首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Human serum immunoglobulin M (IgM) or human immunoglobulin G (IgG) were adsorbed to dichlorodimethyl silane (DDS) treated silicon. Subsequently, the model surfaces were incubated in normal-, complement factor 1q (C1q)-complement factor B or complement factor 2 (C2)-depleted human sera at 37 degrees C for up to 1.5 h. The serum deposition and binding of selected polyclonal complement antibodies into this layer were then quantified by null ellipsometry. Both types of precoated surfaces bound large amounts of anti-complement factor 3c (anti-C3c), anti-properdin and anti-C3d, after incubation in normal serum. In contrast to IgG coated surfaces, IgM coated surfaces bound no anti-C1q after the serum incubations and no anti-C3c deposition lag time was observed after incubations in EGTA serum. Upon immersions of IgM coated surfaces in the different sera, a rapid complement activation via a C1q factor B, and Ca(2+)-independent, but C2 dependent pathway, was indicated. When IgM was instead immobilized to APTES/glutaraldehyde surfaces, anti-C3c deposition was lower after incubations in EGTA than normal serum. The results suggest that, under the present experimental conditions, human IgM and IgG activate the complement system differently.  相似文献   

2.
Adsorption of anionic polyelectrolytes, sodium salts of carboxymethyl celluloses (CMCs) with different degrees of substitution (DS = 0.9 and 1.2), from aqueous electrolyte solutions onto regenerated cellulose surfaces was studied using quartz crystal microbalance with dissipation monitoring (QCM-D) and surface plasmon resonance (SPR) experiments. The influence of both calcium chloride (CaCl(2)) and sodium chloride (NaCl) on CMC adsorption was examined. The QCM-D results demonstrated that CaCl(2) (divalent cation) caused significantly greater CMC adsorption onto regenerated cellulose surfaces than NaCl (monovalent cation) at the same ionic strength. The CMC layers adsorbed onto regenerated cellulose surfaces from CaCl(2) solutions exhibited greater stability upon exposure to flowing water than layers adsorbed from NaCl solutions. Both QCM-D and SPR results showed that CMC adsorption onto regenerated cellulose surfaces from CaCl(2) solutions increased with increasing CaCl(2) concentration up to the solubility limit (10 mM). Voigt-based viscoelastic modeling of the QCM-D data indicated that the CMC layers adsorbed onto regenerated cellulose surfaces had shear viscosities of η(f) ≈ 10(-3) N·s·m(-2) and elastic shear moduli of μ(f) ≈ 10(5) N·m(-2). Furthermore, the combination of SPR spectroscopy and QCM-D showed that the CMC layers contained 90-95% water. Adsorption isotherms for CMCs in CaCl(2) solutions were also obtained from QCM-D and were fit by Freundlich isotherms. This study demonstrated that CMC adsorption from CaCl(2) solutions is useful for the modification of cellulose surfaces.  相似文献   

3.
Quartz crystal microbalance with dissipation (QCM-D) measurements were used to investigate the adsorption of human fibrinogen, human serum albumin, bovine hemoglobin, horse heart cytochrome c, human immunoglobulin (hIgG), and 10% fetal bovine serum on supported bilayers of egg-phosphatidylcholine (eggPC) lipids. For comparison the adsorption of fibrinogen and hIgG to eggPC bilayers was also studied with surface plasmon resonance (SPR). The supported bilayers were formed in situ by vesicle adhesion and spontaneous fusion onto a SiO(2) surface. The supported lipid bilayer is highly protein resistant: The irreversible adsorption measured with the QCM-D technique was below the detection level, while reversible protein adsorption was detected for all the proteins in the range 0.3-4% of the saturation coverage on a hydrophobic thiol monolayer on gold. The adsorbed amounts were slightly higher for the SPR measurements. Possible mechanisms for the protein resistance of eggPC bilayers are briefly discussed.  相似文献   

