共查询到20条相似文献,搜索用时 15 毫秒
1.
Dun-Jian Wang Da-Wei Wang Qiu-Chen Fang Ye Shen Nv-Jin Zeng Yan-Ling Yang Hong-Wen Zhang Yong-Qing Wang Lu-Ning Sun 《Journal of separation science》2022,45(6):1146-1152
Regadenoson, the first selective adenosine A2A receptor agonist, is used to perform exercise stress test during radionuclide myocardial perfusion imaging. To detect the concentration of regadenoson in human plasma, a simple, fast, and sensitive tandem mass spectrometry method was established herein. Acetonitrile was used as a protein precipitation agent. Chromatographic separation was completed in 6.5 min using a BEH HILIC column (50 × 2.1 mm, 1.7 μm). The mobile phase consisted of 10 mmol/L ammonium acetate/acetonitrile (gradient elution). To quantify regadenoson and regadenoson-d3, an API 4000 mass spectrometry in multiple reaction monitoring mode with transitions of 391.3→259.2 and 394.3→262.2, respectively, was utilized. The calibration curve was linear in the range of 0.100–50.0 μg/L, and the intrabatch and interbatch precisions were <9.7% and <13.0%, respectively, and the accuracy was 2.0–6.9%. There was no apparent matrix effect for regadenoson or regadenoson-d3. The developed method was used to study the pharmacokinetic characteristics of regadenoson in healthy Chinese subjects. 相似文献
2.
Haidong Wang Pan Deng Xiaoyan Chen Lixia Guo Dafang Zhong 《Biomedical chromatography : BMC》2013,27(1):34-38
A rapid and sensitive analytical method based on liquid chromatography coupled to tandem mass spectrometry detection with positive ion electrospray ionization was developed for the determination of febuxostat in human plasma using d7‐febuxostat as the internal standard (IS). A simple protein precipitation was performed using acetonitrile. The analyte and IS were subjected to chromatographic analysis on a Capcell PAK C18 column (4.6 × 100 mm, 5 µm) using acetonitrile–5 mm ammonium acetate–formic acid (85:15:0.015, v/v/v) as the mobile phase at a flow rate of 0.6 mL/min. An Agilent 6460 electrospray tandem mass spectrometer was operated in the multiple reaction monitoring mode. The precursor‐to‐product ion transitions m/z 317 → m/z 261 (febuxsotat) and m/z 324 → m/z (261 + 262) (d7‐febuxostat, IS) were used for quantitation. The results were linear over the studied range (10.0–5000 ng/mL), and the total analysis time for each chromatograph was 3 min. The intra‐ and inter‐day precisions were less than 7.9 and 7.2%, respectively, and the accuracy was within ±4.2%. No evidence of analyte instability in human plasma was observed storage at ?20°C for 31 days. This method was successfully applied in the determination of febuxostat concentrations in plasma samples from healthy Chinese volunteers. Copyright © 2012 John Wiley & Sons, Ltd. 相似文献
3.
Weizhu Chen Yiping Zhang Hua Fang Hui Chen Jianlin He Ruizao Yi Zhuan Hong 《Biomedical chromatography : BMC》2020,34(9):e4900
Tetrodotoxin (TTX) exhibits the therapeutic potential in blocking pain and in low doses can safely relieve severe pain. The urinary excretion profiles of TTX in humans have not been reported due to the extremely low lethal dose. In this study, a rapid and specific method based on protein precipitation coupled to liquid chromatography tandem mass spectrometry was developed to determine the level of TTX in human urine samples. 11-Deoxytetrodotoxin was used as an internal standard (IS). Multiple reaction monitoring mode was used for quantification using target fragment ions m/z 320.0 → 162.1 for TTX and m/z 304.0 → 176.0 for 11-deoxyTTX. The separation of analytes was achieved on a hydrophilic interaction liquid chromatography column (250 × 4.6 mm, 5.0 μm). The mobile phase consisted of 5 mM ammonium formate in water (pH = 4.50) and 5 mM ammonium formate in acetonitrile (pH = 4.50). The flow rate was set at 0.80 mL/min in a gradient condition. Calibration plots were linear throughout the range 0.986–98.6 ng/mL of TTX in human urine. The intra-assay accuracies and precisions were within the acceptable range. The method was successfully applied to a urinary excretion study after intravenous administration of TTX to healthy volunteers. The developed method will be helpful for future pharmacological studies of TTX. 相似文献
4.
