首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 343 毫秒
1.
We describe a simple, environmentally friendly and selective technique for the determination of ochratoxin A (OTA) in urine. It involves (a) the use of a molecularly imprinted polymer as a sorbent in micro-solid-phase extraction in which the sorbent is contained in a propylene membrane envelope, and (b) separation and detection by capillary electrophoresis (CE). Under optimized conditions, response is linear in the range between 50 and 300 ng mL?1 (with a correlation coefficient of 0.9989), relative standard deviations range from 4 to 8 %, the detection limit for OTA in urine is 11.2 ng mL?1 (with a quantification limits of 32.5 ng mL?1) which is lower than those of previously reported methods for solid-phase extraction combined with CE. The recoveries of OTA from urine spiked at levels of 50, 150 and 300 ng mL?1 ranged from 93 to 97 %.
Figure
?  相似文献   

2.
We report on the use of hollow fiber liquid-liquid-liquid microextraction (HF-LLLME) followed by corona discharge ion mobility spectrometry for the determination of dextromethorphan and pseudoephedrine in urine and plasma samples. The effects of pH of the donor phase, stirring rate, ionic strength and extraction time on HF-LLLME were optimized. Under the optimized conditions, the linear range of the calibration curves for dextromethorphan in plasma and urine, respectively, are from 1.5 to 150 and from 1 to 100 ng mL?1. The ranges for pseudoephedrine, in turn, are from 30 to 300 and from 20 to 200 ng mL?1. Correlation coefficients are better than 0.9903. The limits of detection are 0.6 and 0.3 ng mL?1 for dextromethorphan, and 8.6 and 4.2 ng mL?1 for pseudoephedrine in plasma and urine samples, respectively. The relative standard deviations range from 6 to 8%.
Figure
Hollow fiber liquid–liquid–liquid microextraction (HF-LLLME) followed by corona discharge ion mobility spectrometry (CD-IMS) was used for the determination of dextromethorphan and pseudoephedrine in urine and plasma samples.  相似文献   

3.
Yaping Li 《Mikrochimica acta》2012,177(3-4):443-447
We report on a new scheme for the determination of the activity of caspase-3 using a specific peptide labeled with N-(4-aminobutyl)-N-ethylisoluminol (ABEI) as a chemiluminescent (CL) probe and on the development of magnetic separation technology. Firstly, the ABEI-labeled and biotinylated peptide was prepared and conjugated to streptavidin-coated magnetic beads (MBs) to form f-MBs (functionalized magnetic beads). The f-MBs contain a site (DEVD, Asp-Glu-Val-Asp) that is cleaved by caspase-3. Upon cleavage, the terminal residue attached to ABEI can dissociate from the f-MBs and can be used for CL detection. CL intensity is linearly related to the concentration of caspase-3 in the range 1.0 to 600 ng mL?1, with a detection limit of 0.3 ng mL?1. The relative standard deviation of the assay is 3.6 % at a level of 50 ng mL?1 of caspase-3 (for n?=?11). The CL assay has been applied to the determination of caspase-3 in Jurkat cell extract with recoveries between 96.6 % and 106.1 % (n?=?5).
Figure
A chemiluminescence assay for the detection of caspase-3 activity using N-(4-aminobutyl)-N-ethylisoluminol labeled specific peptide as CL probe coupling the magnetic separation technology was developed. The developed method has been applied to determination of caspase-3 in Jurkat cells extract with a satisfactory.  相似文献   

4.
We describe a new method for differential-pulse anodic stripping voltammetric determination of thallium(I) using a carbon paste electrode modified with dicyclohexyl-18-crown-6. The effect of supporting electrolyte (type and pH), accumulation and reduction potential, and of time and amount of modifier were investigated by differential pulse anodic stripping voltammetry. A method was then worked out for the determination of thallium at low levels. Under optimized conditions, the response to Tl(I) is linear in the range from 3.0 to 250 ng mL?1. The detection limit is 0.86 ng mL?1. The sensor displays good repeatability (with a relative standard deviation of ±2.70 % for n?=?7) and was applied to the determination of Tl(I) in water, hair samples, and certified reference materials.
Figure
Crown ethers allow only some ions to entry and complex formation that their sizes equal to ether cavity.  相似文献   

