首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 328 毫秒
1.
The chemical composition of Matricaria chamomilla L. and Nepeta cataria L. essential oils was determined by GC-MS on an apolar stationary phase by comparison of the characteristic fragmentation patterns with those of the Wiley 275L database. The GC-MS chromatograms were compared with those obtained by fast GC equipped with a direct resistively heated column (Ultra Fast Module 5% phenyl, 5 mx 0.1 mm, 0.1 microm film thickness). Analytical conditions were optimised to reach a good peak resolution (split ratio=1:100), with analysis time lower than 5 min versus 35-45 min required by conventional GC-MS. The fast chromatographic method was completely validated for the analysis of mono- and sesquiterpene compounds. Essential oils were then fractionated by column chromatography packed with silica gel. Three main fractions with high degree of purity in E-beta-farnesene were isolated from the oil of M. chamomilla. One fraction enriched in (Z,E)-nepetalactone and one enriched in beta-caryophyllene were obtained from the oil of N. cataria. These semiochemical compounds could act as attractants of aphid's predators and parasitoids.  相似文献   

2.
The extremely large number of samples generated for the quality control analysis of combinatorial libraries that are developed in the pharmaceutical research for drug discovery requires fast generic methods such as rapid-gradient reversed-phase high-performance liquid chromatography (HPLC). These methods are necessary as standard procedures to produce up to several hundreds of analytical results per day and should be optimized in order to be applied to library products of widely differing polarities. This work presents an optimized generic method using a narrow-bore column packed with 1.5-microm nonporous particles and a completely automated HPLC workstation configured for the best efficiency, throughput, and robustness with this column. A test mix of 12 compounds with a wide polarity range is separated within 1.5 min with a cycle time of 3.5 min. The throughput is further enhanced using a Gilson 233XL dual-injection sampler to feed two parallel HPLC systems in order to perform 34 analyses per hour.  相似文献   

3.
A selective and sensitive coupled-column high-performance liquid chromatographic method is developed for the simultaneous determination of 5 phenylurea herbicides (monuron, linuron, isoproturon, monolinuron, and diuron) in environmental and drinking water samples. Sample clean-up is performed automatically by means of a column switching technique. Using 2 octadecyl silica columns connected via two programmable 6-port valves and ultraviolet detection at 244 nm, the aforementioned compounds can be determined at the low concentration levels required for pesticide residue analysis in water samples. A mobile phase consisting of a mixture of methanol-water (55:45, v/v) is pumped at 1 mL/min. For the 5 phenylureas, high recoveries ranging from 94.9 to 101.6%, good reproducibility with relative standard deviations lower than 5%, and wide linear ranges up to 20 micrograms/L are observed with determination limits of 0.05 microgram/L. The method is successfully applied to the screening of different environmental water samples such as surface, ground, rain, and drinking water.  相似文献   

4.
The potential of high-speed analyses by rapid resolution liquid chromatography (RRLC) and RRLC/MS on 1.8-microm porous particles packed into short columns operated at high flow-rate was investigated and compared with the performance of 5-microm porous particles packed into conventional columns. Using similar chemistries, the ease of conversion from conventional HPLC to an RRLC method was demonstrated. In order to display the practicality of RRLC separations, the analysis of pesticides in crops and catechins in Japanese green tea was selected. Using the Japanese Food Hygiene Law method, which employs a conventional 5-microm RP column (250 mm x 4.6 mm) for quantification of pesticides in crops, the analysis time was 25 min under isocratic conditions. Using the RRLC method on the short (50 mm x 4.6 mm) column packed with 1.8-microm porous particles, the same separation could be performed in 0.8 min with the RRLC/MS method without a loss in resolution. At the highest flow rate, compared to the conventional method, the time could be reduced by a factor of 31. In gradient elution, the fastest separation of catechins in Japanese green tea was achieved by RRLC on 50-mm x 4.6-mm id or 50-mm x 2.1-mm id RRLC columns packed with 1.8-microm particles. The analysis time at 5 mL/min was less than 1 min. Compared to the conventional HPLC method on a 150-mm column packed with 5-microm particles, time was reduced by a factor of 15. The effect of other experimental parameters such as the column temperature, acquisition rate of the detector and the influence of cell volume on chromatographic performance was also investigated. After the optimization, the analysis precision under the fastest RRLC conditions was examined. RSDs of retention time and peak area were 0.2% and 0.47%, respectively.  相似文献   