《Biomedical chromatography : BMC》2018,32(8)
Pteridines and their derivatives are important cofactors in the process of cell metabolism, and the level of urinary excretion of these compounds is considered as an important clinical criterion. In this work, a new separation method involving hydrophilic interaction chromatography (HILIC) with tandem mass spectrometric detection has been developed for the simultaneous analysis of 12 pteridines including oxidized, di‐ and tetrahydroforms, namely neopterin, 7,8‐dihydroneopterin, biopterin, 7,8‐dihydrobiopterin, 5,6,7,8‐tetrahydrobiopterin, dimethylpterin, dimethyltetrahydropterin, pterin, isoxanthopterin, xanthopterin, sepiapterin and pterin‐6‐carboxylic acid, in human urine without oxidative pretreatments. The stabilizing agent (dithiothreitol) at various concentrations and the stability of oxidized, di‐ and tetrahydroforms during the sample's short‐term storage and processing and of the extracts were tested. In the developed method, 12 pteridines were chromatographically separated on an ZIC‐HILIC column by gradient elution, and the run time was 20 min. Matrix effect was evaluated and several dilutions of urine were tested in order to study the evolution of signal suppression. Spiked recovery studies demonstrated that the technique was both accurate (83.1–116.7%) and precise (RSD 1.4–15.6%). Finally, several clinical urine specimens without oxidative pretreatments were examined with the new technique and compared with previous reports. 相似文献
5.
建立了测定人尿液中尼古丁和可替宁含量的亲水作用色谱-串联质谱(HILIC-MS/MS)方法。尿样加入尼古丁-d4和可替宁-d3同位素内标后,用水稀释10倍,经过滤后的滤液由超高效液相色谱-串联质谱(UPLC-MS/MS)进行分离分析。采用ACQUITY UPLC~BEH HILIC色谱柱(50 mm×3.0 mm,1.7μm),以甲醇和体积分数为0.1%的氨水为流动相,流速为0.2 mL/min,在电喷雾电离源正离子模式下测定尿液中尼古丁和可替宁的含量,用标准曲线法定量。尼古丁和可替宁在1.0~1 000μg/L范围内线性关系良好,相关系数分别为0.994 9和0.995 8;检出限分别为0.082μg/L和0.077μg/L;定量限分别为0.27μg/L和0.26μg/L;加标回收率分别为90.4%~103.5%和93.0%~104.6%;相对标准偏差分别为4.80%~6.21%和4.22%~7.15%。应用所建立的方法测定了200份尿样,结果表明,吸烟人群尿中尼古丁含量为26.68~854.30μg/L,可替宁含量为36.66~1 191.18μg/L(n=86,M_(nicotine)=76.00μg/L,M_(nicotine)=83.52μg/L,M为中位数);非吸烟人群尿中尼古丁含量为5.08~69.66μg/L,可替宁含量为3.16~28.21μg/L(n=114,Mnicotine=7.53μg/L,M_(nicotine)=3.79μg/L)。该方法快速灵敏,操作简单,适用于尿样中尼古丁和可替宁的批量测定,能满足烟草暴露评价的需要。 相似文献
6.