5.
We report on a combination of magnetic solid-phase extraction and spectrophotometric determination of bromate. Cetyltrimethylammonium ion was adsorbed on the surface of phenyl-functionalized silica-coated Fe3O4 nanoparticles (Ph-SiO2@Fe3O4), and these materials served as the sorbent. The effects of surfactant and amount of sorbent, the composition of the desorption solution, the extraction time and temperature were optimized. Under optimized conditions, an enrichment factor of 12 was achieved, and the relative standard deviation is 2.9 % (for n?=?5). The calibration plot covers the 1–50 ng mL?1 range with reasonable linearity (r 2?>?0.998); and the limit of detection is 0.5 ng mL?1. The method is not interfered by ionic compounds commonly found in environmental water samples. It was successfully applied to the determination of bromate in spiked water samples.
Figure
Extraction of bromate ions using surfactant-coated phenyl functionalized Fe3O4 magnetic nanoparticles followed by spectrophotometric detection.  相似文献   

6.
We report on a multiplex bead-based competitive immunoassay using suspension array technology for the simultaneous detection of the pesticides triazophos, carbofuran and chlorpyrifos. Three hapten-protein conjugates were covalently bound to carboxylated fluorescent microspheres to serve as probes. The amount of conjugates and antibodies were optimized. The new multi-analyte assay has dynamic ranges of 0.02–50 ng?mL?1, 0.5–500 ng?mL?1 and 1.0–1000 ng?mL?1 for triazophos, carbofuran and chlorpyrifos, respectively, and the detection limits are 0.024, 0.93 and 1.68 ng?mL?1. This new multiplex assay is superior to the traditional ELISA in possessing a wider detection range, better reproducibility and the feature of multi-target detection. Cross-reactivity studies indicated that the bead-array method is highly selective for the three target pesticides, and that individual analyses have no significant influence between each other, also without cross-reactions from other structurally related pesticides. The method was applied to analyze vegetables spiked with the three pesticides, and the recoveries were in ranges of 78.5–112.1 %, 72.2–120.2 % and 70.2–112.8 %, respectively, with mean coefficients of variation of <15 %.
Figure
Schematic illustration of the multiplex bead-based competitive immunoassay  相似文献   

7.
The fluorescent microsphere has been increasingly used as detecting label in immunoassay because of its stable configuration, high fluorescence intensity, and photostability. In this paper, we developed a novel lateral flow fluorescent microsphere immunoassay (FMIA) for the determination of sulfamethazine (SMZ) in milk in a quantitative manner with high sensitivity, selectivity, and rapidity. A monoclonal antibody to SMZ was covalently conjugated with the carboxylate-modified fluorescent microsphere, which is polystyrene with a diameter of 200 nm. Quantitative detection of SMZ in milk was accomplished by recording the fluorescence intensity of microspheres captured on the test line after the milk samples were diluted five times. Under optimal conditions, the FMIA displays a rapid response for SMZ with a limit of detection of as low as 0.025 ng mL?1 in buffer and 0.11 μg L?1 in milk samples. The FMIA was then successfully applied on spiked milk samples and the recoveries ranged from 101.1 to 113.6 % in the inter-batch assay with coefficient of variations of 6.0 to 14.3 %. We demonstrate here that the fluorescent microsphere-based lateral flow immunoassay (LFIA) is capable of rapid, sensitive, and quantitative detection of SMZ in milk.
Figure
Schematic illustration of the strategy for sulfamethazine detection using a lateral flow fluorescent microsphere immunoassay  相似文献   

