首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 593 毫秒
1.
况鹏  韩小龙  曹兴忠  夏锐  张鹏  王宝义 《中国物理 B》2017,26(5):57802-057802
Doppler broadening and coincidence Doppler broadening of annihilation radiation experiments have been performed in three kinds of polyethylene glycol(PEG) membrane formed with different average molecular weight using the tunable monoenergy slow positron probe as a function of implantion energy. The obtained positron annihilation parameters are interpreted from two aspects: surface effect and differences in micro-structure or chemical environment of positron annihilation. The experimental results show that the regulation of densification of PEG molecular packing and distribution uniformity from the near surface layer to the bulk region in the film forming process can be well realized by changing its molecular weight. Combining a variable monoenergetic slow positron beam and these two positron annihilation spectroscopy methods is a powerful tool to study positron annihilation characteristics and for polymeric thin-film fine structure analysis.  相似文献   

2.
The Beijing intense slow positron beam facility is based on the 1.3 GeV linac of Beijing ElectronPositron CoUider (BEPC) aiming to produce mono-energetic intense slow positron beam for material science investigation. The plugged-in 22Na based slow positron beam section has been newly constructed to supply continuous beam time for the debugging of positron annihilation measurement stations and improve the Beijing intense slow positron beam time using efficiency. Performance testing result of the plugged-in 22Na based slow positron beam facility are reviewed in this paper, with the measurement of the beam transport efficiency, the view of beam spot, the adjustment of beam position, the measurement of beam intensity and energy spread etc. included.  相似文献   

3.
FeMnSi shape memory alloys (SMAs) have received much attention as one-way SMAs due to their cost-effectiveness. Variable-energy (0-30 keV) positron beam studies have been carried out on a Fe-Mn-Si-Cr-Ni-C alloy with different degrees of deformation. Doppler broadening profiles of the positron annihilation as a function of incident positron energy were shown to be quite sensitive to defects introduced by deformation. The variation of the nature and the concentration of defects are studied as a function of isochronal annealing temperature. These results are correlated with the data measured with the positron annihilation lifetime spectroscopy (PALS). The positron annihilation results are compared to XRD and optical microscopy (OM).  相似文献   

4.
Various diagnostic techniques have been applied at the neutron-induced positron source Munich NEPOMUC in order to determine the positron beam parameters such as intensity, beam shape and energy distribution. The positron beam intensity is determined by the detection of the annihilation radiation of positrons, which annihilate in a movable target. The use of a micro-channel plate (MCP) detector with a CCD-camera allows a direct measurement of the positron beam shape and the lateral resolved intensity distribution. At NEPOMUC a movable MCP-assembly inside the evacuated beam line enables a quick examination of the beam shape during operation. A retarding grid was mounted inside the homogeneous magnetic guiding field in order to determine the distribution of the longitudinal positron momentum, and hence estimate the energy distribution of the positrons.  相似文献   

5.
We have developed a positron microbeam using magnetic lenses based on the commercial scanning electron microscope (SEM). A slow positron beam was generated using a handmade source with 22Na and a solid neon moderator. The beam diameter was 3.9 μm on a target. Two-dimensional image of S parameter was successfully obtained. By introducing a beam pulsing section, positron lifetime measurement beam is also available.  相似文献   

6.
Steels with high amounts of silicon are used in electrical applications due to their low magnetostriction, high electrical resistivity and reduced energy losses, but they exhibit poor formability. The slow positron beam of Gent is used to investigate defects in different deformed FeSi alloys. It was found that the concentration of defects for the alloys deformed at high temperatures are different from the ones related to the alloys deformed at room temperature. These results are correlated to the results of positron annihilation lifetime spectroscopy (PALS).  相似文献   

7.
慢正电子湮没寿命测量是研究材料表面微观缺陷的重要分析方法.束团化系统是实现慢正电子湮没寿命测量的核心部件, 主要由斩波、聚束两部分组成, 它可以将随时间连续分布的束流束团化, 从而获得正电子湮没寿命测量的时间起点及满足时间分辨率要求的束团.本文以粒子动力学计算为基础, 完成了束团化系统的物理设计, 其时间分辨率设计值为150ps(FWHM).  相似文献   

