首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Continuous ultrasound-assisted extraction has been coupled with preconcentration and flame atomic absorption spectrometry for the determination of cadmium and lead in mussel samples. Experimental designs were used for the optimisation of the leaching and preconcentration steps. The use of diluted nitric acid as extractant in the continuous mode at a flow rate of 3.5 ml min−1 and room temperature was sufficient for quantitative extraction of these trace metals. A minicolumn containing a chelating resin (Chelite P, with aminomethylphosphoric acid groups) was proved as an excellent material for the quantitative preconcentration of cadmium and lead prior to their flame atomic absorption detection. A flow injection manifold was used as interface for coupling the three analytical steps, which allowed the automation of the whole analytical process. A good precision of the whole procedure (2.0 and 2.3%), high enrichment factors (20.5 and 11.8) and a detection limit of 0.011 and 0.25 μg g−1 for cadmium and lead, respectively, were obtained for 80 mg of sample. The sample throughputs were ca. 16 and 14 samples h−1 for cadmium and lead, respectively. The accuracy of the analytical procedures was verified by using a standard reference material (BCR 278-R, mussel tissue) and the results were in good agreement with the certified values. The method was successfully applied to the determination of trace amounts of cadmium and lead in mussel samples from the coast of Galicia (NW, Spain).  相似文献   

2.
Iron was extracted on-line from solid meat samples by a simple and rapid continuous ultrasound-assisted extraction system (CUES). The CUES is connected to a flow injection manifold, which allows the on-line flame atomic absorption spectrometric determination of iron. A Plakett–Burman design was used for the optimisation of the CUES. The method achieved a total sampling frequency of 11 samples per hour with a relative standard deviation for the complete procedure of 0.4%. The detection limit was 0.6 g g–1 (dry mass) for a sample amount of 30 mg. Accurate results were obtained by measuring the certified reference materials BCR-186 (pig kidney) and BCR-184 (bovine muscle). The analytical procedure was applied to different real meat samples with satisfactory results.  相似文献   

3.
A flow analysis method with on-line sample digestion/minicolumn preconcentration/flame atomic absorption spectrometry is described for the determination of trace metals in urine. First, urine sample was on-line ultrasound-assisted digested exploiting the stopped-flow mode, and then the metals were preconcentrated passing the pre-treated sample through a minicolumn containing a chelating resin. A home-made minicolumn of commercially available imminodiacetic functional group resin, Chelite Che was used to preconcentrate trace metals (Cu, Fe, Mn and Ni) from urine. The proposed procedure allowed the determination of the metals with detection limits of 0.5, 1.1, 0.8 and 0.8 μg L−1, for Cu, Fe, Mn and Ni, respectively. The precision based on replicate analysis was less than ±10.0%, and the enrichment factor obtained was between 21.3 (Mn) and 44.1 (Ni), for sample volumes between 2.5 and 5.0 mL, and an eluent volume of 110 μL. This procedure was applied for determination of metals in urine of workers exposed to welding fumes and urine of unexposed persons (urine control).  相似文献   

4.
A continuous ultrasound-assisted extraction system connected to a flow injection manifold has been used for the on-line determination of zinc in meat samples by flame atomic absorption spectrometry. An experimental design was used for the optimisation of the continuous manifold. This flow injection methodology allowed a sampling frequency of ca. 80 samples per hour with a relative standard deviation for the whole procedure of 0.3% (for a sample containing 163.6 μg g−1 Zn). The detection limit was 0.6 μg g−1 for a sample amount of 5 mg. Accurate results were obtained by measuring certified reference materials (BCR-186 (pig kidney) and BCR-184 (bovine muscle)). The analytical procedure was applied to different real meat samples with satisfactory results.  相似文献   