8.
Graphene-based magnetic nanoparticles (G-Fe3O4) were prepared and used as an effective adsorbent for the solid-phase extraction of trace quantities of cadmium from water and vegetable samples. The method avoids some of the time-consuming steps associated with traditional solid phase extraction. The excellent sorption property of the G-Fe3O4 system is attributed to π - π stacking interaction and hydrophobic interactions between graphene and the Cd-PAN complex. The effects of pH, the amount of G–Fe3O4, extraction time, type and volume of eluent, desorption time and interfering ions on the extraction efficiency were optimized. The preconcentration factor is 200. Cd(II) was then quantified by flame atomic absorption spectrometry with a detection limit of 0.32 ng mL?1. The relative standard deviation (at 50 ng mL?1; for n?=?10) is 2.45 %. The method has a linear analytical range from 1.1 to 150 ng mL?1, and the recoveries in case of real samples are in the range between 93.1 % and 102.3 %.
Figure
General procedure for magnetic preconcentration of cadmium ions from aqueous solution using graphene-based magnetic nanoparticles  相似文献   

9.
An electrochemical sensor for palytoxin (PlTX) detection, based on a strip of eight screen-printed electrodes connected to a cost-effective and portable apparatus, is reported. Sheep erythrocytes were used to test the palytoxin detector and degree of haemolysis was evaluated by measuring release of the cytosolic lactate dehydrogenase (LDH). Percentage haemolysis and, therefore, the amount of LDH measured, by use of NADH/pyruvate and appropriate electrochemical mediators, was correlated with the concentration of the toxin. Two different electrochemical approaches were investigated for evaluation of LDH release, but only one based on the use of a binary redox mediator sequence (phenazine methosulfate in conjugation with hexacyanoferrate(III)) proved useful for our purpose. After analytical and biochemical characterization, the sensor strip was used to measure palytoxin. Sheep blood and standard solutions of PlTX were left to react for two different incubation times (24 h or 4 h), resulting in working ranges of 7?×?10?3–0.02 ng mL?1 and 0.16–1.3 ng mL?1, respectively. The specificity of the test for palytoxin was evaluated by use of ouabain, which acts in the same way as PlTX on the Na+/K+-ATPase pump. A cross-reactivity study, using high concentrations of other marine biotoxins was also conducted. Experiments to evaluate the matrix effect and recovery from mussels are discussed.
Figure
?  相似文献   

10.
We report on an ultrasensitive fluorescence immunoassay for human chorionic gonadotrophin antigen (hCG). It is based on the use of silica nanoparticles coated with a copolymer (prepared from a fluorene, a phenylenediamine, and divinylbenzene; PF@SiO2) that acts as a fluorescent label for the secondary monoclonal antibody to β-hCG antigen. In parallel, Fe3O4 nanoparticles were coated with polyaniline, and these magnetic particles (Fe3O4@PANI) served as a solid support for the primary monoclonal antibody to β-hCG antigen. The PF@SiO2 exhibited strong fluorescence and good dispersibility in water. A fluorescence sandwich immunoassay was developed that enables hCG concentrations to be determined in the 0.01–100 ng·mL?1 concentration range, with a detection limit of 3 pg·mL?1.
Figure
Fluorescence detection of prepared immune reagent nano-composites using the fluorescence cell  相似文献   

11.
A method was developed for the determination of cadmium(II) by ligand-less solid phase extraction that is based on the direct retention of Cd(II) in a mini-column filled with a silica gel modified with an amino-functionalized ionic liquid. The effects of pH, sample volume and its flow rate, eluent concentration and its volume, the flow rate of eluent, and of potential interferences on extraction and desorption were optimized. Following its determination by electrothermal atomic absorption spectrometry, the detection limit for Cd(II) is 8.9 ng L?1, and the relative standard deviation is 2.3 % (at 1.0 ng mL?1; for n?=?5). The method was applied to the analysis of Cd(II) in a certified reference material (laver; GBW10023), and the recoveries ranged from 97.0 to104.0 %
Figure
◆ Amino-functionalized ionic liquid modified silica gel (NH2-IL/SG) obtained a better absorption for Cd(II) than bare silica gel in the tested pH range due to electrostatic interaction between amino groups and Cd(II).  相似文献   

