1.
(Simultaneous determination of trace elements in high-purity chromium by inductively-coupled plasma/atomic emission spectrometry after matrix separation.) The production of high-purity metals requires routine determinations of elements in the ng g?1 range. Procedures based on wet chemical separation of matrix and trace elements followed by inductively-coupled plasma/atomic emission spectrometry are suitable. The separation of 19 trace metals (Be, Bi, Ca, Cd, Co, Cu, Fe, La, Mg, Mn, Nb, Ni, Pb, Ta, Ti, Th, U, Zn and Zr) from high-purity chromium powder is described. The powder is dissolved in hydrochloric acid and oxidized with perchloric acid or alkaline hydrogen peroxide, and the trace elements are precipitated at pH 11–13 and collected on cellulose loaded with indium hydroxide or on cellulose-Hyphan. The detection limits of the total procedure vary from 10 ng g?1 for cadmium to 600 ng g?1 for zinc.  相似文献   

2.
Flow injection iminodiacetic acid ethyl cellulose (IDAEC) microcolumn preconcentration and graphite furnace atomic absorption spectrometry determination of trace metals (Cd, Co, Ni, Pb) were carried out without decomposition of the drug matrix. The two forms of chromium Cr(III) and Cr(VI) were separated using IDAEC and anion exchanger diethylaminoethyl (DE)-cellulose, respectively. The detection limits of trace elements in pharmaceutical substances (sugars, sorbitol, mannitol, paracetamol, amidopyrine, chloral hydrate) after a 10-fold preconcentration in 1–5% m/v solution of pharmaceuticals were in the 0.3–29 ng g−1 range. The measured concentration of trace elements in substances investigated was below 100 ng g−1. The spike recovery was close to 100%. The capability of total reflection X-ray fluorescence technique for the determination of trace elements in pharmaceuticals with and without preconcentation was explored.  相似文献   

3.
When determining element contents in hair samples without sample digestion it is necessary to analyze large sample volumes in order to minimize problems of inhomogeneity of biological sample materials. Therefore an electrothermal vaporization system (ETV) is used for solid sample introduction into an inductively coupled plasma (ICP) for the determination of matrix and trace elements in hair. This paper concentrates on the instrumental aspects without time consuming sample preparation. The results obtained for optimization tests, ETV operating parameters and ICP operating parameters, are shown and discussed. Standard additions are used for calibration for the determination of Zn, Mg, and Mn in human hair. Studies including reproducibility and detection limits for chosen elements have been carried out on certified reference materials (CRMs). The determination of reproducibility (relative standard deviation (RSD) of n = 10) and detection limits (DLs) of Zn (RSD < 8.5%, DL < 0.8 μ g−1), Mn (RSD < 14.1%, DL < 0.3 μ g−1), and Mg (RSD < 7.4%, DL < 6.6 μ g−1) are satisfactory. The concentration values found show good agreement with the corresponding certified values. Further sample preparation steps, including hair sampling, washing procedure and homogenization for hair, relating to measurements of real hair samples are described.  相似文献   

4.
An inductively coupled plasma-atomic emission spectrometry (ICP-AES) method is developed for determination of Cd, Co, Cr, Cu, Ni, Tl and Zn in traces in calcite, CaCO3, dolomite, CaMg(CO3)2, and gypsum, CaSO4. Interferences of a Ca/Mg matrix on analyte intensities were investigated. The results reveal that Ca does not interfere with Cr, Ni and Zn, but tends to decrease the intensity of the other elements. Magnesium as a matrix element does not interfere on with Zn, but increases the intensities of Ni, Cr and Cu, and decreases the intensities of Cd, Co and Tl. To eliminate these matrix interferences on trace element intensities, a flotation separation method is proposed. Lead(II) hexamethylenedithiocarbamate, Pb(HMDTC)2, is applied as a collector for flotation of trace elements from acidic solutions of mineral samples. The flotation of acidic aqueous solutions of calcite, dolomite and gypsum was performed at pH 6.0, using 10 mg l−1 Pb and 0.3 mmol l−1 HMDTC added to 1 l of solution tested. The method detection limits of analytes in different minerals range from 0.02 to 0.06 μg g−1 for Cd, 0.04 to 0.10 μg g−1 for Co, 0.03 to 0.13 μg g−1 for Cr, 0.02 to 0.16 μg g−1 for Cu, 0.09 to 0.30 μg g−1 for Ni, 6.45 to 7.71 μg g−1 for Tl and 0.18 to 0.20 μg g−1 for Zn.  相似文献   

