首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Determination of salbutamol using sequential injection analysis (SIA) with chemiluminescence and fluorescence detection has been devised. The chemiluminescence signal was emitted during the oxidation of salbutamol by potassium permanganate in sulfuric acid medium. Sodium polyphosphate was used as chemiluminescence enhancer. The fluorescence signal (excitation wavelength 230 nm) was also measured in sulfuric acid medium. Both detection techniques were compared with respect to the application of the methods to the determination of salbutamol in biological materials. The sample pre-treatment takes place directly in the SIA system, when salbutamol is adsorbed on the solid-phase (Baker-carboxylic acid) microcolumn integrated into the system. Sulfuric acid serves both as the reagent and the eluent. The lab-made SIA system consisted of a 2.5-mL Cavro syringe pump, ten-port Vici Valco selection valve and Spectra-Physics FS 970 fluorescence detector, which was lab-modified for chemiluminescence detection. The system was controlled by a PC using originally compiled LabVIEW-supported software. Concentrations, volumes of reagents and flow rates were optimised by a simplex method. Salbutamol was determined in the linear range 0.05-10 microg mL(-1) (RSD 1.53%), with the detection limit (3 sigma) 0.03 microg mL(-1) and sample throughput of 42 samples per hour with chemiluminescence detection in standard solutions. The fluorescence detection enabled the determination of salbutamol in standard solutions in the linear range 0.5-100 microg mL(-1) (RSD 2.69%), with the detection limit 0.2 microg mL(-1) and sample throughput of 24 h(-1). The proposed methods were applied to the determination of salbutamol in human serum and urine. However, serum is a very complicated matrix and the SIA-SPE analysis did not provide satisfactory results. It was possible to determine salbutamol in human urine using this technique. Better recovery was achieved with fluorescence detection.  相似文献   

2.
张名均  丁世家  易钢 《色谱》2004,22(4):416-419
建立了同时分离检测尿中新喋呤(neopterin,NP)和生物喋呤(biopterin,BP)的高效液相色谱(HPLC)-荧光检测方法。采用Hypersil BDS C18柱、甲醇-水(体积比为10∶90)流动相(流速0.5 mL/min)、激发波长360 nm、发射波长 440 nm、柱温20 ℃的色谱条件,同时分离测定了尿中的NP和BP。尿标本经三氯乙酸处理,在4 ℃下,以12000 r/min的速率离心15 min,上清液用碱中和后,取30 μL直接进样。研究结果表明,NP的线性范围为0.12~10  相似文献   

3.
A capillary electrophoresis coupling with indirect chemiluminescence detection method for the simultaneous determination of benserazide and levodopa has been developed. The detection interface was improved to simplify the capillary electrophoresis-chemiluminescence (CE-CL) system and the features of this improved interface were illustrated in this paper. The CE-CL conditions for the simultaneous determination of benserazide and levodopa were optimized. Under the optimal conditions, the CL intensity was linear with concentrations of levodopa in the range of 1.0 to 100.0 microg ml(-1), and benserazide in the range of 10.0 to 1,000 microg ml(-1), respectively. The detection limits (S/N=3) in turn were 1.85 microg ml(-1) for BS and 0.12 microg ml(-1) for L-dopa with relative standard deviations of less than 3%. The proposed method has been successfully applied to the determination of benserazide and levodopa in medopar tablets and spiked urine samples, demonstrating the feasibility and reliability of the proposed method.  相似文献   

4.
A rapid and simple high-performance liquid chromatographic method with photodiode array detection was developed for the separation and the simultaneous determination of phenytoin and dextromethorphan in human urine. Analysis was performed in less than 4.5 min in isocratic mode on a reversed-phase C18 column (5 microm; 150 x 4.6 mm) using a mobile phase composed of acetonitrile-buffer phosphate 0.01 M (60:40, v/v) adjusted to pH 6.0, at 1 mL/min flow rate and UV absorbance at 210 nm. The elution order of analytes was dextromethorphan (DXM), Internal Standard (IS), and phenytoin (PHT). Calibration curves were linear in the 7.5-25 microg/mL range for PHT and in the 10-30 microg/mL range for DXM. Spike recoveries for urine samples prepared at three spiking levels ranged from 97.8 to 102.3% for PHT and from 94.8 to 100.4% for DXM. The detection limit (LOD) values ranged from 0.08 microg/mL for PHT to 0.5 microg/mL for DXM. The quantitation limit (LOQ) values ranged from 0.3 microg/mL for PHT to 1.6 microg/mL for DXM. The sample preparation method involves a rapid and simple procedure based on solid-phase extraction using a C18 reversed-phase column. Validation of the optimised method was carried out according to the ICH guidelines. The method developed in this study allows the reliable simultaneous analysis of PHT and DXM, drugs that were never quantified together in previously reported analytical methods. The described method has the advantage of being rapid and easy and it could be applied in therapeutic monitoring of these drugs in human urine of epileptic patients.  相似文献   

