首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Microchip electrophoresis has become a powerful tool for DNA separation, offering all of the advantages typically associated with miniaturized techniques: high speed, high resolution, ease of automation, and great versatility for both routine and research applications. Various substrate materials have been used to produce microchips for DNA separations, including conventional (glass, silicon, and quartz) and alternative (polymers) platforms. In this study, we perform DNA separation in a simple and low-cost polyester-toner (PeT)-based electrophoresis microchip. PeT devices were fabricated by a direct-printing process using a 600 dpi-resolution laser printer. DNA separations were performed on PeT chip with channels filled with polymer solutions (0.5% m/v hydroxyethylcellulose or hydroxypropylcellulose) at electric fields ranging from 100 to 300 V cm(-1). Separation of DNA fragments between 100 and 1000 bp, with good correlation of the size of DNA fragments and mobility, was achieved in this system. Although the mobility increased with increasing electric field, separations showed the same profile regardless of the electric field. The system provided good separation efficiency (215,000 plates per m for the 500 bp fragment) and the separation was completed in 4 min for 1000 bp fragment ladder. The cost of a given chip is approximately $0.15 and it takes less than 10 minutes to prepare a single device.  相似文献   

2.
Szántai E  Guttman A 《Electrophoresis》2006,27(24):4896-4903
In the past few years, electrophoresis microchips have been increasingly utilized to interrogate genetic variations in the human and other genomes. Microfluidic devices can be readily applied to speed up existing genotyping protocols, in particular the ones that require electric field-mediated separations in conjunction with restriction fragment analysis, DNA sequencing, hybridization-based techniques, allele-specific amplification, heteroduplex analysis, just to list the most important ones. As a result of recent developments, microfabricated electrophoresis devices offer several advantages over conventional slab-gel electrophoresis, such as small sample volume requirement, low reagent consumption, the option of system integration and easy multiplexing. The analysis speed of microchip electrophoresis is significantly higher than that of any other electric field-mediated separation techniques. State-of-the-art microfluidic bioanalytical devices already claim their place in most molecular biology laboratories. This review summarizes the recent developments in microchip electrophoresis methods of nucleic acids, particularly for rapid genotyping, that will most likely play a significant role in the future of clinical diagnostics.  相似文献   

3.
Microfabricated devices are poised to offer inexpensive self-contained alternatives to conventional benchtop-scale laboratory equipment for performing a variety of important DNA analysis assays. In order to realize the dramatic cost savings possible through photolithographic fabrication techniques, these devices must occupy an extremely compact footprint on the silicon wafer. This requirement implies that electrophoretic separations must be performed over ultrashort distances. Employing cross-linked polyacrylamide gels in place of conventional uncross-linked sieving media offers a convenient strategy to achieve this goal. In this paper, we show how the increased resolving power offered by cross-linked polyacrylamide gels, along with improved sample injection techniques, can be exploited to enhance separation performance in microscale systems. We use these techniques to perform high-resolution gel electrophoresis of single-stranded DNA fragments in microfabricated devices over separation distances of 1.5 cm or less. The results presented here are in agreement with theoretical predictions and suggest that it is possible to perform DNA sequencing on compact microchips. More importantly, the separation performance demonstrated in this work is already more than adequate to perform a number of important genomic assays imposing less stringent resolution requirements than sequencing. Successfully adapting even a few of these assays to the microdevice format has the potential to provide a new generation of inexpensive and portable devices suitable for direct end-user applications.  相似文献   

4.
Xu F  Jabasini M  Baba Y 《Electrophoresis》2002,23(20):3608-3614
Low-viscosity polymer solutions have potential for double-stranded (ds) DNA separations in micrototal analysis systems (micro-TAS). In this paper, we report dilute, low-viscosity hydroxypropylmethylcellulose-50 (HPMC-50, 11.5 kDa) solutions containing polyhydroxy additives as separation media. Predominant operational variables, such as applied electric field strength, fluorescent intercalator (YOPro-1) concentration, polymer concentration, and additive concentration, are thoroughly investigated. Fast (within 170 s) and excellent separation of DNA restriction fragments ranging in size from 72 to 1353 base pairs (bp) is achieved in a 30 mm length channel of polymethylmethacrylate (PMMA) microchips at an electric field strength of 300 V/cm, by introducing 8% mannitol, 8% glucose or 10% glycerol additives into a 2% HPMC-50/1 x Tris-borate-EDTA (TBE) solution. The low-viscosity (40 cP) matrix formulation provides both coating of the microchannels and separation of DNA in one step. The performance in the solution surpasses that in highly concentrated HPMC-50 solution. In addition, separation using 1xTris-EDTA buffer in the 2% HPMC-50 matrix containing polyhydroxy additives also exhibits a notably increased performance. This is presumably due to formation of hydrogen-bonding interactions of polyhydroxy additives with HPMC-50 matrix and DNA so as to increase the coupling interactions between matrix and DNA molecules during electrophoresis. The result reflects that boric acid is not a prerequisite in polyhydroxy-enhanced HPMC-50 solution for separation.  相似文献   

