In this work, tetramethylammonium hydroxide (TMAH) was used to solubilize the DORM-1 dogfish muscle certified reference material as a model substance for the determination of As, Cd, Pb and Se by electrothermal atomic absorption spectrometry (ET AAS). The sample was mixed with a small amount of TMAH and heated to 60 °C for 10 min in a water bath. After dissolution, As and Se were determined using palladium and magnesium nitrates as a chemical modifier added in solution. For Cd and Pb, best results were obtained with a mixture of 250 μg of each of iridium and rhodium as permanent modifiers. In both cases, the calibration was performed with aqueous solutions in 0.2% v/v HNO3. The temperature program for each analyte was optimized using pyrolysis and atomization curves established with the fish reference material. The detection limits in dry samples and the characteristic mass values were: Cd 0.005 μg g−1 and 0.9 pg; Pb 0.04 μg g−1 and 7.6 pg; As 0.4 μg g−1 and 13 pg and Se 0.6 μg g−1 and 20 pg, respectively. Results from the determination of these elements in the DORM-1 certified fish reference material were within the 95% confidence interval of the certified values.  相似文献   

2.
The mass fractions of Hg and methylmercury, in two certified reference materials, NIST2710 and DORM-2, have been determined by total and species-specific isotope dilution analysis (IDA), respectively, and uncertainty budgets for each analysis calculated. The mass fraction of Hg in NIST2710 was determined by ID using multicollector sector field inductively coupled plasma mass spectrometry (MC-SF-ICP-MS) whilst the mass fraction of methylmercury in DORM-2 was determined using HPLC coupled with quadrupole ICP-MS.

The extent of equilibration between the spike and the particulate bound mercury compounds was studied temporally by monitoring the 200Hg:199Hg isotope amount ratio and by determining the total amount of Hg in the liquid phase. For the NIST2710 complete equilibration was only achieved when concentrated HNO3 in combination with a microwave digestion was employed, and good agreement between the found (31.7±4.0 μg g−1, expanded uncertainty k=2) and certified (32.6±1.8 μg g−1) values was obtained. For DORM-2 complete equilibration of methylmercury between the liquid and solid phases was achieved when using 50:50 H2O:CH3OH (v/v) and 0.01% 2-mercaptoethanol as the solvent. Even though only 50% of the analyte was extracted into the liquid phase, complete equilibration was achieved, hence, the found methylmercury mass fraction (4.25±0.47 μg g−1, expanded uncertainty k=2) was in good agreement with the certified value (4.47±0.32 μg g−1).  相似文献   


3.
de Jesus A  Silva MM  Vale MG 《Talanta》2008,74(5):1378-1384
A new method for F AAS determination of sodium and potassium in biodiesel using water-in-oil microemulsion as sample preparation is proposed. The method was investigated for biodiesel produced from different sources, as soybean, castor and sunflower oil and animal fat and was also applied for vegetable oils. The optimized condition for microemulsion formation was 57.6% (w/w) of n-pentanol, 20% (w/w) of biodiesel or vegetable oil, 14.4% (w/w) of Triton X-100 and 8% (w/w) of water (aqueous standard of KCl or NaCl in/or diluted HNO3). The optimized instrumental parameters were: aspiration rate of 2 mL min−1 and the flame composition of 0.131 of C2H2/air ratio. For comparison purpose, the determination of sodium and potassium were also carried out according to European norms (EN 14108 and EN 14109, respectively). These norms are applied for determination of sodium and potassium in fatty acid methylic ester samples and consist in the sample dilution using organic solvent and determination by F AAS. The stability of microemulsified aqueous standards and samples was investigated and it was found to be stable for at least 3 days while the organic standard diluted with xylene showed a decrease around of 15% in the analytical signal in 1 h. The limits of detection were 0.1 μg g−1 and 0.06 μg g−1 and the obtained characteristic concentrations were 25 μg L−1 and 28 μg L−1 for sodium and potassium, respectively. The proposed method presented two times better limits of detection and better precision (0.4–1.0%) when compared with the dilution technique (1.5–4.5%). The accuracy of the method was evaluated through recovery tests and comparison with the results obtained by dilution technique. The recoveries ranged from 95% to 115% for biodiesel and 90% to 115% for vegetable oil samples. Comparison between the results obtained for biodiesel by both methods showed no significant differences at the 95% confidence level according to a Student's t-test. This study shows that the proposed method based on microemulsion as sample preparation can be applied as an efficient alternative for sodium and potassium determination in biodiesel samples.  相似文献   

