The aim of this work consisted on the implementation of sufficiently accurate and sensitive analytical procedure for the analysis of metal concentration in rainwater. Different sample preparation procedures were tested to achieve the required concentration prior to direct total reflection X-ray fluorescence (TXRF) analysis. TXRF and anodic stripping voltammetry (ASV) were compared in regard to achieved detection limits, precision and accuracy.  相似文献   

2.
The total reflection X-ray fluorescence (TXRF) method has been used for the analysis of various types of solid materials of biological, geological and environmental origin. The sample preparation step prior to TXRF measurements has been optimized for the various solid samples, including their decomposition by applying both a microwave oven and a PTFE bomb. Complete procedures for the optimized decomposition from the point of view of speed and completeness of digestion, as well as of the overall precision and accuracy are presented.  相似文献   

3.
An electrolytic separation and enrichment technique was developed for the determination of trace elements by total-reflection X-ray fluorescence spectroscopy (TXRF). The elements of interest are electrodeposited out of the sample solution onto a solid, polished disc of pure niobium which is used as sample carrier for the TXRF measurement. The electrochemical deposition leads to a high enrichment of the analytes and at the same time to a removal of the matrix. This results in substantially improved detection limits in the lower picogram per gram region. The deposited elements are directly measured by TXRF without any further sample preparation step. The homogeneous thin layer of the analytes is an ideal sample form for TXRF, because scattered radiation from the sample itself is minimized. The proposed sample preparation method is useful particularly for the analysis of heavy metals in liquid samples with for TXRF disturbing matrices, e.g. sea water.  相似文献   

4.
Vapor phase treatment (VPT) is a pretreatment with hydrofluoric acid vapor to raise the sensitivity of total reflection X-ray fluorescence spectroscopy (TXRF) for trace metal analysis on silicon wafers. The International Organization for Standardization/Technical Committee 201/Working Group 2 (ISO/TC201/WG2) has been investigating the method to analyze 109 atoms/cm2 level of metallic contamination on the silicon wafer surface. Though VPT can enhance the TXRF signal intensity from the metallic contamination, it has turned out that the magnitude of the enhancement varies with the type of methods and the process conditions. In this study, approaches to increase TXRF intensity by VPT are investigated using a fuming chamber in an automated VPD instrument. Higher signal intensity can be obtained when condensation is formed on the sample surface in a humidifying atmosphere and with a decreasing stage temperature. Surface observations with SEM and AFM show that particles with ~ 4 μm in diameter are formed and unexpectedly they are dented from the top surface level.  相似文献   

5.
Multielemental determinations in samples of various types of bee honey, pollen and bee tissue have been carried out using total reflection X-ray fluorescence spectrometry (TXRF) and radioisotope excited X-ray fluorescence spectrometry (XRF). The objective was to establish whether the elemental content of bee honey, in particular, correlates with any useful information about the environment, variety of honey, etc. An attempt has also been made to determine the X-ray techniques' ability to compete with atomic absorption spectrometry (AAS) and inductively coupled plasma-atomic emission spectrometry (ICP-AES), with regard to elemental sensitivity, accuracy, sample preparation procedures, and in particular, economic performance, which is very important in selecting an appropriate technique for the analysis of large numbers of samples. The results confirm the advantages of the TXRF method for trace element analysis, but only when utilising monochromatic excitation and selecting a proper sample preparation procedure. The radioisotope XRF technique, which does not require any sample preparation, is still very competitive in analysis of elements with concentrations above a few ten ppm. Preliminary results also confirm some correlations between the elemental content of honey and the status of the environment, and encourage further work in this direction  相似文献   

6.
    
Summary The total reflection X-ray fluorescence technique (TXRF) was used for the routine analysis of city waste incineration ash. Subjects of these analyses were digested ashes (a) and aqueous leaching solutions (b). The accuracy of TXRF was estimated in comparison with atomic absorption spectroscopy (AAS) and atomic emission spectroscopy (ICP-AES) measurements. Satisfactory agreement was found between the results of the different methods for both types of samples.In addition to the direct measurements without prior sample preparation sample type (b) was used to compare three different extraction methods. In each case a dithiocarbamate derivative was used as complexing agent. The separation of the precipitate was performed with a silicagel column, by liquid/liquid extraction and by leaching the sample on a quartz target. Satisfying agreement was found between direct measurements and the different extraction methods.  相似文献   