5.
Guttman A  Rónai Z 《Electrophoresis》2000,21(18):3952-3964
Emerging need for large-scale, high-resolution analysis of biopolymers, such as DNA sequencing polymerase chain reaction, (PCR) product sizing, single nucleotide polymorphism (SNP) hunting and analysis of protein molecules necessitated the development of automated and high-throughput gel electrophoresis based methods enabling rapid, high-performance separations in a wide molecular weight range. Scaling down electric field mediated separation processes supports higher throughput due to the applicability of higher voltages, thus speeding up analysis time. Indeed, efforts in miniaturization resulted in faster, easier, less costly and more convenient analyses, fulfilling the needs of the emerging biotechnology industry for microscale and massively parallel assays. The two primary approaches in miniaturizing electrophoresis dimensions are the capillary and microslab formats. This latter one evolved towards ultrathin-layer gel electrophoresis which is, except from the thickness of the separation platform, slightly in the upper side of the scale, resulting in considerably easier handling. Ultrathin-layer gel electrophoresis combines the advantages of conventional slab-gel electrophoresis (multilane format) and capillary gel electrophoresis (rapid, high-efficiency separations). It is readily automated, automatic versions of it have been extensively used for large-scale DNA sequencing in the Human Genome Project and more recently became popular in high throughput DNA fragment analysis. Ultrathin-layer techniques are the first step towards the wider use of electrophoresis microchips in perfecting a user-friendly interface between the user and the microdevice.  相似文献   

6.
Here, we demonstrate the potential for high-resolution electrophoretic separations of ssDNA-protein conjugates in borosilicate glass microfluidic chips, with no sieving media and excellent repeatability. Using polynucleotides of two different lengths conjugated to moderately cationic protein polymer drag-tags, we measured separation efficiency as a function of applied electric field. In excellent agreement with prior theoretical predictions of Slater et al., resolution is found to remain constant as applied field is increased up to 700 V/cm, the highest field we were able to apply. This remarkable result illustrates the fundamentally different physical limitations of free-solution conjugate electrophoresis (FSCE)-based DNA separations relative to matrix-based DNA electrophoresis. ssDNA separations in "gels" have always shown rapidly declining resolution as the field strength is increased; this is especially true for ssDNA > 400 bases in length. FSCE's ability to decouple DNA peak resolution from applied electric field suggests the future possibility of ultra-rapid FSCE sequencing on chips. We investigated sources of peak broadening for FSCE separations on borosilicate glass microchips, using six different protein polymer drag-tags. For drag-tags with four or more positive charges, electrostatic and adsorptive interactions with poly(N-hydroxyethylacrylamide)-coated microchannel walls led to appreciable band-broadening, while much sharper peaks were seen for bioconjugates with nearly charge-neutral protein drag-tags.  相似文献   

7.
Sun M  Lin JS  Barron AE 《Electrophoresis》2011,32(22):3233-3240
Double-stranded (ds) DNA fragments over a wide size range were successfully separated in blended polymer matrices by microfluidic chip electrophoresis. Novel blended polymer matrices composed of two types of polymers with three different molar masses were developed to provide improved separations of large dsDNA without negatively impacting the separation of small dsDNA. Hydroxyethyl celluloses with average molar masses of ~27 kDa and ~1 MDa were blended with a second class of polymer, high-molar mass (~7 MDa) linear polyacrylamide. Fast and highly efficient separations of commercially available DNA ladders were achieved on a borosilicate glass microchip. A distinct separation of a 1-kb DNA extension ladder (200-40,000 bp) was completed in 2 min. An orthogonal design of experiments was used to optimize experimental parameters for DNA separations over a wide size range. We find that the two dominant factors are the applied electric field strength and the inclusion of a high concentration of low-molar mass polymer in the matrix solution. These two factors exerted different effects on the separations of small dsDNA fragments below 1 kbp, medium dsDNA fragments between 1 and 10 kbp, and large dsDNA fragments above 10 kbp.  相似文献   

