首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 125 毫秒
1.
The potentiometric response characteristics of cesium ion selective PVC membrane electrode employing calix[4]crown ether-ester as an ionophore were investigated. The electrode exhibit a good response for cesium ion over wide concentration range of 5.0x10(-6)-1.0x10(-1) M with a Nernstian slope of 59 mV per decade. The detection limit of electrode is 5.0x10(-6) M. The electrode was found to have selectivity for cesium ion over alkali, alkaline and transition metals. The response time of the electrode is less than 20 s and can be used for more than 4 months without observing any divergence in potentiometric response. The electrode response was stable over wide pH range.  相似文献   

2.
Cadmium ion-selective electrode based on tetrathia-12-crown-4   总被引:1,自引:0,他引:1  
Shamsipur M  Mashhadizadeh MH 《Talanta》2001,53(5):1065-1071
A new polyvinylchloride membrane sensor for Cd(2+) ions based on tetrathia-12-crown-4 as an ionophore was prepared. The sensor exhibits a Nernstian response for cadmium ions over a wide concentration range (4.0 x 10(-7) to 1.0 x 10(-1) M) with a slope of 29+/-1 mV decade(-1). The limit of detection is 1.0 x 10(-7) M (0.01 ppm). It has a fast response time of <10 s and can be used for at least 6 weeks without any divergence in potential. The electrode can be used in the pH range from 2.5 to 8.5. The proposed sensor shows fairly good discriminating ability towards Cd(2+) ion in comparison with some alkali, alkaline earth, transition and heavy metal ions. It was successfully applied for the direct determination of Cd(2+) in solution and, as an indicator electrode, in potentiometric titration of cadmium ions.  相似文献   

3.
A new carbon paste electrode (CPE) for the determination of iodide ion based on a cetyltrimethylammonium iodide (CTMAI) ion pair as an electroactive material is described. The electrode shows a linear response for iodide ion over the concentration range of 4 x 10(-5) M to 1 x 10(-1) M with a lower detection limit of 4 x 10(-5) M at 25 degrees C. The electrode has a Nemstian slope of -55.0 +/- 0.4 mV/decade and a fast potential response of 45 s, which is almost constant over a pH range of 5.0 - 9.0. Selectivity coefficient data of the CTMAI-CPE for some common ions show negligible interference, and the electrode has high selectivity towards the iodide ion. An average recovery of 101.83% with a relative standard deviation of 1.53% has been achieved for the determination of iodide in Flaxedil (gallamine triethiodide) ampoules, a muscle relaxant drug. The electrode has been examined for the determination of iodide in saline water; the results were found to compare favorably with those obtained using Metrohm iodide ISE. The electrode has been utilized as an end-point indicator electrode for the determination of Hg(II) and phenylmercury(I) in their aqueous solutions using potentiometric titration with a potassium iodide standard solution.  相似文献   

4.
A novel membrane coated platinum-wire electrode (MCPWE) based on N,N'-bis(2-thienylmethylene)-1,2-diaminobenzene (BTMD) for highly selective determination of Ag+ ion has been developed. The influences of membrane composition and pH on the potentiometric responses of electrode were investigated. The potentiometric responses are independent of the pH of the test solution in the range of 5.0 - 9.0. The electrode shows a linear response for Ag+ ion over the concentration range of 1.0 x 10(-60 to 1.0 x 10(-1) M with a lower detection limit of 6.0 x 10(-7) M. The electrode possesses a Nernstian slope of 59.7 mV decade(-1) and a fast response time of < or = 17 s and can be used for at least 2 months without any observable deviation. The proposed electrode displayed very good selectivity for Ag+ ion with respect to NH4+ and alkali, alkaline earth and some common transition metal ions. The practical utility of the electrode has been demonstrated by its use as the indicator electrode in the potentiometric titration of an AgNO3 solution with a NaI solution and in determination of the silver content of a developed radiological film.  相似文献   

5.
A new PVC membrane ion selective electrode which is highly selective towards Ni(II) ions was constructed using a Schiff base containing a binaphthyl moiety as the ionophore. The sensor exhibited a good Nernstian response for nickel ions over the concentration range 1.0x10(-1)-5.0x10(-6) M with a lower limit of detection of 1.3x10(-6) M. It has a fast response time and can be used for a period of 4 months with a good reproducibility. The sensor is suitable for use in aqueous solutions in a wide pH range of 3.6-7.4 and works satisfactorily in the presence of 25% (v/v) methanol or ethanol. The sensor shows high selectivity to nickel ions over a wide variety of cations. It has been successfully used as an indicator electrode in the potentiometric titration of nickel ions against EDTA and also for the direct determination of nickel content in real samples: effluent samples, chocolates and hydrogenated oils.  相似文献   

