首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
In this study, a three-phase hollow fiber liquid-phase microextraction (HF-LPME) method combined with liquid chromatography–mass spectrometry was developed for direct determination of four non-steroidal anti-inflammatory drugs (ketoprofen, naproxen, diclofenac and ibuprofen) in sewage sludge. The drugs were extracted from non-spiked and spiked slurry samples with different amounts of sludge into an organic phase and then back-extracted into an aqueous phase held in the lumen of the hollow fiber. High enrichment factors ranging from 2761 to 3254 in pure water were achieved. In sludge samples, repeatability and inter-day precision were tested with relative standard deviation values between 10–18% and 7–15%, respectively. Average concentrations of 29 ± 9, 138 ± 2, 39 ± 5 and 122 ± 7 ng/g were determined in dried sludge from Källby sewage treatment plant (Sweden) for ketoprofen, naproxen, diclofenac and ibuprofen, respectively.  相似文献   

2.
Investigations were performed along the Danube river at Budapest (Hungary) by collecting water and sediment samples simultaneously for 1 year in order to clarify the possible hazard of selected acidic pharmaceuticals (ibuprofen, naproxen, ketoprofen, and diclofenac) on the water supply used for the production of drinking water by bank filtration. In the case of water samples, the sample preparation procedure included solid phase extraction (SPE), meanwhile, in the case of sediment samples, microwave-assisted extraction (MAE) followed by dispersive matrix extraction (DME) for pre-cleaning as well as SPE for enrichment. The quantification was carried out using gas chromatography–mass spectrometry (GC–MS). The calculated recoveries were 97–99% (± 7%) for the water and 95–103% (± 12%) for the sediment samples. In the river water, ketoprofen concentration was always below the limit of quantification (LOQ) level; ibuprofen, naproxen and diclofenac could be quantified in the range of 8–50, 2–30, 7–90 ng/L. In sediments, only naproxen and diclofenac were found in the range of 2–20 and 5–38 ng/g, respectively. According to the obtained results, the concentration ratios of the two phases linearly depended on the total organic carbon content (TOC) of the sediments at each sampling date. The linear regressions were 0.925 and 0.946 for naproxen and diclofenac, respectively.  相似文献   

3.
A novel multi-templates molecularly imprinted polymer (MIP), using acidic pharmaceuticals mixture (ibuprofen (IBP), naproxen (NPX), ketoprofen (KEP), diclofenac (DFC), and clofibric acid (CA)) as the template, was prepared as solid-phase extraction (SPE) material for the quantitative enrichment of acidic pharmaceuticals in environmental samples and off-line coupled with liquid chromatography–mass spectrometry (LC/MS/MS). Washing solvent was optimized in terms of kind and volume for removing the matrix constituents nonspecifically adsorbed on the MIP. When 1 L of water sample spiked at 1 μg/L was loaded onto the cartridge, the binding capacity of the MIP cartridge were 48.7 μg/g for KEP, 60.7 μg/g for NPX, 52 μg/g for CA, 61.3 μg/g for DFC and 60.7 μg/g for IBP, respectively, which are higher than those of the commercial single template MIP in organic medium (e.g. toluene) reported in the literature. Recoveries of the five acidic pharmaceuticals extracted from 1 L of real water samples such as lake water and wastewater spiked at 1 μg/L were more than 95%. The recoveries of acidic pharmaceuticals extracted from 10-g sediment sample spiked at the 10 ng/g level were in the range of 77.4–90.6%. To demonstrate the potential of the MIP obtained, a comparison with commercial C18 SPE cartridge was performed. Molecularly imprinted solid-phase extraction (MISPE) cartridge showed higher recoveries than commercial C18 SPE cartridge for acidic pharmaceuticals. These results showed the suitability of the MISPE method for the selective extraction of a group of structurally related compounds such as acidic pharmaceuticals.  相似文献   