Tanja Vnučec Popov Lea Cvitkovič Maričič Helena Prosen Darinka Brodnjak Vončina 《Biomedical chromatography : BMC》2013,27(8):1054-1061
An LC‐MS/MS method for determination of the anti‐epileptic drug topiramate (TPM) in dried blood spot (DBS) samples was developed and validated. DBS samples were prepared by spotting 30 μL of spiked whole blood onto FTATM DMPK‐C cards and drying for at least 3 h. Six‐millimetre punched spots were then extracted by using a mixture of methanol and water (90:10, v/v) with deuterated internal standard (topiramate‐d12). The extracted samples were injected into a liquid chromatograph equipped with a tandem mass spectrometric detector. Negative ions were monitored in the selected reaction monitoring mode and transitions m/z 338.2 → 78.1 and m/z 350.3 → 78.1 were used for the quantitative evaluation of TPM and internal standard, respectively. The results obtained from validation were statistically evaluated according to the requirements of the European Medicines Agency and US Food and Drug Administration regulatory guidelines. The linearity of the method was checked within a concentration range from 10 to 2000 ng/mL. The validation results indicate that the method is accurate, precise, sensitive, selective and reproducible. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
7.
Yongqing Wen Xuemei Yuan Feng Qin Longshan Zhao Zhili Xiong 《Biomedical chromatography : BMC》2019,33(1)
Determination of amino acids in biofluids is a challenging task because of difficulties deriving from their high polarity and matrix interference. A simple, reliable and high‐throughput hydrophilic interaction UHPLC–MS/MS method was developed and validated for the rapid simultaneous determination of 19 free amino acids in rat plasma and urine samples in this paper. Hydrophilic method with a Waters Acquity UPLC BEH Amide column (100 × 2.1 mm,1.7 μm) was used with a gradient mobile phase system of acetonitrile and water both containing 0.2% formic acid. The analysis was performed on a positive electrospray ionization mass spectrometer via multiple reaction monitoring. Samples of 10 μL plasma and 50 μL urine were spiked with three deuterated internal standards, pretreated with 250 μL acetonitrile for one‐step protein precipitation and a final dilution of urine samples. Good linearities (r > 0.99) were obtained for all of the analytes with the lower limit of quantification from 0.1 to 1.2 μg/mL. The relative standard deviation of the intra‐day and inter‐day precisions were within 15.0% and the accuracy ranged from ?12.8 to 12.7%. The hydrophilic interaction UHPLC–MS/MS method was rapid, accurate and high‐throughput and exhibited better chromatography behaviors than the regular RPLC methods. It was further successfully applied to detect 19 free amino acids in biological matrix. 相似文献
8.
《Journal of separation science》2017,40(3):688-696
A method was developed that applies hydrophilic interaction liquid chromatography with tandem mass spectrometry in the multiple reaction monitoring mode to separate and accurately quantify trimethylamine and trimethylamine N‐oxide in a single chromatographic run. This was achieved by converting trimethylamine to ethyl betaine, which is less volatile and hence results in greatly improved quantitation. Ethyl betaine also gives a similar response to trimethylamine N‐oxide using positive‐ion electrospray ionization mass spectrometry. It is readily separated from trimethylamine N‐oxide by hydrophilic liquid chromatography in a 5 min run and with improved peak shape compared to underivatized trimethylamine. Validation of the method yielded a limit of detection (S/N ≥ 3) of 0.5 ng/mL for trimethylamine and 0.25 ng/mL for trimethylamine N‐oxide. Method accuracies of 91.4–105.3% with precisions of 0.4–5.5% were obtained for standard mixtures over the range of 2.5–500 ng/mL. Recoveries measured for the extraction of trimethylamine and trimethylamine N‐oxide spikes into mouse plasma were both >90%. The method, which simultaneously measures trimethylamine and trimethylamine N‐oxide, was successfully applied to mouse plasma samples and could be adapted for use with other biological fluids. 相似文献
9.
