首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A novel sequential injection (SI) method was developed for the determination of penicillamine (PA) and ephedrine (EP) based on the reaction of these drugs with tris(bipyridyl)ruthenium(II) (Ru(bpy)32+) and peroxydisulfate (S2O82−) in the presence of light. Derivatization of PA and EP with aldehydes has resulted in a significant enhancement of the chemiluminescence emission signal by at least 25 times for PA and 12 times for EP, leading to better sensitivities and lower detection limits for both drugs. The instrumental setup utilized a syringe pump and a multiposition valve to aspirate the reagents, (Ru(bpy)32+ and S2O82−), and a peristaltic pump to propel the sample. The experimental conditions affecting the derivatization reaction and the chemiluminescence reaction were systematically optimized using the univariate approach. Under the optimum conditions linear calibration curves between 0.2–24 μg mL−1 for PA and 0.2–20 μg mL−1 for EP were obtained. The detection limits were 0.1 μg mL−1 for PA and 0.03 μg mL−1 for EP. The procedure was applied to the analysis of PA and EP in pharmaceutical products and was found to be free from interferences from concomitants usually present in these preparations.  相似文献   

2.
An on-line stacking method based on moving reaction boundary (MRB) was developed for the sensitive determination of barbital and phenobarbital in human urine via capillary electrophoresis (CE). The optimized conditions for the method are: 60 mmol L−1 pH 11.0 Gly–NaOH as the background electrolyte, 10 mmol L−1 pH 5.5 Gly–HCl as sample buffer, secobarbital as the internal standard (IS), 12.5 kV, 1.4 psi 10 s sample injection, 75 μm ID 60.2 cm total length (50 cm effective length) capillary and 214 nm detect wavelength. Under the optimized conditions, the method can well stack and separate barbital and phenobarbital in urine samples and result in 20.5-fold and 22.6-fold improvement in concentration sensitivity for barbital and phenobarbital, respectively. Furthermore, the method holds: (1) good linear calibration functions for the two target compounds (correlation coefficients r > 0.999), (2) low limits of detection (0.27 μg mL−1 for barbital and 0.26 μg mL−1 for phenobarbital), (3) low limits of quantification (0.92 μg mL−1 for barbital and 0.87 μg mL−1 for phenobarbital), (4) good precision (R.S.D. of intra-day and inter-day less than 5.38% for barbital and 1.67% for phenobarbital, respectively) and (5) high recoveries at three concentration levels (90.27–106.36% for barbital and 93.05–113.60% for phenobarbital in urine). The method is simple, sensitive and efficient, and can fit to the need of clinical and forensic toxicology.  相似文献   

3.
Khaled E 《Talanta》2008,75(5):1167-1174
A simple, rapid and accurate method for the spectrophotometric determination of terfenadine has been developed. The proposed method based on the charge-transfer reactions of terfenadine, as n-electron donor, with 7,7,8,8-tetracyanoquinodimethane (TCNQ), tetracyanoethylene (TCNE), 2,3-dichloro-5,6-dicyano-1,4-benzoquinone (DDQ) or 2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone (chloranilic acid, p-CLA) as π-acceptors to give highly colored complexes. The experimental conditions such as reagent concentration, reaction solvent and time have been carefully optimized to achieve the highest sensitivity. Beer's law is obeyed over the concentration ranges of 3–72, 3–96, 12–168 and 24–240 μg mL−1 terfenadine using TCNQ, TCNE, DDQ and p-CLA, respectively, with correlation coefficients 0.9999, 0.9974, 0.9997 and 0.9979 and detection limits 0.3, 0.4, 2.6 and 12.3 μg mL−1, for the reagents in the same order. DDQ and p-CLA react spontaneously with terfenadine to give colored complexes that can be applied for the flow injection analysis of terfenadine in the concentration ranges 2.4–120 and 24–240 μg with correlation coefficients 0.9990 and 0.9985 and detection limits 0.8 and 2.7 μg for DDQ and p-CLA, respectively, in addition to the high sampling through output of 40 sample h−1.  相似文献   