4.
A procedure has been developed for the simultaneous determination of traces amounts of Cd, Cr, Cu, Mn, Ni and Pb from saline oil-refinery effluents and digested vegetable samples using inductively coupled plasma optical emission spectrometry (ICP OES). The procedure is based on cloud point extraction (CPE) of these metals as 2-(bromo-2-pyridylazo)-5-diethyl-amino-phenol (Br-PADAP) complexes into a micellar phase of octylphenoxypolyethoxyethanol (Triton X-114). Optimization of the procedure was performed by response surface methodology (RSM) using a Doehlert design. Principal components (PC) were used to simplify the multiple response analysis. A response surface for the first PC score is useful in determining the optimum conditions for the Cd, Cr, Cu, Mn and Pb determinations whereas the second PC is highly correlated with the Ni response. Improvement factors of 22, 36, 46, 25, 65 and 39, along with limits of detection (3σB) of 0.081, 0.79, 0.38, 0.83, 0.28 and 0.69 μg L−1, and precision expressed as relative standard deviation (%R.S.D., n = 8, 20.0 μg L−1) of 1.5, 2.2, 3.5, 2.6, 2.5 and 2.5 were achieved for Cd, Cr, Cu, Mn, Ni and Pb, respectively. The accuracy was evaluated by spike tests in oil-refinery effluent samples and analysis of a vegetable certified reference material (NIST 1571, orchard leaves). Results found were in agreement with certified values.  相似文献   

5.
Goswami A  Singh AK  Venkataramani B 《Talanta》2003,60(6):1141-1154
The silica gel modified with (3-aminopropyl-triethoxysilane) was reacted with 5-formyl-8-hydroxyquinoline (FHOQx) to anchor 8-quinolinol ligand on the silica gel. It was characterised with cross polarisation magic angle spinning (CPMAS) NMR and diffuse reflectance infrared Fourier transformation (DRIFT) spectroscopy and used for the preconcentration of Cu(II), Pb(II), Ni(II), Fe(III), Cd(II), Zn(II) and Co(II) prior to their determination by flame atomic absorption spectrometry. The surface area of the modified silica gel has been found to be 227 m2 g−1 and the two pKa values as 3.8 and 8.0. The optimum pH ranges for quantitative sorption are 4.0–7.0, 4.5–7.0, 3.0–6.0, 5.0–8.0, 5.0–8.0, 5.0–8.0 and 4.0–7.0 for Cu, Pb, Fe, Zn, Co, Ni and Cd, respectively. All the metals can be desorbed with 2.5 mol l−1 HCl or HNO3. The sorption capacity for these metal ions is in range of 92–448.0 μmol g−1 and follows the order Cd3, NaCl, NaBr, Na2SO4 and Na3PO4, glycine, sodium citrate, EDTA, humic acid and cations Ca(II), Mg(II), Mn(II) and Cr(III) in the sorption of all the seven metal ions are reported. The preconcentration factors are 150, 250, 200, 300, 250, 300 and 200 for Cd, Co, Zn, Cu, Pb, Fe and Ni, respectively and t1/2 values <1 min except for Ni. The 95% extraction by batch method takes ≤25 min. The simultaneous enrichment and determination of all the metals are possible if the total load of the metal ions is less than sorption capacity. In river water samples all these metal ions were enriched with the present ligand anchored silica gel and determined with flame atomic absorption spectrometer (R.S.D.≤6.4%). Cobalt contents of pharmaceutical samples (vitamin tablet) were preconcentrated with the present chelating silica gel and estimated by flame AAS, with R.S.D.1.4%. The results are in the good agreement with the certified value, 1.99 μg g−1 of the tablets. Iron and copper in certified reference materials (synthetic) SLRS-4 and SLEW-3 have been enriched with the modified silica gel and estimated with R.S.D.<5%.  相似文献   