5.
邹春苗  张小东  于泓  关超  王淼煜 《色谱》2015,33(7):759-764
建立了整体柱离子对色谱-间接紫外检测和填充柱离子对色谱-间接紫外检测分析四乙基铵根离子的两种方法。用反相整体柱和反相填充柱,以咪唑离子液体-离子对试剂-有机溶剂为流动相,研究了背景紫外吸收试剂、检测波长、离子对试剂、有机溶剂、柱温和流速对测定四乙基铵根离子的影响,比较了两种色谱柱的差异,并讨论了保留规律。在优化的实验条件下,两种方法测定四乙基铵根离子的保留时间分别是2.40和3.02 min;检出限分别是0.04和0.07 mg/L;峰面积的相对标准偏差分别是0.16%和0.11%;保留时间的相对标准偏差分别是0.02%和0.01%。将这两种方法用于分析实验室合成的溴化四乙基铵离子液体,加标回收率分别为98.2%和99.1%。两种方法均能满足四乙基铵根离子测定的需要。  相似文献   

6.
反相高效液相法测定血清中的佐匹克隆   总被引:5,自引:0,他引:5  
杨丽君 《色谱》2002,20(3):256-258
 建立了测定血清中佐匹克隆的反相高效液相法 (外标法 )。血样用正丁基氯提取后进行分离。采用的柱为LiChroCART 12 5 4柱 (LiChrospher 6 0RPselectB填料 ,5 μm ,12 5mm× 4mmi d ) ,流动相为乙腈 0 0 2mol/LKH2 PO4缓冲溶液 (体积比为 2 0∶80 ) ,紫外检测波长为 2 5 4nm。当佐匹克隆在血清中的添加质量浓度分别为 4 0 0 μg/L ,16 0 0 μg/L和6 4 0 0 μg/L时 ,血清中佐匹克隆的回收率分别是 (73 4± 3 2 ) % ,(82 2± 4 1) %和(90 3± 4 5 ) %。方法的最低检出限为 15 μg/L。方法适用于法庭毒物分析 ,简便、快速。  相似文献   

7.
建立双柱串联–便携式气相色谱测法定室内空气中苯系物的方法。利用仪器内部自带的Tenax吸附剂在0.5 L/min流量下采集空气样品100 s,然后仪器迅速升温至400℃左右,对吸附剂进行热解吸进样,以微亚离子检测器(MAID)对室内空气中7种苯系物进行测定。结果表明,色谱条件为MXT–200/MXT–WAX金属毛细管柱串联色谱柱,柱温90℃,柱压103 425 Pa时,分离效果最好,且运行时间短。各组分在19.26~306.7μg/m~3范围内与色谱峰面积的平方根线性关系良好,相关系数r大于0.995。方法检出限为6.40~15.9μg/m~3,空白加标回收率为92%~114%,测定结果的相对标准偏差为6.1%~13.7%(n=6)。采用双柱串联便携式气相色谱法测定室内空气中苯系物具有快速、准确、方便等优点。  相似文献   

8.
New drinking water regulations require the monitoring of eight volatile organic compounds that have established maximum contaminant levels (MCLs) and 51 other volatile organics for which MCLs are not established. A laboratory analytical method (Method 524.2) for the determination of 58 of these compounds is investigated, and precision and accuracy data are obtained. The method uses a standard inert gas purge extraction, isolation of the volatile organics on a three-stage solid-phase trap, thermal desorption into a gas chromatograph, separation with a fused-silica capillary column, and identification and measurement with a relatively low cost, benchtop ion trap detector that functions as a mass spectrometer. At a concentration of 2 micrograms/L (2 parts per billion), the grand mean measurement accuracy for 54 compounds was 95% of the true value with a mean relative standard deviation (RSD) of 4%. At 0.2 micrograms/L (200 parts per trillion), the grand mean measurement accuracy for 52 compounds was 95% of the true value with a mean RSD of 3%.  相似文献   

