首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 23 毫秒
1.
High resolution three-dimensional space charge cartographies obtained on 50 μm PTFE samples by using FLIMM technique are presented in this article. Samples were irradiated by a 30 keV electron beam. Charges were injected according to the grid pattern put on the sample during irradiation. A new measurement strategy associated with a new set-up leads to an improvement in measurements accuracy and precision. With this new strategy, measurements were performed rapidly, at a chosen depth and with a low lateral resolution in order to map the space charge profile in the whole sample and to choose a study area. After selecting an interesting area, space charge cartographies were carried out with a very high lateral resolution of about 1 μm. The irradiated zones according to the grid pattern were well reconstructed and the injection depth did not exceed 4 μm.  相似文献   

2.
Copper particles were electrolessly deposited on a palladium aerosol activated polymer membrane in the presence of ultrasound. An application of ultrasound introduced a faster deposition (220 μg min?1 in deposition rate) and finer copper particles (9 nm in crystallite size) than those (11 and 41 μg min?1; 27 and 32 nm) in the absence of ultrasound (i.e. respectively 20 and 45 °C in bath temperature with mechanical agitation). A better performance of methanol steam reforming (0.59 in mean conversion during 5 h operation; 1.3 and 1.6 times respectively higher than those from 20 to 45 °C cases) at a 300 °C reaction temperature was materialized for the ultrasound application, probably due to a finer (i.e. a more textured) copper particle deposition on a polymer membrane.  相似文献   

3.
The chromatic confocal microscopy is an effective method for displacement measurement. However, with relatively low detection efficiency, chromatic confocal systems from previous studies suffer from either a limited measuring range or an unsatisfying resolution. In this paper, a novel chromatic confocal system is proposed based on optical fiber with large diameter that is specifically chosen to allow more light to be detected, thus greatly improving the detection efficiency of the system. To accurately locate the peak wavelength of the recorded spectrum, four data processing methods are proposed and compared, within which the Gaussian fitting model is considered best for the system. A series of experiments are done to verify the feasibility, resolution and stability of the system. An applicable measuring range of 600 μm is discovered with a highly linear range of 400 μm. The system has a high resolution close to 0.10 μm with satisfying stability shown by a long-term displacement standard deviation of 0.16 μm.  相似文献   

4.
ObjectivesWe validate a 4D strategy tailored for 3 T clinical systems to simultaneously quantify function and infarct size in wild type mice after ischemia/reperfusion, with improved spatial and temporal resolution by comparison to previous published protocols using clinical field MRI systems.MethodsC57BL/6J mice underwent 60 min ischemia/reperfusion (n = 14) or were controls without surgery (n = 6). Twenty-four hours after surgery mice were imaged with gadolinium injection and sacrificed for post-mortem MRI and histology with serum also taken for Troponin I levels. The double ECG- and respiratory-triggered 3D FLASH (Fast Low Angle Shot) gradient echo (GRE) cine sequence had an acquired isotropic resolution of 344 μm, TR/TE of 7.8/2.9 ms and acquisition time 25–35 min. The conventional 2D FLASH cine sequence had the same in-plane resolution of 344 μm, 1 mm slice thickness and TR/TE 11/5.4 ms for an acquisition time of 20–25 min plus 5 min for planning. Left ventricle (LV) and right ventricle (RV) volumes were measured and functional parameters compared 2D to 3D, left to right and for inter and intra observer reproducibility. MRI infarct volume was compared to histology.ResultsFor the function evaluation, the 3D cine outperformed 2D cine for spatial and temporal resolution. Protocol time for the two methods was equivalent (25–35 min). Flow artifacts were reduced (p = 0.008) and epi/endo-cardial delineation showed good intra and interobserver reproducibility. Paired t-test comparing ejection volume left to right showed no significant difference for 3D (p = 0.37), nor 2D (p = 0.30) and correlation slopes of left to right EV were 1.17 (R2 = 0.75) for 2D and 1.05 (R2 = 0.50) for 3D.Quantifiable ‘late gadolinium enhancement’ infarct volume was seen only with the 3D cine and correlated to histology (R2 = 0.89). Left ejection fraction and MRI-measured infarct volume correlated (R2 > 0.3).ConclusionsThe 4D strategy, with contrast injection, was validated in mice for function and infarct quantification from a single scan with minimal slice planning.  相似文献   

