首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
人的基因组研究已成为生命科学前沿领域中最热门的课题之一。DNA序列分析是基因组研究的关键技术.本文对人的基因组分析及其对DNA序列分析的要求进行了论述.对DNA序列分析方法如板凝胶电泳自放射显影法、板凝胶电泳激光荧光法、毛细管电泳激光荧光法、阵列毛细管凝胶电泳激光荧光法。超薄层板在胶电泳激光荧光法作了详细评论.并对正在开发的不用凝胶电泳分离的直接测序新技术和新方法,如质谱法、原子探针法(扫描隧道显微镜、原子力显微镜)、杂交法、流动单分子荧光检测法等进行了评论。  相似文献   

2.
An integrated on-line system is developed for DNA sequencing at the nanoliter scale. The technique involves the use of a nanoreactor for small-volume cycle-sequencing reaction, capillary zone electrophoresis (CZE) for purification of the sequencing fragments, and capillary gel electrophoresis (CGE) for separation of the purified DNA fragments. The nanoreactor and CZE are integrated into one capillary, where a 100-nl dye-labeled terminator cycle-sequencing reaction is carried out followed by CZE to separate excess dye-labeled terminators from the sequencing fragments. On-line electrokinetic injection of the purified DNA fragments into the CGE system is accomplished at a small-volume tee connector by which the CZE capillary is interfaced to the CGE system. The utility of the system is demonstrated in sequencing nanoliter volumes of single-stranded DNA (M13mp18) and double-stranded DNA (pGEM). The use of voltage to drive both CZE and CGE makes it feasible for automation and future adaptation of the whole system to a microchip.  相似文献   

3.
An integrated system for DNA sequencing based on a nanoreactor for cycle-sequencing reaction coupled with on-line capillary zone electrophoresis (CZE) for purification and capillary gel electrophoresis (CGE) for separation is presented. Less than 100 nl of premixed reagent solution, which includes dye-labeled terminator pre-mix, bovine serum albumin and template, was hydrodynamically injected into a fused-silica capillary (75 microm I.D.) inside a laboratory-made microthermocycler for cycle sequencing reaction. In the same capillary, the reaction products were purified by CZE followed by on-line injection of the DNA fragments into another capillary for CGE. Over 540 base pairs (bp) of DNA can be separated and the bases called for single-standed DNA with 0.9% error rate. The total time was about 3.5 h, or a cycle time of 2 h with staggered operation. For double-stranded DNA, a longer reaction time was required and base calling up to 490 bp with 1.2% error rate was achieved. The whole system is readily adaptable to automated multiplex operation for DNA sequencing or polymerase chain reaction analysis.  相似文献   

4.
Capillary electrophoresis (CE) is a new, high-resolution tool for the analysis of DNA restriction fragments and DNA amplified by the polymerase chain reaction (PCR). By combining many of the principles of traditional slab gel methods in a capillary format, it is possible to perform molecular size determinations of human and plant PCR amplification products and DNA restriction fragments. DNA restriction fragments and PCR products were analyzed by dynamic sieving electrophoresis (DSE) and capillary gel electrophoresis (CGE). As part of this study, sample preparation procedures, injection modes, and the use of molecular mass markers were evaluated. Optimum separations were performed using the uPage-3 (3% T, 3% C) CGE columns with UV detection at 260 nm. Membrane dialysis and ultrafiltration/centrifugation proved to be nearly equivalent methods of sample preparation. Reproducibility studies demonstrated that blunt-ended, non-phosphorylated markers (specifically allele generated markers) provide the most accurate calibration for PCR product analysis. This study demonstrates that CE offers a high-speed, high-resolution analytical method for accurately determining molecular size and/or allelic type as compared with traditional methodologies.  相似文献   

5.
毛细管阵列电泳与规模化DNA测序   总被引:5,自引:0,他引:5  
甄志成  姚志建 《色谱》2001,19(4):361-364
 根据 10 0 80份基因组DNA测序的结果 ,讨论了毛细管阵列电泳测序方法的技术特点 ,并对影响测序结果的一些因素进行了分析。在此基础上与平板凝胶电泳方法进行比较 ,显示了毛细管阵列电泳的优点。同时也对大规模测序技术环节之间的协调进行了探讨 。  相似文献   

