首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A sensitive and selective liquid chromatographic–tandem mass spectrometric (LC–MS–MS) method was developed to determine pantoprazole sodium (PNT) in human urine. After solid-phase extraction with SPE cartridge, the urine sample was analysed on a C18 column (symmetry 3.5 μm; 75 mm × 4.6 mm i.d) interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of acetonitrile–water (90:10, v/v). The method was linear over a concentration range of 1–100 ng mL?1. The lower limit of quantitation was 1 ng mL?1. The intra-day and inter-day relative standard deviation across three validation runs over the entire concentration range was <10.5%. The accuracy determined at three concentrations (8.0, 50.0 and 85.0 ng mL?1 PNT) was within ±1.25% in terms of relative errors.  相似文献   

2.
Current urinary bladder cancer diagnosis is commonly based on a biopsy obtained during cystoscopy. This invasive method causes discomfort and pain in patients. Recently, taurine and several other compounds such as L-phenylalanine and hippuric acid in urine were found to be indicators of bladder cancer. However, because of a lack of sensitive and accurate analytical techniques, it is impossible to detect these compounds in urine at low levels. In this study, using liquid chromatography–tandem mass spectrometry (LC-MS/MS), a noninvasive method was developed to separate and detect these compounds in urine. 15N2-L-glutamine was used as the internal standard, and creatinine acted as an indicator for urine dilution. A phenyl-hexyl column was used for the separation at an isocratic condition of 0.2% formic acid in water and 0.2% formic acid in methanol. Analytes were detected in multiple-reaction monitoring with positive ionization mode. The limit of detection range is 0.18–6 nM and the limit of quantitation ranges from 0.6 to 17.6 nM. The parameters affecting separation and quantification were also investigated and optimized. Proper clinical validation of these biomarkers can be done using this reliable, fast, and simple method. Furthermore, with simple modifications, this method could be applied to other physiological fluids and other types of diseases.  相似文献   

3.
The present article describes the development and validation of a LC–MS/MS method for the determination and confirmation of biomarkers of exposure to different types of xenobiotics in human urine. The method combines the use of a restricted access material (RAM) coupled on-line to a LC–IT-MS system; in this way, a rapid and efficient matrix cleanup was achieved, reducing manual sample preparation to freezing and sample filtration. The ion trap (IT) mass spectrometry detector provided the selectivity, sensitivity and ruggedness needed for confirmatory purposes. The on-line RAM-LC–MS/MS method developed here has been validated as a quantitative confirmatory method according to the European Union (EU) Decision 2002/657/EC. The validation steps included the verification of linearity, repeatability, specificity, trueness/recovery, reproducibility, stability and ruggedness in fortified urine samples. Repeatability and within-laboratory reproducibility, measured as intraday and interday precisions, were evaluated at two concentration levels, being 12.7% or below at the concentration corresponding to the quantification limits. Matrix effects and non-targeted qualitative analyses were also evaluated in fortified urine samples. Decision limits (CCα) and detection capabilities (CCβ) were in the range of 3.6–16.5 and 6.0–28.1 ng mL−1 respectively. The results of the validation process revealed that the proposed method is suitable for reliable quantification and confirmation of biomarkers of exposure to xenobiotics in human urine at low ng mL−1 levels. In addition, working in Data-Dependent Scan mode the proposed method can be used for the screening of these compounds in urine samples.  相似文献   