12.
We report that magnetic multiwalled carbon nanotubes functionalized with 8-aminoquinoline can be applied to the preconcentration of Cd(II), Pb(II) and Ni(II) ions. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Three variables (extraction time, magnetic sorbent amount, and pH value) were selected as the main factors affecting sorption, and four variables (type, volume and concentration of the eluent; elution time) were selected for optimizing elution. Following sorption and elution, the ions were quantified by FAAS. The LODs are 0.09, 0.72, and 1.0 ng mL?1 for Cd(II), Ni(II), and Pb(II) ions, respectively. The relative standard deviations are <5.1 % for five separate batch determinations at 30 ng mL?1 level of Cd(II), Ni(II), and Pb(II) ions. The sorption capacities (in mg g?1) of this new sorbent are 201 for Cd(II), 150 for Pb(II), and 172 Ni(II). The composite was successfully applied to the rapid extraction of trace quantities of heavy metal ions in fish, sediment, soil, and water samples.
Figure
A schematic diagram for synthesis of functionalized magnetic multiwalled carbon nanotube.  相似文献   

13.
In this research, a mixed immunoassay design for multiple chemical residues detection based on combined reverse competitive enzyme-linked immunosorbent assay (ELISA) procedure was developed. This method integrated two reverse ELISA reactions in one assay by labeling horseradish peroxidase to deoxynivalenol (DON) and orbifloxacin. Within this method, IC50 of the two mAbs for each analyte we produced ranged from 23?~?68 ng?mL?1 for DONs and 4.1?~?49 ng?mL?1 for quinolones (QNs). The limit of detection measured by IC10 was achieved at 0.45–1.3 ng?mL?1 for DONs and 0.59–6.9 ng?mL?1 for QNs, which was lower than the maximum residue levels. Recoveries in negative samples spiked at concentrations of 100, 200, and 500 ng?mL?1 ranged from 91.3 to 102.2 % for DONs and 88.7–98.05 % for QNs with relative standard deviation less than 9.88 and 12.67 %. The results demonstrated that this developed immunoassay was suitable for screening of low molecular weight contaminants.
Figure
Combined reverse ELISA procedure for multi-chemical residues analysis  相似文献   

14.
We report on a new kind of electrochemical immunosensors for simultaneous determination of the biomarkers carcinoembryonic antigen (CEA) and alpha-fetoprotein (AFP). Thionine and ferrocene were applied as distinguishable electrochemical tags (and mediators) which were covalently conjugated on anti-AFP and anti-CEA antibodies, respectively, via carboxy groups. The resulting conjugates were co-immobilized on a glassy carbon electrode functionalized with gold nanoparticles. Finally, horseradish peroxidase (HRP) was immobilized onto the modified electrode. Labeled thionine and ferrocene, respectively, act as distinguishable tags for simultaneous determination of AFP and CEA due to the difference in the location of their voltammetric peaks. With a one-step immunoassay format, the analytes in the sample produced transparent immunoaffinity reaction with the corresponding antibodies on the electrode. Once the immunocomplex is formed, it partially inhibits the active center of the immobilized HRP, and this decreased the activity of HRP in terms of reduction of hydrogen peroxide. This immunosensor enables the simultaneous determination of AFP and CEA in a single run and within the same dynamic range (0.01–50?ng?mL?1) and the same lower detection limit (0.01?ng?mL?1). The reproducibility and stability of the immunosensors are acceptable. The dual immunosensor was applied to evaluate several specimens, and the assay results are in acceptable agreement with clinical data.
Figure
This contribution devises a novel multiplexed electrochemical immunoassay for simultaneous detection of alpha-fetoprotein and carcinoembryonic antigen by using thionine and ferrocene as distinguishable signal tags on a one-spot immunosensor. The assay was performed by using one-step immunoreaction between the immobilized antibodies and the analytes. Although the linear range is relatively narrow, it completely meets the requirement of clinical diagnosis.  相似文献   

