首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 718 毫秒
1.
A method is described for the simultaneous determination of organophosphorus and triazine pesticides in olive oil, whereby reversed-phase liquid chromatography (LC) is coupled to gas chromatography by means of an automated through-oven transfer adsorption-desorption (TOTAD) interface. The olive oil needs to be filtered only before it is loaded into the liquid chromatograph, where preseparation of the pesticide residues from the other olive oil components is carried out by using methanol-water as the eluant. The LC fraction containing the pesticides is automatically transferred to the gas chromatograph by using the TOTAD interface, which almost totally eliminates the solvent, so that water-sensitive detectors such as the nitrogen-phosphorus detector can be used. Detection limits range from 0.07 to 0.38 microg/L for organophosphorus pesticides and from 6.0 to 7.0 microg/L for triazines. The results were compared with those obtained by flame ionization detection.  相似文献   

2.
Addition of a reactant gas to a low pressure microwave-induced plasma creates a reaction interface in which complex molecules are converted into small polyatomic neutral species. For a given reactant gas the array of these small molecules reflect s the elemental composition of the original analyte. In this study HCI has been found highly effective as a reactant gas for selective detection of sulfur-eontaining compounds using capillary gas chromatography/ chernical reaction interface mass spectrometry. Detection limits as low as 30 pg of a sulfur-containing compound and a dynamic range of two orders of magnitude were achieved.  相似文献   

3.
Colloid attachment to liquid–gas interfaces is an important process used in industrial applications to separate suspended colloids from the fluid phase. Moving gas bubbles can also be used to remove colloidal dust from surfaces. Similarly, moving liquid–gas interfaces lead to colloid mobilization in the natural subsurface environment, such as in soils and sediments. The objective of this study was to quantify the effect of moving air–water interfaces on the detachment of colloids deposited on an air-dried glass surface, as a function of colloidal properties and interface velocity. We selected four types of polystyrene colloids (positive and negative surface charge, hydrophilic and hydrophobic). The colloids were deposited on clean microscope glass slides using a flow-through deposition chamber. Air–water interfaces were passed over the colloid-deposited glass slides, and we varied the number of passages and the interface velocity. The amounts of colloids deposited on the glass slides were visualized using confocal laser scanning microscopy and quantified by image analysis. Our results showed that colloids attached under unfavorable conditions were removed in significantly greater amounts than those attached under favorable conditions. Hydrophobic colloids were detached more than hydrophilic colloids. The effect of the air–water interface on colloid removal was most pronounced for the first two passages of the air–water interface. Subsequent passages of air–water interfaces over the colloid-deposited glass slides did not cause significant additional colloid removal. Increasing interface velocity led to decreased colloid removal. The force balances, calculated from theory, supported the experimental findings, and highlight the dominance of detachment forces (surface tension forces) over the attachment forces (DLVO forces).  相似文献   

4.
In this study, peak-broadening effects caused by nebulizing gas flow and lack of temperature control have been investigated for separation capillaries with three different inner diameters. The study was performed with serial UV/ESI-MS detection in an effort to distinguish between peak broadening arising in the separation and peak broadening arising in the ion source. The nebulizing gas was found to significantly affect both migration time and separation efficiency when using capillaries with 50 and 75 microm id. If the nebulizing gas is on during injection, the injection volume increases to such an extent that significant peak broadening is induced. Reducing the id to 25 microm minimizes the parabolic flow induced by the nebulizing gas. Results indicate that the nebulizing gas pressure can be optimized to minimize peak broadening in the ion source. A decrease in detection sensitivity, possibly related to the orthogonal design of the interface, was observed when the nebulizing gas pressure was increased. A tapered capillary tip was found to provide superior separation efficiency as well as sensitivity.  相似文献   

5.
Here, we present a miniaturized version of the flowing atmospheric-pressure afterglow (miniFAPA) ion source and use it for sheathless coupling of CE with MS. The simple design of the CE-miniFAPA-MS interface makes it easy to separate the electric potentials used for CE and for ionization. A pneumatically assisted nebulization of the CE effluent transfers the analytes from the liquid phase into the gas phase before they are ionized by interacting with reactive species produced by the FAPA. An important advantage of this interface is its high stability during operation: optimization of five different parameters indicated that the interface is not sensitive to minor deviations from the optimum values. Other advantages include ease of construction and maintenance, as well as relatively low cost. Samples with complex matrices, such as yeast extract, soil extract and urine, spiked with the test compounds, were successfully analyzed using the CE-miniFAPA-MS setup.  相似文献   