5.
Besides atomic absorption spectrometry, the plasma techniques can be seen as state-of-the-art instrumentation in an industrial laboratory for the analysis of trace elements today. For the analysis of refractory metals, e.g. Mo and W, the determination limits which can be reached by ICP-AES techniques are mainly restricted by the spectral background of the matrix. Advantages and disadvantages of sequential and simultaneous detection as well as different methods of evaluation, such as Kaiman filtering and multiple component spectral fitting, are discussed. The results are compared with trace matrix separation techniques and on-line coupling of ion chromatography with ICP-AES and ICP-MS. Furthermore, the limitations of all techniques with respect to their applicability for routine analysis, especially the complexity of sample preparation, degree of automation, time consumption and cost are shown. With respect to the detection capability, TMS with ICP-MS end determination is the most powerful technique, but for routine analysis simultaneous multielement determination from the matrix is favourable.  相似文献   

6.
A new method has been developed for the determination of trace rare earth elements (REEs) in water samples based on preconcentration with a microcolumn packed with multiwalled carbon nanotubes (MWNTs) prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The optimum experimental parameters for preconcentration of REEs, such as pH of the sample, sample flow rate and volume, elution solution and interfering ions, have been investigated. The studied REEs ions can be quantitatively retained by MWNTs when the pH exceed 3.0, and then eluted completely with 1.0 mol L−1 HNO3. The detection limits of this method for REEs was between 3 and 57 ng L−1, and the relative standard deviations (RSDs) for the determination of REEs at 10 ng mL−1 level were found to be less than 6% when processing 100 mL sample solution. The method was validated using a certified reference material, and has been successfully applied for the determination of trace rare earth elements in lake water and synthetic seawater with satisfactory results.  相似文献   

7.
Mass spectrometric methods for the trace analysis of inorganic materials with their ability to provide a very sensitive multielemental analysis have been established for the determination of trace and ultratrace elements in high-purity materials (metals, semiconductors and insulators), in different technical samples (e.g. alloys, pure chemicals, ceramics, thin films, ion-implanted semiconductors), in environmental samples (waters, soils, biological and medical materials) and geological samples. Whereas such techniques as spark source mass spectrometry (SSMS), laser ionization mass spectrometry (LIMS), laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS), glow discharge mass spectrometry (GDMS), secondary ion mass spectrometry (SIMS) and inductively coupled plasma mass spectrometry (ICP-MS) have multielemental capability, other methods such as thermal ionization mass spectrometry (TIMS), accelerator mass spectrometry (AMS) and resonance ionization mass spectrometry (RIMS) have been used for sensitive mono- or oligoelemental ultratrace analysis (and precise determination of isotopic ratios) in solid samples. The limits of detection for chemical elements using these mass spectrometric techniques are in the low ng g−1 concentration range. The quantification of the analytical results of mass spectrometric methods is sometimes difficult due to a lack of matrix-fitted multielement standard reference materials (SRMs) for many solid samples. Therefore, owing to the simple quantification procedure of the aqueous solution, inductively coupled plasma mass spectrometry (ICP-MS) is being increasingly used for the characterization of solid samples after sample dissolution. ICP-MS is often combined with special sample introduction equipment (e.g. flow injection, hydride generation, high performance liquid chromatography (HPLC) or electrothermal vaporization) or an off-line matrix separation and enrichment of trace impurities (especially for characterization of high-purity materials and environmental samples) is used in order to improve the detection limits of trace elements. Furthermore, the determination of chemical elements in the trace and ultratrace concentration range is often difficult and can be disturbed through mass interferences of analyte ions by molecular ions at the same nominal mass. By applying double-focusing sector field mass spectrometry at the required mass resolution—by the mass spectrometric separation of molecular ions from the analyte ions—it is often possible to overcome these interference problems. Commercial instrumental equipment, the capability (detection limits, accuracy, precision) and the analytical application fields of mass spectrometric methods for the determination of trace and ultratrace elements and for surface analysis are discussed.  相似文献   

