1.
Catecholaminesarenowwidelyusedinthetreatmentofbronchialasthma,hypertension,heartfailureassociatedwithorganicheartdiseases,andcardiacsurgery'.Thedeterminationofcatacholaminesinpharmaceuticalpreparationshasappearedespeciallyattractive.Chemiluminescence(CL)hasbeenexploitedinanumberofanalyticalapplicationsowingtoitsgreatsensitivity.SomeCLreactionshavenotfoundmanyapplicationsduetotheinstabilityofoxidationreagentssuchashypochlorite.WeproposedthatunstablereagentsrequiredforCLreactioncanbegenerated…  相似文献   

2.
A high-performance liquid chromatographic method with electrochemical detection was developed for the determination of twelve tea catechins including four major catechins: epicatechin (EC), epigallocatechin (EGC), epicatechin gallate (ECG) and epigallocatechin gallate (EGCG); four of their epimers at the C-2 position, C, GC, CG and GCG; and four methylated catechin derivatives, epigallocatechin-3-O-(3-O-methyl)gallate, gallocatechin-3-O-(3-O-methyl)gallate, epigallocatechin-3-O-(4-O-methyl)gallate and epicatechin-3-O-(3-O-methyl)gallate. These catechins were separated on an ODS C18 reversed-phase column by isocratic elution with 0.1 M NaH2PO4 buffer (pH 2.5)-acetonitrile (87:13) containing 0.1 mM EDTA.2Na. The detection limits (S/N = 3) of these catechins were approximately 10-40 pmol ml-1 at an applied voltage of 600 mV. Extracting these catechins from tea leaf powder with H2O-acetonitrile (1:1) at 30 degrees C for 40 min inhibited the epimerization at C-2 significantly from these epicatechins compared to extraction with hot water at 90 degrees C. This analytical method is sensitive to and appropriate for the simultaneous determination of various biologically active catechins in green tea.  相似文献   

3.
Three methods have been developed for the analysis of Oltipraz in serum. A method suitable for routine use employs spiking with a homologous internal standard, off-line solid-phase extraction, high-performance liquid chromatographic separation, and optical absorbance detection at 450 nm. Method detection limit is about 1 ng/ml. A second method, less susceptible to bias from co-eluting interferences, uses a stable isotope-labeled internal standard, similar extraction and separation, and detection by thermospray mass spectrometry. Method detection limit is about 0.2 ng/ml. A third method was developed which can be used without specially synthesized internal standards. It uses on-line solid-phase extraction, with quantification by comparison with external standards. Method detection limit is about 3 ng/ml. Good agreement was observed between these methods and with similar and different methods run in other laboratories. Calibration curves were linear over the entire range which was investigated, i.e., up to 500 ng/ml. Coefficients of variation were similar for all three methods, being about 5%.  相似文献   

4.
本文研究了阴离子交换树脂D296对待测元素As、Se、Mo、S、Cr的预浓集性能,并与改进的流动注射(FI)(双流路)相结合,建立了一套新型、高效的FI-阴离子交换-ICP-AES分析体系。从而极大地提高了分析的频率和灵敏度,分析速度可达每小时14个样品。As、Se、Mo、S、Cr各元素的检测限分别为13.0 ng/ml、25.2 ng/ml、2.04 ng/ml、6.19 ng/ml、3.64ng/ml。利用此体系检测了标准土壤、头发、牛肝粉等,结果与标准值均很接近。  相似文献   

5.
Toral MI  Richter P  Silva L 《Talanta》1993,40(9):1405-1409
A sensitive derivative spectrophotometric method is described for the determination of microamounts of cobalt based on the integration of liquid-liquid separation and reaction, in dichloroethane, of the analyte with 3-(4-phenyl-2-pyridinyl)-5-phenyl-1,2,4-triazine (PPT) and 2,4,6-trinitro-phenol (picric acid). Cobalt was thus determined in the range 7.2-500 ng/ml. The method has a high selectivity with a detection limit of 2.2 ng/ml. The relative standard deviations were 3.2 and 1.5% for 20 and 100 ng/ml cobalt, respectively. The proposed method was applied to the determination of the analyte in vitamins.  相似文献   