4.
Salinomycin is a polyether ionophore antibiotic that is widely used in poultry and livestock. Exposure of humans to salinomycin via inhalation or ingestion can cause severe toxicity. The aim of the present work was to develop a simple and sensitive liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for the rapid identification and quantification of salinomycin in human plasma. After removing protein using methanol, plasma samples were eluted from a Waters Xterra ® MS C18 column with an isocratic mobile phase. Detection and quantification of the drug were performed with a triple-quadruple mass spectrometer by monitoring for two specific transitions in the electrospray, positive-ion, multiple-reaction monitoring mode. Assay validation showed good linearity (r 2?=?0.998). The detection and quantification limits of the method were 0.6 and 16 pg/mL, respectively. The inter- and intraday coefficients of variation for the assay were both <15%. Twelve authentic plasma samples from intoxicated patients were analyzed using this method. Salinomycin was detected in six samples, at concentrations of between 0.6 and 46.5 pg/mL. The described assay method allows the sensitive and rapid identification and quantification of salinomycin in human plasma, and thus provides a valuable tool for the specific diagnosis of salinomycin intoxication in clinical and emergency rescue practice.  相似文献   

5.
6.
A rapid, sensitive, and selective liquid chromatography–tandem mass spectrometry method for the detection of tandospirone in human plasma is described. It was employed in a pharmacokinetic study. The analyte and internal standard diphenhydramine were extracted from plasma using liquid–liquid extraction, then separated on a Zorbax XDB C18 column using a mobile phase of methanol–water–formic acid (80:20:0.5, v/v/v). The detection was performed with a tandem mass spectrometer equipped with an electrospray ionization source. Linearity was established in the concentration range of 10.0-5,000 pg/ml. The lower limit of quantification was 10.0 pg/ml. The intraday and interday relative standard deviation across three validation runs over the entire concentration range was less than 13%. Accuracy determined at three concentrations (25.0, 200, and 4,000 pg/ml for tandospirone) ranged from 94.4 to 102.1%. Each plasma sample was chromatographed within 3.4 min. The method proved to be highly selective and suitable for bioequivalence evaluation of different formulations containing tandospirone and clinical pharmacokinetic investigation of tandospirone.  相似文献   

7.
The misuse of recombinant human erythropoietin (rhEPO) increases the proliferation/production of erythrocytes, which enhance oxygen transport capacities, and has grave consequences with respect to human health and fairness in sports. For sports drug testing, the current analytical methods for rhEPOs are mainly gel electrophoretic methods, such as isoelectric focusing–polyacrylamide gel electrophoresis. Mass spectrometry is fundamentally necessary for the reliable identification of rhEPOs in doping control. In this study, a high-sensitivity and high-throughput mass spectrometric qualitative detection method for darbepoetin alfa in human urine was established by a bottom-up approach. The novel method involves the immunopurification of human urine (10 mL), protease digestion with endoproteinase Glu-C (V8-protease) in an ammonium bicarbonate buffer (pH 7.8) and ultra-performance liquid chromatography using a charged surface hybrid C18 column coupled with electrospray-ionisation high-sensitivity tandem mass spectrometry for improved selectivity of the target molecules. The specific fragment digested from darbepoetin alfa was 90TLQLHVDKAVSGLRSLTTLLRALGAQKE117 (V11). The lower limit of detection of urinary darbepoetin alfa was 1.2 pg/mL. The limit of detection for the confirmation analysis was estimated to be 5 pg/mL. The developed method allows high-throughput confirmation analysis, namely 6 h for sample preparation and an analytical run time of only 10 min per sample; this high-throughput method dramatically decreases the workload in the laboratory. Darbepoetin alfa could be identified in human urine collected after the intravenous administration of 15 μg darbepoetin alfa (n?=?3). This mass spectrometric method is an innovative and powerful tool for detecting darbepoetin alfa in human urine for doping control testing.
Figure
Product ion mass spectrum of the specific peptide V11 after V8-protease digestion of darbepoetin alfa.  相似文献   

