首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A simple and rapid gas chromatography/mass spectrometry (GC/MS) analysis method was developed for the determination of essential oils in the crude extract of Schizonepeta tenuifolia Briq (Sch.t.Briq). Five major volatiles (menthone, pulegone, 2-hydroxy-2-isopropenyl-5-methylcylohexanone, cis-pulegone oxide, and schizonal) were extracted and isolated from Sch.t.Briq as marker compounds for use in the quality control of herbal medicines. Various extraction techniques, such as solvent immersion, mechanical shaking, and sonication, were evaluated, and the greatest efficiency was observed with sonication extraction using petroleum ether. The dynamic range of the GC/MS method depended on the specific analyte; acceptable quantification was obtained between 10 and 1000 μg/mL for menthone and pulegone, and between 2.5 and 75.0 μg/mL for 2-hydroxy-2-isopropenyl-5-methylcylohexanone, cis-pulegone oxide, and schizonal. The method was deemed satisfactory by inter- and intra-day validation and exhibited both high accuracy and precision, with a relative standard deviation < 10%. Overall limits of detection were approximately 0.40–0.50 μg/mL, with a standard deviation (σ)-to-calibration slope (s) ratio (σ/s) of 3. The limit of quantitation in our experiments was approximately 2.5 μg/mL at a σ/s of 10. On the basement of method validation, 21 samples of Sch.t.Briq collected from markets in Korea were monitored for the quality control. In addition, principal component analysis (PCA) and hierarchical cluster analysis (HCA) were performed on the analytical data of 21 different Sch.t.Briq samples in order to classify samples that were collected from different regions.  相似文献   

2.
Air in a room infested by Cimex lectularius L. (Hemiptera: Cimicidae) was sampled simultaneously by three different sampling devices including solid phase microextraction (SPME) fiber coatings, thin film microextraction (TFME) devices, and needle trap devices (NTDs) and then analyzed by gas chromatography–mass spectrometry (GC–MS). The main focus of this study was to fully characterize indoor air by identifying compounds extracted by three different microextraction formats and, therefore, perform both the device comparison and more complete characterization of C. lectularius pheromone. The NTD technique was capable of extracting both (E)-2-hexenal and (E)-2-octenal, which were previously identified as alarm pheromones of bedbugs, and superior NTD recoveries for these two components allowed reliable identification based on mass spectral library searching and linear temperature programmed retention index (LTPRI) technique. While the use of DVB/CAR/PDMS SPME fiber coatings provided complementary sample fingerprinting and profiling results, TFME sampling devices provided discriminative extraction coverage toward highly volatile analytes. In addition to two alarm pheromones, relative abundances of all other analytes were recorded for all three devices and aligned across all examined samples, namely, highly infested area, less infested area, and control samples which were characterized by different bedbug populations. The results presented in the current study illustrate comprehensive characterization of infested indoor air samples through the use of three different non-invasive SPME formats and identification of novel components comprising C. lectularius pheromone, therefore, promising future alternatives for use of potential synthetic pheromones for detection of infestations.  相似文献   

3.
A rapid method for detection of Salmonella typhimurium contamination in packaged alfalfa sprouts using solid phase microextraction/gas chromatography/mass spectrometry (SPME/GC/MS) integrated with chemometrics was investigated. Alfalfa sprouts were inoculated with S. typhimurium, packed into commercial LDPE bags and stored at 10 + 2 °C for 0, 1, 2 and 3 days. Uninoculated sprouts were used as control samples. A SPME device was used to collect the volatiles from the headspace above the samples and the volatiles were identified using GC/MS. Chemometric techniques including linear discriminant analysis (LDA) and artificial neural network (ANN) were used as data processing tools. Numbers of Salmonella were followed using a colony counting method. From LDA, it was able to differentiate control samples from sprouts contaminated with S. typhimurium. The potential to predict the number of contaminated S. typhimurium from the SPME/GC/MS data was investigated using multilayer perceptron (MLP) neural network with back propagation training. The MLP comprised an input layer, one hidden layer, and an output layer, with a hyperbolic tangent sigmoidal transfer function in the hidden layer and a linear transfer function in the output layer. The MLP neural network with a back propagation algorithm could predict number of S. typhimurium in unknown samples using the volatile fingerprints. Good prediction was found as measured by a regression coefficient (R2 = 0.99) between actual and predicted data.  相似文献   

