首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A method with parallel extraction columns and parallel analytical columns (PEC-PAC) for on-line high-flow liquid chromatography/tandem mass spectrometry (LC/MS/MS) was developed and validated for simultaneous quantification of a drug candidate and its six metabolites in dog plasma. Two on-line extraction columns were used in parallel for sample extraction and two analytical columns were used in parallel for separation and analysis. The plasma samples, after addition of an internal standard solution, were directly injected onto the PEC-PAC system for purification and analysis. This method allowed the use of one of the extraction columns for analyte purification while the other was being equilibrated. Similarly, one of the analytical columns was employed to separate the analytes while the other was undergoing equilibration. Therefore, the time needed for re-conditioning both extraction and analytical columns was not added to the total analysis time, which resulted in a shorter run time and higher throughput. Moreover, the on-line column extraction LC/MS/MS method made it possible to extract and analyze all seven analytes simultaneously with good precision and accuracy despite their chemical class diversity that included primary, secondary and tertiary amines, an alcohol, an aldehyde and a carboxylic acid. The method was validated with the standard curve ranging from 5.00 to 5000 ng/mL. The intra- and inter-day precision was no more than 8% CV and the assay accuracy was between 95 and 107%.  相似文献   

2.
In recent years, two-dimensional liquid chromatography (2D-LC) has been used increasingly for the analysis of synthetic polymers. A 2D-LC analysis provides richer information than a single chromatography analysis at the cost of longer analysis time. The time required for a comprehensive 2D-LC analysis is essentially proportional to the analysis time of the second dimension separation. Many of 2D-LC analyses of synthetic polymers have employed size exclusion chromatography (SEC) for the second-dimension analysis due to the relatively short analysis time in addition to the wide use in the polymer analysis. Nonetheless, short SEC columns are often used for 2D-LC analyses to reduce the separation time, which inevitably deteriorates the resolution. In this study, we demonstrated that high temperature SEC can be employed as an efficient second-LC in the 2D-LC separation of synthetic polymers. By virtue of high temperature operation (low solvent viscosity and high diffusivity of the polymer molecules), a normal length SEC column can be used at high flow rate with little loss in resolution.  相似文献   

3.
A rapid and selective HPLC method using monolithic columns was developed for the separation and quantification of the principal amphetamines in ecstasy tablets. Three monolithic (Chromolith RP18e) columns of different lengths (25, 50 and 100 mm) were assessed. Validation studies including linearity, selectivity, precision, accuracy and limit of detection and quantification were carried out using the Chromolith SpeedROD, RP-18e, 50 mm x 4.6 mm column. Column backpressure and van Deemter plots demonstrated that monolithic columns provide higher efficiency at higher flow rates when compared to particulate columns without the loss of peak resolution. Application of the monolithic column to a large number of ecstasy tablets seized in Ireland ensured its suitability for the routine analysis of ecstasy tablets.  相似文献   

4.
We attempted to establish a high‐speed and high‐resolution profiling method for a carotenoid mixture as a highly selective and highly sensitive detection method; the analysis was carried out by supercritical fluid chromatography (SFC) coupled with mass spectrometry (MS). When an octadecyl‐bonded silica (ODS) particle‐packed column was used for separation, seven carotenoids including structural isomers were successfully separated within 15 min. This result indicated not only improved separation but also improved throughput compared to the separation and throughput in RP‐HPLC. The use of a monolithic ODS column resulted in additional improvement in both the resolution and the throughput; the analysis time was reduced to 4 min by increasing the flow rate. Furthermore, carotenoids in biological samples containing the complex matrices were separated effectively by using several monolithic columns whose back pressure was very low. The mass spectrometer allowed us to perform a more sensitive analysis than UV detection; the detection limit of each carotenoid was 50 pg or below. This is the first report of carotenoid analysis carried out by SFC‐MS. The profiling method developed in this study will be a powerful tool for carrying out accurate profiling of biological samples.  相似文献   