8.
A liquid chromatography–electrospray-tandem mass spectrometry (ES-MS/MS) method was developed for the speciation analysis of four organic selenium species of relevance to human urinary metabolism, namely trimethylselenomium ion (TMSe+), selenomethionine (SeMet) and the two selenosugars, methyl 2-acetamido-2-deoxy-1-seleno-β-d-galactos/-glucos-amine (SeGalNAc and SeGluNAc, respectively). Their chromatographic separation was achieved by using a cation exchange pre-column coupled in-series with a reversed-phase high-performance liquid chromatography column, along with an isocratic mobile phase. Online detection was performed using ES-MS/MS in selective reaction monitoring mode. SeGalNAc was detected as the major human urinary metabolite of selenium in the samples analysed, whereas TMSe+ was detected in the urine of one volunteer before and after receiving a selenium supplement. SeMet was not detected as a urine excretory metabolite in this study. Spiking experiments performed with the urine samples revealed significant signal suppression caused by coeluting matrix constituents. To overcome such interferences, isotopically labelled 13CD382SeGalNAc was used as an internal standard, whereas in the absence of an isotopically labelled internal standard for TMSe+, the standard addition method was applied. Quality control for the accurate quantitation of TMSe+ and SeGalNAc was carried out by analysing spiked human urine samples with appropriate selenium standards over a concentration range of 10–50 μg Se L−1. The method has achieved a limit of detection in the presence of urine matrix comparable to that of HPLC-inductively coupled plasma-mass spectrometry for the four selenium species: 1.0 μg Se L−1 for TMSe+, 5.6 μg Se L−1 for SeMet, and 0.1 μg Se L−1 for both SeGalNAc and SeGluNAc.  相似文献   

9.
Ribonucleosides are the end products of RNA metabolism. These metabolites, especially the modified ribonucleosides, have been extensively evaluated as cancer-related biomarkers. However, the determination of urinary ribonucleosides is still a challenge due to their low abundance, high polarity and serious matrix interferences in urine samples. In this study, a derivatization method based on a chemical reaction between ribonucleosides and acetone to form acetonides was developed for the determination of urinary ribonucleosides. The derivative products, acetonides, were detected by using liquid chromatography–tandem mass spectrometry (LC–MS/MS). The methodological evaluation was performed by quantifying four nucleosides for linear range, average recovery, precision, accuracy and stability. The validated procedures were applied to screen modified ribonucleosides in urine samples. Improvement of separation and enhancement of sensitivity were obtained in the analysis. To identify ribonucleosides, inexpensive isotope labeling acetone (acetone-d6) and label-free acetone were applied to form ordinary and deuterated acetonides, respectively. The two groups of samples were separated with orthogonal partial least squares (OPLS). The ordinary and deuterated pairs of acetonides were symmetrically distributed in the S-plot for easy and visual signal identification. After structural confirmation, a total of 56 ribonucleosides were detected, 52 of which were modified ribonucleosides. The application of derivatization, deuterium-labeling and multivariate statistical analysis offers a new option for selective detection of ribonucleosides in biological samples.  相似文献   

10.
Evodiamine and rutecarpine are two kinds of indole alkaloids contained in the fruit of Evodiae fructus, which have been shown to exhibit various bioactivities in humans. A liquid chromatography–tandem mass spectrometric method (LC–MS/MS) was developed for the determination of evodiamine and rutecarpine in human serum. The serum was extracted by solid-phase extraction (SPE) and analyzed using a C18 column and a mobile phase consisting of methanol–water (85:15) solution containing 5 mmol/L ammonium formate at a flow rate of 0.5 mL/min. The mass spectrometer was operated in positive mode, employing the extracted ion chromatogram (EIC) for detection and quantitation of evodiamine (m/z 288) and rutecarpine (m/z 304). Good linear relationships between the peak area and the concentration were obtained in the ranges of 5.2–1040 ng/mL and 10.2–1020 ng/mL, with correlation coefficients (r) of 0.999 and 0.998, for evodiamine and rutecarpine, respectively. The repeatabilities (RSD, n=6) of quantitation for evodiamine and rutecarpine were 2.18–4.00% and 2.99–5.67%, respectively, and the recovery ranged from 90.5% to 98.1%. A comparative study of the different ionization and quantitation modes, including ESI–MS, ESI–MS/MS, APCI–MS and APCI–MS/MS, was also accomplished. The MS/MS fragmentation mechanism of the base peak ([M+H]+, m/z 304) of evodiamine was investigated in order to identify the analytes in more complicated body fluid samples.   相似文献   

