首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
The monitoring of total sulfur content and speciation of individual sulfur-containing compounds in middle distillates is required for efficient catalyst selection and for a better understanding of the kinetics of the reactions involved in hydrotreament processes. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GCxGC) hyphenated to sulfur chemiluminescence detection (SCD) has recently evolved as a powerful tool for improving characterization and identification of sulfur compounds. The aim of this paper is to compare quantitatively GCxGC-SCD and various other methods commonly employed in the petroleum industry, such as X-ray fluorescence, conventional GC-SCD, and high-resolution mass spectrometry, for total sulfur content determination and speciation analysis. Different samples of middle distillates have been analyzed to demonstrate the high potential and important advantages of GCxGC-SCD for innovative and quantitative analysis of sulfur-containing compounds. More accurate and detailed results for benzothiophenes and dibenzothiophenes are presented, showing that GCxGC-SCD should become, in the future, an essential tool for sulfur speciation analysis.  相似文献   

2.
We determine the elemental compositions of aromatic nitrogen model compounds as well as a petroleum sample by atmospheric pressure photoionization (APPI) and electrospray Ionization (ESI) with a 9.4 Tesla Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. From the double-bond equivalents calculated for the nitrogen-containing ions from a petroleum sample, we can infer the aromatic core structure (pyridinic versus pyrrolic nitrogen heterocycle) based on the presence of M(+.) (odd-electron) versus [M+H](+) (even-electron) ions. Specifically, nitrogen speciation can be determined from either a single positive-ion APPI spectrum or two ESI (positive- and negative-ion) spectra. APPI operates at comparatively higher temperature than ESI and also produces radical cations that may fragment before detection. However, APPI fragmentation of aromatics can be eliminated by judicious choice of instrumental parameters.  相似文献   

3.
Products of the reaction of C(60) with H(2) gas have been monitored by high-resolution atmospheric pressure photoionization Fourier transform ion cyclotron resonance mass spectrometry (APPI FT-ICR MS), X-ray diffraction, and IR spectroscopy as a function of hydrogenation period. Samples were synthesized at 673 K and 120 bar hydrogen pressure for hydrogenation periods between 300 and 5000 min, resulting in the formation of hydrofullerene mixtures with hydrogen content ranging from 1.6 to 5.3 wt %. Highly reduced C(60)H(x) (x > 36-40) and products of their fragmentation were identified in these samples by APPI FT-ICR MS. A sharp change in structure was observed for samples with at least 5.0 wt % of hydrogen. Low-mass (300-500 Da) hydrogenation products not observed by prior field desorption (FD) FT-ICR MS were detected by APPI FT-ICR MS and their elemental compositions obtained for the first time. Synthetic and analytical fragmentation pathways are discussed.  相似文献   

4.
The continuous development in analytical instrumentation has brought the newly developed Orbitrap‐based gas chromatography / mass spectrometry (GC/MS) instrument into the forefront for the analysis of complex mixtures such as crude oil. Traditional instrumentation usually requires a choice to be made between mass resolving power or an efficient chromatographic separation, which ideally enables the distinction of structural isomers that is not possible by mass spectrometry alone. Now, these features can be combined, thus enabling a deeper understanding of the constituents of volatile samples on a molecular level. Although electron ionization is the most popular ionization method employed in GC/MS analysis, the need for softer ionization methods has led to the utilization of atmospheric pressure ionization sources. The last arrival to this family is the atmospheric pressure photoionization (APPI), which was originally developed for liquid chromatography / mass spectrometry (LC/MS). With a newly developed commercial GC‐APPI interface, it is possible to extend the characterization of unknown compounds. Here, first results about the capabilities of the GC/MS instrument under high or low energy EI or APPI are reported on a volatile gas condensate. The use of different ionization energies helps matching the low abundant molecular ions to the structurally important fragment ions. A broad range of compounds from polar to medium polar were successfully detected and complementary information regarding the analyte was obtained.  相似文献   