7.
Ge substrates are recently being reconsidered as a candidate material for the replacement of Si substrates in advanced semiconductor devices. The reintroduction of this material requires reengineering of the standard IC processing steps. In this paper, we present the extension of the methodology of vapor phase decomposition–droplet collection–total reflection X-ray fluorescence spectrometry (VPD–DC–TXRF) for metallic contamination analysis towards Ge substrates. A first step that asked for adaptation was the collection chemistry as the Ge wafers surface is not hydrophobic after the VPD treatment. The contact angle could be significantly increased using a concentrated HCl solution. This chemistry has been proved to perform well in the collection of metals from intentionally contaminated Ge wafers. A second step that needed optimization was the matrix removal method as a sample preparation step prior to the TXRF analysis. First, the upper limits of TXRF on Ge containing solutions have been characterized. The accuracy of TXRF is found to be acceptable for Ge contents lower than 1×1014 atoms (250 ppb in 50 μL) but decreases systematically with higher Ge contents. Fortunately, Ge can be volatilized at low temperatures as GeCl4 by the addition of HCl. The parameters within this method have been investigated with respect to the removal of Ge and the recovery of metal traces. Finally, the full VPD–DC–TXRF method has been applied on intentionally contaminated Ge wafers and proved to be very accurate.  相似文献   

8.
Nikolai Alov 《Analytical letters》2018,51(11):1789-1795
Novel rapid determination of copper-zinc ore elemental composition by total reflection X-ray fluorescence (TXRF) is proposed. Approaches for solid state sample analysis by TXRF are provided. The sample preparation is chosen to obtain the suspensions in ethylene glycol. The optimum suspension preparation conditions (sample mass, volume of dispersion medium) and the measurement conditions (internal standard element, spectra acquisition time) were determined. The sedimentation stability of suspensions was studied. It was found that the suspensions remain stable for approximately 2?min, which is sufficiently long for the sampling the suspension. The proposed technique allows determining the elemental composition of solid ore samples without sample digestion. The sample preparation time takes approximately 20?min. The relative standard deviation of the analytical results did not exceed 10%.  相似文献   

9.
Total-reflection X-ray fluorescence (TXRF) is widely used for the control of metallic contamination caused by surface preparation processes and silicon materials. At least three companies supply a variety of TXRF systems to the silicon integrated circuit (IC) community, and local calibration of these systems is required for their day to day operation. Differences in local calibration methods have become an issue in the exchange of information between IC manufacturers' different FABs (Fabrication Facility) and also between silicon suppliers and IC FABs. The question arises whether a universal set of fluorescence yield curves can be used by these different systems to scale system sensitivity from a single element calibration for calculation of elemental concentrations. This is emphasized by the variety of experimental conditions that are reported for TXRF data (e.g. different angles of incidence for the same X-ray source, different X-ray sources, etc.). It appears that an instrumental factor is required. We believe that heavy ion backscattering spectrometry (HIBS) provides a fundamental method of calibrating TXRF reference materials, and can be used in calculating this instrumental factor. In this paper we briefly describe the HIBS system at the Sandia National Laboratories HIBS User Facility and its application to the calibration of TXRF reference materials. We will compare HIBS and TXRF mapping capabilities and discuss the issues associated with the restrictions of some older TXRF sample stages. We will also discuss Motorola's cross-calibration of several TXRF systems using different elements as references.  相似文献   

10.
Two new preparation techniques for total-reflection X-ray fluorescence (TXRF) element determination of single freshwater crustacean specimens (dry weight: 3–40 μg ind−1) have been developed and tested using Daphnia pulex from a deep, oligotrophic freshwater lake located in southern Chile. Dry method: Specimens were washed with 0.2 μm filtered lake water and frozen in liquid nitrogen. The freeze-dried Daphnia specimens were weighed using an ultra-fine microbalance and placed on quartz glass carriers for TXRF analysis. Wet method: Specimens were washed with 0.2 μm filtered lake water and placed on quartz glass carriers for TXRF analysis and dried in air. The dry weight was determined using the previously established body length–dry weight relationship. Method validation for both the dry and the wet preparation method in combination with TXRF spectrometry for the element determination in small single freshwater crustaceans showed that both methods can be used for routine investigations. There were no significant differences between the dry and the wet methods concerning the elements Ca, K, Fe, Zn, Br, P, Cu, but the determination of Mn, S and Sr revealed significant differences between the two methods. It seems that the dry method yields more precise results, but the wet method is easier to handle in the field when samples cannot be fixed with liquid nitrogen.  相似文献   

11.
建立了微波消解前处理,全反射X射线荧光法(TXRF)同时测定松花粉中K、Ca、Ti、Mn、Fe、Ni、Cu、Zn和Rb9种生命元素含量的分析方法.松花粉原料经过微波消解前处理后,采用全反射X射线荧光光谱净计数、QXAS分析软件解谱和单一内标法进行定量分析.比较了干灰化法、湿消解法和微波消解法3种前处理方法的效果,并确立微波消解法作为样品前处理方法.用微波消解- TXRF法测定了花粉标准物质中的上述9种元素,并计算得到其仪器检出限(LLD)为0.002~0.054 mg/L,方法检出限(LDM)为0.004~0.122 mg/kg.TXRF法测定各元素的相对标准偏差(RSDs)为1.0%~5.5%.该方法操作简单、样品用量少、检出限低,对实际样品松花粉的测定结果与ICP - MS法无显著性差异.  相似文献   