5.
In this study, flow injection-cloud point extraction (FI-CPE) of iron and copper in food samples by flame atomic absorption spectrometric determination was described. Triton X-114 non-ionic surfactant and Eriochrome Cyanine R (ECR) have been used as an extraction medium and a chelating agent, respectively. The amounts of Triton X-114, ECR and the pH value necessary for extraction were carefully optimized. In addition, several parameters of the FI-CPE system, including sample loading rate, column dimension, type of packing material, eluent flow rate were investigated and analytical characteristics of the method were evaluated. Under optimum conditions, detection limits of 0.33 ng/mL and 0.57 ng/mL and quantification limits of 1.1 ng/mL and 1.9 ng/mL for iron and copper along with enrichment factors of 141 and 99 were obtained, respectively. The calibration was linear over the range 1.5-25 ng/mL and 1.0-35 ng/mL for iron and copper, respectively. The proposed CPE technique has been successfully applied for the determination of iron and copper ions in certified reference materials (NCS DC 73349—bush, branches and leaves; and TM-23.2—fortified water), water samples (mineral and sea water) and food samples (vegetables, bread and hazelnut) with high efficiency.  相似文献   

6.
Calcium was extracted on-line from solid seafood samples by a simple and rapid continuous ultrasound-assisted extraction system. This system is connected to a flow injection manifold, which allows the on-line flame atomic absorption spectrometric determination of calcium. This method enables the analysis of solid samples avoiding time-consuming traditional sample preparation methods and their inherent errors. The on-line manifold for calcium determination is the simplest possible, because a volume of 250 L of acid extract is injected into an ultrapure water carrier stream. The acid extract was diluted on-line with lanthanum, which also acts as masking agent in order to avoid chemical interferences. The continuous monitoring of the calcium signal was accomplished by flame atomic absorption spectrometry. A Plackett-Burman experimental design was used for the optimisation of the continuous leaching procedure. The method allowed a total sampling frequency of 40 samples per hour, with a relative standard deviation for the complete procedure of 0.9% (for a sample containing 3414.35 mg/kg calcium (dry mass)). The limit of detection was found to be 44.4 mg/kg (dry mass) for 5 mg of sample. The analytical procedure was applied to real seafood samples.  相似文献   

7.
A flow injection system was developed for on-line sorbent extraction preconcentration and flame atomic absorption spectrometric determination of cadmium in natural water samples. The non-charged cadmium complex with diethyl-dithiophosphate (DDPA) was formed on-line in 0.1 mol L−1 HNO3 and retained on the hydrophobic poly-chlorotrifluoroethylene (PCTFE) sorbent material. The adsorbed complex was eluted with isobutyl methylketone (IBMK) and injected directly into the nebulizer via a flow compensation unit. All major chemical and flow parameters affecting the complex formation adsorption and elution as well as interference were studied and optimized. By processing 2.4 mL of sample, the enhancement factor was 39 and the sampling frequency was 50 h−1. For 30 s preconcentration time the detection limit was 0.3 μg L−1 and the relative standard deviation at 5.0 μg L−1 Cd concentration level was 2.9%. The calibration curve was linear in the range 0.8–40.0 μg L−1. The accuracy of the method was estimated by analyzing a certified reference material NIST-CRM 1643d (Trace elements in water). Good recoveries were obtained for spiked natural-water and waste-water samples. Correspondence: Aristidis N. Anthemidis, Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, GR-Thessaloniki 54124, Greece  相似文献   