4.
A procedure is described for the determination of five acidic non-steroidal anti-inflammatory pharmaceuticals (ibuprofen, naproxen, ketoprofen, tolfenamic acid and diclofenac) in sewage water. The analytical method involves the concentration of water samples using a solid-phase extraction polymeric sorbent, functionalized with N-vinylpyrrolidone. Analytes were eluted with ethyl acetate. derivatized using N-methyl-N-(tert.-butyldimethylsilyl)trifluoroacetamide (MTBSTFA) and analyzed by GC-MS. Influence of time, temperature and volume of MTBSTFA in the yield of the derivatization step were studied in detail using a factorial central composite design. Quantification limits of the analytical procedure for 500 ml of sewage water ranged from 20 to 50 ng/l. Recoveries from 90 to 115% were found for sewage water samples spiked with the studied compounds at the low ng/ml level. Results obtained for real samples show the presence of ibuprofen and naproxen in both influent and effluent of a sewage water treatment plant.  相似文献   

5.
Yu Y  Wu L 《Journal of chromatography. A》2011,1218(18):2483-2489
As one category of the most urgent emerging pollutants, pharmaceuticals have provoked much public and scientific attention due to widespread contamination in aquatic environment. In this study, two active methods by Oasis HLB and MCX and two passive methods by XAD-16 and XAD-16/7 were evaluated for determining the concentrations of 10 pharmaceuticals (carbamazepine, clofibric acid, diclofenac, gemfibrozil, ibuprofen, ketoprofen, naproxen, paracetomol, terbutaline and triclosan) in reclaimed wastewater. Recoveries of the target pharmaceuticals extracted by MCX were higher than HLB except for diclofenac and ketoprofen. For the passive methods, the addition of polar resin XAD-7 improved the recovery compared with the addition of XAD-16 only. The mean recoveries of the target analytes by XAD-16/7 ranged from 22 to 75.8%. The limit of quantification (LOQ) ranged between 25 and 280 ng/L. In addition, by comparing the accuracy and precision of XAD-16/7 method and MCX method, we further demonstrated that the XAD-16/7 method can be satisfactorily used for the analysis of pharmaceuticals in wastewater samples. We applied the method to some wastewater samples from sewage treatment plant (STP) nearby Riverside, CA to track the concentration change of pharmaceuticals in the treatment processes. The result shown that pharmaceuticals were effective reduced in STP mostly by activated sludge.  相似文献   

6.
Pharmaceuticals are released to the environment after human and animal consumption, which partly comes from accumulation in sewage sludge during wastewater treatment. This paper developed a method for the determination of N,N-diethyl-meta-toluamide (DEET) and 14 pharmaceuticals belonging to multiple therapeutic classes such as antibiotic, anti-inflammatory, antilipidemic, anti-hypertensive, and anticonvulsant in dewatered sludge. Pressurized liquid extraction using methanol/McIlvaine buffer (volume ratio, 1?:?1), associated with HPLC-MS/MS was proven to be effective for extraction and quantification of pharmaceuticals and DEET in dewatered sludge. Optimization procedures, including extraction method, extraction solvents and clean-up treatment, were carried out by simulating naturally aged samples to provide a more realistic extraction than previous methods, which were often done by spiking the standard solution before extraction without any aging procedures. The internal standard quantification method using six isotopically labelled compounds was applied to improve the poor absolute recoveries induced by severe matrix effects to obtain better relative recoveries (70–120%). Good relative standard deviations (lower than 19.0% for 7 repeats) and the limit of quantification (0.6–19.4?µg/kg) indicated that the developed method was reliable and sensitive to extract and quantify the studied pharmaceuticals in dewatered sludge. For samples collected from eight sewage treatment plants in Beijing, China, it was found that trimethoprim, caffeine, ketoprofen and ibuprofen were the most prominent contaminants, with the median concentrations reaching 97.6, 179.4, 268.0 and 153.0?µg/kg, respectively. The level of ketoprofen, ibuprofen, mefenamic acid, cabamazepine and diclofenac were similar to results reported from Spain, whilst the levels of other compounds were similar to those found in Germany, Canada and the US.  相似文献   

