The performance of a monolithic silica capillary column coated with poly(octadecyl methacrylate) (ODM column) for the reversed-phase liquid chromatographic separation of some polar and non-polar compounds was studied, and the results were compared to those obtained by using a monolithic silica capillary column modified with octadecylsilyl-(N,N-diethylamino)silane (ODS column). Benzene and naphthalene derivatives, polycyclic aromatic hydrocarbons (PAHs), steroids, alkyl phthalates, and tocopherol homologues were used as test samples. In general, compounds with aromatic character, rigid and planar structures, and lower length-to-breadth ratios (more compacted structures) seem to have more preference for the polymer coated stationary phase (ODM). Compounds with acidic character have also a higher retention on ODM columns because of the presence of ester groups in the stationary phase. The polymer coated column allowed the separation of some PAHs, alkyl phthalates, steroids, and of beta- and gamma-tocopherol isomers which cannot be separated under the same conditions on ODS columns, while keeping similar column efficiency. These results allowed to suggest ODM columns as a good alternative to conventional ODS columns for reversed-phase liquid chromatography.  相似文献   

2.
A practical investigation of frictional heating effects in conventional C18 columns was undertaken, to investigate whether problems found for sub-2 μm columns were also present for those of particle size 3 μm and 5 μm and different internal diameter. The influence of a water bath, a still air heater, and a forced air heater on performance was investigated. Heating effects were substantial, with a decrease in k of almost 15% for toluene over the flow rate range ∼0.4–2.3 mL/min with a 15 cm × 0.46 cm ID column packed with 3 μm particles. Heating effects on retention increased with increasing solute k, with increase in the column ID, with decrease in the column particle size, and with decrease in the set column oven temperature. While the water bath minimised axial temperature gradients and thus its effect on k, radial temperature gradients were potentially serious with this system, especially at high mobile phase velocity, even with columns containing 5 μm particles. In contrast to the effects of axial temperature gradients in 4.6 mm columns, very little difference in Van Deemter plots was noted between the three different thermostats with 2 mm ID columns, even when 3 μm particles were used. However, the efficiency of 2 mm columns for peaks of low or moderate k (k < 4) can be compromised by the extra dead volume introduced by the heating systems, even with conventional HPLC systems with otherwise minimised extra column volume.  相似文献   

3.
A systematic investigation was undertaken into the relative separation performance of five reversed-phase chromatography columns including some commercially new hybrid packed columns for a series of polycarboxylic acids and polyphenol compounds. Information theory (IT) and factor analysis (FA), together with a basic evaluation of retention information (band shape, retention factor and elution order) were used to compare four columns to a conventional C18 column. The results revealed very little difference in retention behaviour between the Phenomenex Aqua C18 column, the Waters XTerra RP C18 column, and the conventional Phenomenex Luna C18 column. However, there were notable differences in the retention processes between the Phenomenex Synergi polar-RP column, which is an ether-linked phenyl base with polar endcapping, and the Luna C18 column. The most significant differences were observed between the Luna C18 column and a Phenomenex Luna Cyano column. However, the limited degree of retention of the polycarboxylic acids and polyphenol compounds on the Luna Cyano column permits only limited use for the separation of these types of compounds. Overall, the Phenomenex Synergi polar-RP column exhibited the best performance for the separation of the test solutes compared to that of the conventional C18 column, with IT yielding an Informational Similarity of 0.99 and FA a moderate correlation coefficient of 0.70. The Phenomenex Synergi polar-RP column gave the best peak shape and offered substantial selectivity differences thereby providing a good alternative over the conventional C18 column for separating polycarboxylic acids and polyphenols.  相似文献   

4.
This work reports the first use of a monolith with method development for the separation of tocopherol (TOH) compounds by CEC with UV detection. A pentaerythritol diacrylate monostearate-ethylene dimethacrylate (PEDAS-EDMA) monolithic column has been investigated for an optimised condition to separate alpha-, beta-, gamma- and delta-TOHs, and alpha-tocopherol acetate (TAc). The PEDAS-EDMA monolith showed a remarkably good selectivity for separation of the TOH isomers including the beta- and gamma-isomers which are not easily separated by standard C8 or C18 particle-packed columns. Retention studies indicated that an RP mechanism was involved in the separation on the PEDAS-EDMA column, but polar interactions with the underlying ester and hydroxyl groups enhanced the separation of the problematic beta- and gamma-isomers. Separation of all the compounds was achieved within 25 min using 3:10:87 v/v/v 100 mM Tris buffer (pH 9.3)/methanol/ACN as the mobile phase. The method was successfully applied to a pharmaceutical sample with recoveries from 93 to 99%. Intraday and interday precisions (%RSD) for peak area and retention time were less than 2.3. LODs for all four TOHs and TAc were below 1 ppm.  相似文献   