5.
Atmospheric pressure photoionization (APPI) is a novel method of ionization in liquid chromatography/mass spectrometry (LC/MS). It was originally developed in order to broaden the range of LC/MS ionizable compounds towards less polar compounds that cannot be analyzed by electrospray (ESI) and atmospheric pressure chemical ionization (APCI). Studies done thus far have shown that non-polar compounds that earlier were not ionizable in LC/MS can indeed be ionized by the use of APPI. However, the best ionization efficiency for low polarity samples has been achieved with low proton affinity (PA) solvents that are not suitable in reversed-phase LC (RP-LC). Here it is demonstrated that the signals for analytes with low proton affinities in acetonitrile can be increased 100-fold by using anisole as the dopant for APPI, which takes the sensitivity to the same level achieved in the analysis of high PA analytes.  相似文献   

6.
Positive-ion atmospheric pressure chemical ionization (APCI) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) analyses of petroleum sample were performed with higher sensitivity by switching the solvent composition from toluene and methanol or acetonitrile to a one-component system consisting only of toluene. In solvent blends, molecular ions were more abundant than were protonated ions with increasing percentages of toluene. In 100% toluene, the double-bond equivalence (DBE) distributions of molecular ions obtained by APCI MS for each compound class were very similar to those obtained in dopant assisted atmospheric pressure photo ionization (APPI) MS analyses. Therefore, it was concluded that charge-transfer reaction, which is important in toluene-doped APPI processes, also plays a major role in positive-ion APCI. In the DBE distributions of S1, S2, and SO heteroatom classes, a larger enhancement in the relative abundance of molecular ions at fairly specific DBE values was observed as the solvent was progressively switched to toluene. This enhanced abundance of molecular ions was likely dependent on molecular structure.  相似文献   

7.
Liquid chromatography/atmospheric pressure photoionization tandem mass spectrometry (LC/APPI-MS/MS) was investigated as an instrumental method for the analysis of the halogenated norbornene flame retardants, Mirex, Dechloranes 602, 603, 604, and Dechlorane Plus (DP). The LC separation was optimized by screening a variety of stationary and mobile phases, resulting in a short LC separation time of 5 min. Different atmospheric pressure ionization approaches were examined including electrospray ionization, atmospheric pressure chemical ionization, and APPI, each with and without post-column addition. APPI without post-column addition was chosen for providing the best ionization response. The optimized LC/APPI-MS/MS approach resulted in instrument detection limits ranging between 25 and 50 pg. Good linearity was also achieved (up to 25.0 ng/μL; R >0.999). The method was applied to extracts of environmental samples including surface water, fish and sediments for screening purposes, and the results agreed well with those obtained by gas chromatography/mass spectrometry.  相似文献   

8.
This article provides a review of the use of modern mass spectrometry (MS) for quantitative and qualitative measurements of organic phosphorus compounds in nature. Included is a brief discussion of recent developments in large molecule mass spectrometry, focusing on time-of-flight (TOF) and ion cyclotron resonance (ICR) mass analysis techniques, as well as electrospray (ESI) and inductively coupled plasma (ICP) ionization. The use of ICP with high-resolution mass spectrometry for quantitative measurements of total phosphorus and as a detector coupled to HPLC and CE for defining organic phosphorus speciation is demonstrated using results from a study of phosphorus cycling in a treatment wetland. Qualitative identifications of individual phosphorus compounds by ultrahigh resolution Fourier-transform ion cyclotron resonance mass spectrometry (FT-ICR MS) is demonstrated using dissolved organic phosphorus isolated from this same wetland.  相似文献   