Quantification of homoegonol in rat plasma using liquid chromatography–tandem mass spectrometry and its pharmacokinetics application 下载免费PDF全文
Deok‐Gyu Hwang Eun Nam Kim Kyeong Lee Kyung‐Seop Ahn Sei‐Ryang Oh Hye Suk Lee 《Biomedical chromatography : BMC》2014,28(12):1816-1821
Homoegonol is a biologically active neolignan isolated from Styrax species with cytotoxic, antimicrobial, anti‐inflammatory and anti‐asthma activities. For the quantification of homoegonol in rat plasma, a selective and sensitive liquid chromatography–tandem mass spectrometric method was developed and validated for the first time using protein precipitation with methanol as a sample clean‐up procedure. The analytes were separated in an Atlantis dC18 column using a gradient elution of methanol and 0.1% formic acid, and mass‐to‐charge ratios were determined in selective reaction monitoring mode using tandem mass spectrometry with m/z 343.12 > 296.97 for homoegonol and m/z 517.30 > 282.90 for udenafil (internal standard). The standard curve was linear over the concentration ranges of 1 ? 500 ng/mL using a 30 μL rat plasma sample. The coefficient of variation and relative error for intra‐ and inter‐assay at four quality control levels were 3.9–10.0 and ‐3.3–2.7%, respectively. The overall recovery of homoegonol from rat plasma using protein precipitation was 99.7 ± 7.7%. The pharmacokinetics parameters of homoegonol were dose‐independent after both intravenous (1, 2.5 and 5 mg/kg doses) and oral (5, 10 and 20 mg/kg doses) administration in male Sprague–Dawley rats. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
10.
Jaivik V. Shah Daxesh P. Patel Priyanka A. Shah Mallika Sanyal Pranav S. Shrivastav 《Biomedical chromatography : BMC》2016,30(2):208-216
A simple, sensitive and reproducible ultra‐performance liquid chromatography–tandem mass spectrometry method has been developed for the simultaneous determination of atenolol, a β‐adrenergic receptor‐blocker and chlorthalidone, a monosulfonamyl diuretic in human plasma, using atenolol‐d7 and chlorthalidone‐d4 as the internal standards (ISs). Following solid‐phase extraction on Phenomenex Strata‐X cartridges using 100 μL human plasma sample, the analytes and ISs were separated on an Acquity UPLC BEH C18 (50 mm × 2.1 mm, 1.7 µm) column using a mobile phase consisting of 0.1% formic acid–acetonitrile (25:75, v/v). A tandem mass spectrometer equipped with electrospray ionization was used as a detector in the positive ionization mode for both analytes. The linear concentration range was established as 0.50–500 ng/mL for atenolol and 0.25–150 ng/mL for chlorthalidone. Extraction recoveries were within 95–103% and ion suppression/enhancement, expressed as IS‐normalized matrix factors, ranged from 0.95 to 1.06 for both the analytes. Intra‐batch and inter‐batch precision (CV) and accuracy values were 2.37–5.91 and 96.1–103.2%, respectively. Stability of analytes in plasma was evaluated under different conditions, such as bench‐top, freeze–thaw, dry and wet extract and long‐term. The developed method was superior to the existing methods for the simultaneous determination of atenolol and chlorthalidone in human plasma with respect to the sensitivity, chromatographic analysis time and plasma volume for processing. Further, it was successfully applied to support a bioequivalence study of 50 mg atenolol + 12.5 mg chlorthalidone in 28 healthy Indian subjects. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
11.
Praveen Kumar Antoni Rúbies Ramon Companyó Francesc Centrich 《Journal of separation science》2012,35(20):2710-2717
Two methods based on liquid chromatography–tandem mass spectrometry were developed for the determination of ten aminoglycosides (streptomycin, dihydrostreptomycin, spectinomycin, apramycin, paromomycin, kanamycin A, gentamycin C1, gentamycin C2/C2a, gentamycin C1a, and neomycin B) in kidney samples from food‐producing animals and in honey samples. The methods involved extraction with an aqueous solution (for the kidney samples) or sample dissolution in water (for the honey samples), solid‐phase extraction with a weak cation exchange cartridge and injection of the eluate into a liquid chromatography–tandem mass spectrometry system. A zwitterionic hydrophilic interaction chromatography column was used for separation of aminoglycosides and a triple quadrupole mass analyzer was used for detection. The methods were validated according to Decision 2002/657/EC. The limits of quantitation ranged from 2 to 125 μg/kg in honey and 25 to 264 μg/kg in the kidney samples. Interday precision (RSD%) ranged from 6 to 26% in honey and 2 to 21% in kidney. Trueness, expressed as the percentage of error, ranged from 7 to 20% in honey and 1 to 11% in kidney. 相似文献
12.