7.
In the present work, an analytical method for the simultaneous determination of five anti-inflammatory drugs (acetaminophen, diclofenac, ibuprofen, ketoprofen and naproxen), an antiepileptic drug (carbamazepine) and a nervous stimulant (caffeine) is proposed for the routine analysis of these pharmaceuticals in wastewater influents and effluents from WWTPs. The method involves pre-concentration and clean-up by solid phase extraction (SPE) using Oasis HLB extraction cartridges. Final analysis of the selected pharmaceutical compounds was carried out by high-performance liquid chromatography (HPLC) with diode array detector (DAD). Confirmation of the presence of the fluorescence compounds (ibuprofen and naproxen) was performed by on-line fluorescence detection. Recoveries were ranged from 71 to 103% with relative standard deviation below 15.1%. Limits of quantification were in the range 6.2–319.8 and 3.0–160.0 ng ml−1 for influent and effluent wastewater samples, respectively. The described method was applied to the determination of the drugs in wastewater samples from four treatment plants in Seville.  相似文献   

8.
In this study, we aimed at optimizing a sensitive and reliable method for a simultaneous determination of 31 pharmaceuticals belonging to predominant therapeutic classes identified in different types of sewage sludge proceeding from conventional and advanced wastewater treatment. Freeze-dried sewage sludge was extracted by pressurized liquid extraction technique using accelerated solvent extractor Dionex 300. In order to minimize interferences with matrix components and to preconcentrate target analytes, solid phase extraction was introduced in the method as a clean-up step. The entire method was validated for linearity, precision, accuracy, and method detection limits (MDLs). The method turned out to be specific, sensitive, and reliable for the analysis of sludge of different composition, type, and retention time in the process. The developed sample preparation protocol and previously published method for LC-MS/MS analysis (Gros et al., Talanta 70:678–690, 2006) were successfully applied to monitor the target pharmaceuticals in different types of sewage sludge, i.e., primary sludge, secondary sludge, treated sludge, and sludge proceeding from pilot-scale membrane bioreactors (MBRs) operating in parallel to the conventional activated sludge treatment. Among the investigated pharmaceuticals, 20 were detected in the sludge proceeding from full-scale installations, whereas the MBR sludge concentrations were below MDLs for several compounds. The highest concentrations were recorded for treated and primary sludge. For example, the mean concentration of ibuprofen in the digested sludge was 299.3?±?70.9 ng g?1 dw, whereas in the primary sludge, it was enriched up to 741.1 ng g?1 dw. Other pharmaceuticals detected at relatively high concentrations were diclofenac, erythromycin, glibenclamide, ketoprofen, ofloxacin, azithromycin (up to 380.7, 164.2, 190.7, 336.3, 454.7, 299.6 ng g?1 dw in the primary sludge, respectively), gemfibrozil, loratidine, and fluoxetine (up to 189.1, 189.7 and 174.1 ng g?1 dw in the treated sludge, respectively).  相似文献   

9.
Dispersive liquid–liquid microextraction (DLLME) coupled with liquid chromatography-tandem mass spectrometry detection was applied for determination of selected anti-inflammatory pharmaceuticals: ibuprofen, ketoprofen, naproxen and diclofenac. Development of DLLME procedure included optimisation of several important parameters such as kind and volume of extracting and dispersive solvents as well as sample pH. Under optimised conditions a two-step extraction with sonication was used. Chloroform was applied as the extracting and acetone as dispersing solvent. Calibration curves ranges were 1–500 μg L?1 for naproxen and ibuprofen and 0.25–500 μg L?1 for ketoprofen and diclofenac with correlation coefficients at least 0.997. Limits of quantitation were from 0.5 to 10 ng L?1. The developed analytical method was employed for determination of ibubrofen, ketoprofen, naproxen and diclofenac in river and tap water samples. The results showed that DLLME is a simple, rapid and sensitive analytical technique for the pre-concentration of trace amounts of pharmaceuticals in environmental water samples.  相似文献   

10.

