首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Using the extension of the concept of universal calibration parameter, yielding a relation between the hydrodynamic volume of molecules and the elution volume in size exclusion chromatography (SEC), to retention coefficients in ultrafiltration (UF), we propose a direct calibration of UF membranes against chromatography columns. Plotting the retention coefficient by one given UF membrane of a series of probe molecules versus their elution volume in SEC chromatography provides a calibration curve for this membrane. For a wide range of retentions, such calibration can be directly used to predict the retention of any molecule: one only needs to measure its exclusion volume by the SEC column, and read the retention by the calibrated membrane on the calibration curves.  相似文献   

2.
The effect of deuterated solvents in size-exclusion chromatography (SEC) was studied by comparing intrinsic viscosity measurements, SEC calibration curves, and column efficiency using water-soluble polymers. For aqueous SEC, the use of deuterium oxide slightly increases the SEC elution volume. To verify that adsorption onto the packing was absent, data from exclusion experiments were compared at 35 and 50 degrees C. Our results indicate that adsorption is not occurring for pullulan or polyethylene glycol (PEG)/poly(ethylene oxide) (PEO); for the latter, however, the elution volume increased using both D2O and H2O, indicative of slight hydrodynamic volume contraction of PEG/PEO at higher temperatures. A moderate increase in band broadening (moderate decrease in column efficiency) was observed using D2O. Finally, the effects of chloroform versus deuterated chloroform were evaluated, but no hydrodynamic volume changes were observed.  相似文献   

3.
Abstract

The mixture of methylene chloride/hexafluoroisopropanol (70/30, v/v) is an excellent polyester solvent, but its low boiling point causes unstable flow when it is used for size exclusion chromatography (SEC). In high-performance SEC experiments, retention time is normally used to measure elution volume; however, unstable flow makes it difficult to calibrate an SEC column set or calculate molecular weight parameters from a chromatogram. We have devised a simple and inexpensive method to compensate for the effect of unstable flow in SEC calculations. A calibration marker injected along with each sample is used to indicate flow-rate variations. The ratio of the sample retention time to the marker retention time is invariant to flow-rate changes and is used in place of retention time as a measure of elution volume in the universal calibration technique. Calibrating a column set and analyzing chromatograms by this method result in a large improvement in the accuracy and precision of calculated molecular weight parameters.  相似文献   

4.
This work attempts to obtain the calibration curves of two different size exclusion chromatography (SEC) columns operating with 1-methyl-2-pyrrolidinone (NMP) as eluent by using various standards. Polystyrene (PS) and polymethylmethacrylate (PMMA) standards were used for obtaining calibration curves, and checked against polysaccharide (PSAC) standards, some small aromatic polycyclic standards and miscellaneous polymers. Polystyrenes and polymethylmethacrylates gave identical calibrations while polysaccharides and miscellaneous polymers lay within 1 or 2 min of the polystyrene calibration. Small molecules of mass less than 1000 units lay on or near to the polystyrene calibration lines, with a shift to late elution for the smallest molecules. This shift may be caused by the interaction with the column packing. A sample has been examined by analytical size exclusion chromatography, which was calibrated using polystyrene and polymethylmethacrylate standards. Molecular mass (MM) distributions of the sample have been examined in terms of these calibrations.  相似文献   

5.
Size exclusion chromatography (SEC) is capable of evaluating the molecular weight distribution (MWD) of a sample. Information about the chemical composition distribution can be gained by gradient high performance liquid chromatography (gradient HPLC), where a poor starting eluent is, in the course of the separation, substituted by another one of increasing elution strength. Both normal-phase and reversed-phase systems can be employed. The combination of SEC and gradient HPLC enables chromatographic cross-fractionation to be performed efficiently.  相似文献   

