1.
The quinolones are derivatives of oxoquinolines and mostly known for their antibacterial and antiviral activities. Many quinolones are chiral compounds having asymmetric centers and important due to their enantioselective biological activities. In order to study the biological activities of quinolone enantiomers, to control the manufacturing of homochiral drugs and to prepare necessary quantities of pure enantiomers for preclinical or clinical trials, respective chiral separation methods are urgently needed. In this context, the present review discusses chromatographic and electrophoretic methods for the enantioseparation of chiral quinolones and provides some useful information on their physical and pharmaceutical properties. The drawbacks of currently used techniques are revealed and ways to overcome them are outlined. Moreover, recommendations for an optimal choice of a separation protocol are given.  相似文献   

2.
Duloxetine (DLX) is a widely used antidepressant drug belonging to the class of selective serotonin and norepinephrine reuptake inhibitors (SNRIs); its efficacy has been demonstrated in the treatment of not only major depressive disorders but also diabetic neuropathic pain, generalized anxiety disorder, fibromyalgia or stress urinary incontinence. It is a chiral substance and is used in therapy in the form of the enantiopure S‐DLX, which is twice as active as R‐DLX. Several methods have been published for the achiral and chiral determination of DLX in pharmaceuticals, biological materials and environmental samples, the majority using liquid chromatography and capillary electrophoresis coupled with different detection techniques (UV detection, fluorescence, mass spectrometry). The aim of the current review is to provide a systematic survey of the analytical techniques used for the determination of DLX from different matrices.  相似文献   

3.
A simple, reliable and sensitive liquid chromatography tandem mass spectrometry (LC‐MS/MS) protocol was developed and validated for quantification of bisoprolol in human plasma. The sample was pretreated with a simple procedure of protein precipitation and an isotope‐labeled d5‐bisoprolol was used as internal standard. The chromatographic separation was performed on a Capcell Pak C18 MG III column (100 mm × 2.0 mm, 5 µm). The protonated ion of the analyte was detected in positive ionization by multiple reaction monitoring mode. The mass transition pairs of m/z 326.3 → 116.3 and m/z 331.3 → 121.3 were used to detect bisoprolol and the internal standard, respectively. Linearity, accuracy, precision, recovery, matrix effect, dilution test and stability were evaluated during method validation over the range of 0.5–100 ng/mL. The validated method was successfully applied to analyze human plasma samples in a bisoprolol bioavailability study. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
建立了直接提取结合液相色谱-电喷雾串联质谱同时测定化妆品中丹诺沙星、恩诺沙星、氟甲喹、恶喹酸、环丙沙星、沙拉沙星、萘啶酸、诺氟沙星、氧氟沙星等25种喹诺酮类药物的方法。样品经酸性乙腈提取和正己烷脱脂净化,采用Poroshell EC-C18色谱柱分离,含0.1%甲酸的乙腈-水溶液为流动相进行梯度洗脱,电喷雾串联质谱正离子模式扫描,多反应监测(MRM)模式检测,外标法定量。实验通过空白基质液配制标准溶液,以降低基质对离子化干扰造成的基质效应,25种喹诺酮类药物在1~200 mg/kg范围内线性关系良好,相关系数(r)在0.999以上。方法的检出限为1.0 mg/kg,在1、5、10 mg/kg 3个加标水平下,水、乳、霜型化妆品中加标回收率为87.4%~105%,相对标准偏差(RSD)为4.54%~19.7%(n=6)。结果表明,该方法简便、快速、准确,适用于化妆品中25种喹诺酮类药物的测定。  相似文献   

5.
A confirmatory method for the simultaneous detection of 29 pharmaceuticals in fish muscle and plasma was developed by using solid‐phase extraction combined with ultra‐high performance liquid chromatography and tandem mass spectrometry. Fish samples were extracted with methanol and enriched using Oasis HLB solid‐phase extraction columns in one step. Twenty‐nine target pharmaceuticals were quantified by the internal standard method and the calibration curves showed good linearity in a wide range with determination coefficients of greater than 0.913. The detection limits of the pharmaceuticals ranged from 0.01 to 2.00 μg/kg (μg/L). The applicability of the method was checked by precision and recovery experiments. The average recoveries of the 29 pharmaceuticals were between 61 and 111%, and all the relative standard deviations were below 25%. Our reported method has been demonstrated to be sensitive, convenient, rapid, and reliable for the simultaneous determination of 29 pharmaceuticals in fish muscle and plasma. Real sample determination showed that 25 and 9 of the 29 compounds were detected in fish muscle and plasma, respectively.  相似文献   