6.
The aim of the present study was to develop a quantitative-competitive PCR (QC-PCR) method to detect DNA from transgenic herbicide-resistant (roundup ready, RR) soybean and maize. Since no QC-PCR system for the quantification of RR maize had been published at the time of writing, a specific competitor DNA for transgenic event was developed. For the QC-PCR of RR-soybean, a commercially available competitor was employed. These internal standards were calibrated by coamplifying with mixtures containing RR-soybean and maize DNAs. The calibrated QC-PCR systems were applied to certified RR-soybean and maize flour mixtures in order to demonstrate their suitability not only for the quantification of the glyphosate resistance traits in DNA matrices, but also in practically relevant samples. In addition, a special focus of the present work was to compare the detection of QC-PCR products by slab gel and CGE with UV detection. CGE permitted the precise detection of transgenic events also below the equivalence points; while in slab gel electrophoresis, due to the low sensitivity the quantification of genetically modified DNA was allowed only at the equivalence point.  相似文献   

7.
Gao F  Tie C  Zhang XX  Niu Z  He X  Ma Y 《Journal of chromatography. A》2011,1218(20):3037-3041
The separation and sequencing of DNA are the main objectives of the Human Genome Project, and this project has also been very useful for gene analysis and disease diagnosis. Capillary electrophoresis (CE) is one of the most common techniques for the separation and analysis of DNA. DNA separations are usually achieved using capillary gel electrophoresis (CGE) mode, in which polymer gel is packed into the capillary. Compared with a traditional CGE matrix, a hydrophilic polymer matrix, which can be adsorb by the capillary wall has numerous advantages, including stability, reproducibility and ease of automation. Various water-soluble additives, such as linear poly(acrylamide) (PAA) and poly(N,N-dimethylacrylamide) (PDMA), have been employed as media. In this study, different star-shaped PDMA polymers were designed and synthesized to achieve lower polymer solution viscosity. DNA separations with these polymers avoid the disadvantages of high viscosity and long separation time while maintaining high resolution (10 bp between 271 bp and 281 bp). The influences of the polymer concentration and structure on DNA separation were also determined in this study; higher polymer concentration yielded better separation performance, and star-like polymers were superior to linear polymers. This work indicates that modification of the polymer structure is a potential strategy for optimizing DNA separation.  相似文献   

8.
CGE is a well-established separation technique for the analysis of biologically important molecules such as nucleic acids. The inherent high resolving power, rapid analysis times, excellent detection sensitivity, and quantification capabilities makes this method favorable compared to conventional manual polyacrylamide and agarose slab gel electrophoresis techniques. In this paper we introduce a novel single-channel capillary gel electrophoresis system with LED-induced fluorescence detection also utilizing a compact pen-shaped capillary cartridge design for automatic analysis of samples from a 96-well plate. To evaluate the suitability of the system, 1000 genomic DNA(gDNA) samples were analyzed in gel filled capillaries and detected by the microball ended excitation and emission optical fiber based LED-induced fluorescence detection system. Excellent migration time reproducibility of RSD <0.75% was obtained over the course of 1000 runs. The system rapidly distinguished between intact and degraded gDNA samples, therefore provided important information if they could be used for downstream quantitative PCR processing where high-quality intact gDNA was key. We envision that this novel system design will rapidly find new applications in both research and clinical diagnostic laboratories as a highly sensitive and easy to use bio-analytical approach.  相似文献   

9.
Apoptosis is a type of cellular death but also directly regulates tumorigenesis through different gene expression. This phenomenon is often used as end-point in studies of radio- and chemosensitivity of cancer cells. Restriction DNA fragments have been separated quickly, efficiently and successfully by capillary gel electrophoresis (CGE). In this study CGE has been applied to distinguish between the discrete pattern of degraded DNA produced by apoptosis and randomized DNA breaks produced by ionizing radiation. The influence of different variables has been discussed and an example of fast separation by CGE of the apoptotic fragments produced by UV light treatment is shown.  相似文献   

10.
DNA analysis plays a great role in genetic and medical research, and clinical diagnosis of inherited diseases and particular cancers. Development of new methods for high throughput DNA analysis is necessitated with incoming of post human genome era. A new powerful analytical technology, called microchip capillary electrophoresis (MCE), can be integrated with some experimental units and is characterized by high-speed, small sample and reagent requirements and high-throughput. This new technology, which has been applied successfully to the separation of DNA fragments, analysis of polymerase chain reaction (PCR) products, DNA sequencing, and mutation detection, for example, will become an attractive alternative to conventional methods such as slab gel electrophoresis, Southern blotting and Northern blotting for DNA analysis. This review is focused on some basic issues about DNA analysis by MCE, such as fabrication methods for microchips, detection system and separation schemes, and several key applications are summarized.  相似文献   