9.
赵彦  徐董育  林浩学  陈晓燕  陈泽勇 《色谱》2014,32(6):662-665
建立了一种采用填充柱切割-反吹二维气相色谱分析汽油中酯类化合物(包括乙酸乙酯、乙酸仲丁酯、碳酸二甲酯)的方法。利用非极性填充预柱将汽油中沸点低于正辛烷的轻组分保留进入分析柱,重组分反吹放空,轻组分和酯类化合物经一个装填有强极性固定相的色谱柱分离分析。采用外标法定量,3种酯类化合物在50~50000 mg/L范围内线性关系良好,相关系数(r2)分别为0.99999、1.00000和0.99995,标准样品6次重复性测定的相对标准偏差(RSD)均小于1.0%,回收率在98.7%~107.9%之间,方法检出限(S/N=3)为5 mg/L。该方法不需要进行样品前处理,具有操作简单,准确高效的特点,是汽油中酯类化合物测定的理想分析方法。  相似文献   

10.
刘敬兰  陈连文  周鸿娟 《色谱》1999,17(1):95-96
 建立了新型多元复合液肥中丁二酸、戊二酸、己二酸的气相色谱分析方法。色谱条件:5%SE-30不锈钢填充柱,程序升温,内标物为丙二酸二乙酯,3种二元酸二乙酯分别在2.3~9.3μg,10.8~43.2μg和2.8~11.0μg质量范围内,其样品质量与样品峰面积和内标峰面积之比呈良好的线性关系,相关系数r≥0.9955。  相似文献   

11.
反相高效液相色谱法测定尿中吡啶醚和脱氧吡啶醚   总被引:13,自引:0,他引:13  
翁建平  廖瑛  余斌杰 《色谱》1997,15(6):521-523
尿中吡啶醚(pyridinoline,PYD)和脱氧吡啶醚(deoxypyridinoline,DPD)是骨代谢特异的生化指标。应用高效液相色谱法(HPLC)建立了尿中PYD和DPD的测定方法。尿液用6mol/LHCl水解后,以纤维素CF1小柱提取,然后用HPLC测定;色谱系统为SpherisorbC18反相色谱柱,流动相组成为15%甲醇添加0.1%七氟丁酸,流速为1.2mL/min。系统的检测限:PYD为10nmol/L,DPD为7nmol/L;回收率:PYD为91.5%,DPD为106.1%;日内变异  相似文献   

12.
A simple, rapid and reproducible reversed-phase high-performance liquid chromatographic method for the simultaneous determination of benzoic acid (BA), phenylacetic acid (PAA) and their respective glycine conjugates hippuric acid (HA) and phenaceturic acid (PA) in sheep urine is described. The procedure involves only direct injection of a diluted urine sample, thus obviating the need for an extraction step or an internal standard. The compounds were separated on a Nova-Pak C18 column with isocratic elution with acetate buffer (25 mM, pH 4.5)-methanol (95:5). A flow-rate of 1.0 ml/min, a column temperature of 35 degrees C and detection at 230 nm were employed. These conditions were optimized by investigating the effects of pH, molarity, methanol concentration in the mobile phase and column temperature on the resolution of the metabolites. The total analysis time was less than 15 min per sample. At a signal-to-noise ratio of 3 the detection limits for ten-fold diluted urine were 1.0 microgram/ml for BA and HA and 5.0 micrograms/ml for PAA and PA with a 20-microliters injection.  相似文献   

13.
A high-performance liquid chromatographic multiresidue method was developed for the determination of 8 penicillin compounds (benzylpenicillin, phenoxymethylpenicillin, ampicillin, amoxicillin, nafcillin, oxacillin, cloxacillin, and dicloxacillin) at trace levels in muscle tissue. This method involves extraction of the penicillins with phosphate buffer pH 9 followed by cleanup and concentration on a C18 solid-phase extraction column and reaction with benzoic anhydride at 50 degrees C for 5 min and with 1,2,4-triazole and mercury(II) chloride solution pH 9 at 65 degrees C for 10 min. The derivatized compounds are eluted on a C8 column with a mobile phase containing acetonitrile and phosphate buffer (pH 6; 0.1 mol/L) loaded with sodium thiosulfate and ion-pairing tetrabutylammonium hydrogenosulphate. The method detection limit is approximately 3-11 micrograms/kg and the limit of determination was evaluated down to 25 micrograms/kg in line with the criteria of the EU decision No. 93/256/EEC.  相似文献   

