首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
Two-dimensional infrared (2D IR) spectroscopy is used to study atactic polystyrene. 2D IR is a technique based on time-resolved detection of IR signals in response to an external perturbation, such as mechanical strain. Since different chemical functional groups respond to the applied perturbation at unique and often different rates, characteristic time-dependent variations of the IR-band intensities are observed. Correlation analysis of the dynamic variation of the IR signals yields a new spectrum defined by two independent wave numbers. Peaks located on a 2D IR spectral plane imply interactions and connectivities among chemical functional groups. By spreading convoluted IR bands over two dimensions, the spectral resolution is also greatly enhanced.  相似文献   

2.
Crystallization of poly(trimethylene terephthalate) (PTT) by annealing was examined using density measurement, differential scanning calorimetry, and far‐infrared spectroscopy (FIR). Crystallinity, measured by density, increased slowly up to the Ta of 185 °C and increases rapidly once Ta exceeds 185 °C. It was found that thermally induced crystallization is mainly temperature‐dependent above Ta = 185 °C and temperature‐ and time‐dependent below Ta = 60 °C. Two melting transitions, T and T, were observed for those samples annealed above 120 °C. No significant change in T was observed as a function of Ta while T showed strong dependency on Ta. Digital subtraction of the amorphous contribution from the semicrystalline FIR spectra provided characteristic spectra of amorphous and crystalline PTT. The bands at 373, 282, and 92 cm?1 were assigned to the crystalline phase, while the bands at 525, 406, and 351 cm?1 were attributed to the amorphous phase. It was shown that FIR spectroscopy can be used as a means to estimate the degree of crystallinity of PTT. The band ratio of 373 and 501 cm?1 was plotted against crystallinity measured by density and reasonably good correlation was obtained. © 2007 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys 45: 1675–1682, 2007  相似文献   

3.
The use of a bench top FTIR spectrometer for near infrared Fourier transform Raman spectroscopy is demonstrated. The use of near infrared excitation results in fluorescence free Raman spectra allowing previously difficult samples to be measured.  相似文献   

4.
The need for effective bioprocess (fermentation) monitoring is growing in importance due to the rapid pace of change in the fermentation industry, and attendant financial pressures. Vibrational spectroscopy has shown great promise in bioprocess monitoring. In particular, recently attention has been focused on the capability of mid infrared spectroscopy (MIRS) to monitor multiple analytes in highly complex fermentation fluids. The potential of this powerful analytical technique is critically evaluated by discussion of relevant studies. The advantages and limitations of MIR are discussed in the context of “rival” technologies, such as near infrared, focusing especially on employing such techniques in bioprocesses for real time (either in situ or ex situ) measurements. The potential barriers to the development of MIRS for real time monitoring are identified and further research directions highlighted.  相似文献   

5.
Near infrared spectroscopy (NIR) was used to characterize the nature of specific interactions in blends of lightly sulfonated polystyrene ionomers (M‐SPS where M = Zn+2, Mn+2, or Li+) and polycaprolactam (PA6). The assignments of the NIR overtone bands that arise due to the interactions between the cation of the ionomer, and the amide groups were made using spectra of model compounds. The relative populations of the different environments of the N? H groups were qualitatively determined by deconvoluting the NIR spectra into five absorbances representing hydrogen‐bonded N? H in crystalline and amorphous phases and an ion‐amide complex. The ion‐amide complex was specific for the blends. The interpolymer interactions were sensitive to composition and temperature, but qualitatively the behavior was the same for all three ionomer salts investigated. © 2008 Wiley Periodicals, Inc. JPolym Sci Part B: Polym Phys 46: 1602–1610, 2008  相似文献   

6.
Near infrared spectroscopic and multivariate statistical control charts based on the net analyte signal (NAS) were applied to the polymorphic characterization of Piroxicam samples. Three different polymorphic forms (I, II and III) were studied, using X-ray powder diffraction (XRPD) and scanning electron microscopy as reference techniques. Samples containing form I were considered inside the quality specifications and forms II and III were impurities. Three control charts were developed: the NAS chart that corresponds to the analyte of interest (polymorphic form I), the interference chart that corresponds to the contribution of other compounds in the sample and the residual chart that corresponds to nonsystematic variation. From the limits estimated for each chart using samples inside the quality specifications, it was possible to identify samples that did not present polymorphic form I. The use of multivariate control charts provides a rapid evaluation of purity and the polymorphic composition of pharmaceutical formulations based on Piroxicam.  相似文献   