5.
Strongly polar phenolic acids are weakly retained and often poorly separated in reversed-phase (RP) liquid chromatography. We prepared zwitterionic polymethacrylate monolithic columns for micro-HPLC by in situ co-polymerization in fused-silica capillaries. The capillary monolithic columns prepared under optimized polymerization conditions show some similarities with the conventional particulate commercial ZIC-HILIC silica-based columns, however have higher retention and better separation selectivity under reversed-phase conditions, so that they can be employed for dual-mode HILIC-RP separations of phenolic acids on a single column. The capillary polymethacrylate monolithic sulfobetaine columns show excellent thermal stability and improved performance at temperatures 60–80 °C. The effects of the operation conditions on separation were investigated, including the type and the concentration of the organic solvent in the aqueous-organic mobile phase (acetonitrile and methanol), the ionic strength of the acetate buffer and temperature. While the retention in the RP mode decreases at higher temperatures in mobile phases with relatively low concentrations of acetonitrile, it is almost independent of temperature at HILIC conditions in highly organic mobile phases. The best separation efficiency can be achieved using relatively high acetate buffer ionic strength (20–30 mmol L−1) and gradient elution with alternately increasing (HILIC mode) and decreasing (RP mode) concentration of aqueous buffer in aqueous acetonitrile. Applications of the monolithic sulfobetaine capillary columns in alternating HILIC-RP modes are demonstrated on the analysis of phenolic acids in a beer sample.  相似文献   

6.
A new method for the fixation of polymethacrylate monoliths within titanium tubing of up to 0.8 mm I.D. for use as a chromatographic column under elevated temperatures and pressures is described. The preparation of butyl methacrylate–ethylene dimethacrylate-based monolithic stationary phases with desired porous structures was achieved within titanium tubing with pre-oxidised internal walls. The oxidised titanium surface was subsequently silanised with 3-trimethoxysilylpropyl methacrylate resulting in tight bonding of butyl methacrylate porous monolith to the internal walls, providing stationary phase stability at column temperatures up to 110 °C and at operating column pressure drops of >28 MPa. The titanium housed monoliths exhibited a uniform and dense porous structure, which provided peak efficiencies of up to 59,000 theoretical plates per meter when evaluated for the separation of small molecules in reversed-phase mode, under optimal conditions (achieved at 15 μL/min and temperature of 110 °C for naphthalene with a retention factor, k = 0.58). The developed column was applied to the reversed-phase isocratic separation of a text mixture of pesticides.  相似文献   

7.
The performance of isocratic separations of 11 pollutant phenols (PP) using monolithic (Chromolith RP-18e) and conventional reversed-phase 5 microm (Luna and Purospher C18) and 4 microm (Synergi C12) particulate size columns, selected from high purity silica materials, has been compared. The separations have been optimized based on a previously optimized separation in which a reversed-phase C18 Luna column and acetonitrile as organic modifier were used, allowing the separation of all phenols tested in 23 min. The optimization process was carried out for each column by studying the effect of the mobile phase (acetonitrile as organic modifier, pH, flow-rate) on phenols separation. Under the optimized separation conditions, all phenols were separated in less than 23 min for all columns tested. Asymmetry factors were further evaluated and used to estimate column efficiency using the Dorsey-Foley equation. The efficiency and asymmetry factors were lower for Chromolith than for Purospher and Luna columns respectively. The Chromolith column was finally selected, due to its lower flow resistance, analysis time and good efficiency and asymmetry factors. The PPs separation was achieved in 3 min. The asymmetry factors were in the range 0.9-1.5 using 50mM acetate buffer (pH = 5.25)-ACN (64:36, v/v) as mobile phase, T=45 degrees C and 4.0 ml min(-1) flow-rate.  相似文献   