4.
Yazdi AS  Razavi N  Yazdinejad SR 《Talanta》2008,75(5):1293-1299
Dispersive liquid–liquid microextraction (DLLME) coupled with gas chromatography–flame ionization detection (GC–FID) was applied for the determination of two tricyclic antidepressant drugs (TCAs), amitriptyline and nortriptyline, from water samples. This method is a very simple and rapid method for the extraction and preconcentration of these drugs from environmental sample solutions. In this method, the appropriate mixture of extraction solvent (18 μL Carbon tetrachloride) and disperser solvent (1 mL methanol) are injected rapidly into the aqueous sample (5.0 mL) by syringe. Therefore, cloudy solution is formed. In fact, it is consisted of fine particles of extraction solvent which is dispersed entirely into aqueous phase. The mixture was centrifuged and the extraction solvent is sedimented on the bottom of the conical test tube. 2.0 μL of the sedimented phase is injected into the GC for separation and determination of TCAs. Some important parameters, such as kind of extraction and disperser solvent and volume of them, extraction time, pH and ionic strength of the aqueous feed solution were optimized. Under the optimal conditions, the enrichment factors and extraction recoveries were between 740.04–1000.25 and 54.76–74.02%, respectively. The linear range was (0.005–16 μg mL−1) and limits of detection were between 0.005 and 0.01 μg mL−1 for each of the analytes. The relative standard deviations (R.S.D.) for 4 μg mL−1 of TCAs in water were in the range of 5.6–6.4 (n = 6). The performance of the proposed technique was evaluated for determination of TCAs in blood plasma.  相似文献   

5.
Ruengsitagoon W 《Talanta》2008,74(5):1236-1241
A simple reversed flow injection colourimetric procedure for determining iron(III) was proposed. It is based on the reaction between iron(III) with chlortetracycline, resulting in an intense yellow complex with a suitable absorption at 435 nm. A 200 μl chlortetracycline reagent solution was injected into the phosphate buffer stream (flow rate 2.0 ml min−1) which was then merged with iron(III) standard or sample in dilute nitric acid stream (flow rate 1.5 ml min−1). Optimum conditions for determining iron(III) were investigated by univariate method. Under the optimum conditions, a linear calibration graph was obtained over the range 0.5–20.0 μg ml−1. The detection limit (3σ) and the quantification limit (10σ) were 0.10 and 0.82 μg ml−1, respectively. The relatives standard deviation of the proposed method calculated from 12 replicate injections of 2.0 and 10.0 μg ml−1 iron(III) were 0.43 and 0.59%, respectively. The sample throughput was 60 h−1. The proposed method has been satisfactorily applied to the determination of iron(III) in natural waters.  相似文献   

6.
This article describes the preparation of dithiocarbamate immobilized/functionalized and diethylammonium dithiocarbamate (DDTC) sorbed Merrifield Chloromethylated Resin (MCR) beads and comparison of these materials for on-line flow injection (FI)–flame atomic absorption spectrometry (FAAS) determination of lead. The above two materials enrich lead quantitatively over an identical optimal pH range (8.0–9.0), a preconcentration/loading time (up to 4 min) and elution with acidified methanol (a minimum of 0.01 mol L−1 HNO3 in methanol). However, the detection limit for lead using dithiocarbamate functionalized MCR beads is 1.3 μg L−1 compared to 3 μg L−1 for DDTC sorbed MCR beads. Again, the sensitivity enhancement over direct FAAS signal is 48- and 27-fold, respectively. In addition, dithiocarbamate functionalized MCR beads offers better precision compared to DDTC sorbed MCR beads as the corresponding relative standard deviation (R.S.D.) values for five successive determinations of 0.20 μg mL−1 are 1.44 and 4.36%, respectively. The accuracy of the developed on-line FI–FAAS procedure employing dithiocarbamate functionalized MCR beads as column material was tested by analyzing Certified Reference Material (CRM) of soil (IAEA soil-7) and marine sediment reference material (MESS-3) supplied by International Atomic Energy Agency (IAEA), Vienna and National Research Council (NRC), Canada, respectively. Furthermore, the developed procedure has been successfully tested for the analysis of surface, pond, ground and effluent water and soil samples collected from the vicinity of lead acid battery industry in India.  相似文献   

