed-mode separation of a selection of anionic and cationic pharmaceutically related compounds is studied using ion-exchange columns and eluents consisting of ionic salts (potassium hydroxide or methanesulfonic acid) and an organic modifier (methanol). All separations were performed using commercially available ion-exchange columns and an ion chromatography instrument modified to allow introduction of methanol into the eluent without introducing compatibility problems with the eluent generation system. Isocratic retention prediction was undertaken over the two-dimensional space defined by the concentration of the competing ion and the percentage of organic modifier in the eluent. Various empirical models describing the observed relationships between analyte retention and both the competing ion concentration and the percentage of methanol were evaluated, with the resultant model being capable of describing the separation, including peak width, over the entire experimental space based on six initial experiments. Average errors in retention time and peak width were less than 6% and 27%, respectively, for runs taken from both inside and outside of the experimental space. Separations performed under methanol gradient conditions (while holding the competing ion concentration constant) were also modelled. The observed effect on retention of varying the methanol composition differed between analytes with several analytes exhibiting increased retention with increased percentage methanol in the eluent. An empirical model was derived based on integration of the observed tR vs. %methanol plot for each analyte. A combination of the isocratic and gradient models allowed for the prediction of retention time using multi-step methanol gradient profiles with average errors in predicted retention times being less than 4% over 30 different 2- and 3-step gradient profiles for anions and less than 6% over 14 different 2- and 3-step gradient profiles for cations. A modified peak compression model was used to estimate peak widths under these conditions. This provided adequate width prediction with the average error between observed and predicted peak widths being less than 15% for 40 1-, 2- and 3-step gradients for anions and less than 13% over 14 1-, 2- and 3-step gradients for cations.  相似文献   

5.
6.
7.
The prediction of the peak width at half height is an important aspect in the optimization of the chromatographic operating conditions. In this paper, a linear relationship, between the peak widths at half height and the retention values with various isocratic elution is observed. In gradient elution, however, the relationship between the peak widths at half height and the so-called invented retention values that correspond to the mobile phase composition by eluting the solute from the column end is developed. We believe that there is almost the same band width at half height inside the column (in unit of length) for different solutes. The peak width at half height in the chromatogram (in unit of time) is mainly determined by the capacity factor of the solute when it is eluted from the column end. The larger the capacity factor of a solute eluted from the column end, the more slowly will be the solute eluted from the column end and the wider will be the peak width at half height. It is possible to predict the peak width at half height in various isocratic and gradient elutions by using this linear relationship.  相似文献   

8.
Reversed-phase ultra-performance liquid chromatography was used for biopolymer separations in isocratic and gradient mode. The gradient elution mode was employed to estimate the optimal mobile phase flow rate to obtain the best column efficiency and the peak capacity for three classes of analytes: peptides, oligonucleotides and proteins. The results indicate that the flow rate of the Van Deemter optimum for 2.1 mm I.D. columns packed with a porous 1.7 microm C18 sorbent is below 0.2 mL/min for our analytes. However, the maximum peak capacity is achieved at flow rates between 0.15 and 1.0 mL/min, depending on the molecular weight of the analyte. The isocratic separation mode was utilized to measure the dependence of the retention factor on the mobile phase composition. Constants derived from isocratic experiments were utilized in a mathematical model based on gradient theory. Column peak capacity was predicted as a function of flow rate, gradient slope and column length. Predicted peak capacity trends were compared to experimental results.  相似文献   

9.
Summary A method of reserved-phase HPLC analysis for mixtures of triglycerides (TG's) that provides good resolution at acceptable analysis times for high-ECN TG's has been developed. An elution gradient of methyltert-butyl-ether (MTBE) in acetonitrile (ACN) was used with an ultraviolet detector operated at 215nm. The effect of the proportion of MTBE in the mobile phase, gradient time, temperature and sample solvent on TG retention and resolution was studied. Linear relationships were derived between the logarithm of the capacity factor (log k'), and the logarithm of selectivity (log α) and the above-mentioned chromatographic factors. The conditions selected were: an elution gradient of from 23 to 30% MTBE, an elution gradient time of 25 minutes, and a temperature of 30°C, which provided good resolution of soybean oil TG's in less than 30 minutes.  相似文献   

10.
Peak capacity is the commonly used measure of separation efficiency in gradient elution. This study focuses on the effect of column characteristics (particle size and column length) and operating parameters (gradient time and flow rate) on the peak capacity for small molecule compounds in gradient elution. The goal of this study is to develop a practical strategy to maximize the separation efficiency (i.e., peak capacity) under different constraints (analysis time or pressure limit). Using both experimental data and theoretical modeling, the current study reveals that the peak capacity increases with both gradient time and column length in a non-linear fashion. Marginal peak capacity is proposed to characterize the non-linear increase of peak capacity over the gradient time and column length. This study also attempts to understand the maximum peak capacity achievable under certain pressure limits using Neue’s peak capacity model. The results of this study provide a better understanding of the UPLC technology, and can also help to develop practical strategies to maximize the separation efficiency in gradient elution to meet the separation needs.  相似文献   