6.
Reactivity and concentration of additives, especially activated charcoal, employed for the Lyocell process, enhance the complexity of reactions in cellulose/N-methylmorpholine-N-oxide monohydrate solutions. Analytical control of the starting materials is a basic requirement to know the concentration of heavy metals, which are potential initiators of autocatalytic reactions. Seven activated charcoal and two carbon black samples have been analyzed regarding their content of seven elements, Cr, Cu, Fe, Mn, Mo, Ni and V using direct solid sampling high-resolution continuum source graphite furnace AAS (SS-HR-CS GF AAS) and inductively coupled plasma optical emission spectrometry (ICP OES) after microwave-assisted acidic digestion as a reference method. The limits of detection of the former technique are 1-2 orders of magnitude lower than those of ICP OES and comparable to those of more sophisticated techniques. For iron the working range of HR-CS GF AAS has been expanded by simultaneous measurement at two secondary absorption lines (344,099 nm and 344,399 nm). Partial least-squares regression between measured and calculated temperatures for beginning exothermicity (Ton) has been used to investigate the prediction capability of the investigated techniques. Whereas the ICP OES measurements for seven elements resulted in an error of prediction of 3.67%, the results obtained by SS-HR-CS GF AAS exhibited a correlation coefficient of 0.99 and an error of prediction of only 0.68%. Acceptable correlation has been obtained with the latter technique measuring only three to four elements.  相似文献   

7.
A flow injection procedure involving continuous acid leaching for lead and cadmium determination in hair samples of persons in permanent contact with a polluted workplace environment by flame atomic absorption spectrometry is proposed. Variables such as sonication time, nature and concentration of the acid solution used as leaching solution, leaching temperature, flow-rate of the continuous manifold, leaching solution volume and hair particle size were simultaneously studied by applying a Plackett–Burman design approach. Results showed that nitric acid concentration (leaching solution), leaching temperature and sonication time were statistically significant variables (confidence interval of 95%). These last two variables were finally optimised by using a central composite design. The proposed procedure allowed the determination of cadmium and lead with limits of detection 0.1 and 1.0 μg g−1, respectively. The accuracy of the developed procedure was evaluated by the analysis of a certified reference material (CRM 397, human hair, from the BCR). The proposed method was applied with satisfactory results to the determination of Cd and Pb in human hair samples of workers exposed to welding fumes.  相似文献   

8.
A flow injection (FI) on-line preconcentration procedure by using a nanometer-sized alumina packed micro-column coupled to inductively coupled plasma mass spectrometry (ICP-MS) was described for simultaneous determination of trace metals (V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb) in the environmental samples. The effects of pH value, sample flow rate, preconcentration time, and interfering ions on the preconcentration of analytes have been investigated. Under the optimized operating conditions, the adsorption capacity of the nanometer-sized alumina for V, Cr, Mn, Co, Ni, Cu, Zn, Cd and Pb were found to be 11.7, 13.6, 15.7, 9.5, 12.2, 13.3, 17.1, 17.7 and 17.5 mg g−1, respectively. With 60 s preconcentration time and 60 s elution time, an enrichment factor of 5 and the sampling frequency of 15 h−1 were obtained. The proposed method has been applied to the determination of trace metals in environmental certified reference materials and natural water samples with satisfactory results.  相似文献   

9.
The determination of cobalt in marine sediments by electrothermal atomic absorption spectrometry was studied using no modifier and magnesium and titanium as modifiers. Titanium is one of the major sediment constituents, which widely affects the cobalt determination and it was studied as a chemical modifier since it was the only concomitant that increased the cobalt signal in the concentration range usually found in sediments. The performance of Mg and Ti as chemical modifiers was compared relative to maximum pyrolysis and atomization temperatures, linear calibration range, sensitivity and matrix effects. The pyrolysis curves showed that the analyte could be stabilized up to 1400 °C when either Ti or Mg(NO3)2 was present, while only 1000 °C could be used in the absence of a modifier. The optimum atomization temperature was 2500 °C in all cases. Analytical curves were compared using no modifier, 5 μg Ti and 100 μg Mg(NO3)2 as modifiers, and the linear range found was up to approximately 4 ng Co whether a modifier was used or not. With Ti as a chemical modifier, analytical curves for cobalt in aqueous solution and in a synthetic matrix resulted in the same sensitivity (m0=55 pg), whereas the use of Mg led to characteristic mass values of 59 and 72 pg in aqueous solution and in a synthetic matrix, respectively, showing some matrix effect. The detection limits (3σ, n=10) were 0.4 μg g−1 using no modifier and 0.3 μg g−1 with Ti as a modifier in the original matrix. A reference estuarine sediment NIST 1646 with a non-certified content of 10.5 μg g−1 Co was analyzed and the found value of 10.9±2.4 μg g−1, (n=3), using Ti as chemical modifier and calibration against aqueous standards, was in good agreement with the recommended value.  相似文献   