7.
Nie F  Lu J 《Talanta》2008,74(5):1242-1246
Calcein was found to be able to use as chemiluminescence reagent and post-chemiluminescence was observed when fenfluramine was injected into the mixture after the CL reaction of calcein–potassium permanganate. Based on this phenomenon, a flow injection CL method was established for the determination of fenfluramine. The possible CL mechanism was proposed. The CL intensity was correlated linearly with the concentration of fenfluramine over the range of 1.0 × 10−7 to 6.0 × 10−6 g mL−1 and the detection limit was 6 × 10−8 g mL−1. The relative standard deviation was 2.2% for 5.0 × 10−7 g mL−1 fenfluramine (n = 11). This method was applied to the determination of fenfluramine in weight-reducing tonic successfully.  相似文献   

8.
Burakham R  Oshima M  Grudpan K  Motomizu S 《Talanta》2004,64(5):1259-1265
A novel spectrophotometric reaction system was developed for the determination of nitrite as well as nitrate in water samples, and was applied to a flow-injection analysis (FIA). The spectrophotometric flow-injection system coupled with a copperised cadmium reductor column was proposed. The detection was based on the nitrosation reaction between nitrite ion and phloroglucinol (1,3,5-trihydroxybenzene), a commercially available phenolic compound. Sample injected into a carrier stream was split into two streams at the Y-shaped connector. One of the streams merged directly and reacted with the reagent stream: nitrite ion in the samples was detected. The other stream was passed through the copperised cadmium reductor column, where the reduction of nitrate to nitrite occurred, and the sample zone was then mixed with the reagent stream and passed through the detector: the sum of nitrate and nitrite was detected. The optimised conditions allow a linear calibration range of 0.03–0.30 μg NO2-N ml−1 and 0.10–1.00 μg NO3-N ml−1. The detection limits for nitrite and nitrate, defined as three times the standard deviation of measured blanks are 2.9 ng NO2-N ml−1 and 2.3 ng NO3-N ml−1, respectively. Up to 20 samples can be analyzed per hour with a relative standard deviation of less than 1.5%. The proposed method could be applied successfully to the simultaneous determination of nitrite and nitrate in water samples.  相似文献   

9.
A two-dimensional biomimetic optrode for the detection and quantification of uranium in natural waters was fabricated. The sensing element was designed by the inclusion of uranyl ion imprinted polymer particles into polymethyl methacrylate followed by casting a thin film on a glass slide without any plasticizer. The ion imprinted polymer material was prepared via covalent immobilization of the newly synthesised ligand 4-vinyl phenylazo-2-naphthol by thermal polymerization. Operational parameters such as pH, response time and the amount of sensing material were optimized. The response characteristics of the imprinted and the corresponding non-imprinted polymer inclusion optrodes of uranium were compared under optimum conditions. The imprinted polymer inclusion optrode responds linearly to uranium in the concentration range 0–1.0 μg mL−1 with a detection limit of 0.18 μg mL−1, which is much better than the solution studies using 4-vinyl phenylazo-2-naphthol (1.5 μg mL−1). Triplicate determinations of 100 μg of uranium(VI) present in 250 mL of solution gave a mean absorbance of 0.018 with a relative standard deviation of 8.33%. The superior sensitivity of imprinted polymer inclusion optrode is exemplified by lower detection limits and broader dynamic range over non-imprinted polymer inclusion optrode. The developed imprinted polymer inclusion optrode was found to give stable and precise response for 3 months and can be used without any loss in sensitivity. The applicability for analysing ground, lake and tap-water samples collected in the vicinity of uranium deposits was successfully demonstrated.  相似文献   