4.
Various sampling techniques including flash evaporation (FE), headspace solid-phase microextraction (HS-SPME) and steam distillation (SD) were compared for the gas chromatography-mass spectrometry of volatile constituents present in Houttuynia cordata Thunb (HCT). 2-Undecanone (22.21%) and houttuynum (7.23%) were predominant components of HCT samples obtained by HS-SPME whereas those levels were 3.95 and 3.60% in the same samples by FE and 25.93 and 6.60% in those by SD, respectively. SPME with polydimethylsiloxane (PDMS) fibre was more selective and particularly efficient for the isolation of biologically active compounds and afforded a higher yield of total compounds than FE and SD. A total of 60 compounds were detected in SPME extracts. While in FE and SD extracts, the detected compounds were 41 and 51, respectively. The total amount of compounds isolated by SPME was much larger than that isolated by FE or SD. Some minor constituents were isolated by SPME, but not by SD and FE. This carries great significance because of the importance of the oil volatiles to clinical therapy. HS-SPME is a powerful tool for determining the volatile constitutes present in the TCMs.  相似文献   

5.
Dynamic headspace solid-phase microextraction (HS-SPME) followed by thermal desorption gas chromatography-quadrupole mass spectrometry analysis (GC-qMS), was used to investigate the aroma profile of different species of passion fruit samples. The performance of five commercially available SPME fibres: 65 μm polydimethylsiloxane/divinylbenzene, PDMS/DVB; 100 μm polydimethylsiloxane, PDMS; 85 μm polyacrylate, PA; 50/30 μm divinylbenzene/carboxen on polydimethylsiloxane, DVB/CAR/PDMS (StableFlex); and 75 μm carboxen/polydimethylsiloxane, CAR/PDMS; was evaluated and compared. Several extraction times and temperature conditions were also tested to achieve optimum recovery. The SPME fibre coated with 65 μm PDMS/DVB afforded the highest extraction efficiency, when the samples were extracted at 50 °C for 40 min with a constant stirring velocity of 750 rpm, after saturating the sample with NaCl (17%, w/v — 0.2 g). A comparison among different passion fruit species has been established in terms of qualitative and semi-quantitative differences in volatile composition. By using the optimal extraction conditions and GC-qMS it was possible to tentatively identify seventy one different compounds in Passiflora species: 51 volatiles in Passiflora edulis Sims (purple passion fruit), 24 in P. edulis Sims f. flavicarpa (yellow passion fruit) and 21 compounds in Passiflora mollissima (banana passion fruit). It was found that the ethyl esters comprise the largest class of the passion fruit volatiles, including 82.8% in P. edulis variety, 77.4% in P. edulis Sims f. flavicarpa variety and 39.9% in P. mollissima.The semi-quantitative results were then submitted to principal component analysis (PCA) in order to establish relationships between the compounds and the different passion fruit species under investigation.  相似文献   

6.
A rapid headspace single-drop micro-extraction(mix) gas chromatography mass spectrometry(SDMEGC -MS) for the analysis of the volatile compounds in Herba Asari was developed in this study.A mixed solvent of n-tridecane and butyl acetate(1:1) was finally used for the extraction at 70 C for 15 min with sample amount of 0.750 g and 100 mesh particle size.Under the determined conditions,the pound samples of Herba Asari were directly applied for the analysis.SDME-GC-MS,SPME-GC-MS and SD-GCMS methods were compared and the results showed that SDME-GC-MS method was a simple, inexpensive and effective way to measure the volatile compounds in Herba Asari and could be used for the analysis of volatile compounds in complex samples.  相似文献   