8.
The contribution of cation exchange to solute retention for type-B alkylsilica columns (made from high-purity silica) has been examined in terms of the hydrophobic-subtraction (H-S) model of reversed-phase column selectivity. The relative importance of cation exchange in the separation of ionized bases by reversed-phase chromatography (RPC) varies with (a) column acidity (values of the column cation-exchange capacity C), (b) mobile-phase pH and buffer concentration, and (c) the nature of the buffer cation. The effects of each of these separation variables on cation retention were examined. The contribution of cation exchange (and other ionic interactions) to solute retention is represented in the H-S model by properties of the solute (κ') and column (C), respectively. Values of κ' for 87 solutes have been examined as a function of solute molecular structure, and values of C for 167 type-B alkylsilica columns have been related to various column properties: ligand length (e.g., C(8) vs. C(18)) and concentration (μmol/m(2)), pore diameter (nm), and end-capping. These results contribute to a more detailed picture of the retention of cationic solutes in RPC as a function of separation conditions. While previous work suggests that the ionization of type-B alkylsilica columns is generally negligible with mobile-phase pH<7 (as a result of which cation exchange then becomes insignificant), the present study provides evidence for cation exchange (and presumably silanol ionization) at a pH as low as 3 for most columns.  相似文献   

9.
A jet of cool gas is used to locally cool a section of modulator tube in the presence of the stirred oven bath of a GC×GC instrument. Local cooling decouples the temperature of the modulator tube from that of the first dimension column, which was 100 meters long. Overall resolution of the GC×GC experiment was improved as a result. Another consequence of the jet‐cooled thermal modulation structure is the elimination of moving parts in the GC oven. By pulsing cold and hot jets of gas onto a modulator tube with solenoid valves, two stage thermal modulation can be obtained without the complexity of moving parts in the vicinity of the capillary columns.  相似文献   

10.
In order to develop a portable and disposable instrument for on-site analysis of neutral compounds, a lauryl methacrylate monolith has been synthesized into a cyclic olefin copolymer microdevice for reversed-phase electrochromatography purposes. This monolith was tested in capillary to evaluate electrochromatographic performances in terms of electroosmotic flow (EOF) mobility, retention and efficiency prior to its transfer into the microfluidic device. The produced monolithic bed exhibited a good run-to-run repeatability, column-to-column reproducibility and batch-to-batch reproducibility, with relative standard deviation (RSD) values below 9% for EOF mobility, retention factors and heights of theoretical plate. The electrochromatographic performances of the monolith were optimized by reducing irradiation time. Photopolymerization time of 10 min was found to be the best process in order to obtain a robust, retentive and efficient system. The on-chip performances of this monolith were evaluated in detail for the reversed-phase electrochromatographic separation of polycyclic aromatic hydrocarbons, with plate heights reaching down to 15 μm when working at optimal velocity. Aiming at the maximum simplification of instrumental fabrication and operation, a direct injection from a 2 μL droplet was compared with more conventional dynamic injection process.  相似文献   

11.
In this study, the analysis of a peptide set, chosen for their differences in hydrophilicity, and the tryptic digests of bovine cytochrome c and β-lactoglobulin by hydrophilic interaction chromatography–electrospray ionisation mass spectrometry (HILIC–ESI-MS) is demonstrated. Two different types of HILIC phases, i.e., an amide- and an amino-modified silica-based phase, packed into narrow bore or capillary columns, were investigated with separations conducted under either low pH or neutral pH conditions. The separation performance of the two HILIC columns with respect to peak efficiency and selectivity have been documented under these different mobile phase conditions, and the results compared with the performance of a conventional capillary reversed-phase C18 column of similar dimensions. It was found that very good separation of the peptide set could be achieved by using the amide-modified silica column over a broad pH range. Moreover, with the protein digest samples, excellent separation of the tryptic digests was obtained with the amide-modified HILIC column under neutral pH conditions. Compared to the conventional reversed-phase C18 separations, the use of these HILIC columns not only provided complementary separation selectivity, but also offered the capability to identify unique peptides using tandem HILIC–mass spectrometric techniques. These studies therefore highlight the potential of HILIC procedures for future proteomic applications.  相似文献   