5.
A capillary electrophoresis method with UV detection was developed for the determination of 8-hydroxy-2'-deoxyguanosine (8-OHdG) in untreated urine samples. The calibration graph for 8-OHdG in urine is linear in the concentration range 10-500 mg/l. and the detection limit is 5 mg/l (17 microM). 8-OHdG was determined in urine from oncological patients treated by radiation therapy. Its concentrations relative to creatinine were found to be in the range 10-47 microg 8-OHdG/l mg creatinine (4-19 micromol 8-OHdG/mmol creatinine). The overall time of the analysis of a urine sample was less than 15 min.  相似文献   

6.
In this work, a fast, simple and economic method is proposed for the determination of imazalil in water samples by flow injection photoinduced chemiluminescence. In this method, imazalil degrades in basic media through the use of a photoreactor, and the resulting photofragments react with ferricyanide and generate the direct chemiluminescence signal. To the authors' knowledge, this is the first time that a chemiluminescence method has been proposed for the determination of this fungicide. All physical and chemical parameters in the flow injection chemiluminescence system were optimized in the experimental setting. In the absence of preconcentration, the linear dynamic range for imazalil was 0.75-5 mg L(-1) and the detection limit was 0.171 mg L(-1). The application of solid-phase extraction with C18 cartridges allowed the elimination of interference ions, the reduction of the linear dynamic range to 15-100 μg L(-1), and a detection limit of 3.4 μg L(-1). This detection limit is below the maximum concentration level established by the Regulations of the Hydraulic Public Domain for pesticide dumping. The sample throughput after solid-phase extraction of the analyte was 12 samples h(-1). The intraday and interday coefficients of variation were below 9.9% in all cases. This method was applied to the analysis of environmental water samples, and recoveries of between 95.7 and 110% were obtained.  相似文献   

7.
This paper reports, for the first time, a liquid chromatographic method for the simultaneous determination of three frequently co-administered active principles, two antibiotics, ciprofloxacin (CIPRO) and cloxacillin (CLOXA) belonging to the fluoroquinolones and beta-lactam families, respectively, and ibuprofen (IBU), a non-steroidal anti-inflammatory drug. The chromatographic separation was performed on a C-18 analytical column, using isocratic elution with methanol-acetonitrile-pH 3 formate buffer (CT = 0.1 M) (15:12:73, v/v/v) for 3 min and, after that, a linear gradient with methanol-acetonitrile (88:12, v/v) for 8 min. Several absorption spectra were obtained for each peak using a DAD detector. Chromatograms at the maximum absorption wavelength for each analyte, 220 nm for both IBU and CLOXA, and 280 nm for CIPRO were selected as the most suitable. The proposed chromatographic method requires about 15 min per sample. The presence of a urine background was tested and no interference was found. The method was satisfactorily applied to the determination of CIPRO, CLOXA, and IBU, in fortified urine, and in urine samples from a patient undergoing treatment with these three active principles, among others. Limits of quantification in urine were 1.00, 1.70, and 2.87 microg/mL for CIPRO, CLOXA, and IBU, respectively.  相似文献   

8.
Lin H  Lin Q  Zhang Y  Zhang J  Chen L 《色谱》2012,30(4):374-377
采用戴安公司谱睿(Pre)在线样品除氯技术,结合OnGuard Ba柱去除硫酸盐,建立了离子色谱直接测定海水中亚硝酸盐、硝酸盐和磷酸盐的方法。该方法以IonPac AG23为富集柱,高容量IonPac AS23为分离柱,淋洗液自动发生装置在线产生KOH溶液进行梯度淋洗,抑制电导检测。实验结果表明: 样品稀释5~10倍时,直接进样不会干扰目标物测定。当流速为1 mL/min、进样量为500 μL时,海水中NO~2-N、NO~3-N、PO3~4-P的方法检出限分别为0.3、0.4、0.2 μg/L,线性范围分别为10~500 μg/L、14~680 μg/L、3.4~170 μg/L,线性相关系数r均大于0.9990。测得人工海水样品中目标物的加标回收率为92%~106%,相对标准偏差(RSD, n=6)为1.2%~7.7%。该方法一次进样可在13 min内完成分析,具有操作简单快捷、无污染等优点,能满足近海海水中NO~2、NO~3、PO3~4的定量分析要求。  相似文献   