Five acidic drugs (clofibric acid, ibuprofen, ketoprofen, mefenamic acid and diclofenac) were chosen in order to determine their behavior in a sewage treatment plant (STP). An analytical method using solid phase extraction (SPE) and a gas chromatograph coupled with a mass spectrometer (GC-MS) was used. The results show that four pharmaceuticals (clofibric acid, ketoprofen, mefenamic acid and diclofenac) are not well removed by treatment in Swiss STPs. Maximum concentration in the effluent was determined for mefenamic acid up to 1.0 µg/L. This component seems to be relevant in Swiss STPs effluents and we can expect its presence in surface waters.  相似文献   

11.
In this paper, an electromembrane extraction (EME) combined with a HPLC procedure using diode array (DAD) and fluorescence detection (FLD) has been developed for the determination of six widely used non-steroidal anti-inflammatory drugs (NSAIDs): salicylic acid (SAC), ketorolac (KTR), ketoprofen (KTP), naproxen (NAX), diclofenac (DIC) and ibuprofen (IBU). The drugs were extracted from basic aqueous sample solutions, through a supported liquid membrane (SLM) consisting of 1-octanol impregnated in the walls of a S6/2 Accurel® polypropylene hollow fiber, and into a basic aqueous acceptor solution resent inside the lumen of the hollow fiber with a potential difference of 10 V applied over the SLM. Extractions that were carried out in 10 min using a potential of 10 V from pH 12 NaOH aqueous solutions shown concentration enrichments factors of 28-49 in a pH 12 NaOH aqueous acceptor solution. The proposed method was successfully applied to urban wastewaters. Excellent selectivity was demonstrated as no interfering peaks were detected. The procedure allows very low detection and quantitation limits of 0.0009-9.0 and 0.003-11.1 μg L−1, respectively.  相似文献   

12.
A simple and specific analytical method was developed and tested for the determination of pharmaceuticals in mollusc samples. A combination of microwave-assisted micellar extraction (MAME) and solid-phase extraction (SPE) using a non-ionic surfactant, polyoxyethylene 10 lauryl ether, was examined to extract and determine simultaneously a group of pharmaceuticals such as carbamazepine, clorfibric acid, ketoprofen, naproxen, bezafibrate and ibuprofen by liquid chromatography using UV-diode array detector. The MAME extraction performance was evaluated by studying various parameters such as the volume and concentration of surfactant and microwave conditions. Finally, an OASIS HLB cartridge was used as an optimum SPE sorbent to clean up the extracts and preconcentrate the selected analytes. The proposed method showed satisfactory linearity and reproducibility (between 3 and 15%), as well as detection limits ranging from 30 to 220 ng/g. Finally, the method was successfully applied to the determination of the target pharmaceuticals in various kinds of mollusc samples. This study has demonstrated that microwave-assisted micellar extraction with solid-phase extraction may be used as a viable alternative to conventional methods for the extraction of pharmaceuticals in this type of matrices.  相似文献   

13.
A pilot-survey study was performed by collecting samples (influent and effluent wastewaters, rivers and tap waters) from different locations in Europe (Spain, Belgium, Germany and Slovenia). A solid-phase extraction (SPE) followed by liquid chromatography–tandem mass spectrometry method was applied for the determination of pharmaceuticals (ibuprofen, naproxen, ketoprofen, diclofenac and clofibric acid). Method detection limits and method quantification limits were at the parts-per-trillion level (7.5–75 ng/L). The recovery rates of the SPE from deionized water and effluent wastewater samples spiked at 100- and 1,000-ng/L levels ranged from 87 to 95%. Identification criteria in compliance with the EU regulation for confirmatory methods of organic residues were applied. A detailed study of signal suppression evaluation for analysis of pharmaceutical residues in effluent wastewaters is presented.  相似文献   