6.
7.
Temperature rising elution fractionation hyphenated to size exclusion chromatography (TREF × SEC) is a routine technique to determine the chemical heterogeneity of semicrystalline olefin copolymers. Its applicability is limited to well crystallizing samples. High-temperature two-dimensional liquid chromatography, HT 2D-LC, where the chromatographic separation by HPLC is hyphenated to SEC (HPLC × SEC) holds the promise to separate such materials irrespective of their crystallizability. A model blend consisting of ethylene-vinyl acetate (EVA) copolymers covering a broad range of chemical composition distribution including amorphous and semicrystalline copolymers and a polyethylene standard was separated by HT 2D-LC at 140 °C. Both axes of the contour plot, i.e. the compositional axis from the HPLC and the molar mass axis from the SEC separation were calibrated for the first time. Therefore, a new approach to determine the void and dwell volume of the developed HT 2D-LC instrument was applied. The results from the HT 2D-LC separation are compared to those from a cross-fractionation (TREF × SEC) experiment.  相似文献   

8.
A straightforward size exclusion chromatography (SEC) method was developed and validated for the determination of total polivinylpyrrolidone (PVP) in ophthalmic solutions using the unusual combination of size exclusion chromatography (SEC), ultraviolet-visible detection and quantitation of an analyte peak that elutes in the total exclusion volume of the column. Samples of opthalmic solutions are diluted with water and injected onto a TSKgel G1000PW, 7.5 mm i.d. × 30 cm, 12 μm column at 50°C, with 80:20 0.1M sodium acetate-methanol mobile phase and UV detection at 220 nm. Validation was successful for a stability indicating pharmaceutical method, with parameters including specificity, accuracy, linearity, and precision within typical pharmaceutical acceptance criteria. A stress study with acid, base, peroxide, heat, and light indicates that there is no interference from drug, product, or excipients.  相似文献   

9.
Summary Controlled-porosity glasses (CPG) are sieves for macromoleculars, very widely applied in chromatographic columns for the separation of polymers and biopolymers by means of size-exclusion chromatography (SEC) and affinity chromatography. This paper deals with the influence of the thermal treatment of CPG on the elution of polymers in SEC columns. The problem is examined for a few mobile phases and for glasses having different porosities. Additionally, the SEC results obtained are compared with the adsorption properties of the glases investigated.  相似文献   

10.
Temperature rising elution fractionation hyphenated to size exclusion chromatography (TREF × SEC) is a routine technique to determine the chemical heterogeneity of semicrystalline olefin copolymers. A serious limitation is its applicability to non crystallizing samples. Comprehensive high temperature two-dimensional liquid chromatography (HT 2D-LC) gives an alternative to characterize the chemical heterogeneity of copolymers irrespective of their crystallizability. We have hyphenated interactive HPLC, which separates polyolefins according to their chemical composition, with high-temperature size exclusion chromatography (SEC), which distinguishes polyolefins with regard to their molar mass at 160 °C. The first separation step was based on a selective adsorption of macromolecules on a Hypercarb® column packed with porous graphite particles and subsequent desorption by a gradient 1-decanol → 1,2,4-trichlorobenzene at 160 °C. The SEC column was calibrated with polypropylene (PP) and polyethylene (PE) standards and it turned out that the injection solvent from the first dimension influenced the elution of PP in the SEC column, while the retention of PE was virtually constant. HT 2D-LC was then used to separate a broad variety of polyolefin blends containing PE, PP with different microstructure, ethylene–propylene (EP) and ethylene–propylene–diene (EP(D)M) rubber and ethylene/1-hexene copolymers. For the first time it has been shown that the elution of iPP in the gradient HPLC is molar mass dependent. The results from the HT 2D-LC separation were compared to those from TREF × SEC-experiments. The particular advantage of HT 2D-LC over TREF × SEC is the fact that HT 2D-LC is also applicable to non crystallizing polyolefin samples. The new technique therefore resolves the problem to analyze the chemical heterogeneity of non crystallizing olefin copolymers like EP and EP(D)M copolymers.  相似文献   

11.
Size exclusion chromatography (SEC), gradient polymer elution chromatography (GPEC) and liquid chromatography at critical conditions (LC-CC) have been developed and applied to observe chemical changes in poly(bisphenol A)carbonate (PC) due to hydrolytic degradation. Especially LC-CC appeared to be very successful to observe differences in functionality of PC as result of hydrolytic degradation. Observed differences due to degradation could be identified by (semi) on-line coupling to matrix assisted laser desorption-ionization time-of-flight mass spectrometry (MALDI-TOF-MS). The differences in functionality could be attributed to the formation of different end-groups, i.e. OH end-groups. In addition, comprehensive two-dimensional liquid chromatography (2D-LC) has been applied successfully to study the hydrolytic degradation of PC. LC-CC x SEC showed that the formation of PC with different end-groups occurred over the whole molecular mass range. This information could not be obtained with the separate liquid chromatographic techniques, thereby illustrating the added value of 2D-LC.  相似文献   