6.
A simple and sensitive liquid chromatography-tandem mass spectrometry method was developed and validated for determining domperidone in human plasma. The analyte and internal standard (IS; mosapride) were isolated from plasma samples by protein precipitation with methanol (containing 0.1% formic acid). The chromatographic separation was performed on an Xterra MS C(18) Column (2.1 x 150 mm, 5.0 microm) with a gradient programme mobile phase consisting of 0.1% formic acid and acetonitrile at a flow rate of 0.30 mL/min. The total run time was 4.0 min. The analyses were carried out by multiple reaction monitoring using the parent-to-daughter combinations m/z 426 --> 175 and m/z 422 --> 198 (IS). The areas of peaks from the analyte and IS were used for quantification of domperidone. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicated that the lower limit of quantification was 0.2 ng/mL, and the assay exhibited a linear range of 0.2-60.0 ng/mL and gave a correlation coefficient (r(2)) of 0.999 or better. Quality control samples (0.4, 0.8, 15 and 50 ng/mL) in six replicates from three different analytical runs demonstrated an intra-assay precision (RSD) 4.43-6.26%, an inter-assay precision 5.25-7.45% and an overall accuracy (relative error) of <6.92%. The method can be applied to pharmacokinetic and bioequivalence studies of domperidone.  相似文献   

7.
We report a simple and highly sensitive method for the simultaneous detection of trace zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate by capillary electrophoresis with inductively coupled plasma mass spectrometry. Zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate were chelated with trans‐1,2‐diaminocyclohexane‐N,N,N′,N′‐tetraacetic acid to form a macromolecule complex. Then, these two compounds were separated by α‐cyclodextrin‐modified capillary electrophoresis within 12 min at a separation voltage of 15 kV and measured by inductively coupled plasma mass spectrometry. The developed method is sensitive with detection limit of 1.9 and 3.0 ng Zn/mL for zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate, respectively. By means of ultrasound‐assisted extraction methods, zinc dimethyldithiocarbamate and zinc ethylenebisdithiocarbamate spiked into cabbage leaves were successfully extracted and determined with a relative standard deviation (= 5) ≤ 6% and a recovery of 95–107%.  相似文献   

8.
Sparfloxacin, a fluoroquinolone antibiotic, is used for the treatment of bacterial infection. A quantification method using mass spectrometry was developed for the determination of sparfloxacin in rat plasma. After simple protein precipitation with acetonitrile, the analytes were chromatographed on a reversed‐phase C18 column and detected by liquid chromatography/tandem mass spectrometry with electrospray ionization. The accuracy and precision of the assay were in accordance with FDA regulations for validation of bioanalytical methods. This method was applied to measure the plasma sparfloxacin concentrations after a single oral administration of sparfloxacin in rats. Copyright © 2010 John Wiley & Sons, Ltd.  相似文献   

9.
A rapid and sensitive liquid chromatography tandem mass spectrometry detection using selected reaction monitoring in positive ionization mode was developed and validated for the quantification of nodakenin in rat plasma and brain. Pareruptorin A was used as internal standard. A single step liquid–liquid extraction was used for plasma and brain sample preparation. The method was validated with respect to selectivity, precision, accuracy, linearity, limit of quantification, recovery, matrix effect and stability. Lower limit of quantification of nodakenin was 2.0 ng/mL in plasma and brain tissue homogenates. Linear calibration curves were obtained over concentration ranges of 2.0–1000 ng/mL in plasma and brain tissue homogenates for nodakenin. Intra‐day and inter‐day precisions (relative standard deviation, RSD) were <15% in both biological media. This assay was successfully applied to plasma and brain pharmacokinetic studies of nodakenin in rats after intravenous administration.  相似文献   