5.
We are developing resonator-QWIPs for narrowband and broadband long wavelength infrared detection. Detector pixels with 25 μm and 30 μm pitches were hybridized to fanout circuits and readout integrated electronics for radiometric measurements. With a low to moderate doping of 0.2–0.5 × 1018 cm−3 and a thin active layer thickness of 0.6–1.3 μm, we achieved a quantum efficiency between 25 and 37% and a conversion efficiency between of 15 and 20%. The temperature at which photocurrent equals dark current is about 65 K under F/2 optics for a cutoff wavelength up to 11 μm. The NEΔT of the FPAs is estimated to be 20 mK at 2 ms integration time and 60 K operating temperature. This good performance confirms the advantages of the resonator-QWIP approach.  相似文献   

6.
Lead zirconate titanate (PZT) nano-powder was prepared by a triol sol–gel process. X-ray diffraction and transmission electron microscopy results showed that as-synthesized amorphous powder started to crystallize at the calcination temperature above 500 °C. The crystalline powder was formed into pellets and sintered at temperatures between 900 and 1300 °C. Co-existence of tetragonal and rhombohedral phase was observed in all ceramics. Microstructural investigation of PZT ceramics showed that uniform grain size distribution with average grain size of ∼0.8–2.5 μm were received with sintering temperature up to 1200 °C. Further increasing the temperature caused abnormal grain growth with the grain as large as 13.5 μm. An attempt to optimize densification with uniform grain size distribution was also performed by varying heating rate and holding time during sintering. It was found that dense (∼97%) sol–gel derived PZT ceramic with uniform microstructure was achieved at 1100 °C with a heating rate of 5 °C min−1 and 6 h dwell time.  相似文献   

7.
Using a cryogenic cell and a series of Distributed Feed Back (DFB) diode lasers, new high resolution spectra of methane have been recorded at 80 K and room temperature by differential absorption spectroscopy (DAS) between 6717 and 7589 cm?1 (1.49–1.32 μm). The investigated spectral region corresponds to the very congested icosad, which is not tractable by theory. Empirical lists of 19,940 and 24,001 lines were constructed from the 80 K and room temperature spectrum, respectively. The room temperature list adds about 8500 features to the empirical list of 15,375 lines at 296 K adopted in the HITRAN database from the original work of L. Brown (Brown, L. Empirical line parameters of methane from 1.1 to 2.1 μm. JQSRT 2005;96:251–70). A number of relatively strong CH4 lines located near strong water lines were found missing in the HITRAN line list. The improved sensitivity allowed adding more than 7000 lines to our previous list of about 12,000 transitions at 80 K (Campargue A, Wang L, Kassi S, Ma?át M, Votava O. Temperature dependence of the absorption spectrum of CH4 by high resolution spectroscopy at 81 K: (II) The Icosad region (1.49–1.30 μm). JQSRT 2010;111:1141–51). In order to facilitate identification of the transitions of the different methane isotopologues present in “natural” isotopic abundance, spectra of highly enriched CH3D and 13CH4 samples were recorded with the same experimental setup, both at room temperature and at 80 K.From the variation of the line strengths between 80 K and 294 K, the low energy values of about 12,000 transitions were determined. They allow accounting for the temperature dependence of 84 and 93% of the methane absorbance in the region, at room temperature and 80 K, respectively. As a result, we provide as supplementary material two complete line lists at 80 K and 294 K, including CH3D and 13CH4 identification and lower state energy values.  相似文献   