8.
A sensitive and selective method was developed for the determination of traces of manganese in urine using on-line electrochemical preconcentration followed by flame atomic absorption spectrometry detection. A home made flow-through polypropylene cell (4.5 cm long × 0.8 cm diameter filled with glass marbles) with an effective inner volume of 0.5 ml containing a working and a counter electrode, both of glassy carbon and a Pt pseudo reference electrode was located in a flow injection manifold specially designed for the purpose of this work. The manganese was deposited from buffer solution of NH3/NH4Cl at pH 9.00 through an oxidizing process at a current of 400 mA during 7 min. A flow of HCl 0.1 mol l−1 at 4 ml min−1 through the cell, chemically dissolved the deposit. A small portion (15 μl) of the concentrate was introduced in a continuously flowing system by means of a timing device and was then carried to the detector for the manganese quantification. All electrochemical and spectroscopic variables as well as possible interferences in both systems were systematically studied. The relative standard deviations for ten consecutive measurements of manganese solutions of 2.0 and 20 μg l−1 were of 2.3 and 1.5%, respectively, while for a sample processed five times was less then 5%. The accuracy of the developed procedure was evaluated by adding known amounts of manganese standard to urine samples and following the whole procedure. Recoveries within the range 97.2-102.8% were obtained. To further prove the accuracy, a Seronorm Trace Elements in Urine, Batch 403125 sample with a reported concentration of 13 μg Mn l−1 was also analyzed. The experimental value obtained was of 12.7 ± 0.1 μg l−1, which does not differ significantly from the reported amount (p < 0.05). A preconcentration factor of 40, a linear range between 0.015 and 60 μg l−1 and a limit of detection of 15 ng l−1 permitted the determination of manganese in real urine samples from non-exposed subjects in the range 0.5-2.8 μg l−1.  相似文献   

9.
A dynamic ultrasound-assisted extraction step is proposed for the quantitative extraction of Cd and Pb from plant leaves prior to determination by electrothermal atomic absorption spectrometry (ETAAS). Beech leaves (a certified reference material—CRM 100—where the target analytes were not certified) were used for optimizing the extraction step by a multivariate approach. The samples (0.25 g) were subjected to dynamic ultrasound-assisted extraction with dilute nitric acid as extractant. The method was validated with a certified reference material BCR-062 (olive leaves) where both Cd and Pb are certified. The good agreement between the certified values and those found using the proposed method demonstrates its usefulness. The repeatability was 2.0 and 0.9% and the within-laboratory reproducibility was 7.1 and 2.8% for Cd and Pb, respectively. The precision of the method, together with its efficiency, rapidity, low cost and environmental acceptability makes it a good alternative for the determination of trace metals from plant material.  相似文献   

10.
Using octadecyl functional groups (C18) bonded to silica gel as sorbent and methanol as eluent, the flow injection sorbent extraction features of dialkyldithiophosphates (RO)2P(S)S as the chelating agent for cadmium, copper and lead was investigated in respect of the effects of pH, alkyl substituent group, reagent concentration and masking agent, with flame atomic absorption spectrometric detection. The elements are quantitatively extracted with the short-alkyl-chain reagents (R up to propyl) in acidic medium. The extractability decreases with the number of carbon atoms in the alkyl groups of the reagents and with the reagent concentration when the alkyl groups are larger than butyl, but masking agents increase the extractability. An explanation proposed for this effect is the formation of polynuclear chelates. Diethyldithiophosphate can be used for the selective determination of cadmium, copper and lead in digested solid environmental samples. With 20 s sample loading at 8.7 ml min−1, the enhancement factors are 35 for cadmium and copper or 26 for lead; the detection limits (3σ) are 0.8, 1.4 and 10.0 μg 1−1 for cadmium, copper and lead, respectively.  相似文献   

11.
A direct solid sampling flame atomic absorption spectrometric procedure for trace determination of cadmium in biological samples has been developed. Test samples (0.05–2.00 mg) were ground and weighed into small polyethylene vials, which were connected to the device for solid sample introduction into a conventional air/acetylene flame. Test samples were carried as a dry aerosol to a quartz cell, placed between the burner and the optical path, which had a perpendicular entrance and a slit in the upper part. The atomic vapor generated in the flame produced a transient signal that was totally integrated within 1 s. The effect of operating conditions and the extent of grinding on the analytical signal were evaluated. Background signals were always low and a characteristic mass of 0.29 ng Cd was obtained. Calibration was performed using different masses of solid certified reference materials. Results obtained for certified and in-house reference materials were typically within the 95% confidence interval of the certified and/or reference value, and the precision, expressed as relative standard deviation, was between 3.8 and 6.7%. The proposed system is simple and it might be adapted to conventional atomic absorption spectrometers allowing the determination of Cd in more than 80 test samples per hour, excluding weighing.  相似文献   

