首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 203 毫秒
1.
A multi-tube Nafion® membrane dryer used as a part of a desolvation system in conjunction with thermospray nebulization was optimized and characterized with inductively coupled plasma-atomic emission spectrometry (ICP-AES). Either argon or nitrogen could be used as the sweep gas, and optimum conditions were found to be at low temperature and low sweep gas flow rate. Analyte sensitivity was not significantly affected by placing the membrane between the plasma and the nebulizer, although about 20% of the analyte entering the dryer is lost within the dryer. A dual role of the membrane dryer was demonstrated. As a secondary step within the desolvation system, it enabled a high desolvation efficiency of 99.94% for aerosols from 1% (v/v) nitric acid. Plasma solvent load could be reduced to 0.9 mg min−1 with a tap water cooled condenser combined with the membrane dryer, compared to 21 mg min−1 with the normal chilled condenser desolvation system. Meanwhile, the membrane was also found to act as a pulse dampener, eliminating the plasma pulsation in the central channel caused by thermospray nebulization and thus improving the analytical performance of the system. The average relative standard deviations (RSD) with the optimized membrane/thermospray system were 0.83% and 0.60% for the background and analyte signals, respectively, which were reduced by a factor of 1.9 and 2.7 for the background and analyte signals, respectively, compared to thermospray without the membrane desolvation, and were essentially identical to those obtained with pneumatic nebulization sample introduction. The improvements in detection limits with the membrane/thermospray system were 1.2–3.0 times with an average factor of 1.8 compared to thermospray without the membrane dryer, and 18–68 times with an average factor of 39 compared to the standard pneumatic nebulization sample introduction system without a desolvation unit. The detection limits for Mn, Mg, Cr and Cd with the present thermospray/membrane system were comparable to those reported for pneumatic nebulization ICP mass spectrometry.  相似文献   

2.
等离子体原子光谱分析中溶液样品雾化进样方法的新进展   总被引:1,自引:0,他引:1  
对近年来等离子体原子光谱分析中溶液样品引入方法的新进展作了综述,其中包括气动雾化法、超声雾化法、热雾化法、悬浆雾化法、高水压雾化法及电喷雾法等。文中还根据本课题组多年来的研究经验对每种方法的优缺点及其应用作了简要的介绍和评论。  相似文献   

3.
Combined liquid chromatography and mass spectrometry is frequently performed with the thermospray interface nowadays. With thermospray a special ion source has to be installed. Tuning and calibration of that special source is still a problem which has not been adequately solved, Reference compounds commonly used in conventional electron impact or chemical ionization mass spectrometry cannot be used in the thermospray source. Most of the solutions to this problem reported in the literature cause a rapid contamination of the ion source or may result in memory effects. In this paper the use of acetic acid ammonia cluster ions is proposed for tuning and calibration in thermospray. Abundant cluster ions can be observed over the mass range between m/z = 100 and 1000 when an eluent containing ammonium acetate and 0.5% acetic acid is used. Features of the mass spectra obtained in both filament-off, filament-on and discharge-on modes will be discussed.  相似文献   

4.
Two conjugated metabolites of methapyrilene hydrochloride isolated from mouse-hepatocytes were examined by mass spectrometry using fast-atom bombardment (FAB) and thermospray ionization. The major metabolite, methapyrilene glucuronide, was identified based on a prominent peak due to the protonated molecule as well as the loss of the dimethylamine and sugar moieties. Identification of the second metabolite was complicated by large signals associated with the biological sample matrix. The complementary nature of the fragmentation observed in the mass spectra using FAB and thermospray ionization allowed this metabolite to be identified as the desmethylmethapyrilene glucuronide. The fragmentation observed using FAB ionization was not greatly affected by the presence of the glucuronide moiety. While loss of the sugar moiety indicated a glucuronide, additional fragmentation confirmed the presence of the underlying ethylenediamine substructure which is characteristic of this class of antihistamines.  相似文献   

5.
Enrichment on Chelex-100, followed by evaporation when necessary, was used for the pre-concentration of Cd, Pb, Cu and Zn from natural waters. The measurements were carried out with inductively coupled plasma atomic emission spectrometry using a thermospray nebulisation system to reach the required sensitivity. The detection limits corresponding to three times the standard deviation of the blank (in 1% v/v HNO3) after a 30-fold enrichment are 0.02 microgram l-1 for Cd, 0.33 microgram l-1 for Pb and 0.03 microgram l-1 for Cu and Zn. Matrix effects, which are fairly serious with thermospray nebulisation, were taken into account by using the standard additions method. Results obtained for several river water samples were compared with those found by analysis of the non-enriched sample with inductively coupled plasma mass spectrometry or graphite furnace atomic absorption spectrometry. In all instances the agreement was satisfactory.  相似文献   