4.
The adsorption of proteins at material surfaces is important in applications such as biomaterials, drug delivery, and diagnostics. The interaction of cells with artificial surfaces is mediated through adsorbed proteins, where the type of protein, amount, orientation, and conformation are of consequence for the cell response. Laminin, an important cell adhesive protein that is central in developmental biology, is studied by a combination of quartz crystal microbalance with dissipation (QCM-D) and surface plasmon resonance (SPR) to characterize the adsorption of laminin on surfaces of different surface chemistries. The combination of these two techniques allows for the determination of the thickness and effective density of the protein layer as well as the adsorbed mass and viscoelastic properties. We also evaluate the capacity of QCM-D to be used as a quantitative technique on a nanostructured surface, where protein is adsorbed specifically in a nanopattern exploiting PLL-g-PEG as a protein-resistant background. We show that laminin forms a highly hydrated protein layer with different characteristics depending on the underlying substrate. Using a combination of QCM-D and atomic force microscopy (AFM) data from nanostructured surfaces, we model laminin and antibody binding to nanometer-scale patches. A higher amount of laminin was found to adsorb in a thicker layer of a lower effective density in nanopatches compared to equivalent homogeneous surfaces. These results suggest that modeling of QCM-D data of soft viscoelastic layers arranged in nanopatterns may be applied where an independent measure of the "dry" mass is known.  相似文献   

5.
Nanostructured materials strongly modulate the behavior of adsorbed proteins; however, the characterization of such interactions is challenging. Here we present a novel method combining protein adsorption studies at nanostructured quartz crystal microbalance sensor surfaces (QCM-D) with optical (surface plasmon resonance SPR) and electrochemical methods (cyclic voltammetry CV) allowing quantification of both bound protein amount and activity. The redox enzyme glucose oxidase is studied as a model system to explore alterations in protein functional behavior caused by adsorption onto flat and nanostructured surfaces. This enzyme and such materials interactions are relevant for biosensor applications. Novel nanostructured gold electrode surfaces with controlled curvature were fabricated using colloidal lithography and glancing angle deposition (GLAD). The adsorption of enzyme to nanostructured interfaces was found to be significantly larger compared to flat interfaces even after normalization for the increased surface area, and no substantial desorption was observed within 24 h. A decreased enzymatic activity was observed over the same period of time, which indicates a slow conformational change of the adsorbed enzyme induced by the materials interface. Additionally, we make use of inherent localized surface plasmon resonances in these nanostructured materials to directly quantify the protein binding. We hereby demonstrate a QCM-D-based methodology to quantify protein binding at complex nanostructured materials. Our approach allows label free quantification of protein binding at nanostructured interfaces.  相似文献   

6.
Surface mediated immune complement activation can be detected by a variety of antibody utilizing methods such as ELISA, fluorescence- or radiolabelling techniques, QCM, and ellipsometry. In the present work we investigated how the common anticoagulants heparin, dalteparin, fondaparinux and sodium citrate affected the binding of anti-complement factor 3c (anti-C3c) on a model complement activator surface, immobilised IgG, after incubation in human blood serum.

The results show, as expected, that different anticoagulants affect the antibody binding differently. Increasing amounts of heparin, dalteparin and sodium citrate in normal serum resulted in a decreasing anti-C3c binding. The antibody deposition was not sensitive for the fondaparinux concentration. Surprisingly high concentrations of anti-coagulantia were needed to completely eradicate the antibody binding. Experiments in EGTA–serum showed that anticoagulants interfered directly with both the classical and alternative pathways. Control C3a-des arg ELISA measurements show that the lowered antibody surface binding was not a result of complement depletion in serum. Kallikrein generation by hydrophilic glass surfaces was not affected by high anticoagulant concentrations.  相似文献   


7.
We have studied the activation kinetics of zinc sulfide (ZnS) using silver as an activator by a quartz crystal microbalance with dissipation (QCM-D). The zinc sulfide coating on QCM-D sensor was shown to have similar crystallographic structure, composition, and surface properties as nature sphalerite through the characterization of X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), and xanthate adsorption measurement using QCM-D. The activation of ZnS sensor by silver was confirmed by the mass increase in ZnS sensor coupled with subsequent xanthate adsorption during QCM-D measurement, the change of surface wettability, and the presence of Ag(2)S on the surface. Two distinct stages on the silver uptake vs. time curve were identified and fitted well by a logarithmic function for the initial stage and a parabolic law in the later stage, which agrees with the two-stage zinc-silver reaction kinetics reported previously. Argon sputtering followed by XPS measurement on the ZnS surface demonstrated the penetration of silver into the bulk ZnS after activation. The present study is the first of its kind to apply the QCM-D technique to investigate sphalerite activation, which introduces a new in situ approach to investigate surface adsorption and activation in many mineral processes and surface modifications.  相似文献   