12.
Microanalytical methods suitable for the determination of Fe, Cu in HT-29 (human colon adenocarcinoma) cells treated with different iron compounds (Fe(II) sulfate, Fe(III) chloride, Fe(III) citrate and Fe(III) transferrin) and cultured in medium supplemented or not with 10% (v/v) fetal calf serum (FCS) by total reflection X-ray fluorescence spectrometry (TXRF) and simultaneous graphite furnace atomic absorption spectrometry (GF-AAS) were developed. The developed TXRF method was also suitable for Zn determination in the samples. The main advantage of the proposed methods is the execution of all sample preparation steps following incubation and prior to the elemental analysis in the same Eppendorf tubes. Sample preparation was performed at microscale (115 μL sample volume) with 65% nitric acid and 30% hydrogen peroxide. According to scanning electron microscopic measurements, the organic matrix of the cell samples could be eliminated to the extent that accurate results were obtained for Cu and Fe by analyzing the same samples by TXRF and GF-AAS. Concerning the iron uptake, HT-29 cells incubated in FCS-free medium contained Fe in cca. 5-50 times higher amounts compared to cells cultured in FCS supplemented medium. Pronounced differences in the iron uptake compared to the iron supply (inorganic vs. organic chelated as well as iron(II) vs. iron(III)) were observed in the case of cell lines incubated in FCS-free medium.  相似文献   

13.
A deposition system capable of delivering picoliter quantities of solution in programmable arrays was investigated as a method for sample preparation for total reflection X-ray fluorescence (TXRF) spectroscopy. Arrays of trace metals in solution were deposited on Si wafers. The array deposits provide a capability of depositing closely spaced (100 μm or less), typically 5–20 μm diameter droplets in an area that can be matched to the analysis spot of the TXRF detector. The dried depositions were physically characterized and the effect of deposition type and matrix on the TXRF signal was investigated.  相似文献   

14.
At present, there is a considerable interest in Hg monitoring in wastewater samples due to its widespread occurrence and the high toxicity of most of its compounds. Hg determination in water samples by means of total reflection X-ray fluorescence spectrometry (TXRF) entails some difficulties due to the high vapor pressure and low boiling point of this element that produce evaporation and loss of Hg from the surface of the reflector during the drying process, commonly used for sample preparation in TXRF analysis.The main goal of the present research was to develop a fast and simple chemical strategy to avoid Hg volatilization during the analysis of wastewater samples by TXRF spectrometry. Three different analytical procedures were tested for this purpose: (i) increasing the viscosity of the wastewater sample by adding a non-ionic surfactant (Triton® X-114), (ii) Hg immobilization on the quartz reflectors using the extractant tri-isobutylphosphine (Cyanex 471X) and (iii) formation of a stable and non-volatile Hg complex into the wastewater sample. The best analytical strategy was found to be the formation of a Hg complex with thiourea (pH = 10) before the deposition of 10 μL of sample on the reflector for following TXRF analysis. Analytical figures of merit such as linearity, limits of detection, accuracy and precision were carefully evaluated. Finally, the developed methodology was applied for the determination of Hg in different types of wastewater samples (industrial effluents, municipal effluents from conventional systems and municipal effluents from constructed wetlands).  相似文献   

15.
About two-thirds of the Hungarian population is living in areas where drinking water contains less than 0.025 mg/L I2. Iodine is an essential element required for the synthesis of thyroid hormones. The recommended daily allowance (RDA) is 0.150 mg for adults (WHO [17]). In the case of iodine deficiency mineral water containing iodine and seaweed products could serve as the natural source of this element. In the present study, the capability and limitations of total reflection X-ray fluorescence (TXRF) and inductively coupled plasma atomic emission (ICP-AES) spectrometry for the determination of iodine are discussed, in the case of commercially available dietary supplements and differently processed seaweed (kelp) products. Multi-mineral tablets and kelp samples were digested using concentrated nitric acid before analysis. Extraction using a 25% ammonia solution was proved to be effective as an alternative sample preparation procedure for seaweed and dietary supplement tablets containing iodine. Precipitation of silver iodide, as a sample preparation step of mineral water, was applied to prevent loss of volatile iodine during solvent evaporation. ICP-AES measurement was found to be seriously affected by spectral line coincidence between the prominent line of iodine and the adjacent phosphorus line. TXRF was proved to be line coincidence free and suitable for iodine analysis. TXRF determination of iodine in mineral water, in seaweed samples and in dietary supplement tablets has not been reported yet.  相似文献   