11.
Isotope separation utilizing ionization control in reversed-phase liquid chromatography was studied. Several organic acids and bases labeled with oxygen-18 and nitrogen-15 were successfully separated from unlabeled compounds by using either 6-m microbore columns or recycle chromatography with short columns of conventional size. Differences in the separation factors for the same isotopic mixtures were observed between the two chromatographic systems, and attributed to the difference in the pressure gradient along the columns in the two systems. The steep pressure gradient existing in the short recycle columns resulted in an increase in the peak width and the separation factor for oxygen isotopic compounds, and a decrease in the peak width and the separation factor for nitrogen isotopic compounds.  相似文献   

12.
A theoretical study on the retention behaviour and chromatographic performance of neutral solutes using a lauryl methacrylate‐based monolithic column under voltage gradient mode in CEC was carried out. Through a flexible mathematical function based on a modified Gaussian model, the peak shape of compounds was firstly fitted under constant and gradient voltage. Using the peak shape parameters and retention time, the estimation of global chromatographic performance, efficiency and peak capacity under several voltage conditions was performed. The influence of voltage gradient on the separation efficiency is discussed and simple equations are presented to calculate retention and peak widths under voltage gradient conditions. A comparison in terms of chromatographic performance of a test mixture of neutral solutes under constant and gradient voltage modes was also carried out. The experiments carried out under gradient voltage showed better efficiencies (172 000 plates/m) and lower peak widths than those obtained under constant voltage (52 000 plates/m).  相似文献   

13.
Chromatographers are cautioned to avoid gradient elution when isocratic elution will do. In this work, we compared the analytical properties of gradient and isocratic separations of a sample which can be done quite readily under isocratic conditions. We found that gradient elution gave a shorter overall analysis with similar resolution of the critical pair compared to isocratic elution without sacrificing repeatability in retention time, peak area and peak height or linearity of the calibration curve. We also obtained acceptable repeatability in peak area/height and linearity of calibrations curves for a sample that required gradient elution using a practical baseline subtraction technique. Based on these results and related work which show that columns can be reequilibrated by flushing with less than two column volumes of the initial eluent, we conclude that many of the reasons given to avoid gradient elution deserve serious reconsideration, especially for those samples which are easily separated isocratically. However, we believe isocratic elution will remain preferable when: (1) the sample contains less than 10 weakly retained components (i.e. the last peak elutes with k' < 5) or (2) the gradient baseline impedes trace analysis.  相似文献   

14.
A new approach for the high-throughput screening of biological samples to detect the presence of regulated intoxicants has been developed by modifying a conventional gradient elution high-performance liquid chromatograph (HPLC). The goal of this work was to improve the speed of gradient elution screening methods over current approaches by optimizing the operational parameters of both the column and the instrument without compromising the reproducibility of the retention times, which is the basis for the identification of intoxicant compounds. Most importantly, the novel instrument configuration substantially reduces the time needed to re-equilibrate the column between consecutive gradient runs, thereby reducing the total time for each analysis. The total analysis time for each gradient elution run is only 2.80 min, including 0.30 min for column re-equilibration between analyses. Retention times of standard calibration solutes are reproducible to better than 0.002 min in consecutive runs. A corrected retention index was adopted to account for day-to-day and column-to-column variations in retention time. For a set of forty-seven target compounds, the discriminating power and mean list length were found to be 0.95 and 3.26, respectively. In comparison to previous work with similar numbers of target compounds, the current approach provides an order of magnitude improvement in analysis time, and a four-fold decrease in mean list length.  相似文献   

15.
A novel graphical method for assessing the compromise between conditional peak capacity and separation speed for packed bed columns under gradient conditions has been developed and applied to the separation of peptides. This approach is analogous to and complements the conventional "Poppe plot" used to study plate count in isocratic separations. The use of the new plot can assist the design of appropriate column formats (e.g. particle size and column length) for both dimensions in gradient elution two-dimensional liquid chromatography (2DLC). Particularly for the second dimension of 2DLC, we find that smaller particles provide faster separations even though fast separations based on particles smaller than 2 microm are practically limited by the required miniscule column length. We also find that high temperatures strongly enhance the kinetics of peak capacity production whereas higher pressures help achieve larger absolute peak capacities albeit at the cost of longer analysis time.  相似文献   