8.
The scope of this study is to modify a Surface Plasmon Resonance (SPR) sensor slide with isophthalic acid to evaluate the possible application on the detection of copper(II) ions in aqueous media by total internal reflection ellipsometry. A gold sensor surface was modified by an electrochemical diazonium reduction modification method. The modified surfaces are characterized with cyclic voltammetry (CV) and ellipsometry. Isophthalic acid monolayer modified gold slides were used for in situ detection of aqueous Cu(2+) solution with the SPR enhanced total internal reflection ellipsometry (SPRe-TIRE) technique. Layer formation, pH dependency of adsorption, sensor response of the SPRe-TIRE and isothermal kinetic parameters were examined. A high dependency on the number of CV cycles in the monolayer-multiple layer transition was observed. The suggested sensor gave a linear response over a wide range of Cu(2+) concentrations. It was also reported that adsorption on the SPRe-TIRE sensor gave Langmuir adsorption model behavior.  相似文献   

9.
The adsorption behavior of ethyl(hydroxyethyl) cellulose EHEC and hydrophobically modified EHEC (HM-EHEC) at hydrophilic and hydrophobic surfaces has been studied using surface plasmon resonance (SPR) and quartz crystal microbalance with dissipation monitoring (QCM-D) methods. The adsorbed amounts measured with the different methods were different due to large amounts of water in the films. The slow adsorption process made it reasonable to assume a continuous polymer reconfiguration process at the surface. This was mostly seen for HM-EHEC at the hydrophobic surface, where a more flexible structure was adopted during the adsorption process. A cross-linking agent was seen to truly interpolymer cross-link EHEC at the hydrophilic surface and HM-EHEC at the hydrophobic surface. For EHEC at a hydrophobic surface and for HM-EHEC at a hydrophilic surface, the polymers adsorbed in an individually phase-separated manner, making an interpolymer cross-linking reaction unsuccessful.  相似文献   

10.
Time-resolved adsorption behavior of a human immunoglobin G (hIgG) protein on a hydrophobized gold surface is investigated using multitechniques: quartz crystal microbalance/dissipation (QCM-D) technique; combined surface plasmon resonance (SPR) and Love mode surface acoustic wave (SAW) technique; combined QCM-D and atomic force microscopy (AFM) technique. The adsorbed hIgG forms interfacial structures varying in organization from a submonolayer to a multilayer. An "end-on" IgG orientation in the monolayer film, associated with the surface coverage results, does not corroborate with the effective protein thickness determined from SPR/SAW measurements. This inconsistence is interpreted by a deformation effect induced by conformation change. This conformation change is confirmed by QCM-D measurement. Combined SPR/SAW measurements suggest that the adsorbed protein barely contains water after extended contact with the hydrophobic surface. This limited interfacial hydration also contributed to a continuous conformation change in the adsorbed protein layer. The viscoelastic variation associated with interfacial conformation changes induces about 1.5 times overestimation of the mass uptake in the QCM-D measurements. The merit of combined multitechnique measurements is demonstrated.  相似文献   

11.
一种新的压电免疫传感器中生物分子固定化方法的研究   总被引:11,自引:0,他引:11  
生物分子固定化或传感界面设计技术是研制压电免疫传感器的关键之一。本文 结合自组装单分子膜(SAMs)和聚电解质静电吸附组装技术,提出了一种新的压电 免疫传感器中生物分子固定化方法,研制成一种检测补体C_3的压电免疫传感器。 先在石英晶振的金电极表面组装一层胱胺SAMs,再在膜上组装带相反电荷的聚苯磺 酸钠(PSS)单层膜,通过静电吸附作用固定抗体(抗原),实现对相应抗原(抗 体)的检测。利用扫描电镜技术,从形态上考察了晶振组装胱氨SAMs与PSS及固定 补体C_3抗体后的表面形貌。研究了抗体的固定化条件,探讨了传感器采用这种固 定化方法的响应与再生性能,并与戊二醛键合固定法进行比较。结果表明,这种固 定化方法不仅对蛋白质类生物分子的固定化具有普适性,而且对所固定的生物分子 的活性影响小,传感器的响应的频移值大,灵敏度高,选择性和再生性能均较好。  相似文献   