9.
In this work the higher peak capacity and resolution of comprehensive two-dimensional gas chromatography (GCxGC) has been successfully applied, for the first time, to tentatively identify several polar organic compounds of organic extracts of aqueous phases resulting from microwave demulsification process of water-in-crude oil emulsions. Results have shown that higher temperatures and longer exposure time to microwave irradiation produced water phases with a wider variety of polar organic compounds. The microwave process showed to be suitable for the extraction of several polar compounds classes of petroleum. The proposed microwave extraction method and GCxGC identification of polar compounds of petroleum samples are of practical interest for the petrochemical industry due to corrosion and related problems associated with these polar compounds in refinery equipments. The GCxGC/time-of-flight MS technique shows to be very important in the total separation of different classes of compounds and allows the identification of many compounds in these classes.  相似文献   

10.
在四氟硼酸银的催化作用下,以碘甲烷对直馏柴油进行甲基衍生化反应,使其中的有机硫化物转变成极性较强的锍盐,再用电喷雾-傅立叶变换离子回旋共振质谱仪进行检测。结合气相色谱-脉冲火焰光度检测器(GC-PFPD)分析,研究不同类型的硫化物甲基衍生化反应的选择性和转化率。结果表明:柴油中硫化物在室温条件下容易与碘甲烷发生甲基化反应,大部分硫化物转化为锍盐,总转化率超过80%,苯并噻吩类比二苯并噻吩类更易发生甲基衍生化反应,转化率也相应较高。烷基二苯并噻吩不同取代位异构体间反应选择性存在较大差异,高分辨质谱分析结果表明,直馏柴油中存在环状硫醚类化合物。  相似文献   

11.
Capillary electrophoresis/mass spectrometry (CE/MS) is predominantly carried out using electrospray ionization (ESI). Recently, atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) have become available for CE/MS. With the VUV lamp turned off, the APPI source may also be used for CE/MS by thermospray ionization (TSI). In the present study the suitability of ESI, APCI, APPI and TSI for drug impurity profiling by CE/MS in the positive ion mode is evaluated. The drugs carbachol, lidocaine and proguanil and their potential impurities were used as test compounds, representing different molecular polarities. A background electrolyte of 100 mM acetic acid (pH 4.5) provided baseline separation of nearly all impurities from the respective drugs. APPI yielded both even‐ and odd‐electron ions, whereas the other ionization techniques produced even‐electron ions only. In‐source fragmentation was more pronounced with APCI and APPI than with ESI and TSI, which was most obvious for proguanil and its impurities. In general, ESI and TSI appeared the most efficient ionization techniques for impurities that are charged in solution achieving detection limits of 100 ng/mL (full‐scan mode). APPI and APCI showed a lower efficiency, but allowed ionization of low and high polarity analytes, although quaternary ammonium compounds (e.g. carbachol) could not be detected. Largely neutral compounds, such as the lidocaine impurity 2,6‐dimethylaniline, could not be detected by TSI, and yielded similar detection limits (500 ng/mL) for ESI, APPI and APCI. In many cases, impurity detection at the 0.1% (w/w) level was possible when 1 mg/mL of parent drug was injected with at least one of the CE/MS systems. Overall, the tested CE/MS systems provide complementary information as illustrated by the detection and identification of an unknown impurity in carbachol. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

12.
Ivano Marchi 《Talanta》2009,78(1):1-610
This review presents the state-of-the-art techniques that couple liquid chromatography (LC) and mass spectrometry (MS) via atmospheric pressure photoionization (APPI). The different ionization mechanisms are discussed as well as the influence of the mobile phase composition, the nature of the dopant, etc. A comparison with other ionization sources, such as electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI), is reported, and the combination of APPI with these sources is also discussed. Several applications, covering the time period of 2005-2008, for the analysis of drugs, lipids, natural compounds, pesticides, synthetic organics, petroleum derivatives, and other substances are presented.  相似文献   