12.
提出了以732强酸型阳离子树脂作填充材料,流动注射在线离子交换预富集火焰原子吸收光谱法测定水样中微量锰的分析方法。优化了各项化学条件和流路参数等,考察了共存离子的干扰。富集倍数可达24倍,分析速度为15~20样/h,检出限为2.0ng/mL,相对标准偏差为2.8%(n=15)。对雨水加标回收,回收率为97%~103%。  相似文献   

13.
采用单阀双阳离子交换树脂微柱并联,设计了双路采样逆向洗脱在线分离富集系统,该系统与原子吸收测量技术相结合,实现了在线分离富集-火焰原子吸收光谱法同时测定水中Cr(Ⅲ)和Cr(Ⅵ),富集1min时,分析速度为60样/h,测定Cr(Ⅲ)和Cr(Ⅵ)的特征浓度分别为6.08μg/L和11.58μg/L(相当于1%吸收),线性范围分别为0~1.0μg/mL和0~2.0μg/mL,对质量浓度为100μg/L的Cr(Ⅲ)和Cr(Ⅵ)测定的相对标准偏差分别为2.9%和3.0%、检出限分别为8.70和10.8μg/L。该法对实际水样加标回收率在94.5%~104.3%之间。  相似文献   

14.
Yu HM  Song H  Chen ML 《Talanta》2011,85(1):625-630
A novel adsorbent-silica gel bound dithizone (H2Dz-SG) was prepared and used as solid-phase extraction of copper from complex matrix. The H2Dz-SG is investigated by means of FT-IR spectra and the SEM images, demonstrating the bonding of dithizone. The H2Dz-SG quantitatively adsorb copper ions, and the retained copper is afterwards collected by elution of 10% (v/v) nitric acid. An on-line flow injection solid-phase extraction procedure was developed for trace copper separation and preconcentration with detection by flame atomic spectrometry. By loading 5.4 mL of sample solution, a liner range of 0.5-120 μg L−1, an enrichment factor of 42.6, a detection limit of 0.2 μg L−1 and a precision of 1.7% RSD at the 40 μg L−1 level (n = 11) were obtained, along with a sampling frequency of 47 h−1. The dynamic sorption capacity of H2Dz-SG to Cu2+ was 0.76 mg g−1. The accuracy of the proposed procedure was evaluated by determination of copper in reference water sample. The potential applications of the procedure for extraction of trace copper were successfully accomplished in water samples (tap, rain, snow, sea and river). The spiking recoveries within 91-107% are achieved.  相似文献   

15.
A new and simple flow injection system procedure has been developed for the indirect determination of cyanide. The method is based on insertion of aqueous cyanide solutions into an on-line cadmium carbonate packed column (25% m/m suspended on silica gel beads) and a sodium hydroxide with pH 10 is used as the carrier stream. The eluent containing the analyte as cadmiumcyanide complexes, produced from reaction between cadmium carbonate and cyanide, measured by flame atomic absorption spectrometry. The absorbance is proportional to the concentration of cyanide in the sample. The linear range of the system is up to 15 mg L−1 with a detection limit 0.2 mg L−1 and sampling rate 72 h−1. The method is suitable for determination of cyanide in industrial waste waters with a relative standard deviation better than 1.22%.  相似文献   

16.
A simple and inexpensive procedure is proposed for the extension of the dynamic range of flame atomic absorption spectrometry measurements using on-line dilution. The proposed methodology is based on the use of a manifold with two coupled dilution chambers and a zone injection system. The samples are prediluted in a closed system which includes a variable-volume mixing chamber (10–120 ml) and two injection valves. The samples are injected through one of these valves, and the other is employed to take 100 μl of prediluted samples which are then passed through a new dilution chamber (volume 1–10 ml) and aspirated by the nebulizer of the instrument. A third injection valve mounted in the last part of the manifold is used for the direct injection of diluted standard solutions. Various dilution factors are obtained, ranging from 2 to 130 000 times, thus extending the analytical range of copper determination to more than 100 000 mg l−1.  相似文献   