12.
Monolayers of metal complexes were covalently attached to the surface of lamellar SPR interfaces (Ti/Ag/a-Si(0.63)C(0.37)) for binding histidine-tagged peptides with a controlled molecular orientation. The method is based on the activation of surface acid groups with N-hydroxysuccinimide (NHS), followed by an amidation reaction with (S)-N-(5-amino-1-carboxypentyl)iminodiacetic acid (NTA). FTIR and X-ray photoelectron spectroscopy (XPS) were used to characterize each surface modification step. The NTA modified SPR interface effectively chelated Cu(2+) ions. Once loaded with metal ions, the modified SPR interface was able to bind specifically to histidine-tagged peptides. The binding process was followed by surface plasmon resonance (SPR) in a droplet based configuration. The Cu(2+)-NTA modified interface showed protein loading comparable to commercially available NTA chips based on dextran chemistry and can thus be regarded as an interesting alternative. The sensor interface can be reused several times due to the easy regeneration step using ethylenediaminetetraacetic acid (EDTA) treatment.  相似文献   

13.
Removing adsorbed protein from metals has significant health and industrial consequences. There are numerous protein-adsorption studies using model self-assembled monolayers or polymeric substrates but hardly any high-resolution measurements of adsorption and removal of proteins on industrially relevant transition metals. Surgeons and ship owners desire clean metal surfaces to reduce transmission of disease via surgical instruments and minimize surface fouling (to reduce friction and corrosion), respectively. A major finding of this work is that, besides hydrophobic interaction adhesion energy, water content in an adsorbed protein layer and secondary structure of proteins determined the access and hence ability to remove adsorbed proteins from metal surfaces with a strong alkaline-surfactant solution (NaOH and 5 mg/mL SDS in PBS at pH 11). This is demonstrated with three blood proteins (bovine serum albumin, immunoglobulin, and fibrinogen) and four transition metal substrates and stainless steel (platinum (Pt), gold (Au), tungsten (W), titanium (Ti), and 316 grade stainless steel (SS)). All the metallic substrates were checked for chemical contaminations like carbon and sulfur and were characterized using X-ray photoelectron spectroscopy (XPS). While Pt and Au surfaces were oxide-free (fairly inert elements), W, Ti, and SS substrates were associated with native oxide. Difference measurements between a quartz crystal microbalance with dissipation (QCM-D) and surface plasmon resonance spectroscopy (SPR) provided a measure of the water content in the protein-adsorbed layers. Hydrophobic adhesion forces, obtained with atomic force microscopy, between the proteins and the metals correlated with the amount of the adsorbed protein-water complex. Thus, the amount of protein adsorbed decreased with Pt, Au, W, Ti and SS, in this order. Neither sessile contact angle nor surface roughness of the metal substrates was useful as predictors here. All three globular proteins behaved similarly on addition of the alkaline-surfactant cleaning solution, in that platinum and gold exhibited an increase, while tungsten, titanium, and stainless steel showed a decrease in weight. According to dissipation measurements with the QCM-D, the adsorbed layer for platinum and gold was rigid, while that for the tungsten, titanium, and stainless steel was much more flexible. The removal efficiency of adsorbed-protein by alkaline solution of SDS depended on the water content of the adsorbed layers for W, Ti, and SS, while for Pt and Au, it depended on secondary structural content. When protein adsorption was high (Pt, Au), protein-protein interactions and protein-surface interactions were dominant and the removal of protein layers was limited. Water content of the adsorbed protein layer was the determining factor for how efficiently the layer was removed by alkaline SDS when protein adsorption was low. Hence, protein-protein and protein-surface interactions were minimal and protein structure was less perturbed in comparison with those for high protein adsorption. Secondary structural content determined the efficient removal of adsorbed protein for high adsorbed amount.  相似文献   