10.
Du D  Ding J  Cai J  Zhang J  Liu L 《Talanta》2008,74(5):1337-1343
Gold nanoparticles (AuNPs) were synthesized in situ and electrodeposited onto Au substrate. The AuNPs modified interface facilitates electron transfer across self-assembled monolayers (SAMs) of 11-mercaptoundecanoic acid (MUA). After activation of surface carboxyl groups with 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide and N-hydroxysuccinimide, the interface displayed good stability for immobilization of biomolecules. These modification processes were characterized by contact angle measurement, cyclic voltammetry and electrochemical impedance spectra. The immobilized acetylcholinesterase (AChE), as a model, showed excellent activity to its substrate, leading to a stable AChE biosensor. Under the optimal experimental conditions, the inhibition of malathion on AChE biosensor was proportional to its concentration in two ranges, from 0.001 to 0.1 μg mL−1 and from 0.1 to 25 μg mL−1, with detection limit of 0.001 μg mL−1. The simple method showed good reproducibility and acceptable stability, which had potential application in biosensor design.  相似文献   

11.
Analytical procedure for the determination of toxicologically relevant arsenic (the sum of arsenite, arsenate, monomethylarsonate and dimethylarsinate) in urine by flow injection hydride generation and collection of generated inorganic and methylated hydrides on an integrated platform of a transverse-heated graphite atomizer for electrothermal atomic absorption spectrometric determination (ETAAS) is elaborated. Platforms are pre-treated with 2.7 μmol of zirconium and then with 0.10 μmol of iridium which serve both as an efficient hydride sequestration medium and permanent chemical modifier. Arsine, monomethylarsine and dimethylarsine are generated from diluted urine samples (10–25-fold) in the presence of 50 mmol L−1 hydrochloric acid and 70 mmol L−1 l-cysteine. Collection, pyrolysis and atomization temperatures are 450, 500, 2100 and 2150 °C, respectively. The characteristic mass, characteristic concentration and limit of detection (3σ) are 39 pg, 0.078 μg L−1 and 0.038 μg L−1 As, respectively. The limits of detection in urine are ca. 0.4 and 1 μg L−1 with 10- and 25-fold dilutions. The sample throughput rate is 25 h−1. Applications to several urine CRMs are given.  相似文献   

12.
An analytical method for analysing acrylamide in coffee was validated. The analysis of prepared coffee includes a comprehensive clean-up using multimode solid-phase extraction (SPE) by automatic SPE equipment and detection by liquid chromatography tandem mass spectrometry using electrospray in the positive mode. The recoveries of acrylamide in ready-to-drink coffee spiked with 5 and 10 μg l−1 were 96±14% and 100±8%, respectively. Within laboratory reproducibility for the same spiking levels were 14% and 9%, respectively. Coffee samples (n = 25) prepared twice by coffee machines and twice by a French Press Cafetière coffee maker contained 8±3 μg l−1 and 9±3 μg l−1 acrylamide. Five ready-to-drink instant coffee prepared twice contained 8±2 μg l−1. Hence, the results do not show significant differences in the acrylamide contents in ready-to-drink coffee prepared by coffee machine, French Press or from instant coffee. Medium roasted coffee contained more acrylamide (10 μg l−1) than dark roasted coffee (5 μg l−1). Males aged 35–45 years, drinking on average 1.1 l coffee per day are exposed to the highest doses of acrylamide from coffee. The dietary intake of acrylamide from coffee comprises, on an average, 10 μg day−1 for males and 9 μg day−1 for females aged 35–45 years. Probabilistic modelling of the exposure of Danish consumers (all adults) to acrylamide from coffee shows a mean exposure of 6.5 μg day−1 and a 95 percentile of 18 μg day−1.  相似文献   

13.
A new sensitive and selective preconcentration-fluorimetric method for determination of terazosin based on its native fluorescence was developed. The analyte, initially present in aqueous matrix, was treated with an extractive non-ionic surfactant solution and separated by the clouding phenomenon. The optimum analytical conditions for terazosin assay were established. Under these conditions, linear calibration curves were obtained over the range of 1 × 10−5 to 7.0 μg mL−1 with detection and quantification limits of 1.11 × 10−5 and 3.7 × 10−5 μg mL−1, respectively. Additionally, the binding constant (KB) for the terazosin-PONPE 7.5 system was determined given a value of 1028 L mol−1. The developed coupled methodology, which thoroughly satisfies the typical requirements for pharmaceutical control processes, was proved to be appropriate for monitoring terazosin in actual pharmaceutical formulations and biological fluid sample. The results were validated by recovery test and by comparison with other reported methods, being highly satisfactory.  相似文献   

