首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A selective and sensitive high-performance liquid chromatographic method with coulometric detection is described for the quantitation of buspirone and its active metabolite, 1-(2-pyrimidinyl)piperazine, in plasma samples of mice treated orally with buspirone (10 mg/kg body weight). The analytes are extracted with a carboxylic acid solid-phase extraction column before chromatography. A dual-electrode electrochemical detector is used. The limit of detection is 50 pg for buspirone and 35 pg for 1-(2-pyrimidinyl)piperazine.  相似文献   

2.
A sensitive (50 pg/ml) method for the determination of heptylphysostigmine in human plasma is described. The procedure is based on liquid-liquid extraction of the drug from buffered plasma, and analysis of the concentrated organic extract using high-performance liquid chromatography on a silica column, under normal-phase chromatographic conditions, with fluorescence detection. Physostigmine was used as an internal standard. The assay has been fully validated in the concentration range 50-2000 pg/ml and utilized for the analysis of clinical samples from subjects dosed with heptylphysostigmine.  相似文献   

3.
A method is described for determination of minoxidil in human plasma using high-performance liquid chromatography with electrochemical detection. The method is specific and sensitive (500 pg/ml), however, minoxidil and minoxidil sulfate cannot be differentiated due to rapid autohydrolysis of minoxidil sulfate to minoxidil. The extraction procedure employs a C18 preparatory column to remove endogenous plasma constituents which would interfere with the assays. The calibration curves are linear for concentrations from 500 pg to 10 ng/ml. Within-day and between-day reproducibility are satisfactory with coefficient of variation less than 5.7% for all concentrations. Sample recovery from extraction is consistent at 45 to 55% at low and high concentrations, respectively. A pharmacokinetic study in a hypertensive volunteer receiving two different oral doses of minoxidil (1.25 and 2.5 mg) on different occasions demonstrates the utility of the method.  相似文献   

4.
Determination of quercetin in human plasma was carried out by semi-micro high-performance liquid chromatography with electrochemical detection. Peak heights for quercetin were found to be linearly related to the amount of each quercetin injected from 1.5 to 750 pg. The detection limit (signal-noise ratio, S/N = 3) of the present method for quercetin was 0.3 pg. Glucuronic and sulfate forms of quercetin in plasma were hydrolyzed enzymatically using beta-glucuronidase and sulfatase, respectively. Quercetin in plasma and the hydrolyzed solution were extracted with ethyl acetate and determined by the present method. The time courses of concentrations of quercetin in human plasma showed maxima at 1-1.5 h after ingestion of 340 mL of commercial canned green tea.  相似文献   

5.
A highly sensitive method for measuring endogenous vitamin K1, menaquinone-4 (which is one of the K2 vitamins) and vitamin K1 2,3-epoxide in human plasma was developed, based on high-performance liquid chromatography with coulometric reduction and fluorimetric detection, following extraction from plasma and purification on a Sep-Pak silica cartridge. The detection limits of vitamin K1, menaquinone-4 and vitamin K1 2,3-epoxide were 5, 5 and 8 pg per injection for the standard substances and 30, 30 and 50 pg/ml in human plasma, respectively.  相似文献   

6.
A method for the determination of nanogram amounts of delta 9-tetrahydrocannabinol (THC) in plasma and serum is described. THC was quantitatively isolated by solid-phase extraction after addition of an aqueous solution of urea and methanol to the sample. The extracts were analysed by high-performance liquid chromatography with electrochemical detection in the oxidizing mode. The detection limit of THC is ca. 100 pg for a signal-to-noise ratio of 3. With this method, levels of 2 ng/ml of THC in plasma can be measured.  相似文献   

7.
We report a reliable fluorimetric assay for the simultaneous determination of norepinephrine, epinephrine, dopamine and dobutamine in human plasma and urine, based on liquid-liquid extraction and derivatization with the fluorogenic agent 1,2-diphenylethylenediamine prior to chromatography. The method is sensitive (detection limit 0.3-0.8 pg injected) and reproducible (coefficients of variation 1-10%), and shows good accuracy (93-98%). The method should also be used when one only wants to measure the concentrations of the natural catecholamines, in order to avoid interference by metabolites of dobutamine and by the late-eluting dobutamine itself.  相似文献   

8.
A liquid chromatographic method using dual-electrode detection has been developed for determination of physostigmine in biological fluids. The limit of detection is in the order of 25-50 pg mol-1 of plasma. A high sample throughput is obtained by a single solvent extraction step and autoinjection into the chromatograph. Data following oral doses of physostigmine are presented.  相似文献   

9.
The reversed-phase high-performance liquid chromatography with electrochemical detection was used to quantify plasma and urine levels of vinblastine, vincristine, vindesine and a metabolite of vinblastine, desacetylvinblastine. Sample clean-up consisted of solid-phase extraction with a Bond Elut CN column. The extracts were separated on a Hypersil ODS column. The mobile phase consisted of a mixture of methanol and 10 mM phosphate buffer (pH 7.0). The limit of sensitivity using electrochemical detection was 100 pg on-column for all compounds with a signal-to-noise ratio of 3. Quantification of the compounds in human plasma and urine was possible down to 1 ng/ml (ca. 1 pmol). Pharmacokinetic results show that the sensitivity of the method is adequate for drug monitoring in clinical research.  相似文献   