11.
We have developed a method for measuring 17 sulfonylurea (SU) herbicides in human urine. Urine samples were extracted using solid phase extraction (SPE), preconcentrated, and analyzed by high-performance liquid chromatography–tandem mass spectrometry using turboionspray atmospheric pressure ionization. Carbon 13-labeled ethametsulfuron methyl was used as an internal standard. Chromatographic retention times were under 7 minutes. Total throughput was estimated as >100 samples per day. Because only one labeled internal standard was available for the analysis, we were forced to reconsider and restructure the validation process to include stringent stability tests and analyses of urine matrices of differing compositions. We describe our restructured validation process and the critical evaluation it provides for the method developed. The limits of detection (LOD) ranged from 0.05 μg/L to 0.10 μg/L with an average LOD of 0.06 μg/L. Average total relative standard deviations were 17%, 12% and 8% at 0.1 μg/L, 3.0 μg/L and 10 μg/L, respectively. Average extraction efficiencies of the SPE cartridges were 87% and 86% at 2.5 μg/L and 25 μg/L, respectively. Chemical degradation in acetonitrile and urine was monitored over 250 days. Estimated days for 10% and 50% degradation in urine and acetonitrile ranged from 0.7 days to >318 days. The influence of matrix effects on precision and accuracy was also explored. Electronic Supplementary Material Supplementary material is available for this article at For additional information, contact Anderson Olsson at  相似文献   

12.
A novel method has been developed for the determination of alkylphenols in soil by ultra-high-pressure liquid chromatography employing small particle sizes, combined with tandem mass spectrometry. Soil samples were extracted with pressurized liquid extraction (PLE) and then cleaned with solid-phase extraction (SPE). The extracts were separated on C18 column (1.7 μm, 50 mm × 2.1 mm) with a gradient elution and a mobile phase consisting of water and acetonitrile, and then detected by an electrospray ionization tandem mass spectrometry in negative ion mode with multiple reaction monitoring (MRM). Compared with traditional liquid chromatography, it took ultra-high-pressure liquid chromatography much less time to analyze alkylphenols. Additionally, the ultra-high-pressure liquid chromatography/tandem mass spectrometry method produces satisfactory reliability, sensitivity, and accuracy. The average recoveries of the three target analytes were 74.0–103.4%, with the RSD < 15%. The calibration curves for alkylphenols were linear within the range of 0.01–0.4 μg/ml, with the correlation coefficients greater than 0.99. When 10 g soil sample was used for analysis, the limits of quantification (LOQs) of the three alkylphenols were all 1.0 μg/kg.  相似文献   

13.
A liquid chromatography–tandem mass spectrometry method for the simultaneous quantification of buprenorphine (BUP), norbuprenorphine (NBUP), buprenorphine glucuronide (BUP-Gluc), and norbuprenorphine glucuronide (NBUP-Gluc) in human urine was developed and fully validated. Extensive endogenous and exogenous interferences were evaluated and limits of quantification were identified empirically. Analytical ranges were 5–1,000 ng/mL for BUP and BUP-Gluc and 25–1,000 ng/mL for NBUP and NBUP-Gluc. Intra-assay and interassay imprecision were less than 17% and recovery was 93–116%. Analytes were stable at room temperature, at 4 °C, and for three freeze–thaw cycles. This accurate and precise assay has sufficient sensitivity and specificity for urine analysis of specimens collected from individuals treated with BUP for opioid dependence.  相似文献   