8.
The design of a pulsing system for an intense slow positron beam is described in this paper. Slow positron annihilation lifetime measurement is an important method to study the depth-dependent characteristics of the surface and near surface. The start signal for slow positron lifetime measurement can be obtained from the pulsing system, which consists of a reflection type chopper, a prebuncher and a buncher. On the basis of the simulation of dynamics process by Parmela, the frequency of the buncher and the positron energy have been chosen to be 150MHz and 330eV respectively. The designed time resolution of this system is about 150ps (FWHM).  相似文献   

9.
Porous silica films were synthesized via a sol–gel method using a nonionic amphiphilic triblock copolymer F127 as the structural template. Mesoporosities of the prepared silica films were investigated by Doppler broadening of positron annihilation radiation (DBAR) spectroscopy, positron annihilation gamma-ray energy spectroscopy based on a slow positron beam, and ellipsometry. For the mesoporous silica films, the variation of positron annihilation line shape parameter reveals that the porosity of the silica films increases with loading more F127, which is also confirmed by a decrease of refractive index n. Little variation in positron 3γ-annihilation fraction is found for the silica films prepared with F127 loading less than 15 wt%, whereas a remarkable increment is seen for the films with higher loading. This indicates the pore percolation in porous silica films occurs around a loading of F127 with 15 wt%.  相似文献   

10.
Doppler broadening of annihilation radiation (DBAR) and positron annihilation lifetime spectroscopy (PALS) have been successfully applied to the study of positronium (Ps)—forming amorphous solids such as polymers and silicon oxide in the bulk. Implementing depth selectivity to DBAR and PALS by combining them with variable-energy positron beams considerably broadens their applicability. Variation of incident positron energy over a wide range enables depth-profiling, whereas tuning of the beam energy enables the studies of surfaces, interfaces and thin films. In this paper, we discuss fundamentals and applications of energy variable DBAR and PALS for Ps—forming polymers and silicon oxide.  相似文献   

11.
郁伟中  袁佳平 《物理》2001,30(2):95-100
正电子湮没技术是一种研究材料的微观缺陷和相变的灵敏工具,在通常的正电子谱仪中,正电子能量为MeV量级,在样品中注入深度比较学(-100μm),主要研究材料体内的平均缺陷密度,慢正电子束方法把正电子的能量降低为keV量级(而且可以调节),注入比较浅(-μm),所以是研究表面缺陷的探测手段,正电子慢化体是产生慢正电子的关键设备,对其研究有重要意义,文章综述了慢化体研究的历史和现状,从物理概念出发介绍使正电子慢化的四种可能方法和当今慢化体的五种几何排列方法,其中应用最广泛的是钨慢化体和百叶窗式的排列方式,效率最高的是惰性气体固体慢化体,而加电场慢化体是有待开发的高效慢化体。  相似文献   

12.
用慢正电子束入射固体靶表面,通过测量湮没光子能谱随靶温度和入射慢正电子能量的变化,用“峰法”确定慢正电子产生电子偶素原子的转换率。转换率依赖于靶材料、靶温度和入射慢正电子能量。对材料锗转换率可达80%。 关键词:  相似文献   

13.
We report an exact analytical solution of so-called positron diffusion trapping model. This model have been widely used for the treatment of the experimental data for defect profiling of the adjoin surface layer using the variable energy positron (VEP) beam technique. However, up to now this model could be treated only numerically with so-called VEPFIT program. The explicit form of the solutions is obtained for the realistic cases when defect profile is described by a discreet step-like function and continuous exponential-like function. Our solutions allow to derive the analytical expressions for typical positron annihilation characteristics including the positron lifetime spectrum. Latter quantity could be measured using the pulsed, slow positron beam. Our analytical results are in good coincidence with both the VEPFIT numerics and experimental data. The presented solutions are easily generalizable for defect profiles of other shapes and can be well used for much more precise treatment of above experimental data.  相似文献   

