首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The electrospray ion source is an electrolytic flow cell. Electrolytic reactions in the electrospray emitter maintain the production of charged droplets by this ion source that contain an excess of ions of one polarity. These redox reactions necessarily change the composition of the solution that initially enters the emitter. As a result, the ions ultimately observed in the gas phase by electrospray mass spectrometry (ESMS) may be substantially influenced by both the nature and extent of these electrochemical reactions. It is demonstrated in this paper that Ag(+), Cu(2+) and Hg(2+) ions in solution can be electrolytically reduced and deposited as the respective metals on to the surface of the high-voltage contact in the electrospray emitter in negative ion mode electrospray. The deposited metals are shown to be liberated from the surface by switching the electrospray high-voltage polarity to operate in the positive ion mode. The deposited metals are oxidized in positive ion mode, releasing the metal ions back into solution where they are detected in the electrospray mass spectrum. In a semi-quantitative analysis, it was found that up to 50% of the Ag(+) in a 2.5 microM solution was deposited on the high-voltage contact of the emitter as the solution flowed through the emitter. Deposition of Cu(2+) and Hg(2+) was less efficient. These data illustrate that in the analysis of metals by ESMS, one must be aware that both the concentration and form of the metals may be altered by electrochemical processes in the emitter. Hence reduction or oxidation of metals in the electrospray emitter, which may remove ions from solution, or change metal valence, would be expected to impact both quantitative metal determinations and metal speciation attempts using ESMS.  相似文献   

2.
The oxidation behavior of DNA and RNA nucleotides is studied by an on‐line set‐up consisting of an electrochemical thin‐layer cell (EC) directly coupled to electrospray ionization mass spectrometry (ESI‐MS). This set‐up allows the generation of nucleotide oxidation products in the electrochemical cell at increasing potentials. Moreover, the products are determined directly, without isolation or derivatization steps, by electrospray ionization time of flight mass spectrometry (ESI‐ToF/MS). The dependence of the mass spectra on the applied potential is displayed as ‘mass voltammograms’. An advanced set‐up, consisting of the electrochemical cell coupled to electrospray ionization tandem mass spectrometry (EC/ESI‐MS/MS) allows further structure elucidation based on fragmentation experiments. The electrochemical conversion is performed using a boron doped diamond (BDD) working electrode, which is known to generate hydroxyl radicals at high potentials. The capability of the EC‐MS system to generate highly relevant oxidation products which also occur upon oxidative damage in vivo is demonstrated in this study by the formation of well known biomarkers for DNA damage, including 2′‐deoxy‐8‐oxo‐guanosine 5′‐monophosphate.  相似文献   

3.
The interactions between ATP and N-(O,O-diisopropyl) phosphoryl-L-alanine (DIPP-Ala), N-(tert-butoxycarbonyl)-L-alanine (Boc-Ala), or L-alanine (Ala) were investigated by electrospray ionization tandem mass spectrometry (ESI-MS/MS). The non-covalent complexes between ATP and Boc-Ala or DIPP-Ala were observed, while the complex between ATP and Ala was not found in the mass spectra. The affinity of DIPP-Ala for ATP was confirmed to be stronger than that of Boc-Ala by competition experiment. Through molecular modeling calculations, it was found that the non-covalent complexes were stabilized by intermolecular hydrogen bonds, and the affinity sequence for ATP was DIPP-Ala > Boc-Ala > Ala by comparing their binding energy, ?35.407 kcal/mol, ?15.634 kcal/mol, ?6.555 kcal/mol, respectively. The results implied that a phosphoryl group was a very important functional group to provide an interaction site between amino acids and ATP, and that N-phosphoryl amino acids can be used as a good model of protein in the studies of molecular recognition of ATP.  相似文献   

4.
Non-derivatized O-glycosylated amino acids and peptides with multiple glycosylation yield molecular and fragment ions on electrospray ionization. Synthetic substrates were used to demonstrate the fragmentation behaviour of the sugar moiety in positive- and negative ion electrospray mass spectrometry (ESMS) at low and high skimmer potentials. The ion sensitivity is higher compared than when using fast atom bombardment desorption. The potential of ESMS for the sequencing of O-glycans is discussed.  相似文献   