10.
A sensitive and selective high-performance liquid chromatography-positive ion electrospray tandem mass spectrometry method was developed and validated for the quantification of amisulpride in 100 microL of human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase column and analyzed by MS/MS in the multiple reaction monitoring mode using the respective (M + H)(+) ions, m/z 370-242 for amisulpride and m/z 341-112 for the internal standard. The assay exhibited a linear dynamic range with a lower range of 0.1-100 ng/mL and a higher range of 1-500 ng/mL of amisulpride in human plasma. The lower limit of quantification was 0.1 ng/mL with a relative standard deviation of less than 10%. Acceptable precision and accuracy were obtained for both linearity ranges. A run time of 2.0 min for each sample made it possible to analyze more than 275 human plasma samples per day. The validated method has been successfully used to analyze plasma samples for application in pharmacokinetic studies.  相似文献   

11.
A capillary electrophoretic method for the simultaneous determination of sulfamethoxazole and trimethoprim in plasma was developed. Sulfamethoxazole and trimethoprim extracted from human plasma with ethyl acetate were analyzed at 20 kV and 25 degrees C using 15 mm phosphate buffer (pH 6.2) as the electrolyte. The detection was by UV at 220 nm. The run time was 8.0 min and the limit of quantification was 10.00 microg/mL for sulfamethoxazole and 2.00 microg/mL for trimethoprim. The recovery was >99% for both compounds. This method enabled the detection of sulfamethoxazole and trimethoprim in plasma of patients after oral ingestion of their combined formulation. The present simple and rapid method is applicable to drug monitoring in immunocompromised patients who are taking the combined formulation of these compounds for the treatment or prophylaxis of Pneumocystis carinii pneumonia.  相似文献   

12.
Cefepime monitoring in deproteinized human serum and plasma by micellar electrokinetic capillary chromatography and liquid chromatography coupled to mass spectrometry in presence of other drugs is reported. For micellar electrokinetic capillary chromatography, sample preparation comprised dodecylsulfate protein precipitation at pH 4.5 using an increased buffer concentration compared to that of a previous assay and removal of hydrophobic compounds with dichloromethane. This provided robust conditions for cefepime analysis in the presence of sulfamethoxazole and thus enabled its determination in samples of patients that receive cotrimoxazole. The liquid chromatography assay is based upon use of a column with a pentafluorophenyl‐propyl modified and multiendcapped stationary phase and the coupling to electrospray ionization with a single quadrupole detector. The performances of both assays with multilevel internal calibration were assessed with calibration and control samples and both assays were determined to be robust. Cefepime levels monitored by micellar electrokinetic capillary chromatography in samples from patients that were treated with cefepime only and with cefepime and cotrimoxazole were found to compare well with those obtained by liquid chromatography coupled to mass spectrometry. Cefepime drug levels determined by micellar electrokinetic capillary chromatography could thereby be validated.  相似文献   

13.
Oleuropein (OE) is the cardinal bioactive compound derived from Olea europaea and possesses numerous beneficial properties for human health. However, despite the plethora of analytical methods that have studied the biological fate of olive oil‐derived bioactive compounds, no validated methodology has been published to date for the simultaneous determination of OE, along with all its major metabolites. In this study, a liquid chromatography‐electrospray ionization‐tandem mass spectrometry (LC‐ESI MS/MS) method has been developed and validated for the quantification of OE, simultaneously with its main metabolites hydroxytyrosol, 2‐(3,4‐dihydroxyphenyl)acetic acid, 4‐(2‐hydroxyethyl)‐2‐methoxy‐phenol or homovanillyl alcohol, 2‐(4‐hydroxy‐3‐methoxyphenyl)acetic acid or homovanillic acid, and elenolic acid in rat plasma matrix. Samples were analyzed by LC‐ESI MS/MS prior to and after enzymatic treatment. A solid‐phase extraction step with high mean recovery for all compounds was performed as sample pretreatment. Calibration curves were linear for all bioactive compounds over the range studied, while the method exhibited good accuracy, intra‐ and inter‐day precision. The limit of detection was in the picogram range (per milliliterof plasma) for HT and OE and in the nanogram range (per milliliter of plasma) for the other analytes, and the method was simple and rapid. The developed methodology was successfully applied for the simultaneous quantification of OE and its aforementioned metabolites in rat plasma samples, thus demonstrating its suitability for pharmacokinetics, as well as bioavailability and metabolism studies. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