10.
A sensitive and reproducible method for the determination of lacidipine, a new potent antihypertensive dihydropyridine, is reported. The method involves solid-phase extraction, reversed-phase high-performance liquid chromatography and radioimmunoassay of the collected fraction. The assay provides a limit of detection of 20 pg/ml of plasma, allowing the determination of trough (24 h) plasma concentrations. The method is suitable for pharmacokinetic studies in man.  相似文献   

11.
Reversed-phase high-performance liquid chromatography (HPLC) is directly coupled to helium microwave-induced plasma mass spectrometry (He MIP-MS) for the element-selective detection of halogenated organic compounds. Absolute detection limits are approximately 50 pg Br for brominated compounds, 1 pg I for iodinated compounds, and 10 ng Cl for chlorinated compounds. The linear dynamic range for Br- and I-containing compounds is 3-4 orders of magnitude. However, the linear range for chlorinated species is severely limited by high background at m/z = 35. The relative standard deviation for repetitive injections is less than 10%. The helium microwave-induced plasma is operated at moderate powers (300-350 W) and with a total helium consumption of 6-8 L/min. The effect of organic solvents on the background mass spectrum is investigated.  相似文献   

12.
A liquid chromatographic method with electrochemical detection is described for measuring plasma 3-methoxy-4-hydroxymandelic acid (VMA). Plasma is deproteinized by gel filtration and VMA is extracted into ethyl acetate, which is evaporated. VMA is oxidized to vanillin, which is purified by toluene extraction and quantified by high-performance liquid chromatography. The recovery of VMA through the entire procedure is 52 +/- 10% (mean +/- S.D., n = 19). The plasma VMA concentration in healthy young volunteers varies between 4.39 and 14.6 ng/ml, a range that is in excellent agreement with data obtained with mass fragmentography.  相似文献   

13.
A highly sensitive and specific assay for the quantitation of prostaglandins (PGs) such as PGE1, PGE2, PGF1 alpha, PGF2 alpha, 6-keto-PGF1 alpha, and including thromboxane B2, is described. The method involves the addition of PGF1 alpha and PGE1 as the internal standards, extraction from whole blood and purification by silica gel column chromatography. Following conversion into the methoximes, purification by reversed-phase chromatography and esterification with panacyl bromide, samples are analysed by high-performance liquid chromatography with fluorimetric detection. The lower limit of detection of the eicosanoids 6-keto-PGF1 alpha, thromboxane B2 and PGF2 alpha in blood is ca. 50 pg/ml and that of PGE2 is 100 pg/ml. Assay linearity is demonstrated over a range from 60 pg to 60 ng of eicosanoid injected. The method allows simultaneous assessment of prostaglandins and thromboxane extracted from complex biological fluids at picogram levels.  相似文献   

14.
Clenbuterol (CBL) is a potent beta(2)-adrenoceptor agonist used for the management of respiratory disorders in the horse. The detection and quantification of CBL can pose a problem due to its potency, the relatively low dose administered to the horse, its slow clearance and low plasma concentrations. Thus, a sensitive method for the quantification and confirmation of CBL in racehorses is required to study its distribution and elimination. A sensitive and fast method was developed for quantification and confirmation of the presence of CBL in equine plasma, urine and tissue samples. The method involved liquid-liquid extraction (LLE), separation by liquid chromatography (LC) on a short cyano column, and pseudo multiple reaction monitoring (pseudo-MRM) by electrospray ionization quadrupole time-of-flight tandem mass spectrometry (ESI-QTOF-MS/MS). At very low concentrations (picograms of CBL/mL), LLE produced better extraction efficiency and calibration curves than solid-phase extraction (SPE). The operating parameters for electrospray QTOF and yield of the product ion in MRM were optimized to enhance sensitivity for the detection and quantification of CBL. The quantification range of the method was 0.013-10 ng of CBL/mL plasma, 0.05-20 ng/0.1 mL of urine, and 0.025-10 ng/g tissue. The detection limit of the method was 13 pg/mL of plasma, 50 pg/0.1 mL of urine, and 25 pg/g of tissue. The method was successfully applied to the analysis of CBL in plasma, urine and various tissue samples, and in pharmacokinetic (PK) studies of CBL in the horse. CBL was quantified for 96 h in plasma and 288 h in urine post-administration of CLB (1.6 micro g/kg, 2 x daily x 7 days). This method is useful for the detection and quantification of very low concentrations of CBL in urine, plasma and tissue samples.  相似文献   