8.
Microfabrication techniques have become increasingly popular in the development of the next generation of DNA analysis systems. While significant progress has been reported by many researchers, complete microfabricated integrated DNA analysis devices are still in the earliest stages of development. Most miniaturized analysis systems have incorporated noncross-linked polymer solutions as the separation medium of choice and the operation of these systems necessitates the use of high electric fields and long separation lengths. In this paper, we present two techniques that may help alleviate this problem and accelerate the development of the so-called 'lab-on-a-chip' systems. We present the use of photodefinable polyacrylamide gels as a sieving medium for DNA electrophoresis. These gels offer the significant advantages of faster curing times, locally controlled gel interface, and simpler handling over chemically polymerized gels. We also introduce an electrode-defined sample compaction and injection technique. This technique helps achieve sample compaction without migration into the gel and offers significant control over the size and application of the sample plug. The use of these technologies for double-stranded DNA separations in microfabricated separation systems is demonstrated.  相似文献   

9.
Roddy ES  Xu H  Ewing AG 《Electrophoresis》2004,25(2):229-242
A great deal of progress has been made toward the development of the micro total analysis system (micro-TAS) since its inception in 1990. A wide variety of applications, including genomics, proteomics and drug discovery, have prompted the development of analytical methods capable of very high throughput while maintaining low cost. The micro-TAS concept addresses both of these requirements. Electrophoresis has been a key element in the development of the micro-TAS. Most chemical and biochemical assays utilize a separation component at some point during analysis. Genomics, in particular, depends almost exclusively on electrophoresis for size-based separations of DNA. This review examines sample introduction into microfabricated electrophoretic devices, or chips, primarily for DNA analysis. Sample introduction is an important component of these systems and is an essential process for making chip electrophoresis a widely applicable analytical technique. Specific issues, such as automation, the delivery of large numbers of samples to microfabricated devices and injection of picoliter-sized sample plugs into a separation lanes on chips, are presented.  相似文献   

10.
A novel design of the detection zone in multicapillary arrays used for electrophoretic separation is presented. The use of a detection gap (DG), in which the reflective surfaces separating the channels of the array are eliminated, is proposed to improve the illumination and detection of the separated DNA fragments. The electric field compression in the DG is achieved by optimization of the gap geometry. The results of the computer simulation and experiment demonstrate no substantial band-broadening in the DG. We believe that the proposed method will be useful for application in the microfabricated devices.  相似文献   

11.
Smith EM  Xu H  Ewing AG 《Electrophoresis》2001,22(2):363-370
A novel method is presented for automated injection of DNA samples into microfabricated separation devices via capillary electrophoresis. A single capillary is used to electrokinetically inject discrete plugs of DNA into an array of separation lanes on a glass chip. A computer-controlled micromanipulator is used to automate this injection process and to repeat injections into five parallel lanes several times over the course of the experiment. After separation, labeled DNA samples are detected by laser-induced fluorescence. Five serial separations of 6-carboxyfluorescein (FAM)-labeled oligonucleotides in five parallel lanes are shown, resulting in the analysis of 25 samples in 25 min. It is estimated that approximately 550 separations of these same oligonucleotides could be performed in one hour by increasing the number of lanes to 37 and optimizing the rate of the manipulator movement. Capillary sample introduction into chips allows parallel separations to be continuously performed in serial, yielding high throughput and minimal need for operator intervention.  相似文献   

12.
Separating DNA sequencing fragments without a sieving matrix.   总被引:1,自引:0,他引:1  
The possibility of separating appropriately labeled DNA fragments using free-flow capillary electrophoresis was predicted a few years ago based on simple theoretical arguments. Free-flow separation of double-stranded DNA (dsDNA) fragments in the 100-1000 base range was later demonstrated using a streptavidin label. In this article, we now report that end-labeled free-flow electrophoresis (ELFSE) can also be used to sequence single-stranded DNA (ssDNA). The first 100 bases of a DNA sequencing reaction were read without any sieving matrix when fractionated streptavidin was added to the 5'-end of the ssDNA fragments. These separations required only 18 min and did not require coated capillaries. An analysis of the results indicates that sample injection, analyte-wall interactions and thermal diffusion are the limiting factors at this time. Extrapolating from our data, we predict that several hundred bases could be sequenced in less than 30 min with the proper conditions. ELFSE thus offers an attractive potential alternative to polymer solutions for DNA sequencing in capillaries and microchips.  相似文献   

