首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A routine high performance liquid chromatographic method for the rapid determination of fleca?nide (Flecaine), using a novel internal standard, N-methylfleca?nide, has been developed. After deproteinization of spiked samples, fleca?nide was totally recovered at neutral pH. Fleca?nide and the internal standard were separated on a reversed phase XL 3 microns ODS column using 10 mM phosphate buffer, pH 3.0: acetonitrile (70:30) as mobile phase, in less than 10 min. With spectrofluorometric detection, the limit of quantitation for fleca?nide was 10 ng/mL. Intra- and inter-assay precision variations were 0.24% and 1.4%.  相似文献   

2.
A simple gas chromatographic method for the determination of clonazepam in human plasma has been developed. After solvent extraction, the compound is measured by an electron capture detector on an OV-17 column. The electron-capture response is linear for 5-120 ng/ml of plasma. There is no interference from other commonly used anti-epileptic drugs or endogenous substrates. Preliminary data from routin monitoring of epileptic patients shows a 10-fold variation in their clonazepam plasma levels.  相似文献   

3.
4.
Docosanoic (C22), tetracosanoic (C24) and hexacosanoic (C26) acids are saturated very-long-chain fatty acids (VLCFA) present at trace levels in biosamples. VLCFA can be used as potential biomarkers for the diagnosis of hereditary diseases such as X-linked adrenoleukodystrophy. Because the analytes to be detected are at trace levels, a sensitive fluorimetric liquid chromatographic method was developed to analyze VLCFA in plasma. The method is simple based on extracting VLCFA from plasma with toluene, and the obtained toluene extract was subject to the derivatization of VLCFA with a fluorescent reagent 2-(2-naphthoxy)ethyl-2-(piperidino)ethanesulfonate (NOEPES) without solvent evaporation/replacement. The resulting fluorescent derivatives were monitored by fluorimetric detection (excitation at 225 nm and emission at 360 nm), giving a high sensitivity with the limit of detection about 5.0 nM (S/N = 3, 10 μL injected) of the analytes. Application of the method to the analysis of VLCFA in the plasma of patients with adrenoleukodystrophy proved practical and effective.  相似文献   

5.
Vitamins A and E are fat‐soluble vitamins that play important roles in several physiological processes. Monitoring their concentrations is needed to detect deficiency and guide therapy. In this study, we developed a high‐performance liquid chromatography method to measure the major forms of vitamin A (retinol) and vitamin E (α‐tocopherol and γ‐tocopherol) in human blood plasma. Vitamins A and E were extracted with hexane and separated on a reversed‐phase column using methanol as the mobile phase. Retinol was detected by ultraviolet absorption, whereas tocopherols were detected by fluorescence emission. The chromatographic cycle time was 4.0 min per sample. The analytical measurement range was 0.03–5.14, 0.32–36.02, and 0.10–9.99 mg/L for retinol, α‐tocopherol, and γ‐tocopherol, respectively. Intr‐aassay and total coefficient of variation were <6.0% for all compounds. This method was traceable to standard reference materials offered by the National Institute of Standards and Technology. Reference intervals were established using plasma samples collected from 51 healthy adult donors and were found to be 0.30–1.20, 6.0–23.0, and 0.3–3.2 mg/L for retinol, α‐tocopherol, and γ‐tocopherol, respectively. In conclusion, we developed and validated a fast, simple, and sensitive high‐performance liquid chromatography method for measuring the major forms of vitamins A and E in human plasma.  相似文献   

6.
7.
8.
Zopiclone is a hypnosedative with clinical effects similar to benzodiazepines but thought to have less potential for rebound insomnia and withdrawal effects. Zopiclone is administered as a racemic mixture, and an enantiospecific method of analysis of zopiclone in plasma is desirable in the study of pharmacokinetic drug interactions. We report a modification of an HPLC method reported by Foster et al. using a closely related structural analogue of zopiclone as internal standard. Zopiclone was detected at 306 nm and linear calibration curves were constructed in the range of 1.0-250 ng/mL for each enantiomer. The % CV at 2.5 ng/mL was 12.0% for (-)-zopiclone and 14.3% for (+)-zopiclone, and the limit of quantification of each enantiomer was 2.5 ng/mL. At higher concentrations, the coefficient of variation was less than 10%. The nominal concentration of quality control samples was predicted with an accuracy within a range of +/-11.6%. The method was used in the analysis of plasma obtained from psychiatric patients. One sample obtained following a non-fatal overdose with zopiclone contained the metabolites (-)-N-oxide zopiclone and both enantiomers of desmethyl zopiclone. The metabolite enantiomers were resolved on the column with retention times similar to zopiclone. The N-oxide metabolite co-eluted with internal standard.  相似文献   

9.
A simple high-performance liquid chromatographic (HPLC) method was developed and validated for rapid quantification of linezolid in human plasma. Protein precipitation using a mixture of 5% trichloroacetic acid and methanol (3:1, v/v) provided a straightforward method of sample preparation and the internal standard eperezolid was employed. A concentration range from 0.20 to 40.0 mg/L was utilized to construct calibration curves, and analysis of low- (0.40 mg/L), medium- (7.50 mg/L) and high-quality (25.0 mg/L) control samples revealed excellent reproducibility (相似文献   