14.
A confirmatory method for the simultaneous determination of nandrolone (α and β) and trenbolone (α and β) in urine samples by liquid chromatography electrospray mass spectrometry (LC–MS-MS) was developed. After an enzymatic deconjugation, the urine was subjected to a one-step cleanup on a commercially available immunoaffinity chromatography cartridge. The analytes were detected by liquid chromatography–positive ion electrospray tandem mass spectrometry using deuterium labelled internal standards. The analytical procedure was applicable to bovine and swine urine samples. The procedure was validated as a quantitative confirmatory method according to the Commission Decision 2002/657/EC criteria. The results obtained showed that the method was suitable for statutory residues testing regarding the following performance characteristics: instrumental linearity, specificity, precision (repeatability and intra-laboratory reproducibility), recovery, decision limit (CCα), detection capability (CCβ) and ruggedness. The decision limits (CCα) obtained, were between 0.54 and 0.60 μg L−1; the recovery was above 64% for all the analytes. Repeatability was between 1.6% and 5.7% and within-laboratory reproducibility between 1.6% and 6.0% for all the steroids.  相似文献   

15.
Diabetic retinopathy is a major cause of vision loss in adults. Novel eye-drop formulations of candesartan and irbesartan are being developed for its cure or treatment. To support a preclinical trial in rabbits, it was critical to develop and validate a new LC–MS/MS method for simultaneous quantification of candesartan and irbesartan in rabbit eye tissues (cornea, aqueous humor, vitreous body and retina/choroid). Eye tissue samples were first homogenized in H2O-diluted rabbit plasma. The candesartan and irbesartan in the supernatants together with their respective internal standards (candesartan-d4 and irbesartan-d4) were extracted by solid-phase extraction. The extracted samples were injected onto a C18 column for gradient separation. The MS detection was in the positive electrospray ionization mode using the multiple reaction monitoring transitions of m/z 441 → 263, 445 → 267, 429 → 207, and 433 → 211 for candesartan, candesartan-d4, irbesartan and irbesartan-d4, respectively. For the validated concentration ranges (2–2000 and 5–5000 ng/g for candesartan and irbesartan, respectively), the within-run and between-run accuracies (% bias) were within the range of −8.0–10.0. The percentage CV ranged from 0.6 to 7.3. There was no significant matrix interference nor matrix effect from different eye tissues and different rabbits. The validated method was successfully used in the Good Laboratory Practice (GLP) study of rabbits.  相似文献   

16.
The first method for quantifying cannabinoids and cannabinoid glucuronides in whole blood by liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed and validated. Solid-phase extraction followed protein precipitation with acetonitrile. High-performance liquid chromatography separation was achieved in 16 min via gradient elution. Electrospray ionization was utilized for cannabinoid detection; both positive (Δ9-tetrahydrocannabinol [THC] and cannabinol [CBN]) and negative (11-hydroxy-THC [11-OH-THC], 11-nor-9-carboxy-THC [THCCOOH], cannabidiol [CBD], THC-glucuronide, and THCCOOH-glucuronide) polarity were employed with multiple reaction monitoring. Calibration by linear regression analysis utilized deuterium-labeled internal standards and a 1/x 2 weighting factor, yielding R 2 values >0.997 for all analytes. Linearity ranged from 0.5 to 50 μg/L (THC-glucuronide), 1.0–100 μg/L (THC, 11-OH-THC, THCCOOH, CBD, and CBN), and 5.0–250 μg/L (THCCOOH-glucuronide). Imprecision was <10.5% CV, recovery was >50.5%, and bias within ±13.1% of target for all analytes at three concentrations across the linear range. No carryover and endogenous or exogenous interferences were observed. This new analytical method should be useful for quantifying cannabinoids in whole blood and further investigating cannabinoid glucuronides as markers of recent cannabis intake.  相似文献   