15.
We have developed a simple and fast immunochromatographic test strip for the simultaneous quantitation of aflatoxin B1 and aflatoxin B2 in corn and rice. The strip contains three pads (sample, conjugate, and absorbing pad) and uses the respective polyclonal antibodies immobilized on gold nanoparticles. Matrix interferences were minimized by application of fugacity theory. Clean-up of samples and pre-treatment of strip pads is not required. The visual detection limit is 0.1 ng mL?1, and the process can be completed within 5 min. Out of 113 natural samples, 16 rice and 27 corn samples (38% in total) were aflatoxin positive and the test results were confirmed by HPLC. The strip shows, however, high cross reactivity to aflatoxins G1, G2, and M1. We consider this strip to possess wide applicability because of its ease of use, sensitivity, stability, and low cost.
Graphical Abstract
Grain fungal infection often leads to aflatoxin production. A simple sensitive colloidal gold immunochromatographic strip for visual detection of aflatoxins B1 and B2 in corn and rice with detection limit of 0.1 ng mL-1 within 5 min was developed  相似文献   

16.
We describe a novel magnetic metal-organic framework (MOF) prepared from dithizone-modified Fe3O4 nanoparticles and a copper-(benzene-1,3,5-tricarboxylate) MOF and its use in the preconcentration of Cd(II), Pb(II), Ni(II), and Zn(II) ions. The parameters affecting preconcentration were optimized by a Box-Behnken design through response surface methodology. Three variables (extraction time, amount of the magnetic sorbent, and pH value) were selected as the main factors affecting adsorption, while four variables (type, volume and concentration of the eluent; desorption time) were selected for desorption in the optimization study. Following preconcentration and elution, the ions were quantified by FAAS. The limits of detection are 0.12, 0.39, 0.98, and 1.2 ng mL?1 for Cd(II), Zn(II), Ni(II), and Pb(II) ions, respectively. The relative standard deviations were <4.5 % for five separate batch determinations of 50 ng mL?1 of Cd(II), Zn(II), Ni(II), and Pb(II) ions. The adsorption capacities (in mg g?1) of this new MOF are 188 for Cd(II), 104 for Pb(II), 98 Ni(II), and 206 for Zn(II). The magnetic MOF nanocomposite has a higher capacity than the Fe3O4/dithizone conjugate. This magnetic MOF nanocomposite was successfully applied to the rapid extraction of trace quantities of heavy metal ions in fish, sediment, soil, and water samples.
Figure
A schematic diagram for synthesis of magnetic MOF-DHz nanocomposite.  相似文献   

17.
A novel test has been developed for the analysis of methadone in dried blood spot specimens from patients undergoing methadone maintenance treatment. An isocratic reversed-phase high-performance liquid chromatography method with coulometric detection has been optimized for the determination of methadone. The clean-up of dried blood spots was performed by means of an original microextraction by packed sorbent procedure after microwave-assisted extraction of the drug with a suitable solvent. Extraction yields were satisfactory, always being higher than 90.0 %. The calibration curve was linear over the 4–500 ng mL-1 concentration range. The method had satisfactory sensitivity (limit of quantitation of 4 ng mL-1), precision (relative standard deviation less than 5.8 %), selectivity and accuracy (recovery greater than 87.0 %). It was successfully applied to dried blood spot samples collected from heroin-addicted patients undergoing methadone maintenance therapy at dosages between 40 and 240 mg day-1. The statistical analysis (Bland–Altman plot) showed that the results were in good agreement with those found from the analysis of plasma samples obtained from the same patients. Thus, the method has proved to be suitable for the monitoring of methadone by means of dried blood spots.
Figure
Bland-Altman plot and methadone disposition in patients undergoing methadone maintenance treatment  相似文献   