8.
Silicon nanostructures, called Si nanowhiskers, have been successfully synthesized on Si(1 0 0) substrate by high vacuum electron beam annealing (EBA). Detailed analysis of the Si nanowhisker morphology depending on annealing temperature, duration and the temperature gradients applied in the annealing cycle is presented. A correlation was found between the variation in annealing temperature and the nanowhisker height and density. Annealing at 935 °C for 0 s, the density of nanowhiskers is about 0.2 μm−2 with average height of 2.4 nm grow on a surface area of 5×5 μm, whereas more than 500 nanowhiskers (density up to 28 μm−2) with an important average height of 4.6 nm for field emission applications grow on the same surface area for a sample annealed at 970 °C for 0 s. At a cooling rate of −50 °C s−1 during the annealing cycle, 10–12 nanowhiskers grew on a surface area of 5×5 μm, whereas close to 500 nanowhiskers grew on the same surface area for samples annealed at the cooling rate of −5 °C s−1. An exponential dependence between the density of Si nanowhiskers and the cooling rate has been found. At 950 °C, the average height of Si nanowhiskers increased from 4.0 to 6.3 nm with an increase of annealing duration from 10 to 180 s. A linear dependence exists between the average height of Si nanowhiskers and annealing duration. Selected results are presented showing the possibility of controlling the density and the height of Si nanowhiskers for improved field emission properties by applying different annealing temperatures, durations and cooling rates.  相似文献   

9.
In the remarkably short span of 2 years, longwave infrared focal plane arrays (FPAs) of Type-II InAs/GaSb strained layer superlattice (SLS) photodiodes have advanced from 320 × 256 format to 1024 × 1024 format while simultaneously shrinking the pitch from 30 μm to 18 μm. Despite a dark current that is presently higher than state-of-the-art mercury cadmium telluride photodiodes with the same ∼10 μm cutoff wavelength, the high pixel operability and high (∼50%) quantum efficiency of SLS FPAs enable excellent imagery with temporal noise equivalent temperature difference better than 30 mK with F/4 optics, integration time less than 1 ms, and operating temperature of 77 K or colder. We present current FPA performance of this promising sensor technology.  相似文献   

10.
In this paper, two hybrid multimode/single mode fiber FabryPérot (FP) cavities were compared. The cavities fabricated by chemical etching are presented as high temperature and strain sensors. In order to produce this FP cavity a single mode fiber was spliced to a graded index multimode fiber with 62.5 μm core diameter. The FabryPérot cavities were tested as a high temperature sensor in the range between room temperature and 700 °C and as strain sensors. A reversible shift of the interferometric peaks with temperature allowed to estimate a sensitivity of 0.75 ± 0.03 pm/°C and 0.98 ± 0.04 pm/°C for the sensor A and B respectively. For strain measurement sensor A demonstrated a sensitivity of 1.85 ± 0.07 pm/μ? and sensor B showed a sensitivity of 3.14 ± 0.05 pm/μ?. The sensors demonstrated the feasibility of low cost fiber optic sensors for high temperature and strain.  相似文献   

11.
New measurements of the absorption cross sections of gaseous benzene, toluene, meta-, ortho-, and para-xylene have been performed with a Fourier transform spectrometer Bruker IFS120 M at the resolution of 1 cm?1 over the 30 000–42 000 cm?1 spectral range. The recordings were carried out under different pressure and temperature conditions with pure samples. The effect of the temperature on the absorption cross sections is investigated. Comparison with the literature shows large differences, largely attributed to the experimental difficulties encountered during these previous measurements and to a resolution effect. To our knowledge, it is the first time that such a dataset of UV absorption cross sections with temperature dependence is reported in the literature. Such data should be useful for upcoming remote sensing applications, such as atmospheric studies both on Earth and on other planets.  相似文献   