10.
A low-flow air-cooled inductively coupled plasma (ICP) design for optical emission spectrometry (OES) with axial plasma viewing is described and an evaluation of its analytical capabilities in trace element determinations is presented. Main advantage is a total argon consumption of 0.6 L min−1 in contrast to 15 L min−1 using conventional ICP sources.The torch was evaluated in trace element determinations and studied in direct comparison with a conventional torch under the same conditions with the same OES system, ultrasonic nebulization (USN) and single-element optimization. A variety of parameters (x-y-position of the torch, rf power, external air cooling, gas flow rates and USN operation parameters) was optimized to achieve limits of detection (LOD) which are competitive to those of a conventional plasma source.Ionic to atomic line intensity ratios for magnesium were studied at different radio frequency (rf) power conditions and different sample carrier gas flows to characterize the robustness of the excitation source. A linear dynamic range of three to five orders of magnitude was determined under compromise conditions in multi-element mode. The accuracy of the system was investigated by the determination of Co, Cr, Mn, Zn in two certified reference materials (CRM): CRM 075c (Copper with added impurities), and CRM 281 (Trace elements in rye grass). With standard addition values of 2.44 ± 0.04 and 3.19 ± 0.21 μg g−1 for Co and Mn in the CRM 075c and 2.32 ± 0.09, 81.8 ± 0.4, 32.2 ± 3.9 for Cr, Mn and Zn, respectively, were determined in the samples and found to be in good agreement with the reported values; recovery rates in the 98-108% range were obtained. No influence on the analysis by the matrix load in the sample was observed.  相似文献   

11.
Grobecker KH  Detcheva A 《Talanta》2006,70(5):962-965
Certified reference materials (CRMs) of different origin were used to validate the direct determination of total mercury by solid sampling Zeeman atomic absorption spectrometry (SS-ZAAS) and a specially designed furnace. The temperature program provides only for one step. Atomisation of mercury and pyrolysis of the matrix is performed at a constant temperature in the range of 900–1000 °C. Calibration points achieved by CRMs and aqueous solutions are covered by one calibration line, indicating the absence of matrix effects. Relatively high amounts of chlorine, known for causing problems in mercury determination do not influence analytical results. The excellent accuracy of the method results in a very good agreement with the certified values. The precision of SS-ZAAS measurements in a range from 0.5 to 50 ng Hg does not exceed 3% R.S.D. A limit of quantification of 0.008 μg g−1 Hg was achieved.  相似文献   

12.
By HG-AFS, a new method was proposed for simultaneous determination of total arsenic and total selenium existed in the Chinese medicinal herbs in tartaric acid medium. The effects of analytical conditions and coexisting ions on the fluorescence signal intensity of analytes were investigated. The proposed method was provided with linear response ranges above 22 μg l−1 for As and 44 μg l−1 for Se, and the detection limits of 0.13 and 0.12 μg l−1 were obtained for As and Se respectively. The recoveries of 93.8–96.1% for As and 95.3–99.1% for Se, and the precision of 1.2–3.8% and 2.4–5.3% (R.S.D., n = 8) respectively, were obtained via simultaneous determined four samples of Chinese medicinal herbs and three certified botanic reference materials successfully. The proposed method has the advantages of simple operation, high sensitivity and high efficiency.  相似文献   

13.
A procedure for the determination of As, Pb, Se and Sn in sediment slurries by electrothermal vaporization inductively coupled plasma mass spectrometry is proposed. The slurry, 1 mg ml−1, is prepared by mixing the sample ground to a particle size 50 μm with 5% v/v nitric and 1% v/v hydrofluoric acids in an ultrasonic bath. The slurry was homogenized with a constant flow of argon in the autosampler cup, just before transferring an aliquot to the graphite furnace. The tube was treated with Ru as a permanent modifier, and an optimized mass of 1 μg of NaCl was added as a physical carrier. The pyrolysis temperature was optimized through pyrolysis curves, and a compromised temperature of 800 °C was used; the vaporization temperature was 2300 °C. The effect of different acid concentrations in the slurry on the analyte signal intensities was also evaluated. The accuracy of the method was assured by the analysis of certified reference sediments MESS-2, PACS-2 and HISS-1 from the National Research Council Canada, SRM 2704 and SRM 1646a from the National Institute of Standards and Technology and RS-4 from a round robin test, using external calibration with aqueous standards prepared in the same medium as the slurries. The obtained concentrations were in agreement with the certified values according to the Student's t-test for a confidence level of 95%. The detection limits in the samples were: 0.17 μg g−1 for As; 0.3 μg g−1 for Pb; 0.05 μg g−1 for Se and 0.28 μg g−1 for Sn. The precision found for the different sediment samples, expressed as R.S.D. was 1–8% for As, 2–9% for Pb, 6–12% for Se and 3–8% for Sn (n=5).  相似文献   