5.
In size-exclusion chromatography (SEC), proteins and peptides are separated according to their molecular size in solution. SEC is especially useful as an effective fractionation step to separate a vast amount of impurities from the components of interest and/or as final step for the separation of purified proteins from their aggregates, in a so-called polishing step. However, the throughput in SEC is low compared to other chromatographic processes as good resolution can be achieved only with a limited feed volume (i.e., maximal approximately 5% of the column volume can be loaded). This limitation opposed widespread application of conventional SEC in industry despite its excellent separation potential. Therefore a continuous separation process (namely preparative continuous annular chromatography) was developed and compared to a conventional SEC system both using Superdex 200 prep grade as sorbent. An immunoglobulin G sample with a high content of aggregates was chosen as a model protein solution. The influence of the feed flow-rate, eluent flow-rate and rotation rate on the separation efficiency was investigated. The height equivalent to a theoretical plate was lower for preparative continuous annular chromatography which could be explained by reduced extra column band broadening. The packing quality was proved to be identical for both systems. The productivity of conventional batch SEC was lower compared to continuous SEC, consequently buffer consumption was higher in batch mode.  相似文献   

6.
Columns switch recycling size exclusion chromatography (csrSEC) was proposed to achieve high resolution protein separation with good biocompatibility. Proteins were firstly separated by two serially coupled SEC columns, and fractions were in sequence switched back to the first column by two-position valves for further separation in terms of close-loop recycling until satisfactory resolution was achieved. Compared to SEC, the separation window was broadened by increasing column length via cycling without further increase on back pressure. Compared to recycling SEC (rSEC), the overtaking of later eluted components by early eluted ones after several cycles could be avoided for complex sample analysis, by parking fractions in the second SEC column before transferred in turn back to the first one for cycling ordinally. In our experiments, the baseline separation of five proteins with molecular weight ranging from 10 kDa to 80 kDa was achieved by csrSEC. Furthermore, a multidimensional csrSEC–RPLC platform was constructed, and peak capacity up to 3600 was obtained for protein separation. All these results demonstrated that csrSEC is a promising protein separation mode with good biocompatibility, broadened separation window and improved resolution.  相似文献   

7.
Liquid chromatography of polymers is traditionally a slow technique with analysis times of typically 30 min per sample. For the application of liquid chromatographic techniques to combinatorial materials research the analysis time per sample must be reduced considerably. Analysis time in SEC can be reduced to about 2 min per sample when high‐throughput columns are used. For HPLC small columns with improved separation efficiencies can be used. As compared to conventional technology, time savings of more than 80% are achieved.

Chromatogram from conventional SEC column compared to high‐speed SEC column tested on an identical instrument with polystyrene standards in THF.  相似文献   


8.
The reduction of analysis time, cost, and improvement of separation efficiency are the main requirements in the development of high‐throughput assay methods in bioanalysis. It can be achieved either by ultra‐high‐performance liquid chromatography (UHPLC) using stationary phases with small particles (<2 μm) at high back pressures or by using opposite direction—monolithic stationary phases with low back pressures. The application of new types of monolithic stationary phases for UHPLC is a novel idea combining these two different paths. The aim of this work was to test the recently introduced second‐generation of monolithic column Chromolith® HighResolution for UHPLC analysis of liposoluble vitamins in comparison with core‐shell and fully porous sub‐2 μm columns with different particle sizes, column lengths, and shapes. The separation efficiency, peak shape, resolution, time of analysis, consumption of mobile phase, and lifetime of columns were calculated and compared. The main purpose of the study was to find a new, not only economical option of separation of liposoluble vitamins for routine practice.  相似文献   