14.
《Comptes Rendus Chimie》2016,19(8):963-970
In the last few decades, the presence of pharmaceutical products in the environment is known under the name of emerging contaminants. These substances can enter the aquatic environment via different sources, as parent compounds, metabolites or a combination of both. In this work, we have investigated the presence of four pharmaceutical active compounds belonging to the group of Non-Steroidal Anti-Inflammatory Drugs (NSAIDs), in wastewater, surface water and drinking water of Algiers, which have a direct impact on the Mediterranean Sea. The target analytes (ibuprofen (IBU), naproxen (NAP), ketoprofen (KET), and diclofenac (DIC)), were extracted from the water samples by using Solid Phase Extraction Oasis® HLB Cartridges; the identification and quantification were realized by Gas Chromatography–Mass Spectrometry (GC–MS). To obtain the best resolution and precision, N-methyl-N-(trimethylsilyl) trifluoroacetamide (MSTFA) was used as the derivatization reagent and ibuprofen-d3 was used as the internal standard. The obtained recoveries were good, ranging from 82% for ketoprofen to 120% for naproxen with relatively small standard deviations (≤20%). The target compounds were detected in wastewater, influent/effluent with concentrations ranging from 155.5 to 6554 ng/L, implicating removal efficiencies of wastewater treatment plants (WWTPs), between 30.3 and 95%. The surface water was also contaminated with pharmaceuticals from 72.9 ng/L for diclofenac to 228.3 ng/L for naproxen. In addition, the occurrence of ibuprofen and ketoprofen in drinking water, at concentrations of 142.1 and 110.9 ng/L, respectively, attracts concerns about possible impacts on human health.  相似文献   

15.
Analytical methods have been developed for simultaneous determination of six different pharmaceuticals and personal care products (PPCPs) (clofibric acid, ibuprofen, naproxen, ketoprofen, diclofenac, and triclosan), three endocrine disrupting compounds (EDCs) (4-tert-octylphenol, 4-n-nonylphenol, and bisphenol A (BPA)) and one estrogenic compound (estrone) in soil matrix. The soils were extracted by different solvents with the help of an ultrasonic treatment at 42 kHz, followed by a solid phase extraction (SPE) as a cleanup procedure. The purified extracts were derivatized with N-methyl-N-(tert-butyldimethylsilyl) trifluoroacetamide (MTBSTFA) and then analyzed by GC-MSD (SIM mode). The method was evaluated by testing the following variables: initial spiking levels, extraction solvents, solvent volumes, and soil types (sandy and clay soils). For 5 g of soil, four successive extraction steps with the mixture of acetone-ethyl acetate provided satisfactory recoveries. In the sandy soil, the recoveries of all the compounds were from 63.8 to 110.7% for the spiking level of 100 ng/g dry soil, and from 52.2 to 108.2% for 5 ng/g dry soil, respectively. Result was similar for the clay soil. The precision across all recoveries was high, suggesting that this method has a good reproducibility. The method was successfully employed to soil samples collected from a golf course irrigated with reclaimed wastewater in southern California, and resulted in the detection of clofibric acid, ibuprofen, naproxen, triclosan, bisphenol A, and estrone at ng per gram dry weight concentration levels. The method is robust and simple, and provides straightforward analyses of these current-emerging trace organic pollutants in solid matrices.  相似文献   