6.
A new PVC membrane mercury(II) ion electrode based on N,N-dimethylformamide-salicylacylhydrazone (DMFAS) as an ionophore is described, which shows excellent potentiometric response characteristics and displays a linear log[Hg(2+)] versus EMF response over a wide concentration range between 6.2 x 10(-7) and 8.0 x 10(-2) M with a Nerstian slope of 29.6 mV per decade and a detection limit of 5.0 x 10(-7) M. The response time for the electrode is less than 30 s and the electrode can be used for more than 2 months with less than a 2 mV observed divergence in a potentials. The proposed electrode exhibits very good selectivity for mercury(II) ions over many cations in a wide pH range (pH 1 - 4). The electrode was also applied to the determination of a mercury(II) ion in vegetables and in Azolla filiculoides.  相似文献   

7.
A new heterogeneous precipitate of an organic-inorganic composite cation-exchanger poly-o-toluidine Zr(IV) phosphate was utilized for the preparation of a Hg(II) ion-sensitive membrane electrode for the determination of Hg(II) ions in real aqueous as well as in real samples. The electrode showed good potentiometric response characteristics, and displayed a linear log[Hg(2+)] versus EMF response over a wide concentration range of 1 x 10(-1) - 1 x 10(-6) M with a Nernstian slope of 30 mV per decade change in concentration with a detection limit of 1 x 10(-6). The membrane electrode showed a very fast response time of 5 s and could be operated well in the pH range 2 - 8. The selectivity coefficients were determined by the mixed-solution method, and revealed that the electrode was selective in the presence of interfering cations; however most of these did not show significant interference in the concentration range of 1 x 10(-1) - 1 x 10(-4) M. The lifetime of the membrane electrode was observed to be 120 days. The analytical utility of this electrode was established by employing it as an indicator electrode in the potentiometric titrations of Hg(2+) ions from a synthetic mixture as well as drain water.  相似文献   

8.
For preparing a berberine-sensitive electrode, 5,10,15,20-tetrakis[2-(2,3,4,6-tetraacetyl-beta-D-glucopyranosyl)-1-O- phenyl]porphyrin (T(o-glu)PPH2) was synthesized from the reaction of pyrrole with ortho-acetylglycosylated benzaldehyde by Lindsay's method. The electrode based on T(o-glu)PPH2 with an optimized membrane composition exhibits Nernstian response to berberine in the concentration range 2.4 x 10(-7)-5.0 x 10(-3) mol L-1, with a pH range from 3.9 to 10.2, and a fast response time of 30 s. The electrode shows fair selectivity towards berberine with respect to common co-existing species. T(o-glu)PPH2 shows better potentiometric response characteristics comparing to chloro[5,10,15,20-tetrakis[2-(2,3,4,6-tetraacetyl-beta-D- glucopyranosyl)-1-O-phenyl]-porphinato]-manganese (MnT(o-glu)PPCl) and better selectivity towards berberine than tetraphenylporphyrin (TPPH2). The effect of the composition of the electrode membrane has been studied and the experimental conditions optimized. The contents of berberine in pharmaceutical tablets were determined by direct potentiometry and the results agreed with values obtained by the pharmacopoeia method.  相似文献   

9.
A sulfate ion-selective PVC membrane sensor based on 4-(4-bromophenyl)-2,6-diphenylpyrilium perchlorate (BDPP) as a novel sensing material is successfully developed. The electrode shows a good selectivity for sulfate ion with respect to common organic and inorganic anions. The sensor exhibits a good linear response with slope of -28.9+/-0.5 mV per decade over the concentration range of 1.0x10(-6)-1.0x10(-2) M, and a detection limit of 8.0x10(-7) M of SO(4)(2-) ions. The electrode response is independent of pH in the range of 4.0-9.0. The proposed sensor was applied as an indicator electrode in potentiometric titration of sulfate and barium ions, and to the determination of zinc in zinc sulfate tablets.  相似文献   

10.
Zhang XB  Guo CC  Xu JB  Shen GL  Yu RQ 《The Analyst》2000,125(5):867-870
Lanthanide porphyrin complexes synthesized by a solid state method were used to prepare a novel ethacrynic acid (EA) sensor. The sensor, based on pentane-2,4-dionato(meso-tetraphenylporphinato)terbium [TbTPP(acac)] with an optimized membrane composition, exhibits a Nernstian response to EA- ion in the concentration range 7.4 x 10(-6)-1.0 x 10(-1) mol l-1 with a pH range from 3.2 to 6.8 and a fast response time of 30 s. The electrode shows improved selectivity towards EA- ion with respect to common co-existing ions compared with the previously reported EA sensor. As electroactive materials, lanthanide porphyrin complexes show better potentiometric response characteristics than copper porphyrin complexes. The effect of solvent mediators and lipophilic ion additives was studied and the experimental conditions were optimized. The electrode was applied to the determination of EA in human urine samples with satisfactory results.  相似文献   