12.
Recently, hydrophilic interaction chromatography (HILIC) has emerged as a valuable orthogonal tool to reversed-phase liquid chromatography (RP-LC) as it allows for resolution of highly polar ionisable compounds. The relationships between separation efficiency, column length and speed of analysis for 4.6 mm ID × 5 μm silica particle columns in HILIC are demonstrated using kinetic plots. The kinetic plots constructed for conventional pressure systems operating at 350 bar and at 30 °C and 80 °C are confirmed using experimental data for different column lengths. Efficiencies of more than 130,000 theoretical plates could be achieved by connecting up to six columns of 25 cm. As expected, a significant gain in analysis speed without loss of efficiency could be obtained by operating at 80 °C compared to 30 °C. The advantages of using long columns in HILIC in combination with elevated column temperature for the pharmaceutical industry are illustrated using test mixtures comprised of commercially available ionisable compounds (including some containing functional groups with potential genotoxic typical structural alerts) as well as real polar ionisable pharmaceuticals.  相似文献   

13.
Monolithic columns are widely used in shotgun proteome analysis. However, it is difficult to increase the separation capability and proteome coverage by using conventionally organic polymer-based monolithic column due to the difficulty of controlling homogeneity of the overall pore structure (both pores and microglobules), which leads to relatively low column efficiency. Therefore, we studied the effect of constitute and percentage of porogenic solvent, functional monomer, column length, and separation gradient on the peak capacity and proteome coverage by methacrylate-based reversed phase monolithic columns. It was demonstrated that the porous property of the hydrophobic monolith, which was mainly determined by the porogenic solvent, was crucial to the proteome coverage when similar methacrylate monomer was utilized and a ternary porogenic solvent was adopted to prepare C12 monolithic column with relatively homogeneous overall pore structure. It was also shown that high proteome coverage could be reliably obtained with online multidimensional separation using totally monolithic columns system with the length of analytical column at 85 cm and reversed phase separation gradient at 210 min.  相似文献   

14.
Xiangli Sun  Yukui Zhang 《Talanta》2010,82(1):404-5307
A simple one-step in situ “click” modification strategy was developed for the preparation of hydrophobic organic monolithic columns for the first time. The column morphology and surface chemistry of the fabricated monolithic columns were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy and X-ray photoelectron spectroscopy, respectively. The chromatographic performances of the C8/C18 “click” monoliths were evaluated through the separation of a mixture of five proteins such as ribonuclease A, soybean trypsin inhibitor, cytochrome c, bovine haemoglobin and bovine serum albumin. Compared with the blank column, the higher hydrophobicity stationary phases obtained from the “clicked” modification have longer retention times and higher resolution for the five proteins. The separation of five proteins mixture on click C18 monolith with gradient elution at different flow rates was also investigated, the baseline separation of five proteins could be achieved at three different flow rates.  相似文献   

15.
The separation selectivity of octadecyl-silica (C18) and of bonded pentafluorophenylpropyl-silica (F5) and PEG-silica columns was compared for natural phenolic antioxidants. The separation selectivities for phenolic antioxidants on C18 and F5 columns are strongly correlated, but low selectivity correlation indicating strong differences in the retention mechanism was observed between the C18 and PEG columns. Hence, the combination of a C18 and a PEG column is useful for separation of phenolic antioxidants that are not fully separated on single columns. Two-dimensional comprehensive liquid chromatography using a short PEG-silica column in the first dimension and a conventional C18-silica in the second dimension has the advantage of on-column focusing of the fractions transferred onto the C18 column in the second dimension, as a weaker mobile phase is used in the first dimension than in the second dimension. However, a stop-flow set-up in the first dimension system is necessary after the transfer of each fraction to the second dimension. Peak capacity is considerably larger but the separation time is much longer than with serially coupled PEG and C18 columns, which were employed for separation of beer and hop extract samples in connection with coulometric detection.  相似文献   