7.
Solid-phase microextraction (SPME) followed by gas chromatography/mass spectrometry (GC/MS) was used for the detection of liver cancer volatile biomarkers. Headspace SPME conditions (fiber coating, extraction temperature and extraction time) and desorption conditions were optimized and applied to the determination of volatiles in human blood. Between the liver cancer group (n = 19) and the normal group (n = 18), positive rates of 19 volatile compounds among the total of 47 detected were found to be different with statistical significance (p < 0.05, chi-squared test). We suggested hexanal, 1-octen-3-ol and octane, of the 19 compounds, as biomarkers of liver cancer with clinical diagnostic value. The sensitivity and specificity of 94.7% and 100% for hexanal, 84.2% and 100% for 1-octen-3-ol, and 89.5% and 100% for octane were obtained, respectively, after the cutoff values had been properly established. These results show that SPME-GC/MS is a simple, rapid and sensitive method for the investigation of volatile disease markers in human blood.  相似文献   

8.
In this study, the feasibility of GC–MS was evaluated for the quantification of odorous volatile organic compounds (VOCs) in environmental samples. These included methyl ethyl ketone, isobutyl alcohol, methyl isobutyl ketone, and butyl acetate plus benzene, toluene, and xylene (BTX). For this purpose, the gaseous standard for these VOCs were analyzed by GC–MS with the aid of both direct injection (DI) into the GC injector and solid-phase microextraction (SPME). The liquid phase standard prepared independently was tested additionally by the DI method as a reference to gaseous calibration. The detection limit (DL) values, when tested for basic quality assurance in this study, showed large differences between DI (0.002–0.007 ng) and SPME method (1.03–1.81 ng) in terms of absolute mass. The DL values, when expressed in terms of concentration (v/v), showed considerable improvement in SPME (below 0.40 nmol mol−1) relative to the DI method (∼6–15 nmol mol−1). The reliability of the GC–MS method was further validated through an analysis of real environmental samples collected from an industrial area.  相似文献   

9.
As a very popular sample preparation technique, solid-phase microextraction (SPME) coupled with various analytical instrumentation, has been widely used for the determination of trace levels of different plant compounds, such as volatile organic compounds (VOCs) emitted from the different plant organs, and environmental contaminants in plants. In this review, recent applications of in vitro and in vivo SPME in plant analysis are discussed and summarized according to the different organs of plants, including fruits, flowers, leaves, stems, roots and seeds, and the whole plant as well. Future developments and applications of SPME in plant analysis, especially in vivo sampling approaches, are also prospected.  相似文献   

10.
A new molecularly imprinted polymer modified with restricted access material (a hydrophilic external layer), (MIP-RAM) was synthesized via polymerization in situ in an open fused silica capillary. This stationary phase was used as sorbent for in-tube solid phase microextraction (in-tube SPME) to determine parabens in breast milk samples by ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). Scanning electron micrographs (SEM) illustrate MIP surface modification after glycerol dimethacrylate (hydrophilic monomer) incorporation. The interaction between parabens and MIP-RAM was investigated by Fourier-transform infrared (FTIR) spectroscopy. The Scatchard plot for MIP-RAM presented two linear parts with different slopes, illustrating binding sites with high- and low-affinity. Endogenous compounds exclusion from the MIP-RAM capillary was demonstrated by in-tube SPME/LC-UV assays carried out with blank milk samples. The in-tube SPME/UHPLC-MS/MS method presented linear range from 10 ng mL−1 (LLOQ) to 400 ng mL−1 with coefficients of determination higher than 0.99, inter-assay precision with coefficient of variation (CV) values ranging from 2 to 15%, and inter-assay accuracy with relative standard deviation (RSD) values ranging from −1% to 19%. Analytical validation parameters attested that in-tube SPME/UHPLC-MS/MS is an appropriate method to determine parabens in human milk samples to assess human exposure to these compounds. Analysis of breast milk samples from lactating women demonstrated that the proposed method is effective.  相似文献   