6.
Cadmium in polyethylene was determined by both inductively coupled plasma atomic emission spectrometry (ICP-AES) and atomic absorption spectrometry (AAS) with continuous-flow gas-phase sample introduction in a reaction medium of ascorbic acid. In the presence of mixture of cobalt and thiourea in the ascorbic acid solution, the sensitivities by both ICP-AES and AAS for cadmium were greatly enhanced. The gaseous cadmium species was phase-separated in a gas–liquid separator and directed via a stream of argon carrier gas to an inductively coupled plasma and an electrically heated quartz tube atomizer (QTA) for atomic spectrometry. Under the optimized experimental conditions, the best attainable detection limits at Cd I 228.802 nm line were 1.3 and 0.017 ng/ml with linear dynamic ranges of 10–500 ng/ml and 0.1–1 ng/ml in concentrations by ICP-AES and QTA-AAS, respectively. The instrumental precisions expressed as the relative standard deviation (R.S.D.) from ten replicate measurements of 50 and 1 ng/ml cadmium by ICP-AES and QTA-AAS were 5.6% and 3.2%, respectively. With the use of ICP-AES and QTA-AAS with gas-phase sample introduction method, six- and 200-fold improvements in detection limits for cadmium were obtained in comparison with their conventional solution nebulization methods, respectively. After the effects of several diverse elements on the determination of cadmium by ICP-AES and QTA-AAS with the present gas-phase sample introduction systems were examined, these methods were applied to the determination of low concentrations of cadmium in polyethylene. The results obtained by the present method were in good agreement with the certified values.  相似文献   

7.
High-performance liquid chromatography (HPLC) and thermospray mass spectrometry were combined for the analysis of DNA adducts formed from the interaction of the anticancer drugs mitomycin C, porfiromycin and thiotepa with calf thymus DNA. The adducts formed from reaction of mitomycin C and porfiromycin with DNA were separated from unmodified nucleosides by HPLC on a C18 column and identified by thermospray mass spectrometry. Thiotepa DNA adducts readily depurinated from DNA and were chromatographed and identified by thermospray liquid chromatography-mass spectrometry as the modified bases without the ribose moiety attached. The utility of thermospray mass spectrometry for the identification of microgram quantities of nucleoside adducts and depurinated base adducts of these anticancer drugs was demonstrated.  相似文献   

8.
A thermospray nebulizer was used as a sample introduction device for microwave plasma torch (MPT) atomic emission spectrometry (AES). Experimental parameters, including the power supplied to the MPT, the flow rates of support and carrier gases, the observation height, the sample uptake rate, the thermospray working temperature, the temperature of the aerosol spray chamber and cooling water were optimized. Under optimum conditions, the relative standard deviation (RSD) of 10 measurements for 21 elements is in the range 0.3–2.0%. The detection limits were improved in comparison with the ultrasonic nebulizer as sample introduction technique for MPT–AES. The inclusion of 20% methanol into the MPT showed there is no effect on the stability of MPT discharge. The technique can thus be held to have the potential for interface to reverse-phase HPLC systems.  相似文献   

9.
Summary A rapid method based on liquid chromatography and thermospray mass spectrometry without any derivatization or pre-purification steps has been developed for the identification and quantification of cannabinoids in drugs from cannabis plants. The extracts were separated on a C18 reversed-phase column with an acidic acetonitrile-water gradient. Liquid chromatographymass spectrometry was performed with a thermospray interface and protonated molecular ions were obtained from the cannabinoids of interest. Liquid chromatography-tandem mass spectrometry experiments on the molecular ions gave additional structural information online. The sensitivity and selectivity of the method was sufficient to enable the detection of 100 pg of the cannabinoids.  相似文献   

10.
The use of a photodiode array as a multichannel detector for off-line continuum correction in inductively coupled plasma-atomic emission spectrometry(ICP-AES)is demonstrated. The photodiode array allows concurrent data acquisition of all reference wavelengths necessary for the calculation of the background. An existing background correction algorithm that selects reference channels by a statistical criterion is modified for use with the photodiode array. The influence of several parameters on the performance of the algorithm is investigated with spectra derived from the photodiode array and from a conventional photomultiplier based system. It is shown that with either system background correction can be performed completely automated and sample adapted.  相似文献   

11.
A high-performance liquid chromatographic method was developed for thermospray mass spectrometric analysis of steroidal hormones. Using a Nova-Pak C18 reversed-phase column and isocratic elution with a solvent comprised of 25 mM ammonium formate in 30% acetonitrile, corticosteroids were separated within 10 min. This solvent also permitted ultraviolet absorbance detection down to 220 nm with low-nanogram sensitivity. The use of acetonitrile was favourable for thermospray mass spectrometric analysis because mass spectra were obtained with a pseudomolecular ion as the base peak. A combination of liquid chromatography, ultraviolet absorbance detection and thermospray mass spectrometry provided a sensitive and reliable method for unequivocal confirmation of the presence of steroidal drugs in equine urine.  相似文献   