8.
Solid sampling graphite furnace atomic absorption spectrometry (SS-GF AAS) was investigated as a potential technique for the routine determination of trace elements in mineral coal and cadmium, copper and lead were chosen as the model elements. Cadmium and lead could be determined at their main resonance lines at 228.8 nm and 283.3 nm, respectively, but an alternate, less sensitive line had to be used for the determination of copper because of the high copper content in coal. No modifier was necessary for the determination of copper and calibration against aqueous standards provided sufficient accuracy of the results. For the determination of cadmium and lead two different modifiers were investigated, palladium and magnesium nitrates in solution, added on top of each sample aliquot before introduction into the atomizer tube, and ruthenium as a ‘permanent’ modifier. Both approaches gave comparable results, and it is believed that this is the first report about the successful use of a permanent chemical modifier in SS-GF AAS. Calibration against solid standards had to be used for the determination of cadmium and lead in order to obtain accurate values. The agreement between the values found by the proposed procedure and the certificate values for a number of coal reference materials was more than acceptable for routine purposes. The detection limits calculated for 1 mg of coal sample using the ‘zero mass response’ were 0.003 and 0.007 μg g−1 for cadmium with the permanent modifier and the modifier solution, respectively, approximately 0.04 μg g−1 for lead, and 0.014 μg g−1 for copper.  相似文献   

9.
The determination of metal-cofactors and their molar concentrations is an important requirement for the characterisation of metalloproteins and a challenge regarding the capabilities of trace analytical methods. In this respect, total-reflection X-ray fluorescence spectrometry offers many advantages for the determination of trace elements in enzymes, as compared to other well known analytical techniques such as flame atomic absorption spectrometry or inductively coupled plasma atomic emission spectrometry (ICP-AES), because of the significantly smaller amounts of sample required. Without any decomposition, elements like P, S, Fe, Ni, Cu, Zn, Mn and Mo could be determined with high accuracy, in spite of the large bio-organic matrix. The enzymes (polysulphide reductase and hydrogenase of the rumen bacterium Wolinella succinogenes, and the cytochrome c oxidase and quinol oxidase of the soil bacterium Paracoccus denitrificans) were transferred from their usual salt-buffer into a solution of 100 mmol l−1 tris(hydroxymethyl)aminomethane (tris)-acetate containing an appropriate detergent. By this procedure, an improved signal-to-noise ratio is obtained. The polysulphide reductase was found to contain copper as a hitherto existing unknown cofactor. The enzyme contains a stretch of amino acids that are typical of copper proteins and thus confirm the presence of this element. Furthermore, the data concerning cytochrome c oxidase from Paracoccus denitrificans are in good agreement with published values obtained by ICP-AES. Also, results from measurements with the quinol oxidase from the same bacterium agree with the expected values. The investigations lead to the conclusion that the method is well suited to the quantitative determination of metals in enzymes, in particular their molar fractions, and requires only small amounts of the biological sample without any extensive pretreatment. © 1997 Elsevier Science B.V.  相似文献   

10.
On-line system incorporating a microcolumn of Muromac A-1 resin was used for the developing of method for preconcentration of trace elements followed by inductively coupled plasma (ICP) atomic emission spectrometry determination. A chelating type ion exchange resin has been characterized regarding the sorption and subsequent elution of 24 elements, aiming to their preconcentration from water samples of different origins. The effect of column conditioning, pH and flow rate during the preconcentration step, and the nature of the acid medium employed for desorption of the retained elements were investigated. A sample (pH 5) is pumped through the column at 3 ml min−1 and sequentially eluted directly to the ICP with 3 M HNO3/HCl mixtures. In order to remove residual matrix elements from the column after sample loading a short buffer wash was found to be necessary. The effectiveness of the matrix separation process was illustrated. The procedure was validated by analyzing several simple matrices, Standard River water sample as well as artificial seawater. Proposed method can be applied for simultaneous determination of In, Tl, Ti, Y, Cd, Co, Cu and Ni in seawater and for multielement trace analysis of river water. Recovery at 1 μg l−1 level for the determination of investigated 24 elements in pure water ranged from 93.1 to 96% except for Pd (82.2%) and Pb (88.1%). For the same concentration level for seawater analysis recovery was between 81.9 and 95.6% except for Hg (38.2%).  相似文献   

11.
The economic and geological importance of platinum group of elements has led to the development of analytical methods to quantify them in different types of samples. In the present paper the quantitative information for spectral interference in radial viewing 40.68 MHz inductively coupled plasma atomic emission spectrometry in the determination of Pt, Pd and Rh in the presence of complex matrix, containing Al, Ca, Fe, Mg, Mn, P and Ti as matrix constituents was obtained. The database was used for optimum line selections. By using the selected analysis lines the following detection limits in ng g− 1 were obtained: Pt 1700, Pd-1440, Rh-900. The reached detection limits determine the possibilities and limitation of the direct ICP-AES method in the determination of Pt, Pd and Rh in geological and environmental materials. The database for spectral interferences in the presence of aluminum can be used for the determination of platinum group of elements in car catalysts.  相似文献   