11.
We have developed a simple and sensitive method for the simultaneous determination of testosterone (TES), cortisol (CRT), and dehydroepiandrosterone (DHEA) in saliva by automated online in-tube solid-phase microextraction (SPME) coupled with liquid chromatography–tandem mass spectrometry (LC–MS/MS) using a Discovery HS F5 column. The optimum in-tube SPME conditions were 25 draw/eject cycles of 40 μL of sample at a flow rate of 200 μL/min using a Supel-Q PLOT capillary column as an extraction device. The extracted compounds were easily desorbed from the capillary by passage of the mobile phase, and no carryover was observed. The in-tube SPME LC–MS/MS method showed good linearity with correlation coefficients r?≥?0.9998 for TES, CRT, and DHEA using their respective stable isotope-labeled internal standards. The intra-day and inter-day precisions (relative standard deviations) were below 4.9 and 8.5 % (n?=?5), respectively. This method was successfully utilized to analyze TES, CRT, and DHEA in saliva samples without any other pretreatment or interference peaks, and the quantification limits (S/N?=?10) of TES, CRT and DHEA were about 0.01, 0.03 and 0.29 ng/mL saliva, respectively. The recoveries of these compounds spiked into saliva samples were each above 94 %. This method was applied to analyze changes in salivary TES, CRT, and DHEA levels resulting from stress and fatigue load.  相似文献   

12.
The use of two modes for mass spectrometry (MS) detection with an ion trap instrument, selected ion storage (SIS) and tandem mass spectrometry (MS/MS), are compared for the solid-phase microextraction (SPME)–gas chromatography (GC) coupled to mass spectrometry (GC-MS) determination of 16 priority organochlorine pesticides (OCPs) in drinking water samples at the ultratrace levels (ng?L?1) required by official guidelines in the European legislation. Experimental parameters investigated for the SPME sample preparation were: the type of coating (100?µm polydimethylsiloxane, PDMS, and 65?µm poly(dimethylsiloxane)–divinylbenzene, PDMS/DVB), SPME modality, extraction and desorption times and desorption temperature and the methanol percentage in the SPME working solution. Under the calculated optimal conditions two methodologies were developed, one for SIS and the other for MS/MS modes. The detection limits, precision and accuracy were evaluated for both alternatives and were appropriate to the official guidelines requirements. The SPME–GC-MS(SIS) methodology offered LODs from 0.2–6.6?ng?L?1, precision below 13% and recoveries between 83 and 110%. The SPME–GC–MS/MS methodology provided limits of detection (LODs) ranging from 0.3 to 7.6 ng?L?1, % RSD were ≤14% and recoveries of 79–108% were achieved. After the results observed within an Interlaboratory Exercise, the latest MS methodology was selected for the pursued analysis in real drinking water samples. Also, the good results in this round-robin exercise validate the proposed SPME–GC–MS/MS methodology.  相似文献   

13.
A headspace SPME GC-TOF-MS method was developed for the acquisition of metabolite profiles of apple volatiles. As a first step, an experimental design was applied to find out the most appropriate conditions for the extraction of apple volatile compounds by SPME. The selected SPME method was applied in profiling of four different apple varieties by GC-EI-TOF-MS. Full scan GC-MS data were processed by MarkerLynx software for peak picking, normalisation, alignment and feature extraction. Advanced chemometric/statistical techniques (PCA and PLS-DA) were used to explore data and extract useful information. Characteristic markers of each variety were successively identified using the NIST library thus providing useful information for variety classification. The developed HS-SPME sampling method is fully automated and proved useful in obtaining the fingerprint of the volatile content of the fruit. The described analytical protocol can aid in further studies of the apple metabolome.  相似文献   