9.
A simple head-space (HS) flow injection (FI) system with chemiluminescence (CL) detection for the determination of iodide as iodine in urine is presented. The iodide is converted to iodine by potassium dichromate under stirring in the closed HS vial, and the iodine is released from urine by thermostatting and is carried in a nitrogen flow through an iodide trapping solution. The concomitant introduction of aliquots of iodine, luminol and cobalt(II) solutions by means of a time-based injector into an FI system allowed its mixing in a flow-through cell in front of the detector. The emission intensity at 425 nm was recorded as a function of time. The salting-out of the standard solutions affected the gas-liquid distribution coefficient of iodine in the HS vial. The typical analytical working graphs obtained under the optimized experimental conditions were rectilinear from 0 to 5 mg l(-1) iodine, achieving a precision of 2.3 and a relative standard deviation of 1.8 for ten replicate analyses of 50 and 200 microg l(-1) iodine. However, a second-order process becomes significant at higher iodine concentrations (from 10 to 40 mg l(-1)). The detection limit of the method is 10 microg l(-1) (80 ng) iodine when 8 ml samples are taken. Data for the iodide content of 10 urine samples were in good agreement with those obtained by a conventional catalytic method, and recoveries varied between 101 and 103% for urine samples spiked with different amounts of iodide. The analysis of one sample takes less than 20 min. In the present study the iodide levels found for 100 subjects were 86.8 +/- 19.0 (61-125) microg l(-1), which is lower than the WHO's optimal level (150-300 microg per day).  相似文献   

10.
建立了人尿中R,S-美芬妥英的气相色谱(GC)手性分离与检测方法。在选定的色谱条件下能很好地分离R,S-美芬妥英,尿中其它物质无干扰。用外标法定量,线性范围为12.5~2500μg/L尿,最小检出浓度为6μg/L尿。方法具有样本制备简便、分析时间短、线性范围宽、干扰少、灵敏和准确等优点,已广泛用于人体内美芬妥英代谢的研究和肝药酶CYP2C19酶活性的检测。  相似文献   

11.
A new method was developed and validated for the determination of chlorophenols in human urine by using micellar electrokinetic chromatography (MEKC) coupled via a mechanic arm to an on-line automatic clean-up and preconcentration unit for urine samples. Separation is accomplished by using a selective buffer consisting of 15 mM borate, 25 mM phosphate and 100 mM sodium dodecyl sulfate (SDS) at pH 9.1 in addition to a positive power supply of 25 kV at 18 degrees C. The proposed capillary electrophoresis (CE) method allows the separation of 11 chlorophenols within 7 min with a reproducibility as relative standard deviation (RSD) between 2.6% and 7.2%, and limits of detection (LODs) between 0.08 and 0.46 microg/mL for all chlorophenols. Urine samples were previously hydrolyzed with 37% HCl at 80 degrees C for 60 min and then cleaned on a C-18 mini-column. Recoveries ranged from 58% to 103%. The preconcentration treatment affords limits of determination between 4 and 12 ng/mL for all chlorophenols except pentachlorophenol and 4-chlorophenol, which could not be determined. The overall analysis time, including on-line clean-up, preconcentration and electrophoretic separation is 20 min per sample.  相似文献   

12.
A reversed-phase high-performance liquid chromatography (rp-HPLC) system interfaced with an electrospray ionization (ESI) source coupled to tandem mass spectrometry (MS/MS) was developed and validated for the determination of cyclophosphamide (CP), ifosfamide (IF), daunorubicin (DNR), doxorubicin (DXR), and epirubicin (EPI) in human urine. The analysis of samples containing multiple analytes with a dissimilar range of polarities was carried out using a conventional reversed-phase chromatographic BDS Hypersil C8 column. The analytical run was 15 min. The triple quadrupole mass spectrometer was operated in positive ion mode and multiple reaction monitoring (MRM) was used for drug quantification. The method was validated over a concentration range of 0.2 to 4.0 microg.L(-1) for CP, IF, DXR, EPI and 0.15-2.0 microg.L(-1) for DNR in human urine. The lower limit of quantification (LLOQ) was 0.2 microg.L(-1) for CP, IF, EPI and was set at 0.3 and 0.15 microg.L(-1) for DXR and DNR, respectively. The relative standard deviations (RSD%) were <11.2% for inter- and intra-day precisions. The overall accuracy was also within 114.7% for all analytes at the concentrations of the quality control samples. The potential of ionization suppression resulting from the endogenous biological material on the rp-HPLC/MS/MS method was evaluated and measured. The feasibility of the proposed HPLC/ESI-MS/MS procedure was demonstrated by analyzing urine samples from pharmacy technicians and nurses working in hospitals or personnel employed in drug-manufacturing plants.  相似文献   