11.
Abbaspour A  Izadyar A 《Talanta》2001,53(5):1009-1013
A PVC-based membrane of 4-dimethylaminoazobenzene reveals a Nernstian potentiometric response (with slope of 19.5+/-0.6 mV/decade and a correlation coefficient of 0.999) for Cr(III) over a wide concentration range (1.66 x 10(-6)-1.0 x10(-2) mol dm(-3)). The potential of this electrode is independent of pH in the range of 3.0-5.5. It has a fast response time of about 10 s and was used for a period of 3 months with good reproducibility. The detection limits of this membrane electrode was 8 x 10(-7) M. the proposed electrode has been used as an indicator electrode in the potentiometric titration of Cr(III) with EDTA. This sensor exhibits a very good selectivities for Cr(III) over a wide variety of metal ions.  相似文献   

12.
《Analytical letters》2012,45(11):2201-2215
ABSTRACT

DP+ ion-selective PVC membrane electrode based on 2,3,11,12-dibenzo-5,9-diaza-4,9(10)-cis-diimino-1,13-dioxacyclopentadecane as a novel macrocyclic diimine crown ether is proposed. o-Nitrophenyl octyl ether as plasticizer and potassium tetrakis(4-chlorophenyl)borate as lipophilic salt were used. The electrode exhibits a Nernstian response for 1.0 x 10?2-1.0 x 10?6 mol 1?1 DPCl with a slope of 58 mVdecade?1. The detection limit is 2.5 x 10?7 mol 1?1. The electrode response was stable over a wide pH range (3-11). The lifetime of the electrode was about 2 months. The electrode shows a high selectivity towards inorganic cations. Among the organic cations tested, only hexadecyltrimethylammonium ion interferes. The electrode was suitable for determining the critical micelle concentration and as an end-point detector in the potentiometric titration of the cationic surfactants.  相似文献   

13.
A silver ion-selective electrode was prepared with a polymeric membrane incorporating 2,6-bis-methylsulfanyl-[1,3,5]thiadiazine-4-thione as an ionophore, tri-n-butylphosphate (TBP) as a plasticizer and sodium tetraphenylborate (NaTPB) as an additive. The electrode exhibited a near-Nernstian response of 52 mV/decade over a wide linear concentration range of 1.0 x 10(-5) - 1.0 x 10(-1) M with a lower detection limit of 9.77 x 10(-6) M. The electrode exhibited excellent selectivity for silver ion over many of the alkali, alkaline-earth and transition metal ions. The electrode worked well over a wide pH range of 1.77 - 7.13. The response time of the electrode was less than 20 s. The sensor can be applied as indicator electrode for the potentiometric titration of Ag+ ions with Cl- ions.  相似文献   

14.
A highly selective poly(vinyl chloride) (PVC) membrane electrode based on an N,N'-ethylene-bis(4-methyl-salicylidineiminato) nickel(II) [Ni(EBMSI)] complex as a carrier for a thiocyanate-selective electrode is reported. The influences of the membrane composition, pH and possible interfering anions were investigated based on the response properties of the electrode. The electrode exhibited a good Nernstian slope of -58.9 +/- 0.7 mV decade(-1), over a wide pH range of 3.5 - 8.5 and a linear range of 1.0 x 10(-6) - 1.0 x 10(-1) M for thiocyanate. The detection limit of electrode was 3.1 x 10(-7) M SCN(-). The selectivity coefficients determined by a fixed interference method (FIM) indicate that a good discriminating ability towards the SCN- ion compared to other anions. The proposed sensor had a fast response time of about 5 - 15 s and could be used for at least 3 months without any considerable divergence in the potential. It was applied as an indicator electrode in the titration of thiocyanate with Ag+ and in the potentiometric determination of thiocyanate in saliva and urine samples.  相似文献   

15.
A new PVC membrane electrode for the triiodide ion based on a charge-transfer complex of iodine with 7,16-dibenzyl-1,4,10,13-tetraoxa-7,16-diazacyclooctadecane as a membrane carrier was prepared. The electrode exhibits a Nernstian response for triiodide ions over a wide concentration range (1.0 x 10(-1)-1.0 x 10(-5) M) with a slope of 59.3 +/- 0.9 mV decade(-1) and a detection limit of 6.3 x 10(-6) M. It has a response time of 30 s and can be used for at least 3 months without any divergence in the potential. The potentiometric response is independent of the pH, in the pH range 1.6 - 10.0. The proposed electrode has shown very high selectivity for the triiodide ion over a wide variety of other anions. This electrode was successfully applied as an indicator electrode in the potentiometric titration of ascorbic acid and hydroquinone from pharmaceutical preparations as well as ascorbic acid in orange juice and dissolved O2 in tap water.  相似文献   