5.
Oxidative stress can disrupt the integrity of genetic material. Due to its importance in the pathogenesis of different kinds of disease, including neurodegenerative disease, cardiovascular disease and cancer, major efforts are put into the elucidation of mechanisms involved. Herein, the combination of electrochemistry/liquid chromatography/mass spectrometry (EC/LC/MS) is presented as convenient, fast and simple method to study nucleic acids oxidation. Guanosine was selected as test compound. 8-Hydroxyguanosine and (guanosine-H)(2) were identified as primary oxidation products. Oxidation was accomplished in an electrochemical thin-layer cell integrated in the flow path of the autosampler of the chromatographic system. The reaction mixture was separated and mass analyzed by LC/MS. The use of LC was found to be particularly beneficial to resolve isobaric oxidation products. Another advantage of the setup used was the ability to decouple the electrochemical cell and the electrospray ionization source from each other eliminating any kind of cell potential interaction. Separation of EC from LC/MS, furthermore, facilitates method optimization. Experimental parameters were optimized for both techniques independently. Highest yields and best detectability of oxidation products were obtained with 10 mM ammonium formate at physiological pH delivered at a flow rate of 2.5-5 μL/min through the electrochemical cell.  相似文献   

6.
电化学电喷雾电离源控制系统的研制   总被引:1,自引:0,他引:1  
凌星  丁传凡 《分析化学》2012,40(10):1627-1631
控制系统是电化学电喷雾电离源的核心部件及研制难点.本研究通过单片机控制数模、模数转换及蓝牙无线通讯模块构建了一套电化学电喷雾电离源(EC/ESI source)的控制系统.利用此系统及一种同轴式探针组成了完整的电化学电喷雾电离源,对9,10-二苯基蒽进行了循环伏安及在线电化学/电喷雾电离质谱(Online EC/ESI-MS)测试.结果表明:此系统具有高达±1 mV的电势控制精度,电流测量精度优于±0.1 μA(增益为0.01 V/μA)或±0.01 μA(增益为0.1 V/μA).本系统具有成本低廉,可在电喷雾高压上安全悬浮,易于操控的特点.  相似文献   

7.
A sensitive, label free electrochemical aptasensor for ATP detection   总被引:1,自引:0,他引:1  
Wang Li  Xiahong Xu  Shouzhuo Yao 《Talanta》2009,78(3):954-249
A sensitive, label free electrochemical aptasensor for small molecular detection has been developed in this work based on gold nanoparticles (AuNPs) amplification. This aptasensor was fabricated as a tertiary hybrid DNA-AuNPs system, which involved the anchored DNA (ADNA) immobilized on gold electrode, reporter DNA (RDNA) tethered with AuNPs and target-responsive DNA (TRDNA) linking ADNA and RDNA. Electrochemical signal is derived from chronocoulometric interrogation of [Ru(NH3)6]3+ (RuHex) that quantitatively binds to surface-confined DNA via electrostatic interaction. Using adenosine triphosphate (ATP) as a model analyte and ATP-binding aptamer as a model molecular reorganization element, the introduction of ATP triggers the structure switching of the TRDNA to form aptamer-ATP complex, which results in the dissociation of the RDNA capped AuNPs (RDNA-AuNPs) and release of abundant RuHex molecules trapped by RDNA-AuNPs. The incorporation of AuNPs in this strategy significantly enhances the sensitivity because of the amplification of electrochemical signal by the RDNA-AuNPs/RuHex system. Under optimized conditions, a wide linear dynamic range of 4 orders of magnitude (1 nM-10 μM) was reached with the minimum detectable concentration at sub-nanomolar level (0.2 nM). Those results demonstrate that our nanoparticles-based amplification strategy is feasible for ATP assay and presents a potential universal method for other small molecular aptasensors.  相似文献   

8.
凌星  丁传凡* 《物理化学学报》2012,28(11):2616-2624
提出一种同轴式电化学电喷雾质谱离子源, 用于电化学与质谱分析在线联用. 离子源结构简单, 造价低廉, 容易制作. 离子源内的电化学反应器工作在两电极模式, 利用自制的悬浮在电喷雾高压上的无线电化学工作站控制. 使用二苯基蒽或三乙胺的乙腈溶液作为分析物, 全面测试了离子源的性能, 包括电势控制精度、电化学转化率、响应时间和抗污能力等. 测试溶液添加浓度约10 mmol·L-1的银盐作为电解质和去极剂, 将溶液电阻降至250 Ω, 提高了在线联用的电势控制精度. 所测二苯基蒽溶液流动时的伏安曲线与常规三电极体系的循环伏安曲线基本一致. 在3.6 μL·min-1的流速下, 离子源的响应时间不超过5 s, 三乙胺的电化学转化率高达77%. 利用此离子源, 研究了蒽的电化学衍生反应, 衍生试剂为十二胺. 蒽作为一种非极性物质, 不能为常规电喷雾质谱检测. 而利用电化学电喷雾质谱离子源, 蒽首先发生电化学氧化反应, 进而与衍生试剂作用生成各种极性物质, 被电喷雾质谱检测. 依据质谱检测到的主要反应产物的相对分子质量与结构提出了衍生反应的机理, 有助于理解蒽的复杂电化学行为.  相似文献   