6.
A column-switching high-performance liquid chromatographic method with fluorescence detection was developed for the simultaneous determination of four benzamide-type anti-psychotic drugs: sulpiride, tiapride, sultopride and metoclopramide in human serum. In this method, a TSKgel Super-ODS column was used as an analytical column, and a TSKgel G 2000SW was prepared as a pretreatment column. Under the optimized analytical conditions, four benzamide-type anti-psychotic drugs were eluted within 18 min. The detection limits (S/N = 3) for sulpiride, tiapride, sultopride and metoclopramide are 1 ng/ml, 4 ng/ml, 2 ng/ml and 0.5 ng/ml, respectively. Finally, the method was applied to the determination of sulpiride in human serum samples obtained after a single oral dose of sulpiride.  相似文献   

7.
A sensitive gas chromatographic-electron-capture detection method for the simultaneous determination of the antianginal drug nitroglycerin (GTN) and its dinitrate metabolites (1,2-GDN and 1,3-GDN) was developed. Human plasma samples (1 ml) spiked with 2,6-dinitrotoluene as the internal standard were extracted once with 10 ml of a methylene chloride-pentane mixture (3:7, v/v). Using this solvent system, less contaminants are extracted into the organic phase from plasma, resulting in cleaner chromatograms and prolonged column life. A break point was observed on the standard curves of GTN and GDNs. The two linear regions for the detectable concentrations of GTN are 0.025-0.3 and 0.3-3 ng/ml and for 1,2-GDN and 1,3-GDN they are 0.1-1 and 1-10 ng/ml. The limits of detection by this method for GTN, 1,2-GDN and 1,3-GDN in plasma are 0.025, 0.1 and 0.1 ng/ml, respectively.  相似文献   

8.
A capillary gas-liquid chromatographic method for the determination of 3-methylclonazepam in plasma was developed. This method involved a single extraction by butyl acetate followed by analysis of the organic extract on a CP-Sil 5 glass capillary column with detection by electron capture. The detection limit was about 0.1 ng/ml, and the inter- and intra-assay precision did not exceed 8% for the concentration range 0.1-6.0 ng/ml. Specificity towards some of the possible metabolites in human plasma was demonstrated. This method was used for the measurement of the pharmacokinetic parameters of 3-methylclonazepam in healthy volunteers after a single intravenous administration of 1 mg, and oral administrations of 1 and 4 mg.  相似文献   

9.
Column-switching techniques for high-performance liquid chromatography of two acidic drugs, ibuprofen and mefenamic acid, in human serum with short-wavelength ultraviolet detection are described. The method involved extraction of the analyte from acidified serum followed by the chromatographic analysis using column switching. Three ODS columns were used each with different mobile phase, utilizing the difference of ion-pair formation or of ionization caused by pH change. The method offered high sensitivity and selectivity, with short-wavelength ultraviolet detection at 221 nm for ibuprofen and at 219 nm for mefenamic acid. The detection limits were 0.5 ng/ml (2.4 pmol/ml) for ibuprofen and 0.1 ng/ml (0.4 pmol/ml) for mefenamic acid using 1 ml of serum, both at a signal-to-noise ratio of 3. With some modifications, the principle of the method would be applicable to other acidic compounds in biological fluids.  相似文献   

10.
A reliable routine method is presented for the determination of piperazine down to the sub-ppm level in aqueous solutions and in urine. The method includes a two-phase derivatization procedure with ethyl- or isobutyl chloroformate as the reagent, followed by a capillary gas chromatographic determination using nitrogen- or mass selective detection. The addition of ammonia ensured a quantitative recovery. Detection limits for piperazine in urine were ca. 20 ng/ml using nitrogen-selective and ca. 1 ng/ml with mass-selective detection. The calibration plots were linear in the investigated range, 100-10,000 ng/ml with nitrogen-selective and 30-3000 ng/ml with mass-selective detection. The precision was ca. 6% at a concentration of 300 ng/ml. Acid anhydrides were investigated as alternative reagents in the two-phase derivatization procedure, and heptafluorobutyric acid anhydride in aqueous solutions gave approximately 100% recovery. However, in urine the recoveries of the investigated acid anhydride derivatives were unsatisfactory.  相似文献   

