首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
For the first time, an ion chromatographic method for the simultaneous determination of the disinfection by-products bromate, chlorite, chlorate, and the so-called seven standard anions, fluoride, chloride, nitrite, sulfate, bromide, nitrate and orthophosphate is presented. The separation of the ten anions was carried out using a laboratory-made high-capacity anion-exchanger. The high capacity anion-exchanger allowed the direct injection of large sample volumes without any sample pretreatment, even in the case of hard water samples. For quantification of fluoride, chloride, nitrite, sulfate, bromide, nitrate, orthophosphate and chlorate, a conductivity detection method was applied after chemical suppression. The post-column reaction, based on chlorpromazine, was optimized for the determination of chlorite and bromate. The method detection limit for bromate measured in deionized water is 100 ng/l and for chlorite, it is 700 ng/l. In hard drinking water, the method’s detection limits are 700 ng/l (bromate) and 3.5 μg/l (chlorite). The method’s detection limits for the other eight anions, determined by conductivity detection, are between 100 μg/l (nitrite) and 1.6 mg/l (chlorate).  相似文献   

2.
We describe a simple derivatization method to determine aldehydes. This method is based on derivatization with D-cysteine and consecutive liquid chromatography-tandem mass spectrometry (LC-MS/MS). The optimum derivatization conditions of aldehydes with D-cysteine were 10 min at 50°C and pH 7.0. The formed alkyl thiazolidine-4-carboxylic acid derivatives were directly injected in LC-MS/MS. In the established condition, the method was used to detect eight aldehydes in beverages. The limit of detection (LOD) and limit of quantification (LOQ) of the aldehydes were 0.2-1.9 μg L(-1) and 0.7-6.0 μg L(-1) and the relative standard deviation was less than 2.0% at concentrations of 0.1 mg L(-1) and 1.0 mg L(-1) with the exception of octanal. All the beverage samples had detectable levels of methanal (0.033-0.145 mg L(-1)), ethanal (0.085-2.12 mg L(-1)), propanal (ND to 0.250 mg L(-1)), butanal (ND to 0.003 mg L(-1)), pentanal (ND to 0.471 mg L(-1)), hexanal (ND to 0.805 mg L(-1)), heptanal (0.019-3.91 mg L(-1)) and octanal (0.029-0.118 mg L(-1)).  相似文献   

3.
建立了直接进样测定生活饮用水及其水源水中5种苯胺类化合物(苯胺、3-硝基苯胺、4-硝基苯胺、2,6-二氯-4-硝基苯胺和六硝基二苯胺)的液相色谱-串联质谱法。水样经0.22μm 聚醚砜滤膜过滤后直接进样,目标化合物在 HSS T3色谱柱上经梯度洗脱,于4 min 完成分离,多反应监测模式检测。5种苯胺类化合物在各自线性范围内线性良好,相关系数 R≥0.995。方法的检出限为0.773~1.88μg/ L(S/ N =3),定量限为2.58~6.27μg/ L(S/ N=10);峰面积的日内和日间相对标准偏差(RSD)分别为0.8%~1.9%和3.3%~4.9%;样品加标回收率为84.1%~105.0%,加标样品的 RSD 为1.0%~3.1%。应用本方法对35份水样进行了分析。结果表明,本方法准确、灵敏、快速,适用于生活饮用水及其水源水的常规分析,可为苯胺类化合物的污染评价提供技术支持。  相似文献   

4.
The use of capillary zone electrophoresis (CZE) on-line coupled with isotachophoresis (ITP) sample pretreatment (ITP-CZE) on a poly(methylmethacrylate) chip, provided with two separation channels in the column-coupling (CC) arrangement and on-column conductivity detection sensors, to the determination of bromate in drinking water was investigated. Hydrodynamic and electroosmotic flows of the solution in the separation compartment of the chip were suppressed and electrophoresis was a dominant transport process in the ITP-CZE separations. A high sample load capacity, linked with the use of ITP in this combination, made possible loading of the samples by a 9.2 microL sample injection channel of the chip. In addition, bromate was concentrated by a factor of 10(3) or more in the ITP stage of the separation and, therefore, its transfer to the CZE stage characterized negligible injection dispersion. This, along with a favorable electric conductivity of the carrier electrolyte solution, contributed to a 20 nmol/L (2.5 ppb) limit of detection for bromate in the CZE stage. Sample cleanup, integrated into the ITP stage, effectively complemented such a detection sensitivity and bromate could be quantified in drinking water matrices when its concentration was 80 nmol/L (10 ppb) or slightly less while the concentrations of anionic macroconstituent (chloride, sulfate, nitrate) in the loaded sample corresponding to a 2 mmol/L (70 ppm) concentration of chloride were still tolerable. The samples containing macroconstituents at higher concentrations required appropriate dilutions and, consequently, bromate in these samples could be directly determined only at proportionally higher concentrations.  相似文献   