14.
正电子湮没谱学技术是研究材料微观结构非常有效的一种核谱学分析方法, 主要用于获取材料内部微观结构的分布信息, 特别是微观缺陷结构及其特性等传统表征方法难以获取的微观结构信息. 近年来, 在慢正电子束流技术快速发展的基础上, 正电子湮没谱学技术在薄膜材料表面和界面微观结构的研究中得到了广泛应用. 特别是该技术对空位型缺陷的高灵敏表征能力, 使其在金属/合金材料表面微观缺陷的形成机理、缺陷结构特性及其演化行为等研究方面具有独特的优势. 针对材料内部微观缺陷的形成、演化机理以及缺陷特性的研究, 如缺陷的微观结构、化学环境、电子密度和动量分布等, 正电子湮没谱学测量方法和表征分析技术已经发展成熟. 而能量连续可调的低能正电子束流, 进一步实现了薄膜材料表面微观结构深度分布信息的实验表征. 本文综述了慢正电子束流技术应用研究的最新进展, 主要围绕北京慢正电子束流装置在金属/合金材料微观缺陷的研究中对微观缺陷特性的表征和表面微观缺陷演化行为的应用研究成果展开论述.  相似文献   

15.
The annealing of radiation defects in GaAs by a supercurrent proton beam with currents up to 200 A cm?2 and 4.8 MeV energy was studied. The positron annihilation method (measurement of angular distribution of annihilation photons) has been used to study the depth profiles of radiation defects in solids. Profiles of vacancy-type defects in GaAs irradiated by a supercurrent proton beam have been measured.  相似文献   

16.
A new type positron beam system is being constructed in Wuhan university. The goal of this project is to build a positron beam which can measure positron lifetimes and has high moderation efficiency. The system utilizes a magnetically guided incident positron beam and the sample is biased to a high negative potential to achieve the desired implantation energies. A conventional tungsten moderator is replaced by a solid Ne moderator with high moderation efficiency (about 1%). A multi-functional target chamber for slow beam studies is designed, which can be used for positron annihilation lifetime spectroscopy (PALS), Doppler broadening (DB) and coincidence Doppler broadening (CDB) measurements.  相似文献   

17.
Cavitation-induced micro-defects in mild steel after cavitation experiment in the fluid field have been studied by positron Doppler broadening measurement and positron annihilation lifetime spectra (PALS). Depth-resolved positron Doppler S-parameter (DPDS) results showed that S-parameter increased and micro-defects between the surface and the bulk has obvious variation with depth during the cavitation process. From the positron lifetime results, it was found that the size and number of micro-defects increase with the development of cavitation. These results suggest that more micro-defects are generated in mild steel bulk during the cavitation process than those in the mild steel surface layer region, although more mico-defects seen in the mild steel surface layer. Moreover, the size of micro-defects in mild steel bulk increases remarkably owing to their transfer and aggregation.  相似文献   

18.
A new slow pulsed positron beam, including a positron source, a moderator, a chopper, a pre-buncher, a main-buncher and a sample chamber, etc, has been installed and tested. It is necessary to simulate the acceleration, transportation and space focusing of positrons to meet the needs of beam debugging and further positron annihilation experiments. The result from SIMION simulations shows that the radius of the focused positron beam is less than 5 mm, which is further confirmed in our practical debugging process.  相似文献   

19.
It is generally believed that the high momentum components (HMCs) of the angular correlation of annihilation radiation or Doppler broadening spectra map the positron annihilation with predominately core electrons, containing only a small fraction coming from localised d+f-type valence electrons. In present work, we study how far the contribution of valence electrons to the HMCs of the electron-positron (e-p) momentum density can be neglected. Calculations are performed for gold within both the independent particles model (IPM) and including the e-p correlation effects non-locally, using the weighted density approximation (WDA). In particular, the HMCs due to valence s+p-type electrons are compared with their core and d+f-type valence counterparts.  相似文献   

20.
Contamination-tolerant adhesives are of ever increasing importance in industrial applications. The possible failure mechanisms of adhesive bonds in these adhesives are however still poorly understood. Results of a series of investigations with our pulsed low energy positron beam system (PLEPS) in an epoxy-based contamination-tolerant adhesive are presented.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号