11.
Abstract

A sensitive and rapid assay has been developed for the determination of LY217332, a 3'-imidazolo[4,5-c]pyridinium cephalosporin, in plasma. The method utilizes cyano solid phase column extraction and HPLC with ultraviolet detection. The lower limit of detection is 5 ng/ml plasma and the relative standard deviation for precision and accuracy was 5% or less from 50–500 ng/ml. The method is applicable to the assay of ceftazidime, cephaloridine, cefpirome and BMY-28142 with minor modification of the mobile phase and the detection wavelength.  相似文献   

12.
A continuously operating monitoring method for total mercury at sub-ng/ml level in environmental and biological samples by cold vapour atomic-absorption spectrometry with NaBH4 as a reductant was developed. The mercury vapour generator and absorption cell closed-end by quartz were used in this study. The detection limit (S/N = 3) and relative standard deviation of 12 determinations of 10 ng/ml Hg(II) were 0.11 ng/ml and 1.1%, respectively. The range of standard calibration curve was 0–50 ng/ml Hg, The proposed method was successfully applied to the completely continuous monitoring of total mercury in waste water, sediments and pork liver.  相似文献   

13.
For proof of the presence of chemical warfare agents sarin, soman and VX, a rapid, accurate and sensitive method which allows us to determine their hydrolysis products ethyl methylphosphonic acid, isopropyl methylphosphonic acid and pinacolyl methyl phosphonic acid was explored by using continuous flow frit fast atom bombardment (FAB) LC-MS and LC-MS-MS. After derivatization of analytes with p-bromophenacyl bromide, LC-MS-MS analyses for screening were performed by a flow injection method. The three alkyl methylphosphonic acids (AMPAs) were eluted within 5 min, and the detection limits for the three AMPAs ranged from 1 to 5 ng/ml. For confirmation of the screening results, LC-MS-MS analysis with chromatographic separation was conducted by using a narrow bore column. The three AMPAs were all eluted with excellent separation within 25 min, and the detection limits ranged from 1 to 20 ng/ml. Quantitative measurement was performed by LC-MS in selected ion monitoring (SIM) mode with chromatographic separation. Linear calibration curves were obtained for the three AMPAs and the detection limits ranged from 0.5 to 3 ng/ml. The relative standard deviation for peak area ranged from 3.4 to 6.0% at 50 ng/ml for the three AMPAs.  相似文献   

14.
Currently, the information available on the physiological functions of melatonin in higher plants is rather limited and the role of plant melatonin in human health remains undetermined. Research in this area has been slow due to lack of efficient analytical methods for rapid identification and quantification of the melatonin and related compounds in complex plant matrices. In this communication, we report the development of a rapid, accurate method for extraction, detection and quantification of plant melatonin, serotonin and indole-3-acetic acid (IAA) by Liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and atmospheric pressure photoionization (APPI), respectively. The limit of detection (LOD) of melatonin in the plant extraction was 5 pg/ml and the limit of quantification (LOQ) was 0.02 ng/ml, as well as LOD for serotonin was 100 pg/ml and the LOQ was 5 ng/ml, LOD for IAA was 50 pg/ml and the LOQ was 0.7 ng/ml. There was a linear relationship between melatonin, serotonin, and IAA concentration and peak area over a quantifiable range of 0.02 ng/ml to 0.1 mg/ml, 5 ng/ml to 0.1 mg/ml, and 0.7 ng/ml to 0.1 mg/ml, respectively, in the plant extract.  相似文献   

15.
A sensitive and selective high-performance capillary electrophoresis procedure was developed for the determination of S(+) and R(-) enantiomers of cicletanine in human plasma. The procedure consisted in extraction of the drug with diethyl ether and analysis by micellar electrokinetic capillary chromatography in a fused-silica capillary using gamma-cyclodextrins in the run buffers and ultraviolet detection. The method was linear from 10 to 500 ng/ml and the limit of detection was 10 ng/ml for each enantiomer in plasma samples. The within-run precision of the method, expressed as relative standard deviation, was 10.4 and 9.6% at 25 ng/ml for S(+) and R(-) cicletanine, and 4.2 and 4.6% at 500 ng/ml, respectively. This method has been used to follow the time course of the concentrations of the cicletanine enantiomers in human plasma after a single therapeutic dose of cicletanine given by mouth.  相似文献   