14.
The immobilisation of biological recognition elements onto a sensor chip surface is a crucial step for the construction of biosensors. While some of the optical biosensors utilise silicon dioxide as the sensor surface, most of the biosensor surfaces are coated with metals for transduction of the signal. Biological recognition elements such as proteins can be adsorbed spontaneously on metal or silicon dioxide substrates but this may denature the molecule and can result in either activity reduction or loss. Self assembled monolayers (SAMs) provide an effective method to protect the biological recognition elements from the sensor surface, thereby providing ligand immobilisation that enables the repeated binding and regeneration cycles to be performed without losing the immobilised ligand, as well as additionally helping to minimise non-specific adsorption. Therefore, in this study different surface chemistries were constructed on SPR sensor chips to investigate protein and DNA immobilisation on Au surfaces. A cysteamine surface and 1%, 10% and 100% mercaptoundecanoic acid (MUDA) coatings with or without dendrimer modification were utilised to construct the various sensor surfaces used in this investigation. A higher response was obtained for NeutrAvidin immobilisation on dendrimer modified surfaces compared to MUDA and cysteamine layers, however, protein or DNA capture responses on the immobilised NeutrAvidin did not show a similar higher response when dendrimer modified surfaces were used.  相似文献   

15.
One of the sulfobetaine methacrylate (SBMA) monomers, N-(3-sulfopropyl)-N-(methacryloxyethyl)-N,N-dimethylammonium betaine, was polymerized onto initiator-covered gold surfaces using atom transfer radical polymerization (ATRP) to form uniform polymer brushes. Self-assembled monolayers (SAMs) with ATRP initiators were characterized by X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM). The thickness of grafted poly(SBMA) films was measured by ellipsometry. Fibrinogen adsorption on poly(SBMA) grafted surfaces was measured with a surface plasmon resonance (SPR) sensor. Two approaches were compared to graft ATRP initiators onto gold surfaces for surface polymerization and subsequent protein adsorption on these polymer grafted surfaces. The first was to prepare a SAM from omega-mercaptoundecyl bromoisobutyrate onto a gold surface. Superlow fouling surfaces with well-controlled poly(SBMA) brushes were achieved using this approach (e.g., fibrinogen adsorption <0.3 ng/cm2). The second approach was to react bromoisobutyryl bromide with a hydroxyl-terminated SAM on a gold surface. Although protein adsorption decreased as the density of surface initiators increased, the surface prepared using the second approach was not able to achieve as low protein adsorption as the first approach. Key parameters to achieve superlow fouling surfaces were studied and discussed.  相似文献   

16.
Coatings based on dendritic polyglycerol (dPG) were investigated for their use to control nonspecific protein adsorption in an assay targeted to analyze concentrations of a specific protein. We demonstrate that coating of the sample vial with dPG can significantly increase the recovery of an antibody after incubation. First, we determine the concentration dependent loss of an antibody due to nonspecific adsorption to glass via quartz crystal microbalance (QCM). Complementary to the QCM measurements, we applied the same antibody as analyte in an surface plasmon resonance (SPR) assay to determine the loss of analyte due to nonspecific adsorption to the sample vial. For this purpose, we used two different coatings based on dPG. For the first coating, which served as a matrix for the SPR sensor, carboxyl groups were incorporated into dPG as well as a dithiolane moiety enabling covalent immobilization to the gold sensor surface. This SPR-matrix exhibited excellent protein resistant properties and allowed the immobilization of amyloid peptides via amide bond formation. The second coating which was intended to prevent nonspecific adsorption to glass vials comprised a silyl moiety that allowed covalent grafting to glass. For demonstrating the impact of the vial coating on the accuracy of an SPR assay, we immobilized amyloid beta (Aβ) 1-40 and used an anti-Aβ 1-40 antibody as analyte. Alternate injection of analyte into the flow cell of the SPR device from uncoated and coated vials, respectively gave us the relative signal loss (1 − RUuncoated/RUcoated) caused by the nonspecific adsorption. We found that the relative signal loss increases with decreasing analyte concentration. The SPR data correlate well with concentration dependent non-specific adsorption experiments of the analyte to glass surfaces performed with QCM. Our measurements show that rendering both the sample vial and the sensor surface is crucial for accurate results in protein assays.  相似文献   