9.
Combining electrochemical conversion, liquid chromatography and electrospray ionization mass spectrometry (EC/LC/ESI-MS) on-line allows the rapid identification of possible oxidation products of clozapine (CLZ) in the absence and in the presence of glutathione. CLZ is, depending on the applied potential, oxidized to various products in an electrochemical flow-through cell using a porous glassy carbon working electrode. Several hydroxylated and demethylated species are detected on-line using LC/MS. While hydroxy-CLZ is most abundant at a potential of 400 mV, demethylation occurs more readily at higher potentials (at around 700 mV versus Pd/H2 reference). In the presence of glutathione (GSH), various isomeric glutathione adducts and respective products of further oxidation can be identified. The thioadducts are characterized by tandem MS. Mono-GSH and bis-GSH derivatives can be seen in the chromatograms. The results correlate well with the cyclic voltammetric profile of CLZ. The data are relevant from a pharmacological point of view, since similar metabolites (phases I and II) have been reported in the literature. The EC/LC/MS and EC/MS methods should be valuable tools that can be used to anticipate and understand the metabolization patterns of molecules of pharmacological interest and to point out reactive intermediates.  相似文献   

10.
A new supramolecular nanoparticle PEI/SCD was successfully constructed, showing the loading/sustained release abilities towards ATP.  相似文献   

11.
The extent to which electrochemistry on-line with electrospray mass spectrometry can be used to mimic cytochrome P450 catalyzed oxidations has been investigated. Comparisons on the mechanistic level have been made for most reactions in an effort to explain why certain reactions can, and some cannot, be mimicked by electrochemical oxidations. The EC/MS/MS system used successfully mimics in cases where the P450 catalyzed reactions are supposed to proceed via a mechanism initiated by a one-electron oxidation, such as N-dealkylation, S-oxidation, P-oxidation, alcohol oxidation and dehydrogenation. The P450 catalyzed reactions initiated via direct hydrogen atom abstraction, such as O-dealkylation and hydroxylation of unsubstituted aromatic rings, generally had a too high oxidation potential to be electrochemically oxidized below the oxidation potential limit of water, and were not mimicked by the EC/MS/MS system. Even though the EC/MS/MS system is not able to mimic all oxidations performed by cytochrome P450, valuable information can be obtained concerning the sensitivity of the substrate towards oxidation and in which position of the molecule oxidations are likely to take place. For small-scale electrochemical synthesis of metabolites, starting from the drug, the EC/MS/MS system should be very useful for quick optimization of the electrochemical conditions. The simplicity of the system, and the ease and speed with which it can be applied to a large number of compounds, make it a useful tool in drug metabolism research.  相似文献   

12.
A novel method for the manufacturing of microchips for on-chip combinations of electrochemistry (EC) and sheathless electrospray ionisation mass spectrometry (ESI-MS) is described. The technique, which does not require access to clean-room facilities, is based on the incorporation of an array of gold microcoil electrodes into a poly(dimethylsiloxane)(PDMS) microflow channel equipped with an integrated graphite based sheathless ESI emitter. Electrochemical measurements, which were employed to determine the electroactive area of the electrodes and to test the microchips, show that the manufacturing process was reproducible and that the important interelectrode distance in the electrochemical cell could to be adequately controlled. The EC-ESI-MS device was evaluated based on the ESI-MS detection of the oxidation products of dopamine. The results demonstrate that the present on-chip approach enables full potentiostatic control of the electrochemical cell and the attainment of very short transfer times between the electrochemical cell and the electrospray emitter. The transfer times were 0.6 and 1.2 s for flow rates of 1.0 and 0.5 microL min(-1), respectively, while the electrochemical conversion efficiency of the electrochemical cell was found to be 30% at a flow rate of 0.5 microL min(-1). To decouple the electrochemical cell from the ESI-MS high voltage and to increase the user-friendliness, the on-line electrochemistry-ESI-MS experiments were performed using a wireless Bluetooth battery-powered instrument with the chip floating at the potential induced by the ESI high voltage. The described on-chip EC-ESI-MS device can be used for fundamental electrochemical investigations as well as for applications based on the use of electrochemically controlled sample pretreatment, preconcentration and ionisation steps prior to ESI-MS.  相似文献   