9.
The potential of high-speed analyses by rapid resolution liquid chromatography (RRLC) and RRLC/MS on 1.8-microm porous particles packed into short columns operated at high flow-rate was investigated and compared with the performance of 5-microm porous particles packed into conventional columns. Using similar chemistries, the ease of conversion from conventional HPLC to an RRLC method was demonstrated. In order to display the practicality of RRLC separations, the analysis of pesticides in crops and catechins in Japanese green tea was selected. Using the Japanese Food Hygiene Law method, which employs a conventional 5-microm RP column (250 mm x 4.6 mm) for quantification of pesticides in crops, the analysis time was 25 min under isocratic conditions. Using the RRLC method on the short (50 mm x 4.6 mm) column packed with 1.8-microm porous particles, the same separation could be performed in 0.8 min with the RRLC/MS method without a loss in resolution. At the highest flow rate, compared to the conventional method, the time could be reduced by a factor of 31. In gradient elution, the fastest separation of catechins in Japanese green tea was achieved by RRLC on 50-mm x 4.6-mm id or 50-mm x 2.1-mm id RRLC columns packed with 1.8-microm particles. The analysis time at 5 mL/min was less than 1 min. Compared to the conventional HPLC method on a 150-mm column packed with 5-microm particles, time was reduced by a factor of 15. The effect of other experimental parameters such as the column temperature, acquisition rate of the detector and the influence of cell volume on chromatographic performance was also investigated. After the optimization, the analysis precision under the fastest RRLC conditions was examined. RSDs of retention time and peak area were 0.2% and 0.47%, respectively.  相似文献   

10.
Method qualification is a key step in the development of routine analytical monitoring of pharmaceutical products. However, when relying on published monographs that describe longer method times based on older high‐performance liquid chromatography column and instrument technology, this can delay the overall analysis process for generated drug products. In this study, high‐throughput ultrahigh pressure liquid chromatography techniques were implemented to decrease the amount of time needed to complete a 24‐run sequence to identify linearity, recovery, and repeatability for both drug assay and impurity analysis in 16 min. Multiple experimental parameters were tested to identify a range of experimental settings that could be used for the sequence while still maintaining this fast analysis time. The full sequence was replicated on a different system and with different columns, further demonstrating its robustness.  相似文献   

11.
As a continuation of our efforts to improve our high-flow on-line bioanalytical approach for high-throughput quantitation of drugs and metabolites in biological matrices by high-performance liquid chromatography (LC) and tandem mass spectrometry (MS/MS), we have developed a ternary-column on-line LC/MS/MS system with dual extraction columns used in parallel for purification and an analytical column for analysis. The advantage of the dual extraction column system is that sample analysis can take place in one of the extraction columns while the other column is being equilibrated. Thus, the equilibration time does not add to the run time, hence shortening the injection cycle time and increasing the sample throughput. Moreover, the use of two extraction columns in parallel increases the number of samples that can be injected before the system fails due to an overused extraction column. Such a system has successfully been used to develop and validate a positive ion electrospray LC/MS/MS bioanalytical method for the quantitative determination of a guanidine-containing drug candidate in rat plasma. The system used for this work utilized two Oasis HLB extraction columns (1 x 50 mm, 30 microm), one C18 analytical column (3.9 x 50 mm, 5 microm), a ten-port switching value and a tandem mass spectrometer. The on-line analysis was accomplished by the direct injection of 10 microL of the sample, obtained by mixing a rat plasma sample 1:1 with an aqueous internal standard solution. Selected reaction monitoring (SRM) was utilized for the detection of the analyte and internal standard. The standard curve range was 1.00-200 ng/mL. The intra- and inter-day precision and accuracy were within 6.6%. The on-line purification step lasted for only 0.3 min and total run time was only 1.6 min.  相似文献   

12.
Deficiencies of galactosylceramidase and glucocerebrosidase result in the accumulation of galactosylsphingosine (GalSph) and glucosylsphingosine (GluSph) in Krabbe and Gaucher diseases, respectively. GalSph and GluSph are useful biomarkers for both diagnosis and monitoring of treatment effects. We have developed and validated a sensitive, accurate, high‐throughput assay for simultaneous determination of the concentration of GalSph and GluSph in mouse serum. GalSph and GluSph and their deuterated internal standards were extracted by protein precipitation in quantitative recoveries, baseline separated by hydrophilic interaction chromatography and detected by positive‐ion electrospray mass spectrometry in multiple reaction monitoring mode. Total run time was 7 min. The lower limit of quantification was 0.2 ng/mL for both GalSph and GluSph. Sample stability, assay precision and accuracy, and method robustness were demonstrated. This method has been successfully applied to measurement of these lipid biomarkers in a natural history study in twitcher (Krabbe) mice.  相似文献   