10.
Two high-performance liquid chromatographic methods are described for the assay of theophylline in plasma. Both allowed the separation of theophylline from the caffeine metabolites, theobromine and 1,7-dimethylxanthine. Method A, using 8-chlorotheophylline as internal standard, involved back extraction of theophylline from organic extract with 0.1 M sodium hydroxide. Method B used generally accepted solvent extraction followed by evaporation and beta-hydroxyethyltheophylline as internal standard. High-performance liquid chromatographic analyses were performed on reversed-phase phenyl columns (25 X 0.46 and 25 X 0.41 cm) using 20% methanol in 20 mM phosphate buffer at pH 5.6 for Method A and 2% acetonitrile and 8% methanol in 20 mM phosphate buffer for Method B. The column effluent was monitored at UV 273 nm. Standard curves for both Methods A and B were fitted by linear regression (r greater than 0.999) in the concentration range of 0.05-50 micrograms/ml. Either method was selective, accurate and reproducible over the concentration range 0.08-26 micrograms/ml. However, compared with Method B, Method A provided significant advantages in terms of simplicity, speed and efficiency.  相似文献   

11.
12.
Phenoprolamine hydrochloride is a novel compound that works against a variety of types of hypertension. The purpose of this study was to develop a simple and sensitive high-performance liquid chromatographic method for quantitation of low phenoprolamine hydrochloride concentrations in human plasma and to apply it to pharmacokinetic study. The procedure involved extraction of the drug and clonidine (internal standard) from the plasma using diethyl ether. Chromatographic separations were carried out on a 4.6 x 200 mm Hypersil silica column with UV detection at 230 nm. The isocratic mobile phase, 1% ammonium acetate (pH 5.4) and methanol (0.3:99.7, v/v), was run at 1 mL/min. Extraction recovery was 84% for phenoprolamine hydrochloride at a concentration level of 200 ng/mL, and 76% for clonidine at 200 ng/mL. The method was linear in the concentration range 5-4000 ng/mL with a lower limit of quantitation of 5 ng/mL for phenoprolamine hydrochloride. Inter- and intra-day coefficients of variation were less than 10%. The validated method was successfully applied to a pharmacokinetic study in human after an oral administration of the drug, and the pharmacokinetic parameters are presented.  相似文献   

13.
14.
A rapid and quantitative method for the extraction, derivatization, and liquid chromatography with fluorescence detection of ivermectin (IVM) and doramectin (DOM) residues in porcine liver was developed and validated. IVM and DOM were extracted from the liver samples with acetonitrile, the supernatant was evaporated to dryness at 37 degrees C under nitrogen, and the residue was reconstituted in 1-methylimidazole solution. After 2 min at room temperature, IVM and DOM were converted to a fluorescent derivative and then separated on a Hypersil ODS column. The derivatives of IVM and DOM were detected and quantitated with high specificity by fluorescence (excitation: 365 nm, emission: 475 nm). Abamectin was used as an internal standard. The mean extraction efficiencies from fortified samples (15 ng/g) were 75% for IVM and 70% for DOM. The limit of detection was 0.8 ng/g for both IVM and DOM.  相似文献   

15.
A high-performance liquid chromatographic method with ultraviolet detection at 210 nm for quantitation of bupivacaine and two of its metabolites from plasma and urine is described. The compounds are extracted into n-hexane-isopropanol (5:1), evaporated and the reconstituted residue injected onto a reversed phase C18 column. Standard curves for all compounds were linear (r2 greater than 0.999) in the range 20-2000 ng/ml, with a limit of detection of 10 ng/ml. The inter-day coefficients of variation ranged between 2.7 and 12.2%. The method was applied to analyse bupivacaine and metabolite concentrations in patients on long-term epidural bupivacaine-fentanyl infusions.  相似文献   

16.
A sensitive method for the determination of oxycodone concentrations in plasma by high-performance liquid chromatography (HPLC)-electrospray ionization-triple quadrupole mass spectrometry is described. The method is rugged, reliable, selective, and rapid with a run time of 2 min. One milliliter of plasma is made basic and extracted with 2-mL duplicate portions of 2% isoamyl alcohol in n-butyl chloride. The combined extracts are then evaporated to dryness, reconstituted in 100 microL of the mobile phase (15% methanol-85% water containing 0.1% acetic acid), and injected onto the HPLC. The limit of quantitation is 1 ng/mL, and the estimated limit of detection is 33 pg/mL (signal-to-noise = 3). Standard curves are linear over the range of 1 to 100 ng/mL with all correlation coefficient values greater than 0.9989. The method is used to determine the concentration of oxycodone in human plasma following the intravenous infusion of doses ranging from 5 to 15 mg in which the analysis of over 3000 plasma samples is required.  相似文献   

17.
18.
A simple and sensitive liquid chromatographic method is described for the quantitative analysis of gabapentin in human plasma. Gabapentin (GBP) is an anticonvulsant and widely used in the treatment of epilepsy. No peculiar chromophore is available on gabapentin moiety for direct analysis by absorption spectrophotometry. In human plasma after deproteinisation with acetonitrile, gabapentin was derivatized with a fluorescent reagent, (2-naphthoxy)acetyl chloride (NAC) in borate buffer (pH 10.0). The resulting naphthoxy derivative of gabapentin was separated on a phenyl-hexyl column with a mobile phase consisting of a mixture of sodium acetate buffer (100 mM; pH 5.0)-methanol (32:68, v/v) used in isocratic mode. Using fluorimetric detection (excitation at 225 nm and emission at 360 nm), a low detection limit of about 0.04 microM (S/N = 3, 10 microl injected) was reached. The relative standard deviations (RSD) of the method for intra- and inter- day analyses (n = 5) are between 2.7 and 4.0%, respectively. The method was successfully applied to the analysis of gabapentin in plasma from dosed patients for therapeutic drug monitoring.  相似文献   

19.
20.