12.
Evidence of aggregation of amphoteric linear poly(amido-amine)s (PAAs) was proved using a multi-angle laser light scattering detector on-line to a size exclusion chromatography (SEC) system. As a rule the PAAs chemical structure, with the presence of charged groups that are both anionic and cationic, easily generates aggregation and non-steric fractionation. A non-amphoteric, non-aggregate PAAs polymer with an elution pattern close to ideal SEC was also obtained and characterized for comparison. The influence of PAAs synthesis conditions on the extent of aggregation was also studied.  相似文献   

13.
A gradient ranging from methanol to tetrahydrofuran (THF) was applied to a series of poly(methyl methacrylate) (PMMA) standards, using the recently developed concept of SEC-gradients. Contrasting to conventional gradients the samples eluted before the solvent, i.e. within the elution range typical for separations by SEC, however, the high molar mass PMMAs were retarded as compared to experiments on the same column using pure THF as the eluent. The molar mass dependence on retention volume showed a complex behaviour with a nearly molar mass independent elution for high molar masses. This molar mass dependence was explained in terms of solubility and size exclusion effects. The solubility based SEC-gradient was proven to be useful to separate PMMA and poly(n-butyl crylate) (PnBuA) from a poly(t-butyl crylate) (PtBuA) sample. These samples could be separated neither by SEC in THF, due to their very similar hydrodynamic volumes, nor by an SEC-gradient at adsorbing conditions, due to a too low selectivity. The example shows that SEC-gradients can be applied not only in adsorption/desorption mode, but also in precipitation/dissolution mode without risking blocking capillaries or breakthrough peaks. Thus, the new approach is a valuable alternative to conventional gradient chromatography.  相似文献   

14.
倪莉  陶冠军  戴军  王璋  许时婴 《色谱》2001,19(3):222-225
 可溶性丝素粉末经碱性蛋白酶Alcalase水解后 ,其酶解产物对血管紧张素转化酶 (ACE)的活性有很强的抑制作用。采用凝胶过滤色谱SephadexG 15和反相高效液相色谱 (RP HPLC)对水解度为 2 0 %的酶解产物进行分离纯化 ,利用质谱鉴定其中一种ACE抑制剂是肽 ,其结构为Gly Tyr。  相似文献   

15.
New approaches for the determination of the extent of symmetric and asymmetric band broadening (BB) in size exclusion chromatography (SEC) are presented. For this purpose raw data was simulated by starting with either a theoretical Poisson number chain length distribution (NCLD), or a log-normal weight chain length distribution (WCLD). Each distribution was first converted to a BB-free mass chromatogram, as typically obtained from a standard differential refractive index detector. Then, the broadened (or "measured") chromatograms were simulated by convoluting the BB-free chromatograms with a BB function, which was assumed to follow symmetrical (Gauss) as well as unsymmetrical (exponentially modified Gauss) function. A broad range of BB parameters (standard deviation, sigma(BB), and exponential decay, tau(BB)) was used for the simulations. The approaches are based on the determination of the points of inflection belonging to the peak of the broadened chromatogram, and closed as well as empirically derived equations connecting the peak width, its variance, and the parameters sigma(BB) and tau(BB). The developed methods are applicable for Poisson distributions well above a peak chain length of 100.  相似文献   

16.
Ma S  Chen L  Luo G  Ren K  Wu J  Wang Y 《Journal of chromatography. A》2006,1127(1-2):207-213
A comprehensive two-dimensional liquid chromatography system was constructed on the combination of size exclusion chromatography (SEC) and reverse phase liquid chromatography (RPLC). The first dimension used a SEC column with 300 mm x 8mm i.d., packed with Toyopearl HW-40S. The column was eluted with 0.05 mol/l Tris-HCl (pH 6.9) at a flow rate of 0.4 ml/min. The second dimension used a RPLC column with 100 mm x 4.6mm i.d., which was operated in gradient form at a flow rate of 1.0 ml/min. An automatic switching valve was used to collect the effluent of the SEC column every 3 min, and the effluent was automatically injected into the RPLC column. Mass spectrometer was used for peak identification. This system was used to separate Qingkailing injection, a traditional Chinese medicine (TCM). The result showed that the total peak capacity of this system could reach 1134 and the qualitative analysis of seven chemical components of the Qingkailing injection was accomplished by this system. The results show that comprehensive two-dimensional liquid chromatography system is of great importance and high value in the separation of complex TCM.  相似文献   