14.
A sensitive and specific monoclonal ELISA for the determination of tissue bound furazolidone metabolite 3-amino-2-oxazolidinone (AOZ) is described. The procedure enables the detection of AOZ in matrix supernatant after homogenisation, protease treatment, acid hydrolysis and derivatisation of AOZ released from the tissue by o-nitrobenzaldehyde. The formed p-nitrophenyl 3-amino-2-oxazolidinone (NPAOZ) is determined by ELISA calibrated with matrix-matched standards in the concentration range of 0.05–5.0 μg I−1. The assay was validated according to criteria set down by Commission Decision 2002/657/EC for the performance and validation of analytical methods for chemical residues. Detection capability, set on the basis of acceptance of no false negative results, was 0.4 μg kg−1 for shrimp, poultry, beef and pork muscle. This sensitivity approaches the established confirmatory LC–MS/MS able to quantify tissue-bound AOZ at levels as low as 0.3 μg kg−1. An excellent correlation of results obtained by ELISA and LC/MS–MS within the concentration range 0–32.1 μg kg−1 was found in the naturally contaminated shrimp samples (r = 0.999, n = 8). A similar correlation was found for the incurred poultry samples within the concentration range of 0–10.5 μg kg−1 (r = 0.99, n = 8).  相似文献   

15.
In this paper we have coupled, for the first time, chemiluminescent detection with multicommuted optosensing principles. This approach has been implemented with the use of a commercial flow cell of 1 mm optical path length filled with an appropriate anionic exchanger gel as chemiluminescence sensing phase. The cell was placed in front of the window of the photosensor module of a home-made luminometer developed in our laboratory and a flat mirror was stuck on the back of the cell. The suitability of using chemiluminescence as detection technique in multicommuted flow-through optosensors has been demonstrated: the determination of salicylic acid by simple oxidation with permanganate on the sensing solid phase was chosen as model reaction. The proposed system allows the determination of salicylic acid in pharmaceuticals, with a sample frequency as high as even 60 samples h−1 and showing a detection limit of 0.30 μg mL−1, the linear response range is 1–30 μg mL−1 and the R.S.D. is 3.1%. Satisfactory results have been obtained when applying the sensor to pharmaceuticals. The accuracy of the proposed methodology has been tested by using a reference method.  相似文献   

16.
Soylak M  Tuzen M  Mendil D  Turkekul I 《Talanta》2006,70(5):1129-1135
A solid phase extraction procedure based on biosorption of copper(II), lead(II), zinc(II), iron(III), nickel(II) and cobalt(II) ions on Aspergillus fumigatus immobilized Diaion HP-2MG has been investigated. The analytical conditions including amounts of A. fumigatus, eluent type, flow rates of sample and eluent solutions were examined. Good recoveries were obtained to the spiked natural waters. The influences of the concomitant ions on the retentions of the analytes were also examined. The detection limits (3sigma, N = 11) were 0.30 μg l−1 for copper, 0.32 μg l−1 for iron, 0.41 μg l−1 for zinc, 0.52 μg l−1 for lead, 0.59 μg l−1 for nickel and 0.72 μg l−1 for cobalt. The relative standard deviations of the procedure were below 7%. The validation of the presented procedure is performed by the analysis of three standard reference materials (NRCC-SLRS 4 Riverine Water, SRM 1515 Apple leaves and GBW 07605 Tea). The procedure was successfully applied for the determination of analyte ions in natural waters microwave digested samples including street dust, tomato paste, black tea, etc.  相似文献   