Plasma lipid analysis by hydrophilic interaction liquid chromatography coupled with electrospray ionization tandem mass spectrometry 下载免费PDF全文
Kazuhiro Sonomura Shinobu Kudoh Taka‐Aki Sato Fumihiko Matsuda 《Journal of separation science》2015,38(12):2033-2037
A novel method for the analysis of endogenous lipids and related compounds was developed employing hydrophilic interaction liquid chromatography with electrospray ionization tandem mass spectrometry. A hydrophilic interaction liquid chromatography with carbamoyl stationary phase achieved clear separation of phosphatidylcholine, lysophosphatidylcholine, sphingomyelin, ceramide, and mono‐hexsosyl ceramide groups with good peak area repeatability (RSD% < 10) and linearity (R2 > 0.99). The established method was applied to human plasma assays and a total of 117 endogenous lipids were successfully detected and reproducibly identified. In addition, we investigated the simultaneous detection of small polar metabolites such as amino and organic acids co‐existing in the same biological samples processed in a single analytical run with lipids. Our results show that hydrophilic interaction liquid chromatography is a useful tool for human plasma lipidome analysis and offers more comprehensive metabolome coverage. 相似文献
13.
Xu Y Huang X Nie X Yang L Yan W Wang Z Wang C Hu Z 《Biomedical chromatography : BMC》2011,25(9):1025-1029
A rapid, selective and sensitive hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry (MS/MS) method was developed to determine 1‐13C‐l ‐methionine in rat serum. Proteins in serum were precipitated using acetonitrile and the supernatant was separated after centrifugation. 1‐13C‐l ‐phenylalnine was used as the internal standard. HILIC–tandem mass spectrometry analysis was performed on a hydrophilic interaction silica column (TSK‐GEL AMIDE‐80) using a linear gradient elution system, acetonitrile−5 mm ammonium acetate containing 0.1% formic acid and multiple reaction monitoring mode for 1‐13C‐l ‐methionine and 1‐13C‐l ‐phenylalnine. The assay was validated with a linear range between 10 and 150 ng mL−1 (r ≥ 0.99) and a lower limit of quantification of 10 ng mL−1, calculated with weighted (1/x2) least squares linear regression. The RSD of intra‐day precision was smaller than 3.6% and the inter‐day RSD less than 6.5%, while the average recovery was 100.48% with an RSD of accuracy within 2.9%, determined from quality control samples. The HILIC‐MS/MS method was fully validated and successfully applied to the in vivo pharmacokinetic study of stable‐isotope 1‐13C‐l ‐methionine in rats. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
14.
Fast quantification of endogenous carbohydrates in plasma using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry 下载免费PDF全文
Bangjie Zhu Feng Liu Xituo Li Yan Wang Xue Gu Jieyu Dai Guiming Wang Chao Yan 《Journal of separation science》2015,38(1):34-41
Endogenous carbohydrates in biosamples are frequently highlighted as the most differential metabolites in many metabolomics studies. A simple, fast, simultaneous quantitative method for 16 endogenous carbohydrates in plasma has been developed using hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry. In order to quantify 16 endogenous carbohydrates in plasma, various conditions, including columns, chromatographic conditions, mass spectrometry conditions, and plasma preparation methods, were investigated. Different conditions in this quantified analysis were performed and optimized. The reproducibility, precision, recovery, matrix effect, and stability of the method were verified. The results indicated that a methanol/acetonitrile (50:50, v/v) mixture could effectively and reproducibly precipitate rat plasma proteins. Cold organic solvents coupled with vortex for 1 min and incubated at –20°C for 20 min were the most optimal conditions for protein precipitation and extraction. The results, according to the linearity, recovery, precision, matrix effect, and stability, showed that the method was satisfactory in the quantification of endogenous carbohydrates in rat plasma. The quantified analysis of endogenous carbohydrates in rat plasma performed excellently in terms of sensitivity, high throughput, and simple sample preparation, which met the requirement of quantification in specific expanded metabolomic studies after the global metabolic profiling research. 相似文献
15.