14.
A simple, accurate and precise isocratic reversed-phase high-performance liquid chromatographic method was developed and validated for the determination of p-chloronitrobenzene (p-CNB) in rat plasma. A plasma sample was deproteinized with methanol containing the internal standard (p-bromonitrobenzene). The resulting methanol eluate obtained after centrifugation was filtered and injected into a high-performance liquid chromatograph (50 microliters each). A column packed with 5 microns octadecylsilane (ODS) spherical particles was used with isocratic elution of methanol-water (45:55, v/v) at a flow-rate of 1.0 ml/min. The compounds were detected by ultraviolet absorbance at 280 nm. The retention times of p-CNB and the internal standard were 12.5 and 15.5 min, respectively, at a column oven temperature of 30 degrees C. The results were linear from 0.05 to 100 micrograms/ml (r = 0.999), and the detection limit was 0.01 microgram/ml. The relative error and the coefficient of variation on replicate assays were less than 7 and 10%, respectively, for all concentrations studied. The overall recoveries of p-CNB were between 97 and 105%. Plasma samples could be stored for up to one month at -20 degrees C.  相似文献   

15.
In this work, the simultaneous analysis of five triazolopyrimidine sulfoanilide herbicides (flumetsulam, florasulam, metosulam, cloransulam-methyl, and diclosulam) by HPLC using UV detection and a C18 monolithic column is proposed. The mobile phase which was composed of ACN, water, and formic acid was pumped at a high flow rate (5 mmL/min) providing an analysis time of all the compounds in less than 2.3 min. The LODs were in the low microg/L range (i.e. between 60 microg/L for flumetsulam and 90 microg/L for florasulam) and the calibration curves showed good linearity (R2 > 0.9949). The method was applied to the analysis of these compounds in spiked mineral and tap waters and soils after an SPE preconcentration procedure using C18 cartridges. Mean recovery values ranged between 35 and 110% for water samples providing LODs of the whole procedure in the low ng/L level, down to 280 ng/L, and between 77 and 92% for soil samples with LODs down to 9.38 microg/kg. This is the first time that this family of pesticides is simultaneously analyzed in both types of samples by HPLC and also using a monolithic column.  相似文献   

16.
A simple high performance liquid chromatographic method has been devised for the measurement of bisoprolol in plasma or serum. The sample (200 microL) is vortex mixed for 30 s with 2 M Tris solution (50 microL), aqueous internal standard (benzimidazole, 2.0 mg/L, 50 microL) and methyl t-butyl ether (200 microL). After centrifugation (9950 x g, 2 min), a portion of the resulting extract is analysed on a microparticulate (5 microns) silica column using 1 mM camphorsulphonic acid in methanol as the mobile phase. Detection is by fluorescence at an excitation wavelength of 215 nM. The lower limit of accurate measurement for the assay is 10 micrograms/L (CV% = 8.9, n = 9) with a lower limit of detection of 5 micrograms/L. There is minimal interference from either commonly prescribed drugs or endogenous compounds.  相似文献   

17.
申书昌  张文治  王文波 《色谱》2002,20(3):269-271
 采用顶空气相法测定了氯乙烯生产过程产生的盐酸溶液中的乙炔和氯乙烯。使用氢氧化钠将试样中的氯化氢中和 ,从而消除其在气相分析乙炔和氯乙烯中的影响。顶空平衡温度为 35℃ ,平衡时间为 4 5min ,柱为填充了GDX 2 0 2固定相的 2m× 3mmi d 不锈钢柱 ,柱温 14 0℃。顶空气体进样量为 1mL。以外标法定量 ,乙炔含量测定结果的相对标准偏差为 0 85 % ;当其含量为 30 0 μg/g~ 15 0 μg/g时 ,回收率为 98 9%~10 3%。氯乙烯含量测定结果的相对标准偏差为 1 4 % ;当其含量为 2 0 0 μg/g~ 10 0 μg/g时 ,回收率为 98 8%~10 2 %。  相似文献   