6.
We have established a method for separation and characterization of a series of peptide hormones of pharmaceutical interest and wide therapeutical use by capillary electrophoresis-electrospray-mass spectrometry (CE-ES-MS) using a sheath flow interface. Several parameters were systematically investigated, such as concentration of the electrolyte, organic solvent and sheath liquid composition, gas flow rates and capillary position. Moreover, limits of detection, linearity, repeatability and day-to-day reproducibility of the proposed method were studied in order to obtain the main quality parameters.  相似文献   

7.
唐伟  王兢 《物理化学学报》2016,32(5):1087-1104
金属氧化物异质结由于费米能级效应、不同组分之间的协同作用,常被用来提高电阻型金属氧化物半导体气体传感器的气敏特性。本文简述了近年来国内外金属氧化物异质结材料的类别,主要分为混合氧化物结构、层状结构、第二相粒子修饰结构、一维纳米结构和核-壳结构;重点综述了金属氧化物异质结的气敏增强机理,包括异质结效应、协同效应、催化溢流效应、响应反型、载流子分离及微结构调控六大机理;分析了当前异质结气体传感器面临的瓶颈。最后对纳米异质结气体传感器的发展进行了展望,今后金属氧化物异质结气体传感器可以从明确异质结界面机理展开,这将为自下而上地设计出符合实际需要的气体传感器提供一定参考。  相似文献   

8.
The gas permeabilities of thin liquid films stabilized by poly(N-isopropylacrylamide) (PNIPAM) and PNIPAM-SDS (sodium dodecyl sulfate) mixtures are studied using the "diminishing bubble" method. The method consists of forming a microbubble on the surface of the polymer solution and measuring the shrinking rates of the bubble and the bubble film as the gas diffuses from the interior to the exterior of the bubble. PNIPAM-stabilized films exhibit variable thicknesses and homogeneities. Interestingly, despite these variable features, the gas permeability of the film is determined principally by the structure of the adsorbed polymer layer that provides an efficient gas barrier with a value of gas permeability coefficient that is comparable to that of an SDS Newton black film. In the presence of SDS, both the film homogeneity and the gas permeability coefficient increase. These changes are related to interactions of PNIPAM with SDS in the solution and at the interface, where coadsorption of the two species forms mixed layers that are stable but that are more porous to gas transfer. The mixed PNIPAM-SDS layers, studied previously for a single water-air interface by neutron reflectivity, are further characterized here in a vertical free-draining film using X-ray reflectivity.  相似文献   

9.
由于大多数水合物客体不溶于水,水相与客体相界面首先形成一层气体水合物膜,气体水合物膜生长是水合物生长的主要形式,研究水合物膜生长规律对于理解水合物生长动力学及进一步开发促进和抑制水合物生长的应用技术具有重要意义.本文综述了近年来气体水合物膜生长形态、横向生长和增厚生长的理论和实验研究进展.首先介绍了不同客体-水体系(包括气/液界面、液/液界面和气-液-液体系)形成的水合物膜生长形态随实验条件的变化规律,然后分别从横向生长和增厚生长两方面总结了水合物膜生长的实验和模型方面的研究工作,阐述了常见的膜生长速率和膜厚度的测量方法,分析了水合物膜生长的传热和传质机理.同时展望了未来水合物膜生长研究的发展方向.  相似文献   

10.
A new configuration for coupling a purge-and-trap unit to a capillary column gas chromatograph via a cryogenic focusing interface has been developed. In this configuration, the precolumn of the cryogenic focusing interface was inserted through the septum of a split/splitless injection port where it served as both sample transfer and carrier gas supply lines. The injection port of the gas chromatograph was modified by plugging the carrier gas and the septum purge lines. This configuration allowed for the desorption of analytes at high flow rates while maintaining low, analytical-column flow rates which are necessary for optimum capillary column operation. The capillary column flow rate is still controlled by the column backpressure regulator. Chromatograms of purgeable aromatics exhibited improved resolution, especially for early eluting components compared to those obtained by direct liquid injection using the normal splitless injection mode. Quantitative sample transfer to the analytical column afforded excellent linearity and reproducibility of compounds studied.  相似文献   