5.
Bromate and nitrite are formed during the disinfection of water. The German threshold value for nitrite in drinking water is 100 μg/L, for bromate a limit below 50 μg/L has to be established. A self-made high-capacity resin with 2-(dimethylamino)-ethanol functionality in combination with a UV-transparent elution system based on perchloric acid allows the separation and sensitive photometric detection of nitrite and bromate, even if high chloride concentrations are present. The high capacity of the strongly basic resin allows sample volumes of up to 400 μL without disturbance of the separation. Detection limits for bromate and nitrite are 15 and 10 μg/L, respectively. The direct analysis of water samples with high salt contents, such as disinfected pool water, is possible by insertion of an on-line chloride removal step. Received: 30 September 1996 / Revised: 20 December 1996 / Accepted: 28 December 1996  相似文献   

6.
A speciation method utilizing ion chromatography coupled with inductively coupled plasma mass spectrometry is described for simultaneous analysis of eight halogenides and oxyhalogens: chloride, chlorite, chlorate, perchlorate, bromide, bromate, iodide and iodate. The method was applied for the analysis of drinking water samples collected from water treatment plants in areas in Finland, which are known to have high bromine concentrations in ground water. Water samples collected before and after disinfection were analyzed to get information about potential species conversion as a result of purification. Chloride and chlorate were the chlorine species found in these water samples, and iodine existed as both iodate and iodide. In the case of bromine, species conversion had taken place, since total bromine concentrations were increased during disinfection but bromide concentrations were decreased. No bromate was observed in the samples. The detection limits for all the chlorine species studied were 500 μg/l, for bromine species studied 10 μg/l, for iodide 0.1 μg/l and for iodate 0.2 μg/l.  相似文献   

7.
A simple sample preconcentration technique employing microwave-based evaporation for the determination of trace level bromate and perchlorate in drinking water with ion chromatography is presented. With a hydrophilic anion-exchange column and a sodium hydroxide eluent in linear gradient, bromate and perchlorate can be determined in one injection within 35 min. Prior to ion chromatographic analysis, the drinking water sample was treated with an OnGuard-Ag cartridge to remove the superfluous chloride and concentrated 20-fold using a PTFE beaker in a domestic microwave oven for 15 min.The recoveries of the anions ranged from 94.6% for NO2- to 105.2% for F-. The detection limits for bromate, perchlorate, iodate and chlorate were 0.1, 0.2, 0.1 and 0.2 microg/l, respectively. The developed method is applicable for the quantitation of bromate and perchlorate in drinking water samples.  相似文献   

8.
建立离子色谱法测定饮用和地下水中F-、BrO3-、Cl-、NO2、NO3和SO42- 6种阴离子.选用IonPac(R)AS19色谱柱(4 mm×250 mm),NaOH梯度淋洗,抑制电导检测,方法检出限为0.01~0.02 mg/L.对水样进行6次平行测定,测定结果的相对标准偏差为1.1%~2.1%,加标回收率为71...  相似文献   

9.
Bromate is a byproduct formed as a result of disinfection of bromide-containing source water with ozone or hypochlorite. The International Agency for Research on Cancer has recognized bromate as a possible human carcinogen, thus it is essential to determine in drinking water. Present work highlights a development of sensitive and fast analytical method for bromate determination in drinking water by using ultraperformance liquid chromatography-tandem mass spectrometry. The quality parameters of the developed method were established, obtaining very low limit of detection (0.01 ng/mL), repeatability and reproducibility have been found to be less than 3% in terms of relative standard deviation when analyzing a bromate standard at 0.05 μg/mL with 0.4 min analysis time. Developed method was applied for the analysis of metropolitan and bottled water from Saudi Arabia; 22 samples have been analyzed. Bromate was detected in the metropolitan water samples (from desalinization source) at concentrations ranging between 3.43 and 75.04 ng/mL and in the bottled water samples at concentrations ranging between 2.07 and 21.90 ng/mL. Moreover, in comparison to established analytical methods such as liquid chromatography-tandem mass spectrometry, the proposed method was found to be very sensitive, selective and rapid for the routine analysis of bromate at low level in drinking water.  相似文献   