Noel Kong Rong Yi Sarah Zhao Jasmeet Sandhu Geoffrey Lam Devan Loganathan Barbara Morrissey 《Journal of separation science》2014,37(21):3015-3023
A sensitive hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry method was developed and validated for the simultaneous detection and quantification of etilefrine and oxilofrine in equine blood plasma and urine. The method is highly sensitive and specific with good precision and accuracy. In plasma the limit of detection and limit of quantification are 0.03 and 0.1 ng/mL, respectively, for both analytes. In urine the limit of detection and limit of quantification are 0.3 and 1 ng/mL, respectively, for both analytes. The suitability of the method for doping control analysis in equine species is demonstrated by analyzing postadministration samples collected after a single intravenous administration of 50 mg etilefrine to a standardbred mare. Etilefrine was detected up to 120 h in urine and up to 48 h in plasma. Etilefrine is highly conjugated in equine urine whereas it exists in the free form in equine plasma. Therefore, enzyme hydrolysis prior to sample preparation is recommended for the detection and quantification of etilefrine and oxilofrine in equine urine. 相似文献
16.
《Journal of separation science》2018,41(16):3176-3185
A quick, simple, and reliable method was developed for the simultaneous determination of free and total choline and l‐ carnitine in infant formula employing a novel hydrophilic interaction liquid chromatography with tandem mass spectrometry method. Microwave‐assisted hydrolysis was used to shorten the hydrolysis time to only 15 min. A novel Click XIon zwitterionic stationary phase was chosen because it gave better retention, perfect resolution, and sharper symmetrical peaks compared to traditional columns. The matrix effect under different experimental conditions was evaluated by using the matrix effect factor, which employs stable isotopically labeled internal standards and is more appropriate for evaluating the matrix effect related to endogenous analytes. The accuracy and precision of the method were validated with certified reference materials. The fortified recovery values for choline and l‐ carnitine were between 85.0 and 104% with relevant standard deviations <5.0%. The established method was applied to the analysis of real infant formulas, demonstrating its applicability and feasibility. 相似文献
17.
建立了一种基于亲水作用液相色谱-串联质谱的烟叶中马来酰肼及其糖苷的定量分析方法。方法采用乙腈-甲基叔丁基醚-水(7:10:13,体积比)超声波辅助提取烟叶中的马来酰肼及其糖苷,提取液经离心分相和溶剂置换后进行亲水作用液相色谱-串联质谱分析。马来酰肼及马来酰肼-O-β-D-葡萄糖苷的基质添加标准曲线的线性范围为5~150 mg/kg,相关系数(r2)为0.9971及0.9972,检出限分别为0.5 mg/kg和0.3 mg/kg,定量限分别为1.0 mg/kg和0.8 mg/kg。马来酰肼及马来酰肼-O-β-D-葡萄糖苷在10、40、80 mg/kg 3个加标水平下的回收率为83.1%~112.3%,在40 mg/kg加标水平下的日内重复性分别为2.7%和3.8%,日间重复性分别为8.3%和7.1%。应用该方法分析喷洒马来酰肼28天后烟叶中马来酰肼的分布情况,发现马来酰肼含量减少了80.8%,其中仅有7.6%转化成了马来酰肼糖苷,其他马来酰肼的去向有待进一步研究。 相似文献
18.