14.
Grigoletto T  Oliveira Ed  Gutz IG 《Talanta》2005,67(4):791-797
The new electrolytic dissolution in batch of aluminum alloys samples as grains or turns and the determination of Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb and Ti by ICP OES was investigated. In on-line electrodissolution procedures described in the literature, samples were restricted to be in the form of solid blocks or plates with one polished flat face. Here, the sample was loaded in the barrel of a modified disposable syringe (the anodic semi-cell) and pressed with a modified plunger fitted with a platinum disk to establish electrical contact with the analyte. This arrangement was introduced in a beaker containing the electrolyte (1 mol L−1 HNO3) and a platinum wire as the cathode. The resulting solution from electrodissolution (0.6 A) was used for the ICP OES determinations. The influence of the aluminum concentration increase on the determination of the elements was evaluated. Electrodissolution of certified reference materials and commercial samples revealed relative errors lower than 10% for the elements Fe, Cu, Mg, Ni, Cr, Zn and Ti (when their content is above 0.1%). Higher inaccuracies (>10%) were observed for Mn and for Fe in B.C.S. 268/1 reference material certified. The proposed method presented a relative standard deviations (R.S.D.) lower or circa 10% to all of the elements (except Pb). In comparison with traditional acid dissolution, the proposed electrodissolution method is relatively fast (about 30 min), it is clean (there is no projection of solution) and simple (heating and fumes exhaust system were not necessaries).  相似文献   

15.
Ultrasonic slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) has been applied to determine Ga, Ge, As, Se and Sb in fly ash samples. The influences of instrument operating conditions and slurry preparation on the ion signals were reported. Pd and ascorbic acid were used as the mixed modifiers to enhance the ion signals. This method has been applied to determine Ga, Ge, As, Se and Sb in NIST SRM 1633a and 1633b coal fly ash reference materials and a fly ash sample collected locally. Since the sensitivities of the elements studied in slurry solution and aqueous solution were different slightly, analyte addition technique was used for the determination of Ga, Ge, As, Se and Sb in these samples. The As and Se analysis results of the reference materials agreed with the certified values. The results for which no certified value was available were also found to be in good agreement between the ETV-ICP-MS results and the reference values. The reference value was obtained by digesting the samples and analyzing the digested sample solutions by pneumatic nebulization Dynamic Reaction Cell™ (DRC) ICP-MS. The method detection limits estimated from analyte addition curves were about 0.23, 0.13, 0.17, 0.25 and 0.11 μg g−1 for Ga, Ge, As, Se and Sb, respectively, in original fly ash samples.  相似文献   

16.
Summary For a long time simultaneous multielement determination by AAS has been a subject of intensive research. In this work a simultaneous multielement atomic absorption spectrometry method is described in a special new arrangement, called frequency modulated simultaneous AAS (FremsAAS), using fiberoptics, interference filters and frequency modulation and demodulation by lock-in amplifiers as main devices. Purpose of this work was to equip the FremsAAS with a D2-background correction and to test it with certified reference materials. Mn, Cd, Pb, Cu, Ni, Cr and Zn had been determined simultaneously (three at a time) in sewage sludge (BCR/CRM 146), estuarine sediment (BCR/CRM 277) and phosphate rock (BCR/CRM 32) with good feasibility. Frequency modulated simultaneous AAS with background correction (FremsAASUK) represents an interesting alternative to known instruments.Dedicated to Prof. Dr. V. Krivan on the occasion of his 60th birthday  相似文献   