13.
A sensitive method for the determination of 3 alpha,5 beta-tetrahydroaldosterone (THALD) in human urine is described. The method uses high-performance liquid chromatography with chemiluminescence detection. Urinary THALD, released by enzyme hydrolysis, is isolated and concentrated using a Sephadex G-25M column and Bond-Elut C1 cartridges, and then oxidized by copper(II) acetate to form the corresponding glyoxal derivative. The glyoxal derivative is converted into the chemiluminescent quinoxaline by reaction with 4,5-diaminophthalhydrazide. The chemiluminescent quinoxaline is separated within 50 min on a reversed-phase column (TSKgel ODS-120T) with isocratic elution, followed by chemiluminescence detection; the chemiluminescence is produced by the reaction of the quinoxaline with hydrogen peroxide in the presence of potassium hexacyanoferrate(III) in alkaline solution. The detection limit for THALD is 0.6 pmol (220 pg) ml-1 in urine [1.5 fmol (0.53 pg) per 20 microliters injection] at a signal-to-noise ratio of 3. This method permits the sensitive and precise determination of THALD in human urine (50 microliters) from normal subjects and a patient with primary aldosteronism.  相似文献   

14.
A sensitive, rapid and selective procedure is proposed for the flow injection determinations of periodate by spectrofluorometric detection. The method is based on the reaction of periodate with Alizarin Navy Blue in basic solution. The reagents and manifold variables influence on the sensitivity have been investigated and the optimum conditions are established. Periodate can be determined for the range of 0.250-5.00 microg ml(-1) with a limit of detection of 0.08 microg ml(-1), and with a sample rate of 15 +/- 2 samples h(-1). The relative standard deviations for eight replicate determination of 0.500 and 5.00 microg ml(-1) was 1.3 and 1.1%, respectively. Periodate can be determined in the presence of iodate and bromate. The proposed method was used to determination of periodate in water samples.  相似文献   

15.
Methods for the direct determination of Ni in human blood serum and urine by electrothermal atomic absorption spectrometry (ETAAS) are described. Hydrogen peroxide was proposed as matrix modifier, assisting thermal decomposition of proteins during the ashing step. A pyrolysis temperature of 1,200 degrees C was found to be optimal while 2,100 degrees C and 2,200 degrees C were found to be optimal atomizing temperatures for Ni in serum and urine respectively. Calibration was performed by using a calibration curve prepared with aqueous standard solutions of Ni (glycine must be used as modifier for Ni in aqueous solutions). The limits of detection, defined as the blank values plus 3 times the standard deviation of the blank values, were 0.2 microg/L for both serum and urine samples. Relative standard deviations for serum samples with concentrations of Ni in the range 0.5-2 microg/L were 10-15% and for urine samples with Ni concentrations in the range 0.5-2.5 microg/L were 8-10%.  相似文献   

16.
基于酸性条件下甲醛对尿酸-KMnO4发光反应的增敏作用,建立了在线稀释顺序注射化学发光联用技术测定人体液中尿酸的新方法。在选定的实验条件下的7个浓度梯度范围内,尿酸浓度在5.0×10-6mol/L~1.0×10-3mol/L范围内与发光强度呈良好线性关系,相关系数0.9942~0.9998,RSD在2.0%~3.5%之间,回收率为98.0%~103.0%。每小时可分析80个样品,在线稀释测定结果与手工稀释法一致。  相似文献   