16.
A procedure for evaluation of the mass ratio between Ta and Nb in LiNb1−xTaxO3 single crystals by total reflection X-ray fluorescence spectrometry (TXRF) is described. The developed procedure does not require chemical preparation of the samples and it proves to be fast (30 min for sample preparation and 10 min for analysis), precise (down 1% RSD) and easy to perform. To check the methodology, the lattice parameter of each LiNb1−xTaxO3 sample was determined by powder X-ray diffraction. While the a hexagonal lattice parameter remains constant, a strong and linear dependence of the c hexagonal lattice parameter with Ta content in molar percentage has been observed for the first time.  相似文献   

17.
A nanoliter droplet deposition unit was developed and characterized for application of sample preparation in TXRF. The droplets produced on quartz reflectors as well as on wafers show a good reproducibility, also the accuracy of the pipetted volume could be proved by a quantitative TXRF analysis using an external standard. The samples were found to be independent of rotation of the sample carrier. Angle scans showed droplet residue behavior, and the fluorescence signal is relatively invariant of the angle of incidence below the critical angle, which is useful for producing standards for external calibration for semiconductor surface contamination measurements by TXRF. Further it could be demonstrated that the nanoliter deposition unit is perfectly able to produce patterns of samples for applications like the quantification of aerosols collected by impactors.  相似文献   

18.
The features of electrochemical deposition and co-deposition of copper, cadmium and lead from aqueous solutions on disc glass-ceramic carbon (GCC) electrode surfaces were studied by total-reflection X-ray fluorescence analysis (TXRF). This method was found to be highly sensitive to the varieties of electrodeposit morphology and depth distribution of elements on the electrode surface. It allows identification of the mechanisms of metal nucleation and growth of thin film electrodeposits. The results of the TXRF study are in good agreement with the recent data of a number of spectroscopic and microscopic methods of solid surface analysis. The polished GCC was shown to be an excellent material for preparation of the sample carriers for TXRF analysis.  相似文献   

19.
The comparison between inductively coupled plasma optical emission spectrometry (ICP-OES) and total reflection X-ray fluorescence spectrometry (TXRF) for simultaneous determination of metal content (Cr, Cu, Fe, Mn, Pb and Zn) in mosses from the Metropolitan Area of the Toluca Valley was performed. Epiphytic mosses (Fabriona ciliaris and Leskea angustata) were collected in two sampling campaigns and were digested with HNO3, HCl and HF for ICP-OES method and HNO3 and HCl for TXRF method. The certified reference material (IAEA-336, Lichen) and the Standard Reference Material (SRM-1573, tomato leaves) were used for the quality control and to evaluate trueness and precision. Linearity, detection and quantification limits were also determined. Results show an ICP-OES and TXRF trueness mean of 101 ± 5% and 97 ± 9%, respectively; the relative standard deviation (RSD percent) was less than 17% in both methods. The moss samples exhibit a satisfactory precision (RSD ≤ 20%), because the RSD percent for ICP-OES, from 2% to 15%, and that for TXRF, from 1% to 17%, were obtained. One factor experimental design and simple regression analysis (α = 0.05) were used to compare the ICP-OES and TXRF metal concentrations. The statistical results do not show significantly different values for Cu, Mn, Pb and Zn in both the sample campaigns. In addition, the average results for Cr in the first sample campaign (30.3 ± 11.4 mg/kg for ICP-OES and 18.6 ± 9.8 mg/kg for TXRF) and Fe values in the second sample campaign (10,810 ± 2980 mg/kg for ICP-OES and 8380 ± 2350 mg/kg for TXRF) were significantly different in both methods. These differences are attributed to an incomplete sample digestion in the TXRF sample preparation. The results of the simple regression analyses show p-value less than 0.05, which indicates an equivalent and significant relation between ICP-OES and TXRF.  相似文献   

20.
The contents of Cl, Ca, K, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb in raw coal fly ash from five Bulgarian power plants were determined by total reflection X-ray fluorescence (TXRF), using gallium as the internal standard. The samples were analysed as in slurry form in Triton? X-114. The experimental parameters, such as grain size, concentrations of fly ash slurry and excitation time were optimised. For validation of the method, the certified reference material BCR-176R fly ash was used. The precision of the results obtained is characterised by a relative standard deviation of approximately 10%. The resulting data confirm the suitability of TXRF for the simultaneous determination of major, minor and trace elements in coal fly ash samples. Further advantages provided by TXRF are easy sample preparation (no sample dissolution) and the small sample amount required for analysis.  相似文献   