17.
A pervaporation-flow injection (PFI) method is described for the analysis of cyanide in the presence of sulfide. The interfering sulfide ion in the injected sample is precipitated on-line using an acidified lead nitrate reagent solution before the donor stream enters the pervaporation cell. Using amperometric detection at a silver electrode set at −50 mV (vs Ag/AgCl), linear calibration was obtained in the range 0.02–100.0 mg l−1 with a detection limit of 1.0 μg l−1. Sample throughput was of the order of 12–15 h−1. When the method was applied to the analysis of synthetic samples, there was no significant interference from sulfide at concentrations up to 50 mg l−1. Thiocyanate did not interfere at levels up to 1000 mg l−1. When applied to industrial samples containing sulfide and thiocyanate ions where the cyanide ions are predominantly complexed with various metal ions the PFI method was found to give results close to those obtained by standard distillation methods for weak acid dissociable (WAD) cyanide.  相似文献   

18.
A flow system with a multi-channel peristaltic pump placed before the solenoid valves is proposed to overcome some limitations attributed to multi-commuted flow injection systems: the negative pressure can lead to the formation of unwanted air bubbles and limits the use of devices for separation processes (gas diffusion, dialysis or ion-exchange). The proposed approach was applied to the colorimetric determination of ammonium nitrogen. In alkaline medium, ammonium is converted into ammonia, which diffuses over the membrane, causing a pH change and subsequently a colour change in the acceptor stream (bromothymol blue solution). The system allowed the re-circulation of the acceptor solution and was applied to ammonium determination in surface and tap water, providing relative standard deviations lower than 1.5%. A stopped flow approach in the acceptor stream was adopted to attain a low quantification limit (42 μg L−1) and a linear dynamic range of 50–1000 μg L−1 with a determination rate of 20 h−1.  相似文献   

19.
Cao Q  Li S  He C  Li K  Liu F 《Analytica chimica acta》2007,590(2):187-194
Based on aqueous two-phase system (ATPS) of poly(ethylene glycol) (PEG)–(NH4)2SO4, a simple pretreatment approach was developed for the extraction and determination of papaverin in pericarpium papaveris. The influence factors on phase behavior of the ATPS and partition behavior of papaverin was investigated, and partition mechanism based on the hydrophobic interaction between PEG and analyte molecules was proposed. Under the optimal conditions, the extraction efficiencies for papaverin were 93–96%, and the recoveries of the added standard were 97–106% with relative standard deviations of 1.8–2.5%. Combined with a high-performance liquid chromatography (HPLC) method, this extraction technique has been successfully applied to the determination of papaverin in pericarpium papaveris with the detection limit of 2 ng mL−1 and the linear range of 0.10–10 μg mL−1. Compared with the conventional liquid–liquid extraction or solid-phase extraction, this method was more environmentally benign, more cost effective and much simpler due to the direct injection of the upper phase into HPLC system.  相似文献   

20.
A sequential injection analysis (SIA) spectrophotometric method for the determination of trace amounts of zinc(II) with 1-(2-pyridylazo)-2-naphthol (PAN) is described. The method is based on the measurement of absorbance of the zinc(II)–PAN chelate solubilized with a non-ionic surfactant, Triton X-100, no extraction procedure is required in the proposed method, yielding a pink colored complex at pH 9.5 with absorption maximum at 553 nm. The SIA parameters that affect the signal response have been optimized in order to get the better sensitivity and minimum reagent consumption. A linear relationship between the relative peak height and concentration was obtained in the concentration range of 0.1–1.0 μg ml−1. The limit of detection (LOD, defined as 3σ) and limit of quantification (LOQ, defined as 10σ) were 0.02 and 0.06 μg ml−1, respectively. The sample throughput about 40 samples/h was obtained. The repeatability were 1.32 and 1.24% (n = 10) for 0.1 and 0.5 μg ml−1, respectively. The proposed method was successfully applied to the assay of zinc(II) in three samples of multivitamin tablets. The results were found to be in good agreement with those obtained by flame atomic absorption spectrophotometric method and with the claimed values by the manufactures. The t-test showed no significant difference at 95% confidence level.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号