16.
Concentrations of pharmaceuticals and personal care products (PPCPs) in natural solids remain largely unknown. Contributing to this, is a lack of methods permitting the simultaneous detection of the diverse, low-level contaminants present in these complex matrices. We have developed a microwave-assisted solvent extraction (MASE)-based method targeting seven diverse PPCPs (caffeine, 17β-estradiol, ibuprofen, ketoprofen, musk ketone, naproxen, and triclosan) and a molecular marker for fecal waste (epicoprostanol). The method consisted of optimizing the following variables: derivatization of the polar target analytes, silica gel open column clean-up, and gas chromatographic-mass spectrometric (GC-MS) analysis of sample extracts for analysis and detection of the compounds noted above. Testing of the method on spiked soil allowed for 89.6 ± 2.89% recovery of three target compounds and 25.0 ± 1.93% recovery of five of the compounds. Although the latter recoveries were low, the precision across all recoveries was high, suggesting good reproducibility in application of the method. Furthermore, we suspect that matrix effects are likely responsible for the lower recoveries. Techniques with the exclusive incorporation of organic solvents were found inapplicable in the study of a pharmaceutical salt, diphenhydramine HCl. Application of the developed method to sediment collected directly downstream of the effluent pipe of a wastewater treatment plant allowed detection of ibuprofen, naproxen, ketoprofen, and epicoprostanol at ng-μg per gram dry weight concentrations. The observation of acidic pharmaceuticals, previously believed to exhibit insignificant sorption to solid matrices, in the tested sediment samples, coupled with application of biosolids for agricultural purposes, demonstrates the need for expanded investigation of PPCP contamination of natural solid matrices.  相似文献   

17.
A method for the simultaneous determination of 16 pharmaceutical compounds in three types of sewage sludge (primary, secondary and anaerobically digested dehydrated sludge), compost and sediment samples is described. Pharmaceutical compounds evaluated were nonsteroidal anti‐inflammatory drugs (acetaminophen, diclofenac, ibuprofen, ketoprofen, naproxen and salicylic acid), antibiotics (sulfamethoxazole and trimethoprim), an anti‐epileptic drug (carbamazepine), a β‐blocker (propranolol), a nervous stimulant (caffeine), estrogens (17α‐ethinylestradiol, 17β‐estradiol, estriol and estrone) and lipid regulators (clofibric acid, metabolite of clofibrate and gemfibrozil). The method is based on the ultrasonic‐assisted extraction, clean‐up by SPE and analytical determination by HPLC with diode array and fluorescence detectors. The best extraction recoveries were achieved in a three‐step extraction procedure with methanol and acetone as extraction solvents. Extraction recoveries of several pharmaceutical compounds as caffeine were highly dependent on the type of sample evaluated. The applicability of the method was tested by analyzing primary, secondary and anaerobically digested dehydrated sludge, compost and sediment samples from Seville (Southern Spain). Ten of the sixteen pharmaceutical compounds were detected in sludge samples and five in compost and sediment samples. The highest concentration levels were recorded for ibuprofen in sewage samples, whereas salicylic acid and 17α‐ethinylestradiol were detected in all of the samples analyzed.  相似文献   

18.
A method for the quantitative determination of non-steroidal anti-inflammatory drugs (NSAIDs) in sewage sludge was developed and validated. The target compounds were extracted using pressurized hot water extraction (PHWE) and then purified and preconcentrated by three-phase hollow fiber liquid phase microextraction (HF-LPME) followed by LC–ESI-MS analysis. The PHWE was optimized with regard to the pH of solvent as well as other operational parameters. The optimum conditions were 0.01 M NaOH as the extraction solvent, temperature of 120 °C, pressure of 100 bar, static time 5 min, 5 cycles, flush volume 90% and purge time 60 s. Spike recoveries for sludge samples spiked at 200 ng g−1 were in the range of 101–109% but for the native drugs in non-spiked sludge samples, recoveries were 38.9%, 59.8%, 90.3% and 47.8% for ketoprofen, naproxen, diclofenac and ibuprofen, respectively. Donor phase pH, ionic strength and extraction time were optimized for HF-LPME after PHWE. The optimum conditions were 2 h extraction at pH 1.5 without salt addition. Enrichment factors in the range of 947–1213 times were achieved (extraction recoveries were 23.6–30.3%) for HF-LPME after PHWE. The matrix effect on the ionization of drugs in LC–ESI-MS was also investigated. The results show that there is a smaller matrix effect (−8.9% to +14.6%) in comparison with other published values obtained using solid phase extraction (SPE) for clean-up after pressurized liquid extraction (PLE). Method detection limits (MDLs) and method quantification limits (MQLs) for different drugs were in the range of 0.4–3.7 ng g−1 and 1.5–12.2 ng g−1 in dried sludge samples, respectively. The characteristics of the proposed method were compared with those of other published works. The considerably lower ion suppression/enhancement and minimum use of organic solvents (a few microliters of di-n-hexyl ether) in the sample preparation step are two highlighted advantages of the proposed method in comparison with previously published works. The method was applied to determine NSAIDs in sewage sludge from Källby wastewater treatment plant (Lund, Sweden) in April, June, August and October 2010. The highest concentration level was recorded for ibuprofen in the April sewage sludge sample (588 ng g−1) and all of the selected NSAIDs were detected in all the samples analyzed.  相似文献   