7.
8.
A new high‐sensitive photo‐radical initiator, N‐[2‐(2‐acryloyloxyethoxy)ethyl]‐1,8‐naphthalimide (NI6), with good thermal stability based on naphthylimide derivative was developed. NI6 was prepared by the condensation of N‐[2‐(2‐hydroxyethoxy)ethyl]‐1,8‐naphthalimide and acryloyl chloride in the presence of 4‐dimethylaminopyridine. The film consisting of NI6 and pentaerythritol triacrylate (PETA) showed higher photosensitivity than those containing conventional photo‐radical initiators such as acrylic acid 2‐(2‐{2‐[2‐(4‐benzoyl‐phenoxy)‐ethoxy]‐ethoxy}‐ethoxy)‐ethyl ester, cyclohexylmaleimide, and the resulting film exhibited very high transmittance over 400 nm. The thermal stability of NI6 was very high and no decomposed residues were observed from the film consisting of NI 6 after heating at 250 °C for 1 h. © 2005 Wiley Periodicals, Inc. J Polym Sci Part A: Polym Chem 43: 5571–5580, 2005  相似文献   

9.
This paper reports the results of a rapid method to determine sucrose in chocolate mass using near infrared spectroscopy (NIRS). We applied a broad-based calibration approach, which consists in putting together in one single calibration samples of various types of chocolate mass. This approach increases the concentration range for one or more compositional parameters, improves the model performance and requires just one calibration model for several recipes. The data were modelled using partial least squares (PLS) and multiple linear regression (MLR). The MLR models were developed using a variable selection based on the coefficient regression of PLS and genetic algorithm (GA). High correlation coefficients (0.998, 0.997, 0.998 for PLS, MLR and GA-MLR, respectively) and low prediction errors confirms the good predictability of the models. The results show that NIR can be used as rapid method to determine sucrose in chocolate mass in chocolate factories.  相似文献   

10.
Cytochrome P450 proteins (CYPs) are a big class of heme proteins which are involved in various metabolic processes of living organisms. CYPs are the terminal catalytically active components of monooxygenase systems where the substrate binds and is hydroxylated. In order to be functionally competent, the protein structures of CYPs possess specific properties that must be explored in order to understand structure–function relationships and mechanistic aspects. Fourier transform infrared spectroscopy (FTIR) is one tool that is used to study these structural properties. The application of FTIR spectroscopy to the secondary structures of CYP proteins, protein unfolding, protein–protein interactions and the structure and dynamics of the CYP heme pocket is reviewed. A comparison with other thiolate heme proteins (nitric oxide synthase and chloroperoxidase) is also included. Figure The protein secondary structure, protein unfolding, redox-partner protein–protein interaction, structural changes induced by the reduction of the heme iron, and the structure and dynamics of the active site of cytochromes P450 (CYP) can be studied using Fourier transform infrared spectroscopy (FTIR). FTIR spectroscopy is a good approach for gaining a deeper insight into structure–function relationships in CYPs. Electronic supplementary material  The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

11.
模式识别技术广泛应用于食品种类、品牌和原产地的分类鉴别.本文测定了三个品牌114个料酒样品的可见-近红外光谱,利用小波变换技术对光谱信号进行了去噪和压缩处理,并采用Fisher权重法计算了16个小波细节系数的Fisher权重.以16个小波细节系数为特征变量采用向量相似度法对三种不同品牌料酒进行了相似度分析,主成分分析法...  相似文献   