16.
We characterized thermally polymerized organo-silica hybrid monolithic capillaries to test their applicability in the gradient elution of peptides. We have used a single-pot approach utilizing 3-(methacryloyloxy)propyltrimethoxysilane (MPTMS), ethylene dimethacrylate (EDMA), and n-octadecyl methacrylate (ODM) as functional monomers. The organo-silica monolith containing MPTMS and EDMA was compared with the stationary phase prepared by adding ODM to the original polymerization mixture. Column prepared using a three-monomer system provided a lower accessible volume of flow-through pores, a higher proportion of mesopores, and higher efficiency. We utilized isocratic and gradient elution data to predict peak widths in gradient elution. Both protocols provided comparable results and can be used for peptide peak width prediction. However, applying gradient elution data for peak width prediction seems simpler. Finally, we tested the effect of gradient time on achievable peak capacity in the gradient elution of peptides with a column prepared with a three-monomer system providing a higher peak capacity. However, the performance of hybrid organo-silica monolithic stationary phases in gradient elution of peptides must be improved compared to other monolithic stationary phases. The limiting factor is column efficiency in highly aqueous mobile phases, which needs to be focused on.  相似文献   

17.
A gradient kinetic plot method is used for theoretical characterisation of the performance of polymeric particulate anion exchange columns for gradient separations of small inorganic anions. The method employed requires only information obtained from a series of isocratic column performance measurements and in silico predictions of retention time and peak width under gradient conditions. Results obtained under practically constrained conditions provide parameters for the generation of high peak capacities and rapid peak production for fast analysis to be determined. Using this prediction method, a maximum theoretical peak capacity of 84 could be used to achieve separation of 26 components using a 120 min gradient (Rs > 1). This approach provides a highly convenient tool for development of both mono- and multidimensional ion chromatography (IC) methodologies as it yields comprehensive understanding of the influence of gradient slope, analysis time, column length and temperature upon kinetically optimised gradient performance.  相似文献   

18.
The type of the stationary phase for reversed-phase liquid chromatography significantly affects the sample polarity range that can be covered using gradients of organic solvents in water. The polarity range available for gradient separations of samples containing compounds differing in the lipophilic parts of the molecules can be characterized by "gradient lipophilic capacity", Pl, based on the retention of standard compounds with a repeat lipophilic structural unit, such as a methylene group. The gradient lipophilic capacity is also suitable to characterize the separation possibilities of the columns in non-aqueous reversed-phase gradient elution of strongly non-polar compounds, such as triacylglycerols. In the same way, the suitability of various columns for reversed-phase gradient separations of oligomers can be characterized by "gradient oligomer capacity", as demonstrated in the example of oligo(ethylene glycols). To enable a comparison of the properties of stationary phases independent of column efficiency and dimensions, the gradient lipophilic capacity or the gradient oligomer capacity should be normalized for a "standard" column plate number, gradient range and volume (in column hold-up volume units). The gradient lipophilic capacity or the gradient oligomer capacity and the number of compounds that can be resolved during a gradient run decrease as the initial concentration of the strong solvent in the mobile phase increases and (or) the gradient time decreases. These quantities can be used to select a suitable column and to adjust the optimum gradient profile (the initial composition of the mobile phase and the gradient steepness) with respect to the time of analysis and the number of oligomers or other compounds with regular repeat structural groups that can be resolved during the gradient run.  相似文献   

19.
The chromatographic method for the determination of the intermolecular acetyl distribution of cellulose triacetate (CTA) was established; the key point of the method is a gradient elution by gradually changing the solvent composition of the ternary mixture of chloroform, methanol, and water on a phenyl-bonded silica gel stationary phase. A positive correlation between the retention time and the degree of acetyl substitution was observed under the established chromatographic conditions. The validity of the elution peak width as the measure of intermolecular acetyl distribution was confirmed by the co-injection and fractionation experiments and the comparison of a peak width with a statistically estimated distribution.  相似文献   

20.
The tandem use of hydrophilic interaction LC columns with RP columns in series configuration has resulted in the retention of both polar and nonpolar components in complex biological samples (mouse serum) in a single analysis. This approach successfully coupled various columns with orthogonal separation characteristics, employed a single solvent gradient program compatible with the two columns and used ESI coupled to a TOF mass spectrometer for detection. Ion suppression, a common problem in ESI, was virtually eliminated for components eluting with apparent capacity factors >0.7. Retention time reproducibility with the tandem columns performed over three days with over 100 injections was comparable to that observed for single columns alone. This method was applied to the analysis of a pooled mouse serum sample and afforded highly reproducible data for up to 3000 mass spectral features. This approach was implemented with a conventional LC–MS system and should find broad applicability in the comprehensive analysis of complex mixtures containing a wide range of compound polarities.  相似文献   