16.
A novel resistive heating method is presented for subcritical water chromatography (SWC) that provides higher column heating rates than those conventionally obtained from temperature-programmed gas chromatography (GC) convection ovens. Since the polarity of water reduces dramatically with increasing temperature, SWC employs column heating to achieve gradient elution. As such, the rate at which the mobile phase is heated directly impacts the magnitude of such gradients applied in SWC. Data from the current study demonstrate that the maximum column heating rate attainable in a typical SWC apparatus (i.e. using a GC convection oven) is around 10 degrees C/min, even at instrument oven settings of over three times this value. Conversely, by wrapping the separation column with ceramic insulation and a resistively heated wire, the column heating rates are increased five-fold. As a result, elution times can be greatly decreased in SWC employing gradients. Separations of standard alcohol test mixtures demonstrate that the retention time of the latest eluting component decreases by 35 to 50% using the prototype method. Additionally, solute retention times in this mode deviate by less than 1% RSD over several trials, which compares very well to those obtained using a conventional GC convection oven. Results suggest that the developed method can be a useful alternative heating technique in SWC.  相似文献   

17.
Different RP-HPLC columns (phenyl, conventional ODS, cross-linked C(18) and special end-capped C(8) and C(18) phases) were used to investigate the separation of four basic ionizable isomers. Using ACN/20mM NH(4)OAc aq., a separation was observed exclusively on RP columns with higher silanol activity at unusual high ACN concentration, indicating cation-exchange as main retention mechanism. Using MeOH/20mM NH(4)OAc aq., another separation at low MeOH concentrations was observed on both, RP columns with higher as well as RP columns with lower silanol activity, which is mainly based on hydrophobic interactions. The isomers were also separated on a bare silica column at higher MeOH content using NH(4)OAc. Since cation-exchange governs this retention, the elution order was different compared to the RP phases. A strong retention on the silica column was observed in ACN, which could be attributed to partition processes as additional retention mechanism.  相似文献   

18.
A chloropropyl-functionalized silica (CP-silica) hybrid monolithic column was synthesized within the confines of a capillary via the sol–gel process using tetramethoxysilane (TMOS) and (3-chloropropyl)-trimethoxysilane (CPTMS) as the precursors. The resulting CP-silica hybrid monolith inside the capillary showed homogeneous macroporous morphology and was well attached to the inner wall of the capillary. The obtained CP-silica hybrid monolithic capillary column demonstrated the inherent hydrophobic property and could be applied as a reversed-phase stationary phase in CEC directly. Due to the great chemical reactivity of the incorporated chloro groups on the hybrid silica monolithic matrix, the chloropropyl moieties on the surface of the hybrid silica monolith matrix could be conveniently further modified by a tertiary amine of N,N-dimethyl-N-dodecylamine (DMDA) via the nucleophilic substitution reaction at 70 °C to introduce a dodecyl groups (C12) onto the CP-silica hybrid monolithic matrix. The resulting C12-silica hybrid monolithic column not only demonstrated the significantly enhanced hydrophobic property in the separation of alkylbenzenes in reversed-phase capillary electrochromatography (RP-CEC), but also the strong electroosmotic flow (EOF) in a wide pH range. Five alkylbenzenes could be baseline separated in 3 min with column efficiency ranging from 189 700 to 221 000 N/m with a 70% ACN running buffer in CEC.  相似文献   

19.
A silica monolith column (Merck Chromolith, 100 mm x 4.6 mm) has been coated with Dionex AS9-SC latex nanoparticles to convert the column into an anion-exchange stationary phase. For comparison purposes, a reversed-phase silica monolith was also converted into an anion-exchange column by coating with the cationic surfactant didodecyldimethylammonium bromide (DDAB). Separations of common inorganic anions were carried out using 7.5 or 5.0 mM 4-hydroxybenzoic acid at pH 7.0 along with suppressed conductivity detection. Direct comparisons were then made between the two columns in terms of selectivity, efficiency and stability. The latex-coated column was on average 50% more efficient than the DDAB-coated column. A 10% decrease in retention times was observed on the DDAB column over 11 h of continuous eluent flow, while the latex coating exhibited <1% change in retention even after 2.5 months of periodic use.  相似文献   

20.
Chromatographic data were acquired for eight different mixtures, under five different sets of experimental conditions, for a total of 30 neutral, acidic and basic test compounds, on a series of six Chromolith Performance columns from Merck. These columns are made of a C18 chemically bonded silica monolith. Each column belonged to a different production batch, so the data reported here characterize their batch-to-batch reproducibility. The parameters studied in this work were the retention times, the retention and separation factors, the hydrophobic and the steric selectivities, the column efficiencies, and the tailing factors for all 30 compounds.  相似文献   