11.
Processes that inject gases such as carbon dioxide and natural gas have long been and still continue to be used for recovering crude oil from petroleum reservoirs. It is well known that the interfacial tension between the injected gas and the crude oil has a major influence on the efficiency of displacement of oil by gas. When the injected gas becomes miscible with the crude oil, which means that there is no interface between the injected and displaced phases or the interfacial tension between them is zero, the oil is displaced with maximum efficiency, resulting in high recoveries. This paper presents experimental measurements of interfacial tension between crude oil and natural gases (using a computerized drop shape analysis technique) as a function of pressure and gas composition at the temperature of the reservoir from which the crude oil was obtained. The point of zero interfacial tension was then identified from these measurements by extrapolation of data to determine minimum miscibility pressure (MMP) and minimum miscibility composition (MMC). The gas-oil miscibility conditions thus obtained from interfacial tension measurements have been compared with the more conventional techniques using slim-tube tests and rising-bubble apparatus as well as predictive correlations and visual observations. The miscibility pressures obtained from the new VIT technique were 3-5% higher than those from visual observations and agreed well with the slim-tube results as well as with the correlations at enrichment levels greater than 30 mol% C2+ in the injected gas stream. The rising bubble apparatus yielded significantly higher MMPs. This study demonstrates that the VIT technique is rapid, reproducible, and quantitative, in addition to providing visual evidence of gas-oil miscibility.  相似文献   

12.
This paper describes and characterizes a new interface for organic solvent sample introduction into atom reservoirs for analytical atomic spectrometry, especially for inductively coupled plasmas. The unoptimized analyte transport efficiencies were in a range between 45 and 65 % and the solvent removal efficiencies were 80–100 % using Freon and chloroform as solvents. The interface gives - for inductively coupled plasmas - a higher analyte transport efficiency at optimum solvent load in comparison with normal nebulizer systems. The interface is easy to optimize since all gas and liquid flows can be varied independently. The interface provides for optimum coupling of analytical liquid flow techniques to instruments for analytical atomic spectrometry.  相似文献   

13.
Off-lineTwo-DimensionalGasChromatography-MassSpectrometryforAnalysisofEssentialOilofMedicinalHerb──UseofAbsorptionTrapMAXue-y...  相似文献   

14.
The construction and evaluation of an interface for two-dimensional gas chromatography is described. The interface consists of commercially available components and is attachable to available gas chromatographs without any major modifications. The interface has been constructed so as to permit “heartcutting” as well as solute band concentration. Trapping is performed in a simple cold trap of fused silica. Flow switching is accomplished by Deans switching. Factors of the over-all chromatographic performance are examined.  相似文献   

15.
The thermal stability of ribonuclease S (RNase S), an enzymatically active noncovalent complex composed of a 2166-u peptide (S-peptide) and a 11,534-u protein (S-protein), was investigated by electrospray ionization mass spectrometry (ESI-MS) and capillary electrophoresis ESI-MS (CE-ESI-MS). The intensities of peaks corresponding to the RNase S complex were inversely related to both the applied nozzle-skimmer (or capillary-skimmer) voltage bias in the atmosphere-vacuum interface and the temperature of the RNase S solution. By using a heated metal capillary-skimmer interface and a room temperature solution of RNase S, the intensities of RNase S molecular ion peaks were observed to decrease with increasing metal capillary temperature. Mass spectrometric studies with both the nozzle-skimmer and capillary-skimmer interface designs allowed determination of phenomenological enthalpies for dissociation of the RNase S complex in both solution and for the electrosprayed microdroplet-gas phase species. Intact RNase S complex could also be detected with CE-ESI-MS separations by using a 10-mM ammonium bicarbonate (pH 7.9) solution as the electrophoretic buffer. These studies provide new insights into the stability of multiply charged noncovalent complexes in the gas phase and the mass spectrometric conditions required for such studies, and suggest that information regarding solution properties can be obtained by ESI-MS.  相似文献   

16.
This paper describes several successful cost-effective attempts to couple capillary electrophoresis (CE) and mass spectrometry (MS) without make-up flow or nebulizing gas. An in-depth analysis of several interfaces using conductive spray tips was performed as well as an easy-to-prepare T-junction with direct electrode contact, the latter being the most robust interface. No coating is necessary and the spray voltage is applied through a gold wire positioned at the gap between the separation and spray capillaries. The T-junction interface is made by puncturing a small piece of transparent rubber. The on-line preconcentration CE-MS system allows immunoassay sensitivity, as is demonstrated by a calibration plot in the picomolar range for angiotensin II and gonadorelin. It also shows good reproducibility and has the ability of excellent automation. The secure electrical contact gives a constant spray quality, even with 100% aqueous separation buffers. The described setup has a wide applicability as is demonstrated by the analysis of larger peptides, such as insulin and cytochrome c. Detailed information is given on critical factors in the preparation of the described interfaces.  相似文献   