13.
Electrochemical properties are inherent to the techniques of electrophoresis and electrospray ionization. Interfacing capillary zone electrophoresis (CZE) with electrospray mass spectrometry (ESMS) can lead to the observation of oxidized species generated as a result of the electrochemical nature of this coupling. Using a nanoelectrospray (nES) interface combined with CZE, controlled chemical oxidation of peptides is demonstrated. The electrolysis of water is used to explain the origin of the chemically oxidized species and this is confirmed using experiments with 18O labeled water. Identification of the oxidized residues was possible using tandem mass spectrometry to sequence the modified peptides. Methionine was found to be the most readily oxidized residue, followed by aromatic amino acids. Surprisingly, oxidation of aliphatic residues (leucine) was also observed. Addition of a reducing agent to the CZE buffer was found to reduce, but not eliminate, the extent of oxidation. The electrochemical generation of protons at the electrosprayer was used to assist in the analysis of monophosphate nucleotides. Nucleotides were separated as anions followed by detection as [M + H]+ ions.  相似文献   

14.
Recent progress in the development of electrospray mass spectrometry (ESMS) as a tool for elemental speciation is reviewed. Reports wherein ESMS is used to qualitatively determine the presence of metal ions (inorganic, organometallic and complexed) and non-metallic inorganic species have grown exponentially over the last decade. In addition to elemental speciation, impact in other areas such as gas-phase chemistry, inorganic–organometallic chemistry and biological mass spectrometry has been prolific. The review is structured to cover each of the areas listed above, and also includes a brief introduction, discussion of the electrospray process, discussion of instrumentation and other relevant application areas. An overview of the types of species/complexes studied is given in each section along with a brief discussion of the application objectives and analytical aspects. Analytical considerations for the development of ESMS as a tool for elemental speciation are also raised, including, application, quantitation, sensitivity, limitations and future directions. The impact of speciation strategies involving stand-alone ESMS, ESMS coupled with on-line separation techniques and the inclusion of ESMS in dual (multiple) technique strategies are presented. High backgrounds due to chemical noise and signal suppression (matrix effects) appear to be two important factors limiting sensitive detection of most analytes. The use of sample pre-treatment, pre-concentration or separation techniques is necessary to alleviate these problems. Although ESMS currently suffers from a number of limitations, continued instrumentation and methods development will improve its capability and diversify the impact of ESMS as a tool for elemental speciation.  相似文献   

15.
When zotepine, an antipsychotic drug, was electrochemically oxidized using electrospray ionization mass spectrometry (ESI-MS) coupled with a microflow electrolytic cell, [M + 16 + H]+ (m/z 348), [M-H]+ (m/z 330) and [M-14 + H]+ (m/z 318) were observed as electrochemical oxidation product ions (M represents the zotepine molecule). Although a major fragment ion that was derived from the dimethyl aminoethyl moiety was observed only at m/z 72 in the collision-induced dissociation (CID) spectrum of zotepine, new fragments such as m/z 315 and 286 ions could be generated in the CID spectrum by combining electrochemical oxidation and CID. Since these fragments were relatively specific with high ion strength, it was thought that they would be useful for developing a sensitive LC-MS/MS assay. The S-oxide and N-demethylated products were detected by electrolysis assuring that a portion of P450 metabolites of zotepine could be mimicked by the electrochemistry/electrospray ionization mass spectrometry (EC/ESI-MS) system.  相似文献   

16.
We report here the development of a corona discharge (CD) initiated electrochemical (EC) electrospray ionization (ESI) technique using a standard electrospray ion source. This is a new ionization technique distinct from ESI, electrochemistry inherent to ESI, APCI, and techniques using hydroxyl radicals produced under atmospheric pressure conditions. By maximizing the observable CD at the tip of a stainless steel ESI capillary, efficient electrochemical oxidation of electrochemically active compounds is observed. For electrochemical oxidation to be observed, the ionization potential of the analyte must be lower than Fe. Ferrocene labeled compounds were chosen as the electrochemically active moiety. The electrochemical cell in the ESI source was robust, and generated ions with selectivity according to the ionization potential of the analytes and up to zeptomolar sensitivity. Our results indicate that CD initiated electrochemical ionization has the potential to become a powerful technique to increase the dynamic range, sensitivity, and selectivity of ESI experiments.  相似文献   