16.
A highly La(III) ion-selective PVC membrane sensor based on N'-(1-pyridin-2-ylmethylene)-2-furohydrazide (NPYFH) as an excellent sensing material was successfully developed. The electrode shows a good selectivity for La(III) ion with respect to most common cations including alkali, alkaline earth, transition and heavy metal ions. The proposed sensor exhibits a wide linear response with slope of 19.2 +/- 0.6 mV per decade over the concentration range of 1.0 x 10(-6) - 1.0 x 10(-1) M, and a detection limit of 7.0 x 10(-7) M of La(III) ions. The sensor response is independent of pH in the range of 3.5-10.0. The proposed electrode was applied as an indicator electrode in potentiometric titration of La(III) ion with EDTA.  相似文献   

17.
Abbas MN  Mostafa GA  Homoda AM 《Talanta》2000,53(2):425-432
A potentiometric method is described for the determination of cetylpyridinium (CP) cation using a polyvinyl chloride powder (PVC) membrane sensor based on CP-iodomercurate ion pair as an electroactive material. The sensor shows a linear response for CP ion over the concentration range of 2x10(-6)-1x10(-3) M at 25 degrees C. The electrode posses a sub-Nernstian slope of 29.0+/-0.4 mV decade(-1), which has been thoroughly discussed.The electrode shows a fast potential response of approximately 50 s, which is almost constant over a pH range of 3.0-6.0. Selectivity coefficient data for some common ions show negligible interference, however, cetyltrimethylammonium bromide (CTMAB) interferes significantly. An average recovery of 98.8% for CP with an average relative standard deviation (R.S.D.) of 1.2% has been achieved. The determination of CPC in Ezafluor mouth wash gave result that compare favorably with those obtained by the British Pharmacopoeia method. The CP electrode has been utilized as an end point indicator electrode in potentiometric titration of some anions, and applied for the determination of anionic surfactants in some commercial detergents and waste water.  相似文献   

18.
Kudoh M  Kataoka M  Kambara T 《Talanta》1980,27(6):495-498
The construction of a liquid-membrane type periodate ion-selective electrode and its application to the potentiometric titration of alpha-diols and alpha-amino-alcohols are described. The ion-pair of periodate anion with Capriquat (tri-n-octylmethylammonium chloride), is easily extracted into nitrobenzene, and this extract is employed as a liquid ion-exchange membrane. The calibration curve shows Nernstian response towards periodate ion over the concentration range from 10(-1)M to 10(-7)M with a slope of 60 mV/pIO(-)(4). Selectivity coefficients with respect to various ions were evaluated. The electrode potential was independent of pH in the range 2.5-7.5. Some alpha-diols and monoethanolamine were successfully titrated potentiometrically with the aid of the present electrode.  相似文献   

19.
The potentiometric anion selectivity of two polymer membrane based electrodes (I and II) formulated with two new cyclopalladated amine complexes as the active components are examined. The electrodes exhibit a non-Hofmeister selectivity pattern with a significantly enhanced response towards thiocyanate, iodide and nitrite. The graph potential versus log c is linear over the concentration range 10(-6)-6x10(-2) M thiocyanate with electrode I and 10(-6)-10(-3) M with electrode II; 10(-5)-10(-2) M iodide with electrode I and 10(-3)-6x10(-2) M with electrode II; and 10(-3)-6x10(-2) M nitrite with both electrodes. The influence of the plasticizer and pH are studied. The potentiometric selectivity coefficients for I, II and blank membrane electrodes are reported. The selective interaction between Pd(II) thiocyanate, iodide and nitrite is postulated to be the reason for its higher response.  相似文献   

20.
Abbas MN  Mostafa GA  Homoda AM 《Talanta》2001,55(3):647-656
A novel PVC membrane electrode selective for the determination of pentachlorophenolate (PCP) ion based on 2,3,5-triphenyl-2H-tetrazolium (TPT) pentachlorophenolate ion pair as an electroactive material is described. The electrode shows a linear response for PCP ion over the concentration range of 6x10(-5) to 1x10(-2) M with lower detection limit of 4x10(-5) M at 25 degrees C. The electrode posses a Nernstian slope of -55.0+/-1.0 mV/decade and a fast potential response of 45 s, which is almost constant over a pH range of 5.5-10.5. Selectivity coefficient data for some common ions show negligible interference, however, 2,4,6-trichlorophenolate and cetylpyridinium ions interfere. An average recovery of 96.2% with relative standard deviation of 2.3% has been achieved for the determination of 75.0 ppm PCP in wastewater samples. The determination of PCP in soil and wood samples gave results that compare favorably with those obtained by gas chromatography. The electrode has been utilized as an end point indicator electrode for the determination of PCP using potentiometric titration.  相似文献   