19.
Four different commercial sorbents for solid-phase extraction have been evaluated for the extraction of a group of acidic pharmaceuticals in terms of selectivity and capacity: Oasis hydrophilic-lipophilic balance (HLB), Oasis MAX (strong anion exchange), Oasis WAX (weak anion exchange) and a commercial available molecularly imprinted polymer specific for non-steroidal anti-inflammatory drugs. Among the sorbents studied, molecularly imprinted polymer proved to be very effective in the reduction of matrix interferences and the selective extraction of acidic pharmaceuticals, such as salicylic acid, ibuprofen, fenoprofen, diclofenac and naproxen, among others, from effluent wastewater samples. Moreover, molecularly imprinted solid-phase extraction protocol was applied to liquid chromatography coupled to tandem mass spectrometry (MS/MS) with the purpose of evaluating the clean-up effect on ion suppression/enhancement when the complexity of the samples increases and a reduction of this effect was observed. Molecularly imprinted solid-phase extraction followed by liquid chromatography coupled to ultraviolet detection and liquid chromatography coupled to tandem mass spectrometry validation methodologies with effluent wastewaters were developed, obtaining recoveries between 70 and 85% and limits of detection at low levels of μg/L (0.15-1 μg/L) and ng/L (0.5-2 ng/L), respectively. The final application of molecularly imprinted solid-phase extraction and liquid chromatography coupled to MS/MS detection showed the presence of acidic pharmaceuticals studied in this work in effluent wastewaters (相似文献   

20.
In this work, an ultra high-pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method has been developed for the simultaneous quantification and confirmation of the 20 most consumed pharmaceuticals in Spain in urban wastewater and surface water samples. The scope of the method included acidic, neutral and basic compounds belonging to different therapeutic classes and allows their simultaneous determination in just a single injection, giving realistic information of the most widely consumed pharmaceuticals in only one analysis. An enrichment step based on solid-phase extraction using Oasis HLB cartridges was carried out, followed by UHPLC-MS/MS measurement with a fast-acquisition triple quadrupole mass analyzer. It allowed working with short dwell times and made possible to acquire three simultaneous SRM transitions per compound to assure a reliable identification. Several isotope-labelled internal standards were used as surrogates to correct SPE losses, as well as matrix effects that notably affect quantification of analytes. The method was validated in surface water and effluent and influent urban wastewater at different concentrations from 0.005 μg/L (surface water) to 1.25 μg/L (influent wastewater). The optimized method was applied to the analysis of 84 urban wastewater samples (influent and effluent), with the result that 17 out of 20 compounds monitored were detected in the samples. Analgesics and anti-inflamatories, cholesterol lowering statin drugs and lipid regulators were the major groups found, with diclofenac, ketoprofen, naproxen, 4-aminoantipyrine, bezafibrate, gemfibrozil and venlafaxine being the most frequently detected. The highest concentration level reached was 277 μg/L for salicylic acid in influent wastewater.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号