首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
The LM–OSL signal of quartz, while measured at room temperature, is dominated by an intermediate, broad and intense OSL component, so that its contribution and general characteristics are derived very accurately. Through a series of dose–response, bleaching and thermal decay at room temperature experiments, in conjunction with curve fitting studies, a component resolved analysis is carried out studying the correlation between this specific component, termed as LM–OSL component C2 and the 110 °C TL glow peak in quartz. The dose–response of these two luminescence components behaves exactly similar being linear at low doses and saturating at almost 100 Gy. Both signals decay exponentially under illumination, providing identical optical detrapping cross-section values. Residual of both luminescence signals after thermal decay at room temperature follows an exponential law, yielding similar mean half-lives. All previous luminescence features provide strong evidence for the electron trap being the same for both the 110 °C TL trap and the LM–OSL component C2. The results of the present work are very promising and clearly support the possibility of extrapolating the TL pre-dose methodology to the OSL pre-dose effect using only the LM–OSL component C2.  相似文献   

2.
Laboratory storage and preheating experiments were carried out to study anomalous fading of infrared stimulated luminescence (IRSL) signals derived from polymineral grains extracted from Chinese loess. Results of laboratory storage at 150 °C and higher temperature preheating experiments showed that such thermal treatments could lessen the effect of fading and indicated the presence of both thermal and non-thermal fading. In addition, the behavior of natural fading over the past 9–170 ka was investigated. By comparing with independent ages (obtained from fine-grain quartz using the optically stimulated luminescence (OSL) signal for the past 130 ka and the thermally transferred OSL (TT-OSL) signal in the age range of 130–170 ka) for the same samples, equivalent doses obtained from the IRSL signals were found to be underestimated by different amounts since the penultimate glacial; there was a linear dependence when the age underestimation was plotted against geological time.  相似文献   

3.
Quartz extracted from heated bricks has been previously suggested for use in dose estimation in accident dosimetry, but this technique has never been applied before to Japanese quartz which often has unusual OSL characteristics. In this study the optically stimulated luminescence (OSL) characteristics of quartz extracted from a Japanese commercial red brick produced by Mishima – Renga – Seizoujyo Co. are studied. These companies are based in the Aichi Prefecture (capital Nagoya), which accounts for about half of the red brick production in Japan. A comparison of TL (thermoluminescence) and OSL signals has been carried out towards identification of common source traps. It is observed that OSL from Japanese brick quartz shows unusual luminescence characteristics; in particular, the initial fast decaying OSL signal contains a dominant (>90%) thermally unstable component related to the 85 °C TL peak, which necessitates a prior heat treatment. A single-aliquot regenerative-dose (SAR) protocol is developed and tested using thermal treatments intended to isolate a stable dosimetric signal. A minimum detection limit of ~65 mGy is then estimated using this protocol. Following irradiation using 60Co and 137Cs, dose–depth profiles were measured on two different commercial brick types (Mishima – Renga – Seizoujyo Co. and Hase – Renga Co.) with 5 Gy and 10 Gy surface doses. The profiles derived from the two sources were readily distinguishable. It is concluded that the OSL signals from the two types of Japanese brick quartz examined here can be used to derive precise estimates of accident dose, and, possibly to distinguish between sources of gamma radiation in a nuclear accident.To our knowledge, this is the first report on the existence of an unstable fast decaying OSL signal in quartz derived from bricks, and demonstrates a way forward with such samples in retrospective dosimetry.  相似文献   

4.
《Radiation measurements》2009,44(3):232-238
A flow-through Geiger-Müller pancake electron detector attachment has been fitted to a standard Risø TL/OSL reader enabling optically stimulated electrons (OSE) to be measured simultaneously with optically stimulated luminescence (OSL). Using this detector, OSE and OSL measurements from natural quartz samples are studied to examine the possible use of OSE as a chronometer. First the relative variability in OSE and OSL growth curve shapes and the effect of preheat on these are presented, and from these curves, conclusions are drawn concerning the charge movement in natural quartz. Secondly, a dose recovery test shows that OSE can successfully recover a laboratory dose of 300 Gy given before any laboratory thermal treatment, for preheating temperatures between 160 and 260 °C. Furthermore, for the first time natural OSE decay curves are detected and these signals are used to estimate a burial dose using the single-aliquot regenerative-dose (SAR) procedure. Finally, a comparative study of the equivalent doses estimated using both OSE and OSL from 10 quartz samples are presented, and it is shown that OSE has a significant potential in retrospective dosimetry.  相似文献   

5.
International recommendations establish that 90Sr + 90Y clinical applicators have to be calibrated in order to determine the absorbed dose rates in the case of the sources that do not have original calibration certificates, or to update the absorbed dose rates presented in the source certificates. Following these recommendations, a postal dosimetric system was developed to calibrate clinical applicators using two luminescent techniques: thermoluminescence (TL) and optically stimulated luminescence (OSL). In this work, Al2O3:C commercial detectors were characterized and their TL and OSL responses were analyzed. The results showed the efficiency and the optimal behavior of this material in beta radiation beams. After characterization, the system was sent to the Federal University of Sergipe (UFS), Brazil, for calibration of five 90Sr + 90Y clinical applicators, where the detectors were irradiated and returned to IPEN, for their evaluation and determination of the absorbed dose rates. A comparison between these absorbed dose rates and those adopted by the UFS as original was made; the differences obtained were within those of other studies, and they demonstrated the usefulness of the system.  相似文献   

6.
《Radiation measurements》2009,44(2):158-162
Optical fibers have been proposed as dosimeters in both diagnostic and radiotherapy applications. A commercial germanium (Ge)-doped silica fiber with a 50 μm core diameter which showed good thermoluminescence (TL) properties was selected for this study. The radiation sources used were a high dose rate brachytherapy iridium-192, MV photon and MeV electron beams from a linear accelerator. The coating of the fiber was chemically removed and then annealed at 400 °C for 1 h prior to irradiation. After irradiation, the fiber