13.
The use of sub-2-microm particle columns for fast high throughput metabolite ID applications was investigated. Three LC-MS methods based on different sub-2-microm particle size columns using the same analytical 3 min gradient were developed (Methods A, B, and C). Method A was comprised of a 1.8 microm particle column coupled to an MS, methods B and C utilized a 1.7 microm particle column (BEH 50 x 2.1 mm2 id) and 1.8 microm particle column coupled to a Q-TOF MS. The precision and the separation efficiency of the methods was compared with repeated standard injections (N=10) of reference compounds verapamil (VP), propranolol, and fluoxetine. Separation efficiency and MS/MS spectral quality were also evaluated for separation and detection of VP and its two major metabolites norverapamil (NVP) and O-demethylverapamil (ODMVP) in human-liver microsomal incubates. Results show that 1.8 microm particle columns show similar performance for separation of VP and its major metabolites and comparable spectral quality in MS(E) mode of the Q-TOF instrument compared to 1.7 microm particle columns. Additionally, the study also confirmed that sub-2-microm particle size columns can be operated with standard analytical HPLC but that performance is maximized by integrating column in UPLC method with reduced void volumes. All the methods are suitable for the determination of major metabolites for compounds with high metabolic turnover. The high throughput metabolite profile analysis using 384-well plate format of up to 48 compounds in incubates of human-liver microsomes was discussed.  相似文献   

14.
We report on the size-exclusion chromatography (SEC) operated at high column temperature to reduce the analysis time. The column temperature was raised beyond the normal boiling point of the eluent and a sufficient column backpressure was applied to prevent the mobile phase from boiling by inserting a narrow bore tubing between the separation column and the detector. The narrow bore tubing also functions to cool the effluent down to the room temperature before it reaches the detector. Therefore, normal SEC detectors can be used without any modification. It was confirmed that the SEC analysis time could be shortened significantly by the high-temperature operation without serious deterioration in the resolution.  相似文献   

15.
An HPLC method has been developed for the fast separation and quantification of permethrin using C18 column packed with 1.8 μm particles. The method is specific with good resolution to degradation products and to other present components. It has acceptable validation results. The run time is 4.5 min (or may be within 1.6 min is rapid resolution mode) with an organic solvent consumption of 3.6 mL per run. The method has been applied to samples of formulations for various uses: mattress cleaner, shampoo, and veterinary powder. The performance of the applied column is compared with other common column types. The relationships between linear velocity of the mobile phase (u) and resolution factor (Rs), back-pressure (ΔP), and efficiency (H) are presented. The experimental data shows the advantages of 1.8-μm particle columns to be a significant reduction in solvent consumption (by factor of 4.4 and 1.5) and a reduction in run-time (by factor 4.7 and 1.5), and the weaknesses are a high back-pressure and lower efficiency. Finally, it has been shown that use of 1.8-μm particle packed columns with conventional HPLC systems is possible, but with limitations in mobile phase flow-rate.  相似文献   

16.
Although linear salt gradient elution ion-exchange chromatography (IEC) of proteins is commonly carried out with relatively short columns, it is still not clear how the column length affects the separation performance and the economics of the process. The separation performance can be adjusted by changing a combination of the column length, the gradient slope and the flow velocity. The same resolution can be obtained with a given column length with different combinations of the gradient slope and the flow velocity. This results in different separation time and elution volume at the same resolution. Based on our previous model, a method for determining the separation time and the elution volume relationship for the same resolution (iso-resolution curve) was developed. The effect of the column length and the mass transfer rate on the iso-resolution curve was examined. A long column and/or high mass transfer rate results in lesser elution volume. The resolution data with porous bead packed columns and monolithic columns were in good agreement with the calculated iso-resolution curves. Although the elution volume can be reduced with increasing column length, the pressure drop limits govern the optimum conditions.  相似文献   