12.
Two vibrational spectrometry-based methodologies were developed for Metamitron determination in pesticide formulations. Fourier transform-middle infrared (FT-MIR) procedure was based on the extraction of Metamitron by CHCl3 and latter determination by peak area measurement between 1556 and 1533 cm−1, corrected with a two points baseline established from 1572 to 1514 cm−1. Fourier transform-near infrared (FT-NIR) determination was made after the extraction of Metamitron in acetonitrile and measuring the peak area between 6434 and 6394 cm−1 corrected using a two points baseline defined between 6555 and 6228 cm−1. Repeatability, as relative standard deviation, of 5 independent measurements at mg g−1 concentration level, of 0.16% and 0.07% for MIR and NIR and a limit of detection of 0.03 and 0.004 mg g−1 were obtained for MIR and NIR, respectively.NIR determination provides a sample frequency of 120 h−1, higher than that found by MIR and liquid chromatographic methods (60 and 15 h−1, respectively). On the other hand, the NIR method reduces the solvent consumption and waste generation, to only 1 ml acetonitrile per sample as compared with 3.4 ml chloroform required for the MIR determination and 60 ml acetonitrile used in the chromatographic reference procedure. So, vibrational procedures can be considered serious alternatives to long and time consuming chromatographic methods usually recommended for quality control of commercially available pesticide formulations.  相似文献   

13.
The application of near infrared spectroscopy in bioprocessing has been limited by its dependence on calibrations derived from single bioreactor at a given time. Here, we propose a multiplexed calibration technique which allows calibrations to be built from multiple bioreactors run in parallel. This gives the flexibility to monitor multiple vessels and facilitates calibration model transfer between bioreactors. Models have been developed for the two key analytes: glucose and lactate using Chinese hamster ovary (CHO) cell lines and using analyte specific information obtained from the feasibility studies. We observe slight model degradation for the multiplexed models in comparison to the conventional (single probe) models, decrease in r2 values from 89.4% to 88% for glucose whereas for lactate from 92% to 91.8% and a simultaneous increase in the number of factors as the model incorporates the inter-probe variability, nevertheless the models were fit for purpose. The results of this particular application of implementing multiplexed-NIRS to monitor multiple bioreactor vessels are very encouraging, as successful models have been built on-line and validated externally, which proffers the prospect of reducing timelines in monitoring the vessels considerably, and in turn, providing improved control.  相似文献   

14.
Simultaneous dielectric and near infrared measurements have been performed in “real-time” to follow polymerisation reactions on blends of a diglycidyl ether of bisphenol-A epoxy resin with 4,4-diaminodiphenylmethane hardener and different amounts of poly(methylmethacrylate) as modifier. The effect of the modifier amount on the polymerisation reactions has been studied, as well as that of the curing temperature. Epoxy and amine conversions have been followed by near infrared spectroscopy (NIR), while changes in molecular mobility in the reaction mixture have been analysed by dielectric relaxation spectroscopy (DRS). Evolutions of ionic conductivity and α-relaxation have been analysed and vitrification times have been obtained. The relaxational behaviour has been analysed through curing in the frequency domain, being the change of the main relaxation indicative of the cure reaction advancement. DRS data are also presented as complex impedance Z(ω). Vitrification times, obtained by dielectrometry have been compared with those obtained by rheological measurements and gelation times obtained by NIR have been compared with those obtained by solvent extraction.  相似文献   

15.
 Fourier transform infrared spectra in the wave number range 450–4500 cm-1 of poly (2-hydroxy-ethyl methacrylate) PHEMA have been studied as functions of water content in the range 38–2.6 wt% and of temperature in the range 300–373 K. The results show changes in the intensities of the stretching frequencies of the carbonyl band, H–O–H bending vibration and O–H stretching vibration with a change in water content and temperature. The results confirm two types of water in the hydrogel polymer system, tightly bound water and loosely bound water. At low concentrations, water is mainly hydrogen-bonded to the polymer and is described as tightly bound water. However, at water concentrations greater than 18% by weight, part of the water exists in a different form and behaves as loosely bound water. For concentrations over 30%, there is some evidence that excess water behaves more loosely bound somewhat like bulk water. Infrared spectroscopic results supplement those obtained by means of NMR by Smyth et al. and by dielectric spectroscopy. Our results also show that some of the water continues to be hydrogen bonded to the polymer until at least a temperature of 373 K when the bulk water should have evaporated. FTIR is found to yield greater site-specific insight into the local behaviour of water in hydrated PHEMA. Received: 22 August 1996 Accepted: 11 November 1996  相似文献   