13.
To further clarify the role of dopant solvent in proton transfer in atmospheric pressure photoionization (APPI), we employ ultrahigh-resolution FT-ICR mass analysis to identify M(+*), [M + H](+), [M - H](-), and [M + D](+) species in toluene or perdeuterotoluene for an equimolar mixture of five pyrrolic and pyridinic nitrogen heterocyclic model compounds, as well as for a complex organic mixture (Canadian Athabasca bitumen middle distillate). In the petroleum sample, the protons in the [M + H](+) species originate primarily from other components of the mixture itself, rather than from the toluene dopant. In contrast to electrospray ionization, in which basic (e.g., pyridinic) species protonate to form [M + H](+) positive ions and acidic (e.g., pyrrolic) species deprotonate to form [M - H](-) negative ions, APPI generates ions from both basic and acidic species in a single positive-ion mass spectrum. Ultrahigh-resolution mass analysis (in this work, m/Deltam(50%) = 500,000, in which Deltam(50%) is the mass spectral peak full width at half-maximum peak height) is needed to distinguish various close mass doublets: (13)C versus (12)CH (4.5 mDa), (13)CH versus (12)CD (2.9 mDa), and H(2) versus D (1.5 mDa).  相似文献   

14.
This study assessed the pyrolysis liquids obtained by slow pyrolysis of industrial hemp leaves, hurds, and roots. The liquids recovered between a pyrolysis temperature of 275–350 °C, at two condensation temperatures 130 °C and 70 °C, were analyzed. Aqueous and bio-oil pyrolysis liquids were produced and analyzed by proton nuclear magnetic resonance (NMR), gas chromatography–mass spectrometry (GC-MS), and atmospheric pressure photoionization Fourier transform ion cyclotron resonance mass spectrometry (APPI FT-ICR MS). NMR revealed quantitative concentrations of the most abundant compounds in the aqueous fractions and compound groups in the oily fractions. In the aqueous fractions, the concentration range of acetic acid was 50–241 gL−1, methanol 2–30 gL−1, propanoic acid 5–20 gL−1, and 1-hydroxybutan-2-one 2 gL−1. GC-MS was used to compare the compositions of the volatile compounds and APPI FT-ICR MS was utilized to determine the most abundant higher molecular weight compounds. The different obtained pyrolysis liquids (aqueous and oily) had various volatile and nonvolatile compounds such as acetic acid, 2,6-dimethoxyphenol, 2-methoxyphenol, and cannabidiol. This study provides a detailed understanding of the chemical composition of pyrolysis liquids from different parts of the industrial hemp plant and assesses their possible economic potential.  相似文献   

15.
原油中芳香硫化合物形态分布的研究   总被引:1,自引:0,他引:1  
曾小岚  刘君  刘建华  杨永坛 《分析化学》2006,34(11):1546-1550
建立了原油中多环芳香硫化合物形态分布的研究方法。采用氯化钯/硅胶配位交换色谱分离原油中的芳香硫化合物,并用气相色谱/质谱分析、气相色谱-硫化学发光检测法结合色谱保留指数,鉴定出原油中的100多个多环芳香硫化物,包括含烷基取代基的苯并噻吩和二苯并噻吩类硫化物。定量分析表明,二苯并噻吩类化合物的含量占芳香硫化合物总量的91%左右。该方法可用于不同来源的原油中芳香硫化合物的形态分布研究。  相似文献   

16.
Sulfur-containing compounds in diesel have been speciated by comprehensive two-dimensional gas chromatography (GCxGC) with a sulfur chemiluminescence detector (SCD). The advantages of GCxGC technique are higher resolution and greater sensitivity. GCxGC-SCD can achieve the class separation of sulfur-containing compounds with an appropriate separation column combination. The major classes of sulfur-containing compounds in diesel are benzothiophenes and dibenzothiophenes. Relative concentration of each class as well as each carbon number family can be quantitated by the summation of the integrated areas corresponding to the individual group(s) in the GCxGC space. In practical applications, GCxGC-SCD can be used to characterize different diesels and to reflect desulfurization process efficiency. In this study, GCxGC-SCD has demonstrated its value in speciation of sulfur-containing compounds classes, which is difficult to accomplish by any other single technique.  相似文献   