17.
To simply evaluate toxicity for various types of exhaust-gas samples collected in various locations, we developed a small-scale (150 mL) batch-type completely closed gas exposure device incorporated with an air-liquid interface culture of a human alveolar epithelial cell line, A549. On the basis of cell viability tests using an acid phosphatase assay after 48 h of gas exposure, the developed device was able to measure clear dose-response relationships for volatile organic and inorganic compounds, such as benzene, trichloroethylene (TCE), acetone, SO(2) and NO(2) gases, but not CO gas. Although the 50% effective concentration values in the device were much higher than 50% lethal concentration values reported in animal experiments, the tendency of the toxic intensity observed in the former was roughly consistent with that of the acute toxicity in the latter. We further applied the device to evaluate the toxicity of cigarette smoke as an example of actual environmental gases, and successfully measured acute cell death from the gas after 48 h of exposure. The present small device is expected to be one of good tools not only in simultaneously assessing various gaseous chemicals or samples, but also in studying acute toxicity expression mechanisms in human lung epithelia.  相似文献   

18.
The long‐range attractive force or “snap‐in” is an important phenomenon usually occurring when a solid particle interacts with a water/gas interface. By using PeakForce quantitative nanomechanics the origin of snap‐in in the force curve between the atomic force microscopy (AFM) probe and the water/gas interface of nanobubbles has been investigated. The snap‐in frequently happened when the probe was preserved for a certain time or after being used for imaging solid surfaces under atmospheric conditions. In contrast, imaging in liquids rarely induced a snap‐in. After a series of control experiments, it was found that the snap‐in can be attributed to hydrophobic interactions between the water/gas interface and the AFM probe, which was either modified or contaminated with hydrophobic material. The hydrophobic contamination could be efficiently removed by a conventional plasma‐cleaning treatment, which prevents the occurring of the snap‐in. In addition, the adsorption of sodium dodecyl sulfate onto the nanobubble surface changed the water/gas interface into hydrophilic, which also eliminated the snap‐in phenomenon.  相似文献   

19.
This study was focused on examining the influence of gas flow parameters on capillary electrophoresis/mass spectrometry (CE /MS) performance using sheath-liquid CE /MS interfaces. The effects of nebulizing and drying gas velocity and drying gas temperature on CE separation and MS detection sensitivity were systematically determined. Nebulizing gas velocity was observed to be a critical parameter in the optimization of CE /MS method, since it affected both MS detection sensitivity, and also CE separation efficiency for one interface design tested. Better detection sensitivity was obtained when the nebulizing gas velocity was increased. However, high velocity of the nebulizing gas flow can cause a hydrodynamic bulk flow inside the CE capillary, thus clearly increasing the apparent mobility and decreasing the resolution obtained for the compounds studied. Increasing the drying gas velocity or temperature did not affect the apparent mobility or the separation efficiency and the temperature could be increased to achieve the optimal detection sensitivity in the CE /MS analysis. For comparison, the effects of nebulizing gas flow were studied using a different design of the coaxial sheath-liquid CE /MS interface, and in this case better detection sensitivity but no effect on CE separation efficiency was observed with increased nebulizing gas velocity. These different effects of nebulizing gas flow on the CE bulk flow were concluded to result from pressure differences at the tip of the CE capillaries for the different CE /MS interface arrangements. It is therefore recommended that the cross-sectional dimensions of the fused-silica and steel capillaries, and the gas streamlines, should be optimized when CE /MS interfaces are built. Moreover, the effect of gas flow on CE separation should be studied when optimizing the CE /MS operation parameters.  相似文献   

20.
The interface shape separating a gas layer within a superhydrophobic surface consisting of a square lattice of posts from a pressurized liquid above the surface is computed numerically. The interface shape is described by a constant mean curvature surface that satisfies the Young-Laplace equation with the three-phase gas-liquid-solid contact line assumed pinned at the post outer edge. The numerical method predicts the existence of constant mean curvature solutions from the planar, zero curvature solution up to a maximum curvature that is dependent on the post shape, size and pitch. An overall force balance between surface tension and pressure forces acting on the interface yields predictions for the maximum curvature that agree with the numerical simulations to within one percent for convex shapes such as circular and square posts, but significantly over predicts the maximum curvature for non-convex shapes such as a circular post with a sinusoidal surface perturbation. Changing the post shape to increase the contact line length, while maintaining constant post area, results in increases of 2 to 12% in the maximum computable curvature for contact line length increases of 11 to 77%. Comparisons are made to several experimental studies for interface shape and pressure stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号