15.
An extraction technique is described for vitamin K1 in medical foods, using accelerated solvent extraction (ASE) in conjunction with matrix solid-phase dispersion (MSPD). The medical food sample is treated as it would be with MSPD extraction, followed by ASE for a hands-free automated extraction. The vitamin K1 in the ASE extract is then quantitated by reversed-phase liquid chromatography with fluorescence detection. The chromatography specifications are identical to those in previous work that used MSPD only, with a limit of detection of 6.6 pg and a limit of quantitation of 22 pg on column. Recoveries, which were determined for an analyte-fortified zero control reference material for medical foods, averaged 97.6% (n = 25) for vitamin K1. The method provides a rapid, automatic, specific, and easily controlled assay for vitamin K1 in fortified medical foods with minimal solvent usage.  相似文献   

16.
Rapid methods are described for determination of flumequine (FLU) residues in muscle and plasma of farm-raised channel catfish (Ictalurus punctatus). FLU residues were extracted from tissues with an acidified methanol solution, and extracts were cleaned up on C18 solid-phase extraction cartridges. FLU concentrations were determined by liquid chromatography (LC) using a C18 analytical column and fluorescence detection (excitation, 325 nm; emission, 360 nm). Mean recoveries of FLU from fortified muscle were 87-94% at 5 levels ranging from 10 to 160 ppb (5 replicates per level). FLU recoveries from fortified plasma were 92-97% at 5 levels ranging from 20 to 320 ppb. Limits of detection (signal-to-noise ratio, 3:1) for the method as described were 3 and 6 ppb for muscle and plasma, respectively. Relative standard deviations (RSDs) for recoveries were < or = 12%. Live catfish were dosed with 14C-labeled or unlabeled FLU to generate incurred residues. Recoveries of 14C residues throughout extraction and cleanup were 90 and 94% for muscle and plasma, respectively. RSDs for incurred FLU at 2 levels in muscle and plasma ranged from 2 to 6%. The identity of FLU in incurred tissues was confirmed by LC/mass spectrometry.  相似文献   

17.
A sensitive method for the selective determination of nitroglycerin at concentrations down to 50 pg/ml in human plasma is described. After the addition to plasma of a known amount of butane-1,2,4-triol trinitrate as internal standard, both compounds are extracted into hexane. Nitroglycerin is then quantitated by capillary gas chromatography with electron-capture detection.  相似文献   

18.
Liquid chromatography–tandem mass spectrometry has become the preferred technology to measure unconjugated metanephrine and normetanephrine in plasma because of its high sensitivity and specificity over immunoassay and gas chromatography–mass spectrometry. In our earlier study, plasma metanephrines were extracted with offline ion-pairing solid-phase extraction and quantified by liquid chromatography–tandem mass spectrometry with porous graphitic carbon column based chromatography. In this study, we aim to automate the sample preparation with turbulent flow online extraction technology and maintain or improve the analytical performance previously achieved from the offline approach. The online extraction was done with a mixed-mode cation exchange turbulent flow chromatography column assisted with ion-pairing reagent and porous graphitic column was used for chromatographic separation. The total online extraction and analytical LC runtime was 12 min. This method was linear from 6.3 to 455.4 pg/mL for metanephrine; 12.6 to 954.5 pg/mL for normetanephrine with an accuracy of 80.6% to 93.5% and 80.9% to 101.7%, respectively. The lower limit of quantitation was 6.3 pg/mL for metanephrine and 12.6 pg/mL for normetanephrine. Inter-assay and intra-assay precision for metanephrine and normetanephrine at low and high concentration levels ranged from 2.0% to 10.5%. In conclusion, we have developed a fast and sensitive automated online turbulent flow extraction method for the quantitative analysis of plasma metanephrines. Ion-pairing reagent was necessary for the success of this method.  相似文献   

19.
A method for estimating progesterone in rat plasma using gas-liquid chromatography (GLC) with electron-capture detection is described. By means of a column chromatographic technique for the extraction of progesterone from plasma, it is possible to isolate the steroid in such a specific way that, contrary to previously published methods, no additional chromatographic purification and separation steps are needed prior to the final GLC analysis. As a derivative for electron-capture detection we used the 3,20-di-O-pentafluorobenzyloxime of progesterone. This derivative is superior to those used hitherto with regard to sensitivity and stability. The high overall recovery (mean value, 89.4%) makes this method especially convenient for research work when only little plasma is available, or when the concentration of progesterone is very low.  相似文献   

20.
An analytical method was developed for the quantitation of a candidate antileishmanial drug, 6-methoxy-8-(6-diethylaminohexylamino)-4-methylquinoline, dihydrochloride, in canine plasma. The assay utilized internal standard technique with a structural similar 8-aminoquinoline, 6-methoxy-8-(7-diethylaminoheptylamino)-4-methylquinoline, dihydrochloride, as the internal standard. The method employs a liquid-solid extraction procedure with prepackaged silica gel columns upon which the drug and internal standard are adsorbed, then selectively washed and eluted. Reversed-phase chromatography was then employed to analyze the extracted sample by means of oxidative electrochemical detection at +0.75 V. Good accuracy and precision were obtained over the range of concentration tested (10-1500 ng/ml plasma). Analyses of plasma samples from human volunteers given the drug demonstrate the method is also suitable for analysis of human plasma samples. The entire procedure is relatively simple and requires only 1 ml of plasma.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号