17.
Derya Kara 《Talanta》2009,79(2):429-545
Micelle-mediated extraction/preconcentration is incorporated on-line into a flow injection system used to determine low levels of Cd(II), Co(II), Cu(II), Mn(II), Ni(II), Pb(II) and Zn(II) present in various samples. The analyte is complexed with HBDAP (N,N′-bis(2-hydroxy-5-bromo-benzyl)1,2-diaminopropane). Under optimal conditions, a solution of 30% (m/v) NaCl and a sample solution containing 2.5 mL of 1% (m/v) sodium dodecyl sulfate (SDS), 0.5 mL of 1.8 × 10−3 M HBDAP and 2.5 mL of pH 8.5 borate buffer solution in 25 mL were pumped through the cotton filled mini-column; onto which the surfactant-rich phase containing the complex is collected. A solution of 0.5 M HNO3 in 50% acetone is used as the eluent. The limits of detection are (ng mL−1) Cd = 0.39, Cu = 3.2, Co = 7.5, Mn = 3.0, Ni = 3.4, Pb = 17.9 and Zn = 0.89 if the sample is allowed to flow for 30 s, but improved for extended preconcentration periods. Analysis of liquid and solid reference materials showed good agreement with the certified values. Complex formation constants between HBDAP and these metal ions were also determined potentiometrically.  相似文献   

18.
Cloud point extraction (CPE) has been used for the simultaneous pre-concentration of cadmium, copper, lead and zinc after the formation of a complex with 1-(2-thiazolylazo)-2-naphthol (TAN), and later analysis by flame atomic absorption spectrometry (FAAS) using octylphenoxypolyethoxyethanol (Triton X-114) as surfactant. The chemical variables affecting the separation phase and the viscosity affecting the detection process were optimized. At pH 8.6, pre-concentration of only 50 ml of sample in the presence of 0.05% Triton X-114 and 2×10−5 mol l−1 TAN permitted the detection of 0.099, 0.27, 1.1 and 0.095 ng ml−1 cadmium, copper, lead and zinc, respectively. The enhancement factors were 57.7, 64.3, 55.6 and 63.7 for cadmium, copper, lead and zinc, respectively. The proposed method has been applied to the determination of cadmium, copper, lead and zinc in water samples and a standard reference material (SRM).  相似文献   

19.
The process of ultrasound-assisted emulsification-microextraction (USAEME) was successfully applied for the first time for the extraction and pre-concentration of trace cadmium from water samples, followed by flame atomic absorption spectrometry (FAAS). In the proposed approach, sodium diethyldithiocarbamate trihydrate solution (NaDDTC·3H2O) was used as a chelating agent and carbon tetrachloride was selected as extraction solvent. Some effective parameters on the microextraction and the complex formation were selected and optimized. These parameters included extraction solvent type as well as extraction volume, time, temperature, and pH, the amount of the chelating agent, and salt effect. Under optimum conditions, an enrichment factor of 95 was obtained from only 5.0 mL of water sample. The calibration graph was linear in the range of 10-600 μg L−1 with a detection limit of 0.91 μg L−1. The relative standard deviation (R.S.D) for ten replicate measurements of 50 and 500 μg L−1 of cadmium were 2.56 and 1.62%. This proposed method was successfully applied in the analysis of four real environmental water samples and good spiked recoveries over the range of 96.5-101.7% were obtained.  相似文献   

20.
A calibration method has been developed which is realised in the flow injection analysis (FIA) by the gradient technique. According to this method two transient peaks, one for a sample and the other for a sample with standard addition, are recorded and compared point by point in the entire defined time range. The analytical result is estimated on the basis of information gained about the local analyte concentrations in the sample zone. The method allows the results to be reliable when both the non-linear calibration dependence and the interference effect occur. As an example, calcium in synthetic samples containing silicon, phosphate, aluminium, vanadium and titanium, and also in iron ore sample, were determined by flame atomic absorption spectrometry (FAAS). It has been proved, that the method can be effective in overcoming even extremely strong interferences, providing analytical results with average accuracy equal to ca. 5% and with precision 2–3 times inferior to that obtained by conventional FI calibration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号