12.
Nowadays much attention is being paid to the determination of trace amounts of noble metals in geological, industrial, biological and environmental samples. The most promising techniques, such as inductively coupled plasma atomic emission spectrometry (ICP-AES), inductively coupled plasma mass spectrometry (ICP-MS) and electrothermal atomic absorption spectrometry (ETAAS) are characterized by high sensitivity. However, the accurate determination of trace noble metals has been limited by numerous interferences generated from the presence of matrix elements. To decrease, or eliminate, these interferences, the sorption preconcentration of noble metals is often used prior to their instrumental detection. A great number of hyphenated methods of noble metal determination using sorption preconcentration have been developed. This review describes the basic types of available sorbents, preconcentration procedures and preparations of the sorbent to the subsequent determination of noble metals. The specific features of instrumental techniques and examples of ETAAS, FAAS, ICP-AES, ICP-MS determinations after the sorption preconcentration of noble metals are considered. The references cited here were selected mostly from the period 1996 - 2006.  相似文献   

13.
A chitosan resin possessing a phenylarsonic acid moiety (phenylarsonic acid type chitosan resin) was developed for the collection and concentration of trace uranium prior to inductively coupled plasma (ICP) atomic emission spectrometry (AES) measurement. The adsorption behavior of 52 elements was systematically examined by packing it in a minicolumn and measuring the elements in the effluent by ICP mass spectrometry. The resin could adsorb several cationic species by a chelating mechanism, and several oxo acids, such as Ti(IV), V(V), Mo(VI), and W(VI), by an anion-exchange mechanism and/or a chelating mechanism. Especially, U(VI) could be adsorbed almost 100% over a wide pH region from pH 4 to 8. Uranium adsorbed was easily eluted with 1 M nitric acid (10 mL), and the 25-fold preconcentration of uranium was achieved by using a proposed column procedure, which could be applied to the determination of trace uranium in seawater by ICP-AES. The limit of detection was 0.1 ng mL−1 for measurement by ICP-AES coupled with 25-fold column preconcentration.  相似文献   

14.
To an iron sample solution was added polyoxyethylene-4-isononylphenoxy ether (PONPE, nonionic surfactant, average number of ethylene oxides 7.5) and the surfactant was aggregated by the addition of lithium chloride. The iron(III) matrix was collected into the condensed surfactant phase in >99.9% yields, leaving trace metals [e.g., Ti(IV), Cr(III), Mn(II), Co(II), Ni(II), Cu(II), Zn(II), Cd(II), Pb(II), and Bi(III)] in the aqueous phase. After removing the surfactant phase by centrifugation, the remaining trace metals were concentrated onto an iminodiacetic acid-type chelating resin. The trace metals were desorbed with dilute nitric acid for the determination by inductively coupled plasma-mass spectrometry or graphite-furnace atomic absorption spectrometry. The proposed separation method allowed the analysis of high-purity iron metals for trace impurities at low μg g−1 to ng g−1 levels.  相似文献   

15.
A chelating matrix prepared by immobilising folic acid on silica gel-bound amine phase was used as a new solid-phase extractant. This sorbent has been developed only for preconcentration of trace Pb(II) prior to determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). Experimental conditions were investigated by batch and column procedures. The optimum pH value for the separation of Pb(II) on the new sorbent was 4.0. The adsorbed Pb(II) was quantitatively eluted by 2.0?cm3 of 0.5?mol?dm?3 of HCl. Common coexisting ions did not interfere with the separation and determination of Pb(II). The maximum static adsorption capacity of the sorbent under optimum conditions was found to be 69.23?mg?g?1 for Pb(II). The detection limit of the method defined by International Union of Pure and Applied Chemistry was 0.28?ng?cm?3. The relative standard deviation (RSD) of the method was lower than 2.0% (n?=?8). The developed method has been validated by analysing certified reference materials and successfully applied to the determination of Pb(II) in water samples with satisfactory results.  相似文献   