12.
This paper proposes a solution to the excessive area penalty associated with traditional buffer direct injection (BDI) for single pixel. The proposed solution reduces the area and power consumption of BDI to combine the direct injection (DI) within a shared architecture, while a dual-mode readout circuit expands the functionality and performance of the array readout circuit of infrared sensor. An experimental array of 10 × 8 readout circuits was fabricated using TSMC 2P4M 0.35 μm 5 V technology. Measurements were obtained using a main clock with a frequency of 3 MHz and power consumption of 9.94 mW. The minimum input current was 119 pA in BDI and 1.85 pA in DI. The signal swing was 2 V, the root mean square noise voltage was 1.84 mV, and the signal-to-noise ratio was 60 dB. This approach is applicable to mid- and long-band sensors to increase injection efficiency and resolution.  相似文献   

13.
The effects of atomic hydrogen and polyimide passivation on R0A product of type-II InAs/GaSb superlattice photo detectors for cut-off wavelength of both 6.5 μm and 12 μm were investigated. Low temperature current–voltage measurement shows that the use of atomic hydrogen during molecular beam epitaxy growth can improve R0A product by 260% for 6.5 μm cut-off superlattice diodes and by 50% for 12 μm cut-off ones. The R0A product of polyimide-passivated diodes with 12 μm cut-off is about 80% higher than those un-passivated ones. Wannier–Stark oscillations at higher reverse bias were observed for polyimide-passivated superlattice diodes with 12 μm cut-off. No Wannier–Stark oscillations were observed for un-passivated superlattice diodes, indicating that surface leakage current dominates in un-passivated diodes, while intrinsic dark current mechanisms such as tunneling and diffusion current dominate in polyimide-passivated diodes.  相似文献   

14.
We have demonstrated 384 × 288 pixels mid-wavelength infrared focal plane arrays (FPA) using type II InAs/GaSb superlattice (T2SL) photodetectors with pitch of 25 μm. Two p-i-n T2SL samples were grown by molecular beam epitaxy with both GaAs-like and InSb-like interface. The diode chips were realized by pixel isolation with both dry etching and wet etching method, and passivation with SiNx layer. The device one with 50% cutoff wavelength of 4.1 μm shows NETD  18 mK from 77 K to 100 K. The NETD of the other device with 50% cutoff wavelength at 5.6 μm is 10 mK at 77 K. Finally, the T2SL FPA shows high quality imaging capability at the temperature ranging from 80 K to 100 K which demonstrates the devices’ good temperature performance.  相似文献   

15.
We developed a very sensitive high-frequency carrier-type thin film sensor with a sub-pT resolution using a transmission line. The sensor element consists of Cu conductor with a meander pattern (20 mm in length, 0.8 mm in width, and 18 μm in thickness), a ground plane, and amorphous CoNbZr film (4 μm in thickness). The amplitude modulation technique was employed to enhance the magnetic field resolution for measurement of the high-frequency field (499 kHz), a resolution of 7.10×10?13 T/Hz1/2 being achieved, when we applied an AC magnetic field at 499 kHz. The phase detection technique was applied for measurement of the low frequency field (around 1 Hz). A small phase change was detected using a dual mixer time difference method. A high phase change of 130°/Oe was observed. A magnetic field resolution of 1.35×10?12 T/Hz1/2 was obtained when a small AC field at 1 Hz was applied. We applied the sensor for magnetocardiogram (MCG) measurement using the phase detection technique. We succeeded in measuring the MCG signal including typical QRS and T waves, and compared the MCG with a simultaneously obtained conventional electrocardiogram (ECG) signal.  相似文献   

16.
《Ultrasonics sonochemistry》2014,21(6):2092-2098
This study showed that temperature influences the rate of separation of fat from natural whole milk during application of ultrasonic standing waves. In this study, natural whole milk was sonicated at 600 kHz (583 W/L) or 1 MHz (311 W/L) with a starting bulk temperature of 5, 25, or 40 °C. Comparisons on separation efficiency were performed with and without sonication. Sonication using 1 MHz for 5 min at 25 °C was shown to be more effective for fat separation than the other conditions tested with and without ultrasound, resulting in a relative change from 3.5 ± 0.06% (w/v) fat initially, of −52.3 ± 2.3% (reduction to 1.6 ± 0.07% (w/v) fat) in the skimmed milk layer and 184.8 ± 33.2% (increase to 9.9 ± 1.0% (w/v) fat) in the top layer, at an average skimming rate of ∼5 g fat/min. A shift in the volume weighted mean diameter (D[4,3]) of the milk samples obtained from the top and bottom of between 8% and 10% relative to an initial sample D[4,3] value of 4.5 ± 0.06 μm was also achieved under these conditions. In general, faster fat separation was seen in natural milk when natural creaming occurred at room temperature and this separation trend was enhanced after the application of high frequency ultrasound.  相似文献   