14.
The development of new strategies for the analysis of nucleic acids has gained momentum due to the increased interest in using these biomolecules as drugs or drug targets. The application of new mass spectrometry ion activation techniques and the optimization of separation methods including liquid chromatography, capillary electrophoresis, and ion mobility have allowed more detailed characterization of nucleic acids and oligonucleotide therapeutics including confirmation of sequence, localization of modifications and interaction sites, and structural analysis as well as identification of failed sequences and degradation products. This review will cover tandem mass spectrometry methods as well as the recent developments in liquid chromatography, capillary electrophoresis, and ion mobility coupled to mass spectrometry for the analysis of nucleic acids and oligonucleotides.  相似文献   

15.
环境友好型方法快速检测牛奶中的六种喹诺酮残留   总被引:1,自引:0,他引:1  
本文建立了一种环境友好型、同时分离检测牛奶中六种喹诺酮类药物的高效液相色谱分析法。方法采用反相Chromatorex C18色谱柱,二极管阵列检测器,检测波长为280 nm。实验表明,适当浓度的柠檬酸和硫酸铵溶液作为提取液时可使牛奶中的蛋白质发生缓慢而彻底的变性,释放出与其结合的喹诺酮类药物,从而提高了从牛奶中提取喹诺酮类药物的提取效率。然后通过对提取液进行加热沉淀蛋白质、加入PSA(N-丙基乙二胺修饰的硅胶)净化,即可实现样品的快速前处理。该方法用于牛奶中六种喹诺酮类抗生素残留的测定,回收率均在82.0%~117.8%之间,方法检出限为34.5~85.0 ng·g-1。本文提出的样品前处理方法可靠、快速、环保、易于操作。  相似文献   

16.
A liquid chromatographic/tandem mass spectrometric method is described for the determination of phencyclidine (PCP) in small volumes of rat serum (e.g. 50 microl). Samples were extracted using a mixed-mode strong cation-exchange column and then separated isocratically using a narrow-bore (2.1 mm i.d.) 3 microm Hypersil phenyl column and a mobile phase consisting of an ammonium formate buffer (pH 2.7) with 60% (v/v) methanol. Detection was accomplished using positive ion electrospray ionization in the multiple reaction monitoring mode. Mass spectra were obtained and peaks were observed at an m/z (% abundance) of 244 (100), 159 (25), and 86 (89). Tandem mass spectra were also obtained from the m/z 244 precursor ion with peaks observed at m/z 159 (100), 86 (96), and 91 (11). Optimum serum PCP sensitivity and precision were obtained at a transition of m/z 244 --> 159. Matrix-associated ion suppression did not significantly affect the accuracy (100-112%) or precision (CV < or =8%) of the assay. The lower limit of quantitation was 1 ng ml(-1) in 50 microl of serum. The method was used to study the serum pharmacokinetics of PCP in rats after an intravenous bolus dose of PCP.  相似文献   

17.
A simple, sensitive and rapid liquid chromatographic/electrospray ionization tandem mass spectrometric method was developed and validated for the quantification of lacidipine in human plasma using its structural analogue, amlodipine, as internal standard (IS). The method involves a simple single-step liquid-liquid extraction with tert-butyl methyl ether. The analyte was chromatographed on an Xterra MS C(18) reversed-phase chromatographic column by isocratic elution with 20 mM ammonium acetate buffer-acetonitrile (10:90, v/v; pH 6) and analyzed by mass spectrometry in the multiple reaction monitoring mode. The precursor to product ion transitions of m/z 456.4 --> 354.4 and m/z 409.3 --> 238.3 were used to measure the analyte and the I.S., respectively. The chromatographic run time was 1.5 min and the weighted (1/x(2)) calibration curves were linear over the range 0.1-25 ng ml(-1). Lacidipine was sensitive to temperature in addition to light. The method was validated in terms of accuracy, precision, absolute recovery, freeze-thaw stability, bench-top stability and re-injection reproducibility. The limit of detection and lower limit of quantification in human plasma were 50 and 100 pg ml(-1), respectively. The within- and between-batch accuracy and precision were found to be well within acceptable limits (<15%). The analyte was stable after three freeze-thaw cycles (deviation <15%). The average absolute recoveries of lacidipine and amlodipine (IS) from spiked plasma samples were 51.1 +/- 1.3 and 50.3 +/- 4.9%, respectively. The assay method described here could be applied to study the pharmacokinetics of lacidipine.  相似文献   