16.
A quick and reliable analytical method for the quantitative assessment of roxithromycin in pharmaceutical formulations was developed using Fourier-transform infrared (FT-IR) transmission spectroscopy for routine quality control. The sample preparation was avoided except grinding for pellet formation and eliminated the use of toxic solvents. For the determination of roxithromycin, conventional KBr was used in the form of pellets for acquisition of the FT-IR spectra of standards and samples. The calibration model was developed based on simple Beer's law using the FT-IR carbonyl region (CO) from 1765 to 1705 cm−1. The excellent coefficient of determination (R2) was achieved (0.9992) with 0.01 mg standard error of calibration. This work clearly revealed the capability of the transmission FT-IR spectroscopy and extended its application for determining the exact quantity of roxithromycin to control the processing formulation and quality of finished product with the analysis time of less than 3 min using the neat solid samples.  相似文献   

17.
An improved time-resolved step-scan Fourier transform rheo-optical system, based on the soft-pulse dynamic compression attenuated total reflection (ATR) approach, has been introduced to analyze inter-molecular interactions of poly(p-phenylene bi-phenyltetracarboximide) (BPDA–PDA) and poly(N,N-diphenyl ether bi-phenyltetracarboximide) (BPDA–ODA) films. In order to extract the full range of frequency distributions obtained from soft-pulse dynamic compression time response (relaxation) spectra, the second-Fourier transformation was applied along the relaxation time axis in addition to the interferogram axis. In the case of the BPDA–PDA, distinct periodic higher overtone bands are observed especially at C=O stretching and C=C tangential stretching vibration bands in the FFT relaxation time contour map spectra. For the BPDA–ODA, intensities of higher overtone bands are relatively weak. We have further performed 2D-IR correlation analysis at given Fourier frequencies, which includes molecular interaction information. The results suggest that the existence of molecular interaction between C=O stretching and C=C tangential stretching vibration bands.  相似文献   

18.
The morphological characterization of polymer blends consisting of polyamide and poly(tetrafluoroethylene) using FT-IR spectroscopy and electron microscopy is described. To enhance the lateral resolution - one of the main limits in infrared spectroscopy - a combination with scanning electron microscopy and analytical electron microscopic methods of a transmission electron microscope was made. The possibilities of electron energy loss spectroscopy and energy filtered transmission electron microscopy (EFTEM) in the area of polymer characterization are outlined.  相似文献   

19.
The band-target entropy minimization (BTEM) curve resolution technique has been used to analyze in situ reflection-absorption infrared spectroscopy (RAIRS) data of CO chemisorption on Ni(1 1 1) single crystal surfaces. The bilinearity assumption for pRAIRS data, that is, negative logarithm to the base 10 of raw reflectance RAIRS data, was found to be sufficiently valid for the test data. A total of 11 real pure component pRAIRS spectra were elucidated via BTEM in tandem with an iterative residual spectral data analysis. Furthermore, 2 abstract pure component right singular vectors were found to account for all the pRAIRS non-linearities, baseline drifts and other spectral noise. In total, 100.2% of the pRAIRS signals were accounted for by these 13 spectral components. The 11 real pure component pRAIRS spectra and their corresponding relative concentration kinetic sequences correlate with 6 well-known adsorbed CO domain structures. Moreover, amongst the BTEM resolved spectra were five new bands that were not previously observed using conventional visual identification methods adopted by surface chemists. These new bands engendered new understanding to the mechanism of CO chemisorption on Ni(1 1 1). The combination of BTEM with residual spectral analysis was thus demonstrated to be efficacious for curve resolution of in situ RAIRS data obtained from surface chemistry studies.  相似文献   

20.
In the pharmaceutical industry, dextrose is used as an active ingredient in parenteral solutions and as an inactive ingredient (excipient) in tablets and capsules. In order to address the need for more sophisticated analytical techniques, we report our efforts to develop enhanced identification methods to screen pharmaceutical ingredients at risk for adulteration or substitution using field-deployable spectroscopic screening. In this paper, we report our results for a study designed to evaluate the performance of field-deployable Raman and near infrared (NIR) methods to identify dextrose samples. We report a comparison of the sensitivity of the spectroscopic screening methods against current compendial identification tests that rely largely on a colorimetric assay. Our findings indicate that NIR and Raman spectroscopy are both able to distinguish dextrose by hydration state and from other sugar substitutes with 100% accuracy for all methods tested including spectral correlation based library methods, principal component analysis and classification methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号