10.
The on-line-coupling of ion chromatography (IC) and inductively coupled plasma mass spectrometry (ICP-MS) is a powerful tool for the determination of bromate in drinking waters. The use of a high-capacity and high-performance anion-exchanger combined with an NH4NO3-based elution system allows the determination of bromate in almost every water sample without any sample pretreatment. The method detection limits in the water samples investigated are 50 to 65 ng/L or 44 to 58 pg bromate, respectively. Considering sensivity as well as imprecision (5% at 500 ng/L bromate) and short analysis times (8 to 15 min per sample including sample uptake), the described IC-ICP-MS coupling is well suited for precise routine analyses of bromate in drinking waters at the sub μg/L level.  相似文献   

11.
建立一种检测饮用水中痕量溴酸盐的离子色谱方法。利用On GuardⅡAg柱过滤去除水中氯离子,直接进样,电导检测器检测。该方法避免了氯离子对溴酸盐的干扰,测定水质溴酸盐的灵敏度和准确度均有很大提高。溴酸盐的检出限为0.005 mg/L,测定结果的相对标准偏差为7.56%(n=7),加标回收率为92.0%~110.0%。该方法操作简便快速、准确度高,适合于饮用水中痕量溴酸盐的测定。  相似文献   

12.
李鹏飞  王燕  张征  童卫杭  吴华  马萍  王静  刘丽宏 《分析化学》2012,40(10):1573-1578
建立高效液相色谱-质谱联用法同时测定人血浆中免疫抑制剂及合并用药12种药物浓度的方法.选用Kromasil-C18色谱柱(50 mm× 4.6 mm×5 μm),以甲醇-乙腈-1mmol/L乙酸铵溶液为流动相,采用梯度洗脱进行分离,样本用甲醇沉淀蛋白后进样,流速:1.1 mL/min;柱温:35℃;进样量:20μL.选用3200QTrap型液相色谱-串联质谱仪的多反应监测(MRM)扫描方式进行检测.12种药物的线性范围为0.2~1000μg/L;定量下限为0.2 μg/L.准确度与精密度结果显示方法日间、日内RSD均小于15%;相对偏差-13%~9.33%,稳定性较好.本方法快速、灵敏,专属性强、重现性好,可用于人体血浆中免疫抑制剂及其常用合并用药共12种药物浓度的测定.  相似文献   

13.
The influence of natural organic matter on the screening of pharmaceuticals in water was determined by using high resolution liquid chromatography (HRLC) combined with full scan mass spectrometry (MS) techniques like time of flight (ToF) or Orbitrap MS. Water samples containing different amount of natural organic matter (NOM) and residues of a set of 11 pharmaceuticals were analyzed by using Exactive Orbitrap? LC-MS. The samples were screened for residues of pharmaceuticals belonging to different classes like benzimidazoles, macrolides, penicillins, quinolones, sulfonamides, tetracyclines, tranquillizers, non-steroidal anti-inflammatory drugs (NSAIDs), anti-epileptics and lipid regulators. The method characteristics were established over a concentration range of 0.1-500 μg L(-1). The 11 pharmaceuticals were added to two effluent and two influent water samples. The NOM concentration within the samples ranged from 2 to 8 mg L(-1) of dissolved organic carbon. The HRLC-Exactive Orbitrap? LC-MS system was set at a resolution of 50,000 (FWHM) and this selection was found sufficient for the detection of the list of pharmaceuticals. With this resolution setting, accurate mass measurements with errors below 2 ppm were found, despite of the NOM concentration of the different types of water samples. The linearities were acceptable with correlation coefficients greater than 0.95 for 30 of the 51 measured linearities. The limit of detection varies between 0.1 μg L(-1)and 100 μg L(-1). It was demonstrated that sensitivity could be affected by matrix constituents in both directions of signal reduction or enhancement. Finally it was concluded that with direct shoot method used (no sample pretreatment) all compounds, were detected but LODs depend on matrix-analyte-concentration combination. No direct relation was observed between NOM concentration and method characteristics. For accurate quantification the use of internal standards and/or sample clean-up is necessary. The direct shoot method is only applicable for qualitative screening purposes. The use of full scan MS makes it possible to search for unknown contaminants. With the use of adequate software and a database containing more than 50,000 entries a tool is available to search for unknowns.  相似文献   