17.
Vanadium dioxide has excellent phase transition characteristic. Before or after phase transition, its optical, electrical, magnetic characteristic hangs hugely. It has a wide application prospect in many areas. Now, the light which can make vanadium dioxide come to pass photoinduced phase transition range from soft X-ray to medium infrared light (6.9 μm, 180 meV). However, whether 10.6 μm (117 meV) long wave infrared light can make vanadium dioxide generate photoinduced phase transition has been not studied. In this paper, we researched the response characteristic of vanadium dioxide excited by 10.6 μm infrared light. We prepared the vanadium dioxide and test the changes of vanadium dioxide thin film’s transmittance to 632.8 nm infrared light when the thin film is irradiate by CO2 laser. We also test the resistivity of vanadium dioxide. Excluding the effect of thermal induced phase transition, we find that the transmittance of vanadium dioxide thin film to 632.8 nm light and resistivity both changes when irradiating by 10.6 μm laser. This indicates that 10.6 μm infrared light can make the vanadium dioxide come to pass photoinduced phase transition. The finding makes vanadium has a potential application in recording the long-wave infrared hologram and making infrared detector with high resolution.  相似文献   

18.
High resolution chronoamperometry has been used to characterize the effect of two non-ionic surfactants, Triton® X-100 and NCW®-1002, on cavitation in aqueous solutions exposed to ~1 MHz sound field. Specifically, using ferricyanide as the electroactive species, temporal variation of current during its reduction on a 25 μm Pt microelectrode has been measured and is used to elucidate transient cavity behavior. The chronoamperograms for solutions exposed to megasonic field show current ‘peaks’ riding on the baseline current. These current ‘peaks’ have been attributed to the diffusion of ferricyanide species concentrated at the liquid–vapor interface of a transient cavity at the end of its collapse. In the presence of surfactants, the frequency of occurrence of current ‘peaks’ with magnitude ?0.3 μA is found to increase indicating a higher number of transient cavity collapses. A simple mathematical model based on diffusion developed previously by the authors has been used to extract the maximum cavity size and range of distances between the center of the collapsing cavity and the electrode surface in the surfactant solutions.  相似文献   

19.
Short-/Mid-Wavelength dual-color infrared focal plane arrays based on Type-II InAs/GaSb superlattice are demonstrated on GaSb substrate. The material is grown with 50% cut-off wavelength of 2.9 μm and 5.1 μm for the blue channel and red channel, separately at 77 K. 320 × 256 focal plane arrays fabricated in this wafer is characterized. The peak quantum efficiency without antireflective coating is 37% at 1.7 μm under no bias voltage and 28% at 3.2 μm under bias voltage of 130 mV. The peak specific detectivity are 1.51 × 1012 cm·Hz1/2/W at 2.5 μm and 6.11x1011 cm·Hz1/2/W at 3.2 μm. At 77 K, the noise equivalent difference temperature presents average values of 107 mK and 487 mK for the blue channel and red channel separately.  相似文献   

20.
Room temperature solution processing is used for cross-linked upright-standing ZnO nano-sheets growth of ∼2–5 μm in length and ∼100–150 nm in width. These nano-sheets are characterized for structural and surface morphological analyses. Energy dispersive X-ray spectrum is preferred to chemical analysis. Confirmation of well defined, cross-linked and distinct ZnO nano-sheets of quoted dimensions is carried out using a scanning electron microscopy. Porous nature of nano-sheets with fine edge boundaries is noted from low resolution transmission electron microscopy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号