11.
In the age of genomics and proteomics, high-resolution separation techniques are routinely utilized in an integrated and automated fashion to solve formidable separation problems and provide the means for large-scale analysis of biological samples with excellent resolution. By automating the current manual procedures, capillary gel (CGE) and polymer-solution mediated electrophoresis greatly enhance the productivity of biopolymer analysis while also reducing both analysis time and the human intervention necessary from sample loading to data processing. The advent of this novel and high-performance bioseparation technique has made it possible to sequence the human genome and revealed global changes in the genome and proteome level, bringing about a revolutionary transition in our views of living systems on the molecular basis. CGE and polymer-solution mediated electrophoresis and related microseparation methods (e.g., electrophoresis microchips) are quickly becoming important separation and characterization tools in analytical biochemistry and molecular biology. This review gives an overview of the key application areas of DNA, protein, and complex carbohydrate analysis, and summarizes the latest developments on CGE column technology, including capillary coatings and sieving polymer matrices. Micropreparative aspects and related microseparation techniques are also discussed.  相似文献   

12.
Drug-induced phototoxic skin responses, including photoirritation, photoallergy and photogenotoxicity, are identified as adverse reactions. In this study, we attempted to develop effective analytical tools to predict the photogenotoxic potential of pharmaceutical substances with the use of pBR322 DNA, a plasmid DNA. pBR322 DNA was irradiated with simulated solar light in the presence of photosensitizers, and its structural conversion was assessed by agarose gel electrophoresis (AGE), transmission electron microscopy (TEM) and capillary gel electrophoresis (CGE). The generation of reactive oxygen species (ROS) from photoirradiated photosensitizers was also assessed by spectrophotometrical determination. Concomitant ultraviolet (UV) exposure of pBR322 DNA and photosensitizers resulted in significant oxidative damage to the DNA, as evidenced by AGE, TEM and CGE data, indicating a structural transition from supercoiled form to open circular form. Photosensitizer-induced DNA damage was attenuated by the addition of radical scavengers, especially sodium azide, a typical scavenger of singlet oxygen (1 O2), and enhanced by the addition of deuterium water, an enhancer of the life time of 1 O2. These data, taken together with the results of the ROS assay, suggest that singlet oxygen might act as a major toxic species in quinine-induced photogenotoxicity. The structural analysis of plasmid DNA by CGE after exposure to UVA/B in the presence of photosensitizers could be automated, allowing easy, fast and highly reliable prediction for the photogenotoxic potential of a large number of drug candidates.  相似文献   

13.
利用芯片电泳方法考察瞬间等速电泳-筛分电泳偶联分析的结果,比较了自由溶液和筛分介质中DNA瞬间等速电泳的预浓缩效果.结果显示,相比较于筛分介质条件,自由溶液瞬间等速电泳有利于改善预浓缩和后续筛分电泳分离效果.对此结果的解释是:自由溶液条件下DNA迁移速度的提高可以延长瞬间等速电泳持续时间,有利于提高预浓缩效率.此外,样品压缩区带在自由溶液-筛分介质界面的二次富集也是预浓缩效果得到改善的原因之一.  相似文献   

14.
We described a simple and quick miniaturized sequencing gel system for DNA analysis. Two major modifications were made to the previously reported miniaturized DNA sequencing gel system to achieve high-resolution hydroxyl radical cleavage analysis: including formamide in the miniaturized gel and providing uniform heating during electrophoresis. Our method enables one to reduce the cost for chemicals and to significantly reduce electrophoresis time. Furthermore, minimal gel handling simplifies the entire process. We show that the resolution of DNA fragments obtained by hydroxyl radical cleavage for the miniaturized gel is similar to that of a large conventional sequencing gel.  相似文献   

15.
A voltage‐programming‐based capillary gel electrophoresis method with a laser‐induced fluorescence detector was developed for the fast and highly sensitive detection of DNA molecules related to angiotensin‐converting enzyme insertion/deletion polymorphism, which has been reported to influence predisposition to various diseases such as cardiovascular disease, high blood pressure, myocardial infarction, and Alzheimer's disease. Various voltage programs were investigated for fast detection of specific DNA molecules of angiotensin‐converting enzyme insertion/deletion polymorphism as a function of migration time and separation efficiency to establish the effect of voltage strength to resolution. Finally, the amplified products of the angiotensin‐converting enzyme insertion/deletion polymorphism (190 and 490 bp DNA) were analyzed in 3.2 min without losing resolution under optimum voltage programming conditions, which were at least 75 times faster than conventional slab gel electrophoresis. In addition, the capillary gel electrophoresis method also successfully applied to the analysis of real human blood samples, although no polymorphism genes were detected by slab gel electrophoresis. Consequently, the developed voltage‐programming capillary gel electrophoresis method with laser‐induced fluorescence detection is an effective, rapid analysis technique for highly sensitive detection of disease‐related specific DNA molecules.  相似文献   