17.
A method is described for automating the regulation of cold jet flow of a comprehensive two-dimensional gas chromatograph (GCxGC) configured with flame ionization detection. This new capability enables the routine automated separation, identification, and quantitation of hydrocarbon types in petroleum fractions extending into the vacuum gas oil (VGO) range (IBP-540 degrees C). Chromatographic data acquisition software is programmed to precisely change the rate of flow from the cold jet of a nitrogen cooled loop modulator of a GCxGC instrument during sample analysis. This provides for the proper modulation of sample compounds across a wider boiling range. The boiling point distribution of the GCxGC separation is shown to be consistent with high temperature simulated distillation results indicating recovery of higher boiling semi-volatile VGO sample components. GCxGC configured with time-of-flight mass spectrometry is used to determine the molecular identity of individual sample components and boundaries of different molecular types.  相似文献   

18.
This paper examined the bond dissociation behavior and aromatic ring architecture of basic nitrogen compounds in Sudan heavy petroleum fraction. Both broadband and quadrupole isolation modes positive-ion electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) coupled with collision induced dissociation (CID) techniques were used to characterize a low sulfur crude oil derived vacuum residuum (VR). The appropriate CID operating condition was selected by comparing the molecular weight distributions of the basic nitrogen compounds under various CID operating conditions. Both oddand even-electron fragment ions were observed from the mass spectrum, indicating that the heterolytic and homolytic bond cleavages occurred simultaneously during the CID process. The odd-electron fragment ions were predominant in each class species, indicating preferential heterolytic bond cleavages. At the optimal CID condition, the alkyl groups decomposed deeply and just left the aromatic cores of the nitrogen compounds. No significant variation in double bond equivalent (DBE) value was observed between the fragment and parent ions, revealing that the domination of single core structure.  相似文献   

19.
Gas chromatography/mass spectrometry (GC/MS) is applied to the analysis of volatile and thermally stable compounds, while liquid chromatography/atmospheric pressure chemical ionization mass spectrometry (LC/APCI‐MS) and liquid chromatography/electrospray ionization mass spectrometry (LC/ESI‐MS) are preferred for the analysis of compounds with solution acid‐base chemistry. Because organic explosives are compounds with low polarity and some of them are thermally labile, they have not been very well analyzed by GC/MS, LC/APCI‐MS and LC/ESI‐MS. Herein, we demonstrate liquid chromatography/negative ion atmospheric pressure photoionization mass spectrometry (LC/NI‐APPI‐MS) as a novel and highly sensitive method for their analysis. Using LC/NI‐APPI‐MS, limits of quantification (LOQs) of nitroaromatics and nitramines down to the middle pg range have been achieved in full MS scan mode, which are approximately one order to two orders magnitude lower than those previously reported using GC/MS or LC/APCI‐MS. The calibration dynamic ranges achieved by LC/NI‐APPI‐MS are also wider than those using GC/MS and LC/APCI‐MS. The reproducibility of LC/NI‐APPI‐MS is also very reliable, with the intraday and interday variabilities by coefficient of variation (CV) of 0.2–3.4% and 0.6–1.9% for 2,4,6‐trinitrotoluene (2,4,6‐TNT). Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

20.
The applicability of three different ionization techniques: atmospheric pressure photoionization (APPI), atmospheric pressure chemical ionization (APCI) and electrospray ionization (ESI) was tested for the liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis of five target pharmaceuticals (cyclophosphamide, methotrexate, bezafibrate, enalapril and orlistat) in wastewater samples. Performance was compared both by flow injection analysis (FIA) and on-column analysis in deionized water and wastewater samples. A column switching technique for the on-line extraction and analysis of water samples was used. For both FIA and on-column analysis, signal intensity and signal-to-noise (S/N) ratio of the target analytes in the three sources were studied. Limits of detection and matrix effects during the analysis of wastewater samples were also investigated. ESI generated significantly larger peak areas and higher S/N ratios than APCI and APPI in FIA and in on-column analysis. ESI was proved to be the most suitable ionization method as it enabled the detection of the five target compounds, whereas APCI and APPI ionized only four compounds.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号