16.
The chiral synthesis of beta-blockers such as (S)-timolol requires a sensitive analytical method for the enantioseparation of its intermediate, 3-tert.-butylamino-1,2-propanediol, in the ng/ml range. The method developed is based on on-line normal-phase LC-MS-MS using a chiral stationary phase and an atmospheric pressure chemical ionization (APCI) interface. The MS detection of 3-tert.-butylamino-1,2-propanediol was first optimized with a pneumatically-assisted electrospray interface (ionspray). The APCI interface was then selected for LC-MS-MS because of the incompatibility of electrospray with n-hexane. The method was validated for both enantiomers in the 25-500 ng/ml concentration range.  相似文献   

17.
Abstract

A selective and sensitive method for the determination of piritramide in human plasma is described. After addition of 50 μl of 2 M ammonia and 20 μl of aqueous promethazine solution (100 ng/10 μ1) as an internal standard, 1 ml of plasma was extracted with 5 ml of toluene (extraction efficiency: 93.9 × 2.6%; mean × S. D.; n = 5). HPLC was performed with a phenyl hypersil NC-04 column, particle size 5 μm, 250 × 4 mm I. D.; mobile phase: 8 parts of acetonitrile and 2 parts of 10 mM potassium phosphate buffer (pH 3. 3). The flow rate was set to 2 ml/min and the column temperature was 22°C. The assay was linear in a concentration range of 3.75 ? 3000 ng/ml (r = 0.999), with a lower limit of detection of 3 ng/ml. The precision was determined using spiked plasma samples (15 ng/ml; 300 ng/ml), with coefficients of variation of 6.1 and 5.9% (intraday; n = 5) and 6.5 and 0.2% (interday; n = 3). In the range of 5.6 ? 1500 ng/ml, the accuracy of the assay was 2.82%. The method was used for the determination of piritramide plasma concentrations in patients receiving intra- or postoperative analgesia.  相似文献   

18.
A flow injection method is proposed for the determination of nanogram amounts of chromium(III) using a pyrogallol chemiluminescence system. It is based on its catalytic effect on the oxidation of pyrogallol with periodate at a neutral medium. The addition of 3-(N-morpholino)propanesulphonic acid to the reaction system increased the chemiluminescence signal for chromium(III). The present method allows the determination of 5-100ng/ml of chromium(III). The relative standard deviation of 2.2% (n = 10) was obtained at 20 ng/ml of chromium(III) and the detection limit (signal-to-noise ratio = 2) was 1 ng/ml with the sampling frequency of 25/hr.  相似文献   

19.
A sensitive and precise method for the determination of nicorandil, a new anti-anginal medication, is reported. The method involves solid-phase extraction of the drug and internal standard using Bond-Elut C18 extraction columns, reversed-phase high-performance liquid chromatography on a Zorbax-Phenyl column and detection with photoconductivity and ultraviolet detection in series. Photoconductivity, performed with the Tracor 965 photoconductivity detector, provided a limit of detection of 2 ng/ml in plasma (between-day coefficient of variation of 15%) but the linear range of response was limited to only about 100 ng/ml. Ultraviolet detection in series with the photoconductivity detector extended the linear range of the analytical system to 1000 ng/ml (coefficient of variation 4.4%). The utility of the method is demonstrated in a dog pharmacokinetic study in which a 5-mg intravenous dose was compared to a 10-mg oral solution dose in six beagle dogs. The oral solution was absorbed rapidly, achieving an average maximum concentration of 857 ng/ml in 11.2 min. The absolute bioavailability of nicorandil in dogs in this study was determined to be 84.2%.  相似文献   

20.
The dioxopiperazine metabolites of quinapril in plasma and urine were extracted with hexane-dichloroethane (1:1) under acidic conditions. Following derivatization with pentafluorobenzyl bromide and purification of the desired reaction products using a column packed with silica gel, the metabolites were analysed separately by capillary column gas chromatography-electron-impact mass spectrometry with selected-ion monitoring. The limits of quantitation for the metabolites were 0.2 ng/ml in plasma and 1 ng/ml in urine. The limits of detection were 0.1 ng/ml in plasma and 0.5 ng/ml in urine, at a single-to-noise ratio of greater than 3 and greater than 5, respectively. The proposed method is applicable to pharmacokinetic studies.  相似文献   