16.
A method has been developed for the determination of Al, Cd, Cr, Cu, Fe, Mg, Mn, Ni, Sb, Sn and Zn at trace levels in high purity di-boron trioxide using ETAAS. The boron trioxide matrix was eliminated as trimethyl borate ester in a multiplex vapor phase matrix extraction (MVPME) device using a mixture of glycerol and methanol. In this MVPME device, in situ reagent purification, sample digestion and simultaneous matrix elimination were achieved by a single step in closed condition, which in combined effect reduce the process blanks. The matrix extraction procedure allows determination of trace elemental impurities by electrothermal atomic absorption spectrometry (ETAAS) with fast furnace analysis (without an ashing step and modifier) and calibration against aqueous standards. The performance and accuracy of the vapor phase matrix elimination technique are compared to those of suprapur grade hydrofluoric acid solution in two ways; (i) matrix separation as BF3 over hot plate and (ii) in situ matrix elimination inside graphite furnaces. The method detection limits calculated from blank samples are in the range of 0.5 (Ni) and 2.9 (Al) ng g−1. Thus the MVPME-based sample preparation approach is well suited for the trace analysis of high purity di-boron trioxide used in microelectronics applications.  相似文献   

17.
A method for the direct determination of trace rare earth elements in ancient porcelain samples by slurry sampling fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry was developed with the use of polytetrafluoroethylene as fluorinating reagent. It was found that Si, as a main matrix element in ancient porcelain sample, could be mostly removed at the ashing temperature of 1200 °C without considerable losses of the analytes. However, the chemical composition of ancient porcelain sample is very complicated, which makes the influences resulting from other matrix elements not be ignored. Therefore, the matrix effect of ancient porcelain sample was also investigated, and it was found that the matrix effect is obvious when the matrix concentration was larger than 0.8 g l 1. The study results of particle size effect indicated that when the sample particle size was less than 0.057 mm, the particle size effect is negligible. Under the optimized operation conditions, the detection limits for rare earth elements by fluorinating electrothermal vaporization inductively coupled plasma mass spectrometry were 0.7 ng g 1 (Eu)–33.3 ng g 1(Nd) with the precisions of 4.1% (Yb)–10% (La) (c = 1 μg l 1, n = 9). The proposed method was used to directly determine the trace rare earth elements in ancient porcelain samples produced in different dynasty (Sui, Ming and Qing), and the analytical results are satisfactory.  相似文献   

18.
In this study, a new device was applied for direct solid sampling flame atomic absorption spectrometry. It was used for trace determination of cadmium in biological samples (bovine and chicken liver). Test samples (0.5 to 7 mg) were weighed into small paper capsules, which were introduced into a quartz cell heated by an air-acetylene flame. Operational conditions for the proposed system were evaluated. There was no significant difference between the results obtained with the proposed system and those obtained after digestion and determination by conventional graphite furnace atomic absorption spectrometry. Good agreement was also obtained with the certified values of two reference materials. Background signals were always low. The characteristic mass was 0.34 ng and relative standard deviation was less than 8%. The limit of detection for the proposed procedure was 1.6 ng or 0.23 μg g 1 if a sample mass of 7 mg was used. Excluding the steps for sample preparation (drying, milling and weighing), the proposed system allows the determination of 40 test samples per hour and it can be easily adapted to conventional flame atomic absorption spectrometers.  相似文献   

19.
A novel method for the determination of trace rare earth impurities in ZrO2 powder has been developed based on electrothermal vaporization inductively coupled plasma atomic emission spectrometry. A polytetrafluoroethylene slurry was used as a fluorinating reagent to convert both the matrix (Zr) and the analytes (rare earth elements) into fluorides with different volatilities at a high temperature in a graphite furnace. The more volatile ZrF4 was removed in-situ by selective vaporization prior to the determination of the analytes, removing matrix spectral interferences. Under optimum operating conditions, the absolute detection limits of the analytes varied from 0.04 ng (Yb) to 0.50 ng (Pr) with relative standard deviations less than 5%. The recommended approach has been successfully applied to the determination of trace rare earth impurities (La, Pr, Eu, Gd, Ho and Yb) in ZrO2 powder and the results were in good agreement with those obtained by pneumatic nebulization inductively coupled plasma atomic emission spectrometry after the separation of the matrix using a solvent extraction procedure.  相似文献   

20.
Three multielement methods: (1) inductively coupled plasma mass spectrometry (ICP-MS), (2) inductively coupled plasma atomic emission spectroscopy (ICP-AES), and (3) spark source mass spectrometry (SSMS) were used for the determination of additives in the samples of germanium and germanium oxide. The detection limits of direct SSMS and ICP-AES/ICP-MS were compared using the autoclave predissolution of germanium and germanium dioxide samples. It was shown that in the latter case, the detection limits could be significantly improved by the separation of germanium from analytes by distillation. In this case, the detection limits of such limiting elements like Th and U can reach the level n 10?10 wt %.  相似文献   