17.
Arslan Z 《Talanta》2005,65(5):1326-1334
A method is developed for determination of trace elements, including Ag, As, Cd, Co, Cr, Cu, Mn, Ni, Se, Tl and Zn, in fish otoliths by electrothermal vaporization inductively coupled plasma mass spectrometry (ETV-ICP-MS). Hydrofluoric acid was used to precipitate calcium resulting from acid dissolution of otolith calcium carbonate. Initial acidity of the sample solution influenced the precipitation efficiency of calcium fluoride. Up to 99.5% of Ca was precipitated in solutions that contained less than 2% (v/v) HNO3. Recoveries of the elements obtained from spiked artificial otolith solutions were between 90 and 103%. Stabilization of the elements within the ETV cell was achieved with 0.3 μg Pd/0.2 μg Rh chemical modifier that also afforded optimum sensitivity for multielement determination. The method was validated by the analysis of a fish otolith reference material (CRM) of emperor snapper, and then applied to the determination of the trace elements in otoliths of several fish species captured in Raritan Bay, New Jersey. Results indicated that fish physiology and biological processes could influence the levels of Cu, Mn, Se and Zn in the otoliths of fish inhabiting a similar aqueous environment. Otolith concentrations of Cr and Ni did not show any significant differences among different species. Concentrations for Ag, As, Cd, Co and Tl were also not significantly different, but were very low indicating low affinity of otolith calcium carbonate to these elements.  相似文献   

18.
Vale MG  Silva MM  Damin IC  Sanches Filho PJ  Welz B 《Talanta》2008,74(5):1385-1391
In recent work, it has been shown that electrothermal atomic absorption spectrometry (ET AAS) can be used to differentiate between volatile and non-volatile nickel and vanadium compounds in crude oil. In the present work, the distribution of these two groups of compounds over different fractions of crude oil was investigated. For this purpose two crude oil samples were separated in two steps: firstly, the asphaltenes were precipitated with n-heptane, and secondly, the maltenes were loaded on a silica column and eluted with solvents of increasing polarity. The four fractions of maltenes eluted from silica column were: F1, saturated and light aromatics; F2, polyaromatics; F3, resins; and F4, polar compounds. Fractions F1 and F2 were further investigated using gas chromatography, and all fractions were characterized by CHN analysis, confirming the increase of aromatics in the fractions 2, 3, 4 and asphaltenes. For the determination of Ni and V by ET AAS, oil-in-water emulsions were prepared. The speciation analysis was carried out measuring without chemical modifier (stable compounds) and with 20 μg palladium (total Ni and V) and the volatile fraction was calculated by difference. The limits of detection were 0.02 μg g−1 and 0.06 μg g−1, for Ni and V, respectively, based on an emulsion of 2 g of oil in 10 mL. The volatile species of Ni and V were associated with fractions F3 and F4, while only thermally stable Ni and V was precipitated in part together with the asphaltenes.  相似文献   

19.
Analytical procedures have been developed for the reliable determination of 19 trace elements (Ag, Al, Ba, Bi, Cd, Co, Cr, Cu, Fe, Mn, Pb, Rb, Sb, Sc, Sr, Tl, U, V, Zn) in ice samples at pg g−1 and fg g−1 concentrations using ICP-sector field mass spectrometry (ICP-SMS). Concentrations of most elements in the high purity water and doubly distilled HNO3 employed were distinctly lower than previously reported values. The accuracy of the results was carefully evaluated using the certified water reference material SLRS-4. Contributions of unwanted trace elements due to acidification of the ice samples (0.5% HNO3) to the total element budget amounted to only 0.001 pg g−1 for Bi, 0.34 pg g−1 for Cr, 0.2 pg g−1 for Fe, 0.004 pg g−1 for Pb, 0.00015 pg g−1 for U and 0.0025 pg g−1 for V: compared to the concentrations of the metals in ice these are negligible. The use of a detergent (0.05%) in the rinsing solution (0.5% HNO3), helped to reduce memory effects by 59–98%, depending on the element considered; this resulted in shorter washing times between samples (i.e. 1 min) and improved analysis time. Adopting strict clean room procedures, the detection limit for Pb (0.06 pg g−1) is a factor of ten lower than the current state-of-the-art. Compared to previous studies, the improved LODs obtained here for other trace elements amount to 2× (Ag), 4× (Sb), 5× (Ba), 6× (Cu, Mn, U), 9× (Bi), 13× (Cd), 18× (Fe) and 21× (V). The developed analytical protocols were successfully applied to the determination of selected trace elements in age-dated ice samples from the Canadian High Arctic. The toxic trace element Tl (median: 0.16 pg g−1; range: 0.03–1.32 pg g−1) and the lithogenic reference element Sc (0.53 pg g−1; 0.06–2.9 pg g−1) have been determined in a polar ice core for the first time.  相似文献   

20.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号