18.
The anti-schizophrenic drug risperidone (RSP) exerts an inhibitory effect on the chemiluminescence (CL) of the luminol-lysozyme system. This finding forms the basis for a sensitive flow injection method for its determination at picogram levels. RSP binds to Trp62 in the lysozyme, and this leads to a conformational change upon which the CL of the system is quenched. The decrease in CL is proportional to the logarithm of the concentration of RSP, and the calibration graph is linear in the range from 0.1 pg?mL?1 to 1.0 ng?mL?1, with relative standard deviations of <5.0%, and a detection limit of 0.05 pg?mL?1 (3σ). At a flow rate of 2.0 mL?min?1, the whole process including sampling and washing is completed within 20 s. The method was successfully applied to monitoring RSP in human urine after incorporation of 2 mg of RSP, with a total excretion of 16.6% within 8.5 h.
Figure
The reaction of lysozyme with risperidone using luminol as luminescence reagent by the luminol-lysozyme FI-CL system and its application.  相似文献   

19.
A sensitive fluorescence liquid chromatographic analytical method was developed for the simultaneous determination of carnosine enantiomers in rat plasma. The method was applied to pharmacokinetic studies. Chiral separation of carnosine enantiomers was achieved by pre-column derivatization with o-phthaldialdehyde and the thiol N-acety-l-cysteine as derivating reagents. They were separated on an ODS column and detected by fluorescence detection (λex = 350 nm, λem = 450 nm). γ-Aminobutyric acid was used as internal standard. The method was linear up to 6,000 ng mL?1 for l-carnosine, 4,000 ng mL?1 for d-carnosine. Low limit of quantitation (LLOQ) was 40 ng mL?1 for each isomer. The relative standard deviations obtained for intra- and inter-day precision were lower than 12% and the recoveries were higher than 75% for both enantiomers. The method was applied to a stereoselective study on the pharmacokinetics of carnosine after oral administration with a single dose (carnosine, 75 mg kg?1 for each isomer) to a rat. The initial data indicated that l-carnosine had a larger value of the highest plasma concentration than d-carnosine (C max 5,344 vs. 1,914 ng mL?1), and that of l-carnosine had a lower value of AUC(0?∞) and t 1/2(h) (AUC(0?∞) 5,306 vs. 6,321 ng h mL?1, t 1/2 1.43 vs. 3.37 h). Our results indicated that the pharmacokinetic of l-carnosine and d-carnosine revealed enantioselective properties significantly.  相似文献   

20.
Solid-phase microextraction (SPME) based on carboxylated single-walled carbon nanotube fibers was used to extract several chlorophenols (CPs) and organochlorine pesticides (OCPs) from aqueous samples prior to their determination by GC with electron capture detection. The main parameters affecting microextraction (temperature, time, stirring rate and salting-out effect) and the conditions of the thermal desorption in the GC injector were optimized. Compared with commercial SPME fibers, the fiber presented better selectivity and sensitivity. Linear response was found for the concentration range between 2 and 1000 ng L?1 (20–1000 ng L?1 for CPs), and the limits of detection were in the range from 0.07 to 4.36 ng L?1. The repeatability expressed as relative standard deviation ranged from 4.1 % to 8.2 % and the fiber-to-fiber reproducibility for four prepared fibers was between 6.5 % and 10.8 %. The method was successfully applied to the analysis of CPs and OCPs in lake water and waste water samples. Recovery was tested with spiked lake water and waste water samples, with values ranging from 89.7 % to 101.2 % in case of waste water samples.
Figure
Raman spectra: (A) SWNTs, and (B) Oxidized SWNTs  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号