18.
Determination of carbonyl compounds in air by electrochromatography   总被引:5,自引:0,他引:5  
Fung YS  Long Y 《Electrophoresis》2001,22(11):2270-2277
A new analytical procedure based on electrochromatography was developed for the separation and quantitation of 14 aldehydes and ketones (formaldehyde, acetaldehyde, acetone, acrolein, propionaldehyde, butanone, crotonaldehyde, isobutyraldehyde/butyraldehyde, 2-pentenaldehyde, isovaleraldehyde, valeraldehyde, benzaldehyde and hexanaldehyde) in ambient air currently to be regulated by the Hong Kong Environmental Protection Department. A volatile mobile phase using ammonium acetate compatible with mass spectrometry detection was developed and optimized as follows. Methanol: acetonitrile: aqueous buffer (4 mM ammonium acetate) = 65:5:30% v/v. With electrokinetic injection at 5 kV for 2 s, aqueous buffer pH adjusted to 8, applied voltage controlled at 25 kV, and detection at 360 nm in a fused-silica column packed with 3 microm ODS, a satisfactory separation was obtained for the 14 carbonyl compounds investigated. The working ranges in acetonitrile solution were found to vary from 0.25 to 79 mg/L with a correlation coefficient greater than 0.99, detection limits from 0.10 to 0.63 mg/L, and precision (relative standard deviation, n = 3) from 2.3 to 9.2%. Under an air flow rate of 0.3 L/min for a sampling time of 1 h, the working ranges varied from 0.030 to 11,000 microg/m3 and detection limits from 0.011 to 0.084 microg/ m3. The method has been successfully applied to monitor three carbonyl compounds in four urban and rural sites in Hong Kong and gave hourly readings of three carbonyl compounds for all the sites investigated with a separation time less than 25 min.  相似文献   

19.
气相色谱-质谱法测定氯氮平及其去甲基代谢物   总被引:9,自引:0,他引:9  
建立了测定人血清中氯氮平及其去甲基代谢物的柱前衍生化气相色谱-质谱选择离子监测的分析方法。以三氟乙酸酐作酰化剂,对衍生化条件和样品预处理方法实施了优化。氯氮平和去甲氯氮平的线性范围为1~128μg/L,最低检测浓度:氯氮平为0.1μg/L,去甲氯氮平为0.2μg/L,两者的回收率均大于83%,相对标准偏差都小于10%。将所建立的方法应用于服用细胞色素氧化酶P4501A2抑制剂前后低剂量氯氮平的药代动力学自身对照试验中,结果显示氯氮平的代谢水平明显受P4501A2活性的影响。  相似文献   

20.
A?conceptual adsorption process for the recovery and purification of biobutanol is proposed. Different porous materials are tested on their ability to perform the adsorptive separations relevant to the process. The metal-organic framework ZIF-8, silicalite zeolite and active carbon were compared with respect to their adsorption capacity of 1-butanol dissolved in water, as obtained in static and dynamic conditions by respectively batch and breakthrough measurements at room temperature. Batch experimentation showed that other compounds present in a real ABE fermentation have no significant effect on the adsorption of 1-butanol on ZIF-8. The breakthrough separation of 1-butanol from an aqueous ABE mixture was performed with a ZIF-8 packed column. The desorption of 1-butanol from a saturated ZIF-8 packed column by a stepwise increase of the temperature to 423?K in combination with a purge of a nitrogen gas (60?ml/min) shows that 1-butanol desorbs at low temperature from ZIF-8. Adsorption isotherms of ethanol, 1-butanol and water in liquid phase on the zeolite SAPO-34 were determined by batch adsorption at 298?K. Also the separation of an ethanol/1-butanol mixture and the removal of ethanol from 1-butanol could be achieved with a SAPO-34 packed column. From this experimental work, two materials—ZIF-8 and SAPO-34—thus emerged as suitable adsorbents for the recovery and purification of biobutanol by adsorption.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号