17.
疏水蛋白是丝状真菌产生的一种外泌蛋白质, 它们可以在不同表面形成双亲性蛋白膜. 疏水蛋白也是一种优良的蛋白质固定化基质, 然而蛋白质在疏水蛋白表面吸附的驱动机制却是未知的. 本文系统研究了不同pH和离子浓度下蛋白质在疏水蛋白表面的吸附. 首先, 用石英晶体微天平技术研究了不同pH和离子浓度下, Ⅰ型疏水蛋白HGFI和Ⅱ型疏水蛋白HFBI在聚苯乙烯表面的吸附. 结果发现, pH和离子强度对HGFI在聚苯乙烯表面的吸附影响较大, 对HFBI的吸附影响与HGFI相比则较小; HGFI在聚苯乙烯表面主要形成的是弹性膜, 而HFBI在聚苯乙烯表面主要形成的是刚性膜. 随后又研究了不同pH和离子浓度下牛血清白蛋白(BSA)和亲和素(Avidin)在HGFI和HFB上吸附, 结果表明, pH和离子强度对BSA和Avidin在HGFI和HFB上吸附有显著影响, 说明BSA和Avidin在两种疏水蛋白上吸附的主要驱动力为静电力. 本文研究结果为实现疏水蛋白表面可控地固定蛋白质提供了理论指导.  相似文献   

18.
Proteinaceous conditioning films (pCFs) are thought to play a key role in microbial adhesion, leading to the fouling of technical and biomedical devices and biofilm formation, which in turn causes material damage or persistent infections, respectively. However, little is definitively known about the process of surface conditioning via proteins. Herein, we demonstrate the potential of quartz crystal microbalance with dissipation coupled to MALDI-ToF mass spectrometry (QCM-D-MALDI) to investigate protein adsorption on different surfaces, enabling both the monitoring of CF formation and the determination of the molecular composition of CFs. After running QCM-D experiments, a subsequent tryptic on chip digestion step allows the identification of the proteins deposited on the sensor chip surface via MALDI-ToF mass spectrometry. Prominent blood plasma proteins, i.e., human serum albumin (HSA), fibrinogen (FG) and fibronectin (FN), were used. Chemically well defined sensor surfaces were prepared, among others, via self-assembled monolayer (SAM) technology. In cases where protein adsorption was observed by QCM-D, the adsorbed proteins were clearly detected and identified using MALDI-ToF/MS for both single-protein solutions of HSA, FG and FN as well as for protein mixtures. However, for equimolar protein mixtures on TiO2 surfaces, only signals attributed to FG and FN were observed in the mass spectra. No signals indicating the presence of HSA could be detected. This finding leads to the assumption that only FG and FN attach to the TiO2 sensor surface under the given experimental conditions.  相似文献   

19.
This study addresses the design of protein-repellent gold surfaces using hydroxyethyl- and ethyl(hydroxyethyl) cellulose (HEC and EHEC) and hydrophobically modified analogues of these polymers (HM-HEC and HM-EHEC). Adsorption behavior of the protein immunoglobulin G (IgG) onto pure gold and gold surfaces coated with cellulose polymers was investigated and described by quartz crystal microbalance with dissipation monitoring (QCM-D), atomic force microscopy (AFM) and contact angle measurements (CAM). Surfaces coated with the hydrophobically modified cellulose derivatives were found to significantly outperform a reference poly(ethylene glycol) (PEG) coating, which in turn prevented 90% of non-specific protein adsorption as compared to adsorption onto pure gold. HEC and EHEC prevented around 30% and 60% of the IgG adsorption observed on pure gold, while HM-HEC and HM-EHEC were both found to completely hinder biofouling when deposited on the gold substrates. Adsorption behavior of IgG has been discussed in terms of polymer surface coverage and roughness of the applied surfaces, together with hydrophobic interactions between protein and gold, and also polymer-protein interactions.  相似文献   

20.
A novel immunosensor based on surface plasmon resonance(SPR) has been developed for the recognition of antigen. The sensor was designed on the basis of the fixed angle of incidence and measuring the reflected intensities in a wavelength range of 430--750 nm in real-time. An ultra-bright white light-emitting diode(LED) was used as the light source. Molecular self-assembling in solution was used to form the sensing membrane on gold substrate. It has been seen that the sensitivity of the SPR sensor with 3-mercaptopropionic acid(MPA)/protein A(SPA) sensing membrane is considerably higher than that with MPA or SPA modified sensing membrane. The kinetic processes on the sensing membrane were studied. The human B factor(Bf), an activator of complement 3(C3), was recognized among the other antigens. This sensor can also be used for other antigen/antibody or adaptor/receptor recognition. Under optimized experimental conditions, the sensor has good selectivity, repeatability, and reversibility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号