17.
Simulations of the distribution coefficients of linear polymers and regular combs with various spacings between the arms have been performed. The distribution coefficients were plotted as a function of the number of segments in order to compare the size exclusion chromatography (SEC)-elution behavior of combs relative to linear molecules. By comparing the simulated SEC-calibration curves it is possible to predict the elution behavior of comb-shaped polymers relative to linear ones. In order to compare the results obtained by computer simulations with experimental data, a variety of comb-shaped polymers varying in side chain length, spacing between the side chains and molecular weights of the backbone were analyzed by SEC with light-scattering detection. It was found that the computer simulations could predict the molecular weights of linear molecules having the same retention volume with an accuracy of about 10%, i.e. the error in the molecular weight obtained by calculating the molecular weight of the comb-polymer based on a calibration curve constructed using linear standards and the results of the computer simulations are of the same magnitude as the experimental error of absolute molecular weight determination.  相似文献   

18.
Monte Carlo simulations were conducted to estimate the elution curve of size exclusion chromatography (SEC). The present simulation can be applied to various types of branched polymers, as long as the kinetic mechanism of nonlinear polymer formation is given. We considered two types of detector systems, (1) a detector that measures the polymer concentration in the elution volume to determine the calibrated molecular weights, such as by using the differential refractive index detector (RI), and (2) a detector that determines the weight‐average molecular weight of polymers within the elution volume directly, such as a light scattering photometer (LS). For polydisperse star polymers, both detector systems tend to give a reasonable estimate of the true molecular weight distribution (MWD). On the other hand, for comb‐branched polymers, the RI detector underestimates the molecular weight of branched polymers significantly. The LS detector system improves the measured MWD, but still is not exact. The present simulation technique promises to establish various types of complicated reaction mechanisms for nonlinear polymer formation by using the SEC data quantitatively. In addition, the present technique could be used to reinvestigate a large amount of SEC data obtained up to the present to estimate the true MWD.  相似文献   

19.
The coupling of a low-pressure size exclusion chromatography (SEC) with a modified Ubbelohde capillary viscometer is described. This SEC/viscometry system measures the flow time of aliquot fractions (5ml) of the SEC effluent along with the refractive index change. This dual detection leads to the determination of the intrinsic viscosity as a function of the elution volume, thus allowing a precise use of Benoit's universal calibration. Moreover information of the branching factors (degree of long-chain branching, long-chain branching frequency) can be calculated under certain assumptions. As an example the changes in molar-mass distribution and branching factors during mechanical shear degradation (mastication) of special polychloroprene samples were investigated. It is shown that the SEC/viscometry system is especially suitable for the characterization of polymers with broad molar-mass distribution and extremely high molecular tails. The data provided by this method are useful for the investigation of the viscoelastic behaviour of concentated polychloroprene solutions and for quality control of polymers in the rubber and adhesives industries.  相似文献   

20.
The elution curves of size exclusion chromatography (SEC) for branched polymers formed through free‐radical polymerization that involves chain transfer to polymer were theoretically investigated by using a Monte Carlo method. We considered two types of measured molecular weight distribution (MWD), (1) the calibrated MWD relative to standard linear polymers, and (2) the MWD obtained by using a light scattering photometer (LS) in which the weight‐average molecular weight of polymers within the elution volume is determined directly. It was found that the calibrated MWD clearly underestimates the high molecular weight tail, and the measured distributions are narrower than the true MWD. On the other hand, the present simulation results showed that the LS method gives reasonable estimates of the true MWDs. The mean square radius of gyration of the polymer molecules having the same molecular weight was also investigated. The radii of gyration showed clear deviation from the Zimm‐Stockmayer equation[1] because of the non‐random nature of branched structure and the difference in the primary chain length distribution.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号