13.
We demonstrate here the power and flexibility of free‐solution conjugate electrophoresis (FSCE) as a method of separating DNA fragments by electrophoresis with no sieving polymer network. Previous work introduced the coupling of FSCE with ligase detection reaction (LDR) to detect point mutations, even at low abundance compared to the wild‐type DNA. Here, four large drag‐tags are used to achieve free‐solution electrophoretic separation of 19 LDR products ranging in size from 42 to 66 nt that correspond to mutations in the K‐ras oncogene. LDR‐FSCE enabled electrophoretic resolution of these 19 LDR‐FSCE products by CE in 13.5 min (E = 310 V/cm) and by microchip electrophoresis in 140 s (E = 350 V/cm). The power of FSCE is demonstrated in the unique characteristic of free‐solution separations where the separation resolution is constant no matter the electric field strength. By microchip electrophoresis, the electric field was increased to the maximum of the power supply (E = 700 V/cm), and the 19 LDR‐FSCE products were separated in less than 70 s with almost identical resolution to the separation at E = 350 V/cm. These results will aid the goal of screening K‐ras mutations on integrated “sample‐in/answer‐out” devices with amplification, LDR, and detection all on one platform.  相似文献   

14.
We have developed a novel high-resolution separation technique of DNA fragments in a heterogeneous combination of a sample buffer and a separation buffer. The use of a heterogeneous buffer combination is a simple method for on-line concentration of DNA fragments, in which a sample buffer is simply exchanged with one including taurine anions. The mobility of taurine anions, co-ions for DNA, is lower than the that of acetate anions in a separation buffer. The difference in the mobility invokes transient isotachophoresis. The current technique allows DNA fragments to be effectively concentrated and the separation length of microchips to be shorter than that of conventional ones by a factor of three without deterioration in separation resolution and any modification of a chip design. Fragments of 100-bp DNA ladders (100-1000 bp) were separated with high resolution (0.72-10.7) within 60 s with a 10 mm separation length on a polymethyl methacrylate chip. Furthermore, fragments of 10-bp DNA ladders (10-330 bp) were separated with high resolution (0.69-2.00) with a 10 mm separation length within 50 s without band broadening. The current achievements will make it possible to fabricate compact devices for microchip electrophoresis.  相似文献   

15.
Chiral separations of fluorescamine-labeled amino acids are characterized and optimized on a microfabricated capillary electrophoresis (CE) device. A standard mixture of acidic and neutral amino acids is labeled with fluorescamine in less than 5 min and the hydroxypropyl-beta-cyclodextrin (HPbetaCD) concentration, temperature, and pH are optimized (15 mM HPbetaCD, 6 degrees C, pH < 9) to achieve high-quality and low background chiral separations in less than 200 s. All four stereoisomers formed in the labeling reaction of the chiral dye with the chiral amino acids are typically resolved. At pH > 9, isomerization of the dye chiral center is observed that occurs on the time scale of the chip separation. Typical limits of detection are approximately 50 nM. These results demonstrate the feasibility of combining fluorescamine labeling of amino acids with microfabricated CE devices to develop low-volume, high-sensitivity apparatus and methods for extraterrestrial exploration.  相似文献   