12.
Argon-stabilized U-shaped DC arc with a system for aerosol introduction was used for the determination of As, Fe, Hg, Mn, and Pb. By applying a computer program performing a time integration of the registered signals and by optimizing the working conditions of an U-shaped arc plasma, the detection capability for As, Fe, Hg, Mn, and Pb was improved, which contributed to the lowering of the detection limits. The lowest detection limits for Fe, Mn, and Pb were achieved during an integration time of 20 s, and for As and Hg during an integration time of 30 s, and their values were 1.1, 0.1, 0.9, 15, and 2.6 ng/mL, respectively. The detection limits obtained by our method with optimal integration times were compared with the detection limits obtained using other methods: inductively coupled plasma-atomic emission spectrometry (ICP-AES), directly coupled plasma-atomic emission spectrometry (DCP-AES), microwave-induced plasma-atomic emission spectrometry (MIP-AES), inductively coupled plasma-mass spectrometry (ICP-MS), and an improved thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS). The text was submitted by the authors in English.  相似文献   

13.
Mierzwa J  Sun YC  Chung YT  Yang MH 《Talanta》1998,47(5):35-1270
The comparative determination of barium, copper, iron, lead and zinc in tea leaf samples by two atomic spectrometric techniques is reported. At first, slurry sampling electrothermal atomization atomic absorption spectrometry (ETAAS) was applied. The results of Ba and Pb determination were calculated using the method of standard additions, and results of Cu, Fe and Zn from the calibration graphs based on aqueous standards. These results were compared with the results obtained after microwave-assisted wet (nitric+hydrochloric+hydrofluoric acids) digestion in closed vessels followed by inductively coupled plasma-atomic emission spectrometric (ICP-AES) determination with the calibration by means of aqueous standards. The exception was lead determined after a wet digestion procedure by ETAAS. The accuracy of the studied methods was checked by the use of the certified reference material Tea GBW-07605. The recoveries of the analytes varied in the range from 91 to 99% for slurry sampling ETAAS, and from 92.5 to 102% for liquid sampling ICP-AES. The advantages of slurry sampling ETAAS method are simplicity of sample preparation and very good sensitivity. Slurry sampling ETAAS method is relatively fast but if several elements must be determined in one sample, the time of the whole microwave-assisted digestion procedure and ICP-AES determination will be shorter. However, worse detection limits of ICP-AES must also be taken into the consideration in a case of some analytes.  相似文献   

14.
The positive-ion mass spectra of a number of didehydro amino acids, ionized by electron impact and/or thermospray, and collision-induced dissociation spectra taken at collision energies of a few electron volts and keV have been performed on multiple quadrupole and reversed geometry sector instruments. Observed differences in the mass spectra and in the fragmentation patterns are explained in terms of different isomeric structures, different internal excitation energies and different ion transit times between the ion source and the collision cell. Molecular ions of unhydrated amino acids are efficiently formed both by electron impact and thermospray, whilst molecular ions of the hydrated compounds are formed more efficiently by the latter technique. The present investigation demonstrates that the use of different ionization techniques combined with mass spectrometry/mass spectrometry measurements at different collision energies yields a wealth of information relevant to structural characterization of this important class of molecules.  相似文献   

15.
A recently described thermospray flame furnace atomic absorption spectrometric (TS-FF-AAS) system has been modified in order to extend the applicability of the method for the determination of elemental traces in very small sample volumes (microliter or submicroliter). As an easily available, effective thermospray vaporizer, a fused silica capillary was used and the liquid sample was transported by 1 MPa (10 bar) gas pressure delivered by a standard gas cylinder. A 0.3 microL sample volume can be analyzed with a higher power of detection than using 3 orders of magnitude larger sample volumes with conventional flame atomic absorption spectrometry. The relative standard deviations (N=12) for 0.3 microL volumes and 5 microg/mL Pb samples amount to 3.1% and 3.8% in signal height and signal area, respectively. The detection limit was found to be 69 ng/mL. Initial experiments with other elements (Cd, Hg, Tl, Zn) led to similar results.  相似文献   