14.
The aim of the study was determination of bacterial viability in saliva samples and finding a correlation between microbiological and volatile profiles of saliva depending on incubation time. Bacteria colonizing healthy oral cavities were also identified. Twelve healthy adults donated unstimulated saliva samples. Flow cytometry, optical density measurements and colony‐forming unit (CFU) counting method were employed for analyses of native and inoculated saliva after 0, 1, 2, 24, and 48 h of incubation. Volatile profiles were acquired using headspace‐solid phase microextraction‐gas chromatography/mass spectrometry (HS‐SPME‐GC/MS). Oral bacteria were the most viable within 2 h after collection of saliva. Extension of incubation time to 48 h caused considerable decrease in live bacteria counts and sharp increase in dead bacteria counts. The most prevalent strain was Sphingomonas paucimobilis (26.67%). The number of volatiles raised from 5 to 27 with incubation time and most of them were putrefaction products, such as methanethiol, indole and pyrrole. HS‐SPME‐GC/MS method is insufficient for volatile profiling of “fresh” saliva and should be directed rather to investigation of bacterial metabolites.  相似文献   

15.
As the distribution center of Rosa in the world, China has abundant wild germplasm resources, which can contribute to the breeding of modern roses. To explore the potential value of wild roses distributed in the Sichuan–Tibet region, solid phase microextraction (SPME) and gas chromatography–mass spectrometry (GC–MS) were used to determine the volatile organic compounds (VOCs) in Rosa willmottiae flowers at three flowering stages (bud stage, initial flowering stage, full flowering stage). Meanwhile, we compared the VOCs of R. willmottiae with different phenotypes (double flowers and single flowers). A total of 74 volatile compounds were identified. The results show that the essential substances belong to alcohols and terpenoids. The main volatile organic compounds are 2-phenyl ethanol (20.49%), benzyl alcohol (10.69%), β-maaliene (8.66%), geranyl acetate (8.47%), and (+)-α-long pinene (6.127%). Different flowering stages had great influence on the volatile profile, from the bud stage to full flowering stage; the content of terpenoids released decreased by 6.17%, whereas alcohols and esters increased by 8.58% and 11.56%, respectively. The chemical diversity and the content of the main components with a different phenotype were not significantly different. Our result will provide a theoretical basis for the development and utilization of Rosa willmottiae in Sichuan and Tibet.  相似文献   

16.
Two analytical procedures, one based on purge-and-trap and the other on solid phase microextraction, both followed by GC–MS measurement using an ion-trap mass spectrometer in the electron impact mode, have been developed for determination and quantitation of up to 39 aroma compounds in fresh tomatoes. The method based on purge-and-trap for isolation of the volatile compounds uses Tenax as adsorbent and a hexane–diethyl ether mixture as solvent for elution. The method was validated for linearity, precision (better than 20% for most compounds), and limit of detection, which was approximately 1 ng g−1. This method enabled identification of up to 30 compounds in real samples. Use of SPME was considered as an alternative, to simplify sample treatment while maintaining the information level for the samples (e.g. the number of compounds detected) and quality of quantitation. A procedure based on SPME using a Carboxen/polydimethylsiloxane fibre was developed and validated for determination of 29 aroma compounds; precision was better than 20% and limits of detection ranged from 4 to 30 ng g−1.  相似文献   

17.
The use of solid-phase microextraction (SPME) for in vivo sampling of drugs and metabolites in the bloodstream of freely moving animals eliminates the need for blood withdrawal in order to generate pharmacokinetics (PK) profiles in support of pharmaceutical drug discovery studies. In this study, SPME was applied for in vivo sampling in mice for the first time and enables the use of a single animal to construct the entire PK profile. In vivo SPME sampling procedure used commercial prototype single-use in vivo SPME probes with a biocompatible extractive coating and a polyurethane sampling interface designed to facilitate repeated sampling from the same animal. Pre-equilibrium in vivo SPME sampling, kinetic on-fibre standardization calibration and liquid chromatography–tandem mass spectrometry analysis (LC–MS/MS) were used to determine unbound and total circulating concentrations of carbamazepine (CBZ) and its active metabolite carbamazepine-10,11-epoxide (CBZEP) in mice (n = 7) after 2 mg/kg intravenous dosing. The method was linear in the range of 1–2000 ng/mL CBZ in whole blood with acceptable accuracy (93–97%) and precision (<17% RSD). The single dose PK results obtained using in vivo SPME sampling compare well to results obtained by serial automated blood sampling as well as by the more conventional method of terminal blood collection from multiple animals/time point. In vivo SPME offers the advantages of serial and repeated sampling from the same animal, speed, improved sample clean-up, decreased animal use and the ability to obtain both free and total drug concentrations from the same experiment.  相似文献   