Shanhe Wan Xiaoshan Yang Ying Wang Jiajie Zhang Dayong Zheng Zhongqiu Liu 《Biomedical chromatography : BMC》2013,27(11):1532-1539
Topotecan (TPT) is an important anti‐cancer drug that inhibits topoisomerase I. A sensitive and robust liquid chromatography–tandem mass spectrometry (LC‐MS/MS) method that potentially determines TPT in beagle dog plasma is needed for a bioequivalence study of TPT formulations. We developed and validated LC‐MS/MS to evaluate TPT in beagle dog plasma in terms of specificity, linearity, precision, accuracy, stability, extraction recovery and matrix effect. Plasma samples were treated with an OstroTM sorbent plate (a robust and effective tool) to eliminate phospholipids and proteins before analysis. TPT and camptothecin (internal standard) were separated on an Acquity UPLC BEH C18 column (1.7 µm, 2.1 × 50 mm) with 0.1% formic acid and methanol as the mobile phase at a flow rate of 0.25 mL/min. TPT was analyzed using positive ion electrospray ionization in multiple‐reaction monitoring mode. The obtained lower limit of quantitation was 1 ng/mL (signal‐to‐noise ratio > 10). The standard calibration curve for TPT was linear (correlation coefficient > 0.99) at the concentration range of 1–400 ng/mL. The intra‐day and inter‐day precision, accuracy, stability, extraction recovery and matrix effect of TPT were within the acceptable limits. The validated method was successfully applied in a bioequivalence study of TPT in healthy beagle dogs. Copyright © 2013 John Wiley & Sons, Ltd. 相似文献
19.
亲水作用色谱-电喷雾串联质谱法检测原料奶及奶制品中的三聚氰胺 总被引:8,自引:2,他引:8
建立了亲水作用色谱-电喷雾串联质谱测定原料奶及奶制品中三聚氰胺的方法。样品采用1%三氯乙酸水溶液-乙腈(体积比为1∶1)混合溶液提取,混合型阳离子交换反相固相萃取柱(MCX)富集净化,亲水作用色谱柱分离,电喷雾串联四极杆质谱仪进行检测。结果表明,三聚氰胺的质量浓度在0.05~10.0 mg/L范围内具有良好的线性关系。原料奶及奶制品中的三聚氰胺在0.5,2.5和10 mg/kg 3个添加水平下,平均回收率为76.3%~98.7%,相对标准偏差均小于6.8%;定量限(S/N>10)为0.05 mg/kg。 相似文献
20.
Fotini N. Bazoti Evangelos Gikas Anthony Tsarbopoulos 《Biomedical chromatography : BMC》2010,24(5):506-515
Oleuropein (OE) is the cardinal bioactive compound derived from Olea europaea and possesses numerous beneficial properties for human health. However, despite the plethora of analytical methods that have studied the biological fate of olive oil‐derived bioactive compounds, no validated methodology has been published to date for the simultaneous determination of OE, along with all its major metabolites. In this study, a liquid chromatography‐electrospray ionization‐tandem mass spectrometry (LC‐ESI MS/MS) method has been developed and validated for the quantification of OE, simultaneously with its main metabolites hydroxytyrosol, 2‐(3,4‐dihydroxyphenyl)acetic acid, 4‐(2‐hydroxyethyl)‐2‐methoxy‐phenol or homovanillyl alcohol, 2‐(4‐hydroxy‐3‐methoxyphenyl)acetic acid or homovanillic acid, and elenolic acid in rat plasma matrix. Samples were analyzed by LC‐ESI MS/MS prior to and after enzymatic treatment. A solid‐phase extraction step with high mean recovery for all compounds was performed as sample pretreatment. Calibration curves were linear for all bioactive compounds over the range studied, while the method exhibited good accuracy, intra‐ and inter‐day precision. The limit of detection was in the picogram range (per milliliterof plasma) for HT and OE and in the nanogram range (per milliliter of plasma) for the other analytes, and the method was simple and rapid. The developed methodology was successfully applied for the simultaneous quantification of OE and its aforementioned metabolites in rat plasma samples, thus demonstrating its suitability for pharmacokinetics, as well as bioavailability and metabolism studies. Copyright © 2009 John Wiley & Sons, Ltd. 相似文献