16.
Capillary gel electrophoresis (CGE) is a powerful tool for the analysis of oligonucleotides owing to its extraordinary resolving power. However, the only feasible injection mode for CGE, electrokinetic injection, can cause bias of the injected amount and thus reproducibility issues for CGE methods. Although the source of the bias in electrokinetic injection for analysis of small molecules by capillary zone electrophoresis has long been identified, there are very few studies on electrokinetic injection issues for biological molecules analyzed by CGE. In this study, we report three issues related to electrokinetic injection for oligonucleotides. First, the relationship between the injection amount and the sample solution resistance is not always linear for oligonucleotides, as has been observed for small molecules. Second, the injecting water prior to an oligonucleotide sample dramatically improves the reproducibility of both the injected amount and resolution through a ‘stacking‐like’ mechanism. Third, optimizing the gel concentration dramatically increases the amount of oligonucleotide that is injected into the column. Copyright © 2013 John Wiley & Sons, Ltd.  相似文献   

17.
Large scale, high-resolution DNA fragment analysis, such as genotyping, mapping and genetic profiling requires an affordable, fully automated high-throughput gel electrophoresis based separation device that enables rapid, high-performance analysis in a wide molecular weight range. In this article a novel approach is described that greatly enhances the productivity of DNA fragment analysis by automating the current manual procedure and also reducing the separation time and human intervention from sample loading to data analysis. The ultrathin layer, multilane, high-performance agarose gel electrophoresis system employs integrated scanning laser induced fluorescence-avalanche photodiode detection and combines the advantages of conventional slab and capillary gel electrophoresis. The separation platform is fabricated in a way that the sieving matrix can be easily replaced in the separation cassette for each run. Visualization of the DNA fragments is accomplished by ‘in migratio' complexation during the electrophoresis process with ultra-sensitive fluorescent agents, also enabling real-time imaging and data analysis.  相似文献   

18.
It is generally assumed that in order to achieve suitable separations of DNA fragments, capillary gel electrophoresis (CGE)-coated capillaries should be used. In this work, a new method is presented that allows to obtain reproducible CGE separations of DNA fragments using bare fused-silica capillaries without any previous coating step. The proposed method only requires: (i) a capillary washing with 0.1 M hydrochloric acid between injections and (ii) a running buffer composed of Tris-phosphate-ethylenediamine tetraacetic acid (EDTA) and 4.5% of 2-hydroxyethyl cellulose (HEC) as sieving polymer. The use of this new CGE procedure gives highly resolved and reproducible separations of DNA fragments ranging from 50 to 750 bp. The separation of these DNA fragments is accomplished in less than 30 min with efficiencies up to 1.7 x 10(6) plates/m. Reproducibility values of migration times (given as %RSD) for the analyzed DNA fragments are better than 1.0% (n = 4) for the same day, 2.2% (n = 16) for four different days, and 2.3% (n = 16) for four different capillaries. The usefulness of this separation method is demonstrated by detecting genetically modified maize and genetically modified soy after DNA amplification by PCR. This new CGE procedure together with LIF as detector provides sensitive analysis of 0.9% of Bt11 maize, Mon810 maize, and Roundup Ready soy in flours with S/ N up to 542. These results demonstrate the usefulness of this procedure to fulfill the European regulation on detection of genetically modified organisms in foods.  相似文献   

19.
Capillary gel electrophoresis (CGE) has been used for protein separation for more than two decades. Due to the technology advancement, current CGE methods are becoming more and more robust and reliable for protein analysis, and some of the methods have been routinely used for the analysis of protein-based pharmaceuticals and quality controls. In light of this progress, we survey 147 papers related to CGE separations of proteins and present an overview of this technology. We first introduce briefly the early development of CGE. We then review the methodology, in which we specifically describe the matrices, coatings, and detection strategies used in CGE. CGE using microfabricated channels and incorporation of CGE with two-dimensional protein separations are also discussed in this section. We finally present a few representative applications of CGE for separating proteins in real-world samples.  相似文献   

20.
A novel, rapid and efficient separation method is described for the analysis of double stranded (ds) DNA fragments in the form of horizontal ultra-thin-layer agarose gel electrophoresis. This separation technique combines the multilane, high-throughput separation format of agarose slab gel electrophoresis with the excellent performance of capillary electrophoresis. The electrophoretic separation of the fluorophore (Cy5)-labeled dsDNA molecules were imaged in real time by a scanning laser-induced fluorescence/avalanche photodiode detection system. Effects of the gel concentration (Ferguson plot) and separation temperature (Arrhenius plot) on the migration characteristics of the DNA fragments are discussed. An important genotyping application is also shown by characterizing the polymorphic region (2× or 4×48 base pair repeats) of the dopamine D4 receptor gene (D4DR, exon III region) for ten individuals, using PCR technology with Cy5-labeled primers and ultra-thin-layer agarose gel electrophoresis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号