18.
A rapid, sensitive and specific method to quantify nevirapine in human plasma using dibenzepine as the internal standard (IS) was developed and validated. The method employed a liquid-liquid extraction. The analyte and the IS were chromatographed on a C(18) analytical column, (150 x 4.6 mm i.d. 4 microm) and analyzed by tandem mass spectrometry in the multiple reaction monitoring mode. The method had a chromatographic run time of 5.0 min and a linear calibration curve over the range 10-5000 ng ml(-1) (r(2) > 0.9970). The between-run precision, based on the relative standard deviation for replicate quality controls was 1.3% (30 ng ml(-1)), 2.8% (300 ng ml(-1)) and 3.6% (3000 ng ml(-1)). The between-run accuracy was 4.0, 7.0 and 6.2% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two nevirapine tablet formulations (Nevirapina from Far-Manguinhos, Brazil, as a test formulation, and Viramune from Boehringer Ingelheim do Brasil Química e Farmacêutica, as a reference formulation) in 25 healthy volunteers of both sexes who received a single 200 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 3 week washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Nevirapina/Viramune was 96.4-104.5% for AUC((0-last)), 91.4-105.1% for AUC((0-infinity)) and 95.3-111.6% for C(max) (AUC = area under the curve; C(max) = peak plasma concentration). Since both 90% CI for AUC((0-last)) and AUC((0-infinity)) and C(max) were included in the 80-125% interval proposed by the US Food and Drug Administration, Nevirapina was considered bioequivalent to Viramune according to both the rate and extent of absorption.  相似文献   

19.
The development and validation of an assay for the determination of paclitaxel in human plasma, human brain tumor tissue, mouse plasma and mouse brain tumor tissue is described. Paclitaxel was extracted from the matrices using liquid-liquid extraction with tert-butyl methyl ether, followed by chromatographic analysis using an alkaline eluent. Positive ionization electrospray tandem mass spectrometry was performed for selective and sensitive detection. The method was validated according to the FDA guidelines on bioanalytical method validation. Validation results indicate that calibration standards in human plasma can be used to quantify paclitaxel in all tested matrices. In human samples, the validated range for paclitaxel was from 0.25-1000 ng ml(-1) using 200 microl plasma aliquots and from 5 to 5000 ng g(-1) using 50 microl tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma). In mice, the ranges were 1-1000 ng ml(-1) and 5-5000 ng g(-1) using 50 microl of mouse plasma and 50 microl of tumor homogenate aliquots (0.2 g tissue ml(-1) control human plasma), respectively. The method can be applied to studies generating only small sample volumes (e.g. mouse plasma and tumor tissue), but also to studies in human plasma requiring a lower limit of quantitation. The assay was applied successfully to several studies with both human and mouse samples.  相似文献   

20.
A rapid and sensitive analytical method based on liquid chromatography coupled to tandem mass spectrometry detection with positive ion electrospray ionization was developed for the determination of febuxostat in human plasma using d7‐febuxostat as the internal standard (IS). A simple protein precipitation was performed using acetonitrile. The analyte and IS were subjected to chromatographic analysis on a Capcell PAK C18 column (4.6 × 100 mm, 5 µm) using acetonitrile–5 mm ammonium acetate–formic acid (85:15:0.015, v/v/v) as the mobile phase at a flow rate of 0.6 mL/min. An Agilent 6460 electrospray tandem mass spectrometer was operated in the multiple reaction monitoring mode. The precursor‐to‐product ion transitions m/z 317 → m/z 261 (febuxsotat) and m/z 324 → m/z (261 + 262) (d7‐febuxostat, IS) were used for quantitation. The results were linear over the studied range (10.0–5000 ng/mL), and the total analysis time for each chromatograph was 3 min. The intra‐ and inter‐day precisions were less than 7.9 and 7.2%, respectively, and the accuracy was within ±4.2%. No evidence of analyte instability in human plasma was observed storage at ?20°C for 31 days. This method was successfully applied in the determination of febuxostat concentrations in plasma samples from healthy Chinese volunteers. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   