18.
A method for determining the volatile organic compounds (VOCs) in textiles was developed, by the use of high capacity headspace, solid phase micro extraction (SPME) and gas chromatography–mass spectrometry (GC/MS). The detection targets contained total organic compounds (TVOCs) and six specific substances (toluene, vinylcyclohexene, styrene, 4-phenylcyclohexene, vinylchloride and butadiene), according to Oeko-Tex Standard 100. A designed experiment was used to optimize the headspace–SPME–GC/MS operation, and the method was validated in terms of linearity, limit of detection (LOD) and method precision. It was found that at a loading ratio of 10 m2/m3, the LODs for toluene, vinylcyclohexene, styrene and 4-phenylcyclohexene were 0.0002 mg/m2, 0.01 mg/m2, 0.01 mg/m2 and 0.0001 mg/m2 respectively, while for vinylchloride and butadiene they were both 0.08 mg/m2. SPME exhibited better adsorption performance for toluene, vinylcyclohexene, styrene and 4-phenylcyclohexene, for which the extraction fractions were 10 times of those for vinylchloride and butadiene. The method developed was successfully applied to analyze several commercial textiles, and would be a simple, efficient and promising technique for the analysis of volatile compounds from textiles or other samples (such as polymer materials).  相似文献   

19.
Liseth Ferreira 《Talanta》2009,77(3):1087-1096
The analysis of volatile compounds in Funchal, Madeira, Mateus and Perry Vidal cultivars of Annona cherimola Mill. (cherimoya) was carried out by headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-quadrupole mass spectrometry detection (GC-qMSD). HS-SPME technique was optimized in terms of fibre selection, extraction time, extraction temperature and sample amount to reach the best extraction efficiency. The best result was obtained with 2 g of sample, using a divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fibre for 30 min at 30 °C under constant magnetic stirring (800 rpm).After optimization of the extraction methodology, all the cherimoya samples were analysed with the best conditions that allowed to identify about 60 volatile compounds. The major compounds identified in the four cherimoya cultivars were methyl butanoate, butyl butanoate, 3-methylbutyl butanoate, 3-methylbutyl 3-methylbutanoate and 5-hydroxymethyl-2-furfural. These compounds represent 69.08 ± 5.22%, 56.56 ± 15.36%, 56.69 ± 9.28% and 71.82 ± 1.29% of the total volatiles for Funchal, Madeira, Mateus and Perry Vidal cultivars, respectively. This study showed that each cherimoya cultivars have 40 common compounds, corresponding to different chemical families, namely terpenes, esters, alcohols, fatty acids and carbonyl compounds and using PCA, the volatile composition in terms of average peak areas, provided a suitable tool to differentiate among the cherimoya cultivars.  相似文献   

20.
固相微萃取-气相色谱/质谱测定植物叶片中的挥发性物质   总被引:2,自引:0,他引:2  
王明林  乔鲁芹  张莉  吴烈钧  田洪孝 《色谱》2006,24(4):343-346
采用固相微萃取(SPME)方法吸附植物叶片中的挥发性物质,然后采用气相色谱/质谱法(GC/MS)分析了挥发性物 质的成分。在45 ℃水浴温度下,采用Polyacrylate(85 μm)固相微萃取头,在广口瓶中植物叶片的上方顶空吸附60 min,然后进行GC/MS分析。结果表明,植物叶片中的挥发性物质得到了很好的分离,受山楂叶螨(Tetraychus vienneis) 危害严重的植物的完好叶片中的挥发性物质均含有顺-3-己烯-1-醇乙酸酯、顺-3-己烯-1-醇丁酸酯和α-法呢烯,且含量 较大。初步确定这些物质是对山楂叶螨具有引诱作用的主要物质,从而为利用天然生物活性物质防治山楂叶螨提供了理论 依据。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号