14.
A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 μg/L and the limit of quantitation (LOQ) was 0.1 μg/L. Water matrix effects of ionic strength, dissolved organic carbon (DOC) and pH were examined. The results indicate that signal detection intensity for MC-LR was significantly suppressed as the ionic strength increased from ultrapure water condition, whereas it increased slightly with solution pH and DOC at low concentrations. However, addition of methanol (MeOH) into the sample was able to counter the signal suppression effects. In this study, dilution of the tap water sample by adding 4% MeOH (v/v) was observed to be adequate to compensate for the signal suppression. The recoveries of the samples fortified with MC-LR (0.2, 1, and 10 μg/L) for three different tap water samples ranged from 84.4% to 112.9%.  相似文献   

15.
微波浓缩-离子法测定饮用水中的痕量溴酸根和高氯酸根   总被引:26,自引:0,他引:26  
刘勇建  牟世芬  杜兵  林爱武 《色谱》2002,20(2):129-132
 建立了一种简便的用于浓缩水中痕量BrO3 -和ClO4 -的样品前处理方法。水样经OnGuardAg柱过滤 ,用微波炉在 15min内可浓缩 2 0倍 ,所测离子的回收率均高于 90 %。又采用IonPacAS16型亲水性柱 ,用 15 0 μL定量环 ,以NaOH为流动相、梯度淋洗方式 ,在 35min内测定了包括BrO3 -和ClO4 -在内的 8种离子。BrO3 -和ClO4 -的检测限分别为 0 10 μg/L和 0 2 0 μg/L。该方法在实际应用中有较大的参考价值。  相似文献   

16.
Li S  Wang X  Peng K  Ma Z  Zhang X  Fu S  Li X  Li L  Hong A  Jiang J 《Molecules (Basel, Switzerland)》2012,17(3):2663-2674
A rapid LC-MS/MS method with good accuracy and sensitivity was developed and validated for the pharmacokinetics study of metoprolol (MP) in beagle dogs. The plasma samples were simply precipitated by methanol and then analyzed by LC-MS/MS. An Ultimate XB-C?? column (150 × 2.1 mm ID, 5 μm) was used for separation, with methanol-water containing 0.2% formic acid (65:35, v/v) as the mobile phase at a flow rate of 0.2 mL/min. Monitoring ions of MP and internal standard (hydroxypioglitazone) were m/z 268.1/115.6 and m/z 373.1/150.2, respectively. The linear range was 3.03-416.35 ng/mL with an average correlation coefficient of 0.9996, and the limit of quantification was 3.03 ng/mL. The intra- and inter-day precision was less than 15%. At low, middle and high concentrations, the recovery, the matrix effect and the accuracy was in the range of 76.06%-95.25%, 93.67%-104.19% and 95.20%-99.96% respectively. The method was applied for the pharmacokinetics study of MP tartrate tablets (50 mg). The AUC(0-t), T(max) and C(max) were respectively 919.88 ± 195.67 μg/L·h, 0.96 ± 0.33 h, 349.12 ± 78.04 ng/mL.  相似文献   

17.
 Two different mass spectrometric methods, negative thermal ionization isotope dilution mass spectrometry (NTI-IDMS) and inductively coupled plasma mass spectrometry (ICP-MS), off-line and on-line coupled with anion exchange chromatography, have been developed for simultaneous bromide and bromate determinations in water samples. The detection limits of these methods are in the range of 0.03–0.09 μg/L using a 50 mL sample.The results are independent of the content of other anions, which could be demonstrated by the analyses of six mineral waters containing chloride and sulfate of up to 160 mg/L and 1500 mg/L, respectively. Bromide has been analyzed by the NTI-IDMS method in the range of 10–500 μg/L and bromate in the range of 1–50 μg/L with relative standard deviations of 0.3–1.2% and 0.4–6%. Quantification for the ICP-MS method was carried out by the standard addition technique, which resulted in relative standard deviations of 5.5% for bromide at the 500 μg/L level and of 13% for bromate at the level of about 3 μg/L. These results are compared with those described in the literature for ion chromatographic (IC) and other methods and those obtained in this work by IC using UV detection, which allows high concentrations of chloride in the bromate fraction. The detection limits of this IC method are 6 μg/L for bromide and 30 μg/L for bromate. NTI-IDMS and ICP-MS therefore fit the recommendations of the European Union (detection limit<2.5 μg/L; precision and accuracy better than 25% at the 10 μg/L level) for methods analyzing the carcinogenic bromate much better than IC and other methods applied up to now. As a definitive but time consuming method, NTI-IDMS is preferably applicable as a calibration technique, whereas ICP-MS, with relatively short analysis times, due to on-line coupling with chromatography, can be used as a sensitive and powerful routine method for trace bromide and bromate species in water samples. Received: 5 July 1996/Accepted: 7 August 1996  相似文献   