17.
The utility of thermospray mass spectrometry (TSMS), fast-atom bombardment mass spectrometry (FABMS), and electrospray mass spectrometry (ESMS) for the analysis of Fumonisin B1 is investigated. In addition, the analysis of two different standards of Fumonisin B1 as well as an inoculated corn culture extract that contained Fumonisin B1 is reported. The results of these efforts show that ESMS, as well as FABMS and a combination of FAB and tandem mass spectrometry (FABMS/MS), provide useful data for the characterization of Fumonisin B1. The detection limit was 50 pg for Fumonisin B1 when analyzed by full scan FABMS, and 5 pg when analyzed by single-reaction monitoring FABMS/MS.  相似文献   

18.
An on-line electrochemistry/electrospray mass spectrometry system (EC/MS) is described that allows fast analysis of the oxidation products of peptides. A range of peptides was oxidized in an electrochemical cell by application of a potential ramp from 0 to 1.5 V during passage of the sample. Electrochemical oxidation of peptides was found to occur readily when tyrosine was present. Tyrosine was found to be oxidized between 0.5 and 1.0 V to various oxidation products, including peptide fragments formed by hydrolysis at the C-terminal side of tyrosine. The results confirm earlier knowledge on the mechanisms and reaction products of chemical and electrochemical peptide oxidation. Methionine residues are also readily oxidized, but do not induce peptide cleavage. At potentials higher than about 1.1 V, additional oxidation products were observed in some peptides, including loss of 28 Da from the C-terminus and dimerization. The tyrosine-specific cleavage reaction suggests a possible use of the EC/MS system as an on-line protein digestion and peptide mapping system. In addition, the system can be used to distinguish phosphorylated from unphosphorylated tyrosine residues. Four forms of the ZAP-70 peptide ALGADDSYYTAR with both, either or neither tyrosine phosphorylated were subjected to a 0-1.5 V potential ramp. Oxidation of, and cleavage adjacent to, tyrosine was observed exclusively at unphosphorylated tyrosine residues.  相似文献   

19.
利用锥形量热仪(CONE)在35kW/m2热辐照条件下,并结合极限氧指数(LOI)和UL-94垂直燃烧测试方法对聚丙烯(PP)/乙烯-醋酸乙烯酯共聚物(EVA)/有机蒙脱土(OMMT)纳米复合材料和加入无卤复配阻燃剂制备的PP/EVA/OMMT/氢氧化铝(ATH)/三氧化二锑(AO)纳米复合阻燃材料的热释放速率、烟释放及材料在燃烧时的质量损失行为进行了研究。结果表明,添加5%(质量分数)OMMT可以提高PP/EVA复合材料的阻燃性能,燃烧时的热释放速率、质量损失率以及烟释放量减少,且OMMT与无卤复配阻燃剂之间可产生阻燃协同作用,使纳米复合阻燃材料的阻燃性能、热稳定性和抑烟性进一步增强。  相似文献   

20.
Faris A  Spence DM 《The Analyst》2008,133(5):678-682
It is known that adenosine triphosphate (ATP) is released from red blood cells (RBCs) due to various forms of stimulation such as deformation, pharmacological stimuli, and hypoxia. To date, these various stimuli have been investigated individually. Here, we have combined a microflow system capable of initiating deformation-induced release of ATP from the RBCs at various levels of hypoxia as measured by percent oxygen saturation in the RBC sample. When values of ATP released from deformation and hypoxia are compared to values of ATP release due to hypoxia alone, the relationship between the two stimuli can be deduced. Measurement of RBC-derived ATP with the well-known chemiluminescence assay employing luciferin/luciferase indicates that RBCs deoxygenated for 4 min released 1.84 +/- 0.075 microM ATP. The largest decrease in oxygen saturation was found to be between 0 s (66.3% O(2) saturation) and 15 s (22.3% O(2) saturation). RBCs deoxygenated to a 22.3% O(2) saturation released 0.374 +/- 0.011 microM ATP when pumped through the microflow system. This value is an increase from 0.281 +/- 0.007 microM ATP in the presence of flow alone. The ATP release after exposure to hypoxia at 22.3% O(2) saturation was 0.381 +/- 0.014 microM ATP, a value statistically equivalent to that of hypoxia and flow combined. These data suggest that, at an oxygen saturation point of around 25.0% or above, deformation contributes to ATP release from the RBC; however, beyond this saturation point, the ATP release is largely due to hypoxia.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号