16.
The retention of different physical forms of DNA by an electric field in a chromatography system was studied. We were able to effectively separate the supercoiled and the open circular forms of plasmid DNA using this type of electrochromatography system. Chromatography columns were packed with porous beads, and an axial electric field was applied so that convective buffer flow opposed the direction of electrophoresis of the DNA. A model system composed of approximately equal amounts of the super-coiled and open circular forms of the plasmid pBR 322 (4322 base pairs) was used to test the separation. Chromatography beads (agarose-based) with different porosities were used to determine the effect of the stationary phase on the separation. The porous media did not have a major effect on the separation, but the best separations were obtained using porous chromatography media made with the highest agarose concentration (10% agarose). Selective elution of plasmid DNA with different forms was obtained by either increasing the flow rates or decreasing the electric field strength (by steps or a gradient). In all the separations, the more compact supercoiled form of the plasmid was retained less strongly than either the open circular form (nicked) or the linear form. High molecular weight host genomic DNA was more strongly retained than the plasmid DNA. Increasing the ionic strength of the buffer improved resolution and capacity. The capacity of the separation was determined by injecting increasing amounts of plasmid DNA. Satisfactory separation was obtained at sample loading of up to 360 microg of total DNA on a column with dimensions of 2.5 by 11 cm (bed volume of 54 mL). The retention of DNA depends upon a counter-current flow of electrophoresis and convective flow and could be regarded as a type of field flow fractionation. The retention of the DNA by the electric field and flow is discussed in relation to the diffusion coefficients of the DNA.  相似文献   

17.
B. Mile 《Chromatographia》2005,62(1-2):3-9
Chromatographic separation techniques are now widely used to examine the material evidence associated with a crime. Four areas are considered. Analysis of drugs of abuse by GC, GC-MS and GC-FTIR; HPLC; chiral chromatography; capillary electrophoresis (CE) and capillary electrochromatography (CEC); solid-phase microextraction (SPME). The quantitative detection of adulterants and trace pesticides in foods using supercritical fluid extraction (SFE). DNA profiling by separation of fragments by gel and capillary electrophoresis and fluorescence detection. Future developments in automation and miniaturisation and the design of microchips and micro-electrode devices allowing complete analysis in 8 μL cells.  相似文献   

18.
This study reports improved pulsed field capillary electrophoresis (PFCE) for separation of large DNA ladders. Important analytical conditions, including gel polymer concentration, ratio of forward to backward pulse duration, and separation potential, were investigated for their effects on the separation performance of DNA ranging in size from 0.1 to 10.0 kilo base pairs (kbp). Results show that DNA fragments from 0.1 to 8.0 kbp can be resolved with high resolution, simultaneously, in a short time. The ratio of forward to backward pulse duration affects the separation performance for DNA fragments greater than 1.5 kbp, and 3 or 4 is the optimum value of the ratio for separation of DNA up to 10 kbp. Furthermore, the separations that were obtained with 74–19,329 bp λ-DNA restriction fragments clearly demonstrate a dramatic improvement in the separation time and resolution over the conventionally used square-wave PFCE. The inversion field capillary electrophoresis reported here may help enable future DNA analysis studies to be performed quickly and effectively.  相似文献   

19.
Planar microfluidic devices have emerged as effective tools for the electrophoretic separation of a variety of different DNA inputs. The advancement of this miniaturized platform was inspired initially by demands placed on electrophoretic performance metrics by the human genome project and has provided a viable alternative to slab gel and even capillary formats due to its ability to offer high resolution separations of nucleic acid materials in a fraction of the time associated with its predecessors, consumption of substantially less sample and reagents while maintaining the ability to perform many separations in parallel for realizing ultra-high throughputs. Another compelling advantage of this separation platform is that it offers the potential for integrating front-end sample preprocessing steps onto the separation device eliminating the need for manual sample handling. This review aims to compile a recent survey of various electrophoretic separations using either glass or polymer-based microchips in the areas of genotyping and DNA sequencing as well as those involving the growing field of DNA-based forensics.  相似文献   

20.
The laser print, cut, and laminate (PCL) method for microfluidic device fabrication can be leveraged for rapid and inexpensive prototyping of electrophoretic microchips useful for optimizing separation conditions. The rapid prototyping capability allows the evaluation of fluidic architecture, applied fields, reagent concentrations, and sieving matrix, all within the context of using fluorescence-compatible substrates. Cyclic olefin copolymer and toner-coated polyethylene terephthalate (tPeT) were utilized with the PCL technique and bonding methods optimized to improve device durability during electrophoresis. A series of separation channel designs and centrifugation conditions that provided successful loading of sieving polymer in less than 3 min was described. Separation of a 400-base DNA sizing ladder provided calculated base resolution between 3 and 4 bases, a greater than 18-fold improvement over separations on similar substrates. Finally, the accuracy and precision capabilities of these devices were demonstrated by separating and sizing DNA fragments of 147 and 167 bases as 148.62 ± 2 and 166.48 ± 3 bases, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号