17.
18.
This study used reversed-phase liquid chromatography–tandem mass spectrometry and supercritical fluid chromatography–tandem mass spectrometry for determination of the stereoisomers of chlorfenvinphos and dimethylvinphos in tobacco. Tobacco samples were extracted and purified with a modified quick, easy, cheap, effective, rugged, and safe technique using spherical carbon. The performance of both methodologies was comprehensively compared in terms of methods validation parameters (separation efficiency, linearity, selectivity, recovery, repeatability, sensitivity, matrix effect, etc.). Under optimized conditions, the calibration curves of the stereoisomers of chlorfenvinphos and dimethylvinphos in the range of 10–500 ng/mL showed excellent linearity with R2 ≥ 0.997 in both methods. The adequate recoveries of analytes from three different spiked tobaccos were obtained using reversed-phase liquid chromatography–tandem mass spectrometry (86.1–95.7%) as well as supercritical fluid chromatography–tandem mass spectrometry (86.5–94.0%). The relative standard deviations for spiked samples were all below 7.0%. Compared with supercritical fluid chromatography–tandem mass spectrometry, lower matrix effects and LODs can be obtained in reversed-phase liquid chromatography–tandem mass spectrometry.  相似文献   

19.
This paper describes a liquid chromatographic/tandem mass spectrometric (LC/MS–MS) method specifically designed for the screening of synthetic glucocorticosteroids in human urine. The method is designed to recognize a common mass spectral fragment formed from the particular portion of the molecular structure that is common to all synthetic glucocorticosteroids and that is fundamental to their pharmacological activity. As such, the method is also suitable for detecting unknown substances, provided they contain the portion of the molecular structure selected as the analytical target. The effectiveness of this approach was evaluated on seventeen synthetic glucocorticosteroids. Urine samples, including blank urines spiked with one or more synthetic glucocorticosteroids, were treated according to a standard procedure (enzymatic hydrolysis, liquid/liquid extraction and evaporation to dryness) and analyzed using LC/MS-MS with electrospray ionization (ESI). MS–MS acquisition was carried out in a precursor ion scan, and the results were compared with those obtained by a previously developed reference technique based on acquisition in the multiple reaction monitoring (MRM) mode. All of the glucocorticosteroids considered in this study are clearly detectable in urine, with a limit of detection in the concentration range 5–20 ng/mL, depending on the glucocorticosteroid structure. The proposed method is therefore suitable for the detection of glucocorticosteroids in urine samples taken for “in competition” sport anti-doping control tests, matching the requirements of the World Anti-Doping Agency (WADA) for accredited anti-doping laboratories. Figure Structures of the synthetic glucocorticoids considered in this study  相似文献   

20.
An advantage of differential mobility spectrometry (DMS) is it provides an orthogonal mechanism to mass spectrometry (MS). The DMS-MS/MS detects analytes in the gas phase on the basis of differences in ion mobility in low and high electric fields, which makes DMS-MS/MS an alternative to chromatographic separation-MS. One drawback of DMS is its limited resolution and sensitivity, especially for detecting small molecules when using a nonpolar inert gas as the carrier gas. The present work has evaluated the effects on peak capacity of adding chemical modifiers to inert carrier gases (nitrogen, helium, argon and carbon dioxide). Use of a methanol-helium mixture gave improvements in both separation and sensitivity. Nine structurally similar amphetamine-type stimulants were determined in urine without pretreatment of the samples before analysis. After optimization of carrier gas, nature and concentration of chemical modifier, and DMS temperature, limits of detection ranging from 1.1 to 2.7 ng mL−1, with a linear range of three orders of magnitude (5–5000 ng mL−1) were achieved. Precision was <15% and the accuracy of the quality control samples was 87.6–113.7%. For the quantitation of urine samples from drug abusers, data obtained using DMS-MS/MS showed reasonable agreement (within ±19.5%) with that obtained using LC-MS/MS. The analysis time for DMS-MS/MS was only 1.1 min and a paired sample t-test between the two methods gave a p-value of 0.0894, which indicates that DMS-MS/MS is a reliable method, with comparable precision and sensitivity to LC-MS/MS.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号