17.
A fast and sensitive ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method was developed for the determination of lovastatin in human plasma. With simvastatin as internal standard, sample pretreatment involved one-step extraction with n-hexane-methylene dichloride-isopropanol (20:10:1, v/v/v) of 0.5 mL plasma. Chromatographic separation was carried out on an Acquity UPLC BEH C(18) column with mobile phase consisting of acetonitrile-water (containing 5 mmol/L ammonium acetate; 85:15, v/v) at a flow-rate of 0.35 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) via electrospray ionization source with positive mode. The analysis time was shorter than 1.7 min per sample. The standard curve was linear (r2>or=0.99) over the concentration range 0.025-50.0 ng/mL with a lower limit of quantification of 0.025 ng/mL. The intra- and inter-day precision values were below 11% and the accuracy (relative error) was within 6.0% at three quality control levels. This is the first method of MS with MRM coupled to UPLC for the determination of lovastatin, which showed great advantages of high sensitivity, selectivity and high sample throughput. It was fully validated and successfully applied to the pharmacokinetic study of lovastatin tablets in healthy Chinese male volunteers after oral administration.  相似文献   

18.
Covadonga Alvarez 《Talanta》2009,79(2):280-283
A sensitive and specific and automated liquid chromatography-electrospray mass spectrometric (LC-ESI-MS) assay for the quantification of Cyclosporin A in human plasma was developed. Following a simple protein precipitation step, the supernatant was extracted on-line and directly injected into the system LC-ESI-MS. A relatively new type of monolithic column consisting of a silica rod with bimodal pore structure was used to achieve a retention time of 2.4 min with a very low backpressure at a flow rate of 1 ml/min. The assay was linear from 0.050 to 1.000 μg/ml. The mean recovery was 91%. The mean inter-day and intra-day precisions were 1.85% and 2.83%, respectively. The combination of the automated solid phase extraction and the low retention time achieved with this columns increase the throughput and decrease the time of analysis of each sample. This technology is useful in order to improve the efficiency of the bioanalytical studies.  相似文献   

19.
Band broadening in size-exclusion chromatography of polydisperse samples   总被引:1,自引:0,他引:1  
Understanding and controlling the band broadening is essential to obtain accurate molar-mass distributions by size-exclusion chromatography (SEC). In this paper, band broadening in SEC is reviewed from a contemporary perspective. The observed band broadening is due to dispersion inside and outside the chromatographic column (undesirable band broadening) and to the polydispersity of the sample (desirable SEC selectivity). The various contributors to band broadening are discussed. Integrity plots are introduced as a tool to evaluate the performance of specific SEC columns at given experimental conditions. For narrow polymer standards on single SEC columns the observed peak width is dominated by the chromatographic dispersion. MALDI-ToF-MS is demonstrated as an alternative to determine the PDI of narrowly distributed samples. The plate heights encountered at very high reduced velocities are found to be lower than expected. This is advantageous for fast separations by SEC.  相似文献   

20.
The principal secondary flavour compounds in distilled spirits can be successfully quantified by split injection to a 0.15 mm internal diameter (I.D.) capillary column. Initial conditions for split ratio, gas velocity, initial oven temperature and oven ramp rate are given by method translation from a similar method on a standard 0.25 mm internal diameter column with the same phase. These parameters were then investigated in an experimental design comprising a series of experiments in which the responses were the resolution of two critical peak pairs, the analysis time and the limit of quantification (LOQ) of the eight major compounds. The LOQ is the concentration corresponding to a signal 10 times greater than the noise. The experiments were replicated at two different concentration levels, which encompassed the natural levels of the compounds of interest found in distilled spirits. From the chemometric evaluation of these data, a validated model was constructed, which allowed the prediction of conditions for optimum chromatographic analysis. Three additional concentration levels were then added to the model to establish linearity, repeatability and sensitivity. Modern gas chromatographic hardware allows the use of these narrow-bore capillary columns for routine use without operational difficulties. Major advantages are a substantial decrease in analysis time allowing high throughput processing of samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号