18.
 Two different mass spectrometric methods, negative thermal ionization isotope dilution mass spectrometry (NTI-IDMS) and inductively coupled plasma mass spectrometry (ICP-MS), off-line and on-line coupled with anion exchange chromatography, have been developed for simultaneous bromide and bromate determinations in water samples. The detection limits of these methods are in the range of 0.03–0.09 μg/L using a 50 mL sample.The results are independent of the content of other anions, which could be demonstrated by the analyses of six mineral waters containing chloride and sulfate of up to 160 mg/L and 1500 mg/L, respectively. Bromide has been analyzed by the NTI-IDMS method in the range of 10–500 μg/L and bromate in the range of 1–50 μg/L with relative standard deviations of 0.3–1.2% and 0.4–6%. Quantification for the ICP-MS method was carried out by the standard addition technique, which resulted in relative standard deviations of 5.5% for bromide at the 500 μg/L level and of 13% for bromate at the level of about 3 μg/L. These results are compared with those described in the literature for ion chromatographic (IC) and other methods and those obtained in this work by IC using UV detection, which allows high concentrations of chloride in the bromate fraction. The detection limits of this IC method are 6 μg/L for bromide and 30 μg/L for bromate. NTI-IDMS and ICP-MS therefore fit the recommendations of the European Union (detection limit<2.5 μg/L; precision and accuracy better than 25% at the 10 μg/L level) for methods analyzing the carcinogenic bromate much better than IC and other methods applied up to now. As a definitive but time consuming method, NTI-IDMS is preferably applicable as a calibration technique, whereas ICP-MS, with relatively short analysis times, due to on-line coupling with chromatography, can be used as a sensitive and powerful routine method for trace bromide and bromate species in water samples. Received: 5 July 1996/Accepted: 7 August 1996  相似文献   

19.
Dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry-selective ion monitoring (GC-MS-SIM) was applied to the determination of methyl tert-butyl ether (MTBE) in water samples. The effect of main parameters affecting the extraction efficiency was studied simultaneously. From selected parameters, volume of extraction solvent, volume of dispersive solvent, and salt concentration were optimized by means of experimental design. The statistical parameters of the derived model were R(2)=0.9987 and F=17.83. The optimal conditions were 42.0 μL for extraction solvent, 0.30 mL for disperser solvent and 5% (w/v) for sodium chloride. The calibration linear range was 0.001-370 μg L(-1). The improved detection limit with the aid of chemometrics was 0.3 ng L(-1). The relative standard deviation (RSD) with n=9 for 0.1 mg L(-1) MTBE in water with and without internal standard was 2.7% and 3.1%, respectively. Under the optimal conditions, the relative recoveries of spiked MTBE in different water samples were in the range of 100-105%.  相似文献   

20.
para-Chlorobenzoic acid (p-CBA) is typically used as a probe compound to indirectly quantify hydroxyl radicals formed during advanced oxidation processes used in drinking water and wastewater treatment. A method has been developed for the sensitive analysis of p-CBA in water using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A reporting limit in water of 100 ng/L was determined for the method, which is 40-fold lower than the 4.0 microg/L reporting limit of the widely used liquid chromatography with UV detection (LC-UV) method. The method was found to be robust in difficult matrices such as wastewater and highly selective, unlike LC-UV which relies on non-specific detection at 234 nm. The detection of p-CBA below 1 microg/L during bench-scale ozonation of wastewater after hydrogen peroxide addition was demonstrated. Duplicate samples were analyzed by LC-MS/MS and LC-UV and results were found to be comparable at concentrations quantifiable by both methods.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号