16.
热雾化法自问世以来 [1 ,2 ] ,就以其较高的雾化效率及传输效率受到学者们的普遍重视 .最近 Bordera等[3] 提出了一种新的热雾化系统 (该系统采用聚焦微波炉作热雾化系统中液体样品的热源 ,即微波热雾化系统 ,简称 MWTN) ,同时还考察了实验变量对雾滴粒径分布的影响 ,并预期 MWTN具有较高的雾化效率 .本文所提出的热雾化系统与 Bordera等所建立的 MWTN系统在原理上虽然相同 ,但由于采用了新的微波器件 ,所需功率大大降低 ,因此 ,是一种新的低功率 MWTN系统 .在本实验中 ,我们对酸的浓度、载气流量、样品提升量等参数对 Mg的发射强度…  相似文献   

17.
Elemental wine analysis is often required from a nutritional, toxicological, origin and authenticity point of view. Inductively coupled plasma based techniques are usually employed for this analysis because of their multi-elemental capabilities and good limits of detection. However, the accurate analysis of wine samples strongly depends on their matrix composition (i.e. salts, ethanol, organic acids) since they lead to both spectral and non-spectral interferences. To mitigate ethanol (up to 10% w/w) related matrix effects in inductively coupled plasma atomic emission spectrometry (ICP-AES), a microwave-based desolvation system (MWDS) can be successfully employed. This finding suggests that the MWDS could be employed for elemental wine analysis. The goal of this work is to evaluate the applicability of the MWDS for elemental wine analysis in ICP-AES and inductively coupled plasma mass spectrometry (ICP-MS). For the sake of comparison a conventional sample introduction system (i.e. pneumatic nebulizer attached to a spray chamber) was employed. Matrix effects, precision, accuracy and analysis throughput have been selected as comparison criteria. For ICP-AES measurements, wine samples can be directly analyzed without any sample treatment (i.e. sample dilution or digestion) using pure aqueous standards although internal standardization (IS) (i.e. Sc) is required. The behaviour of the MWDS operating with organic solutions in ICP-MS has been characterized for the first time. In this technique the MWDS has shown its efficiency to mitigate ethanol related matrix effects up to concentrations of 1% (w/w). Therefore, wine samples must be diluted to reduce the ethanol concentration up to this value. The results obtained have shown that the MWDS is a powerful device for the elemental analysis of wine samples in both ICP-AES and ICP-MS. In general, the MWDS has some attractive advantages for elemental wine analysis when compared to a conventional sample introduction system such as: (i) higher detection capabilities; (ii) lower ethanol matrix effects; and (iii) lower spectral interferences (i.e. ArC(+)) in ICP-MS.  相似文献   

18.
一种可用于微波等离子体炬原子发射光谱法的热雾化系统   总被引:1,自引:0,他引:1  
建立了一种新的热雾化系统,用蠕动泵代替高压泵,去掉了加热管部分,使整个热雾化系统更加紧凑,经济,并将其用于微波等离子体炬(MPT)-原子发射光谱法(AES),考察了实验参数的影响,与气动雾化相比,对Mg,Pb的检出限改善了5~10倍,同时发现本装置具有元素选择性增强的现象。  相似文献   

19.
A thermospray high-performance liquid chromatography-mass spectrometry method for analysis of hyoscyamine and scopolamine in plant cell culture samples is described. The alkaloids were separated on a polymeric reversed-phase column with an alkaline ammonium acetate buffer-acetonitrile eluent. Selected-ion recording of the protonated molecular ions was used for quantitation of the compounds. The compounds were fragmented by discharge-assisted ionization and elevated thermospray capillary temperatures or ion repeller potentials.  相似文献   

20.
Electrochemistry was used on-line with high-performance liquid chromatography-thermospray tandem mass spectrometry to provide insight into the solution-phase decomposition reactions of electrochemically generated oxidation products. Products formed during electrooxidation were monitored as the electrode potential was varied. The solution reactions which follow the initial electron transfer at the electrode are affected by the vaporizer tip temperature of the thermospray probe and the composition of the thermospray buffer. Either hydrolysis or ammonolysis reactions of the initial electrochemical oxidation products can occur with pH 7 ammonium acetate buffer. Both the electrochemically generated and the synthesized disulfide of 6-thiopurine decompose under thermospray conditions to produce 6-thiopurine and purine-6-sulfinate. Solution-phase studies indicate that nucleophilic and electrophilic substitution reactions with purine-6-sulfinate result in the formation of purine, adenine, and hypoxanthine. Products were identified and characterized by tandem mass spectrometry. This work shows the first example of high-performance liquid chromatography used on-line with electrochemistry to separate stable oxidation products prior to analysis by thermospray tandem mass spectrometry. In addition, solution-phase and gas-phase studies with methylamine show that the site of the nucleophilic and electrophilic reactions is probably inside the thermospray probe. Most importantly, these results also show that the on-line combination of electrochemistry with thermospray tandem mass spectrometry provides valuable information about redox and associated chemical reactions of biological molecules such as the structures of intermediates or products as well as providing insight into reaction pathways.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号