17.
This work relates the development of an analytical methodology to simultaneously determine three methylxanthines (caffeine, theobromine, and theophylline) in beverages and urine samples based on reversed-phase high-performance liquid chromatography. Separation is made with a Bondesil C18 column using methanol-water-acetic acid or ethanol-water-acetic acid (20:75:5, v/v/v) as the mobile phase at 0.7 mL/min. Identification is made by absorbance detection at 273 nm. Under optimized conditions, the detection limit of the HPLC method is 0.1 pg/mL for all three methylxanthines. This method is applied to urine and to 25 different beverage samples, which included coffee, tea, chocolate, and coconut water. The concentration ranges determined in the beverages and urine are: < 0.1 pg/mL to 350 microg/mL and 3.21 microg/mL to 71.2 microg/mL for caffeine; < 0.1 pg/mL to 32 microg mL and < 0.1 pg/mL to 13.2 microg/mL for theobromine; < 0.1 pg/mL to 47 microg/mL and < 0.1 pg/mL to 66.3 microg/mL for theophylline. The method proposed in this study is rapid and suitable for the simultaneous quantitation of methylxanthines in beverages and human urine samples and requires no extraction step or derivatization.  相似文献   

18.
A simple, selective, sensitive, accurate, and precise method was developed for determination of metformin hydrochloride (MF) in human urine using RP-HPLC. The method depends upon using an octylsilyl (C8) 5 microm particle size column at ambient temperature with mobile phase consisting of 33 mM sodium dihydrogen phosphate containing 6.38 mM hexanesulfonic acid sodium salt and adjusted to apparent pH 3.0 with phosphoric acid-acetonitrile (93 + 7, v/v) at a flow rate of 1.5 mL/min. Quantitation was achieved with UV detection at 231 nm based on peak area with a linear calibration curve over the concentration range of 0.01-50 microg/mL. The proposed method was applied to the determination of the urinary excretion pattern of MF (the cumulative amounts excreted were calculated without pretreatment of the urine sample) and for determination of the dissolution pattern of MF tablets. The proposed method was completely validated according to the U.S. Food and Drug Administration guidelines.  相似文献   

19.
The determination of four Sudan dyes by means of high-performance liquid chromatography (HPLC) with chemiluminescence (CL) detection was proposed. The method was based on the enhancement effect of Sudan dyes on the chemiluminescence reaction between luminol and BrO-, which was on-line electrogenerated by constant current electrolysis. The separation was carried out on Nucleosil RP-C18 column (250 mm x 4.6 mm i.d., 5 microm, pore size, 100 A) at 35 degrees C. The mobile phase consisted of a V (methanol): V (0.2% aqueous formic acid) = 90:10 solution. At a flow-rate of 1.0 ml min(-1), the total run time was 25 min. The effects of several parameters on the HPLC resolution and CL emission were studied systematically. For the four Sudan dyes, the limits of detection (LOD) at a signal-to-noise of 3 ranged from 4 to 8 microg kg(-1) and the limits of quantification (LOQ) at a signal-to-noise of 10 ranged from 13 to 27 microg kg(-1). The relative standard deviations (RSD) of intra-and inter-day precision were below 4.4%. The average recoveries for all four Sudan dyes (spiked at the levels of 1.0 and 1.5 mg kg(-1)) in chilli tomato sauce and hot chilli pepper ranged from 94% to 105%, and the relative standard deviations of the quantitative results were from 2.5 to 4.2%. The proposed method had been successfully applied to the determination of four Sudan dyes in hot chilli products.  相似文献   

20.
Wang Y  Yang J  Cai Y  Lin X  Li H 《色谱》2011,29(12):1230-1235
以4-氯-7-硝基苯并-2-氧杂-1,3-二唑(NBD-Cl)为柱前衍生试剂,建立了胶束电动色谱-激光诱导荧光检测法测定肌松弛药巴氯芬(BAL)的新方法。经过实验条件的优化,采用15 mmol/L硼砂、20 mmol/L十二烷基硫酸钠、10%(v/v)乙腈、pH 9.75的缓冲体系,在分离电压为17.5 kV、柱温为25 ℃的条件下,压力进样3.45 kPa(0.5 psi)×3 s,巴氯芬及其内标物的衍生产物在7 min内实现较好的基线分离,线性范围为0.025~25 mg/L,相关系数为0.9999,检出限(S/N=3)和定量限(S/N=10)分别为0.90 μg/L和6.25 μg/L。该方法被应用于巴氯芬制剂及加入巴氯芬对照品的尿液样品分析,回收率范围分别为101.6%~107.9%和107.0%~109.6%。该方法有望应用于巴氯芬药物制剂的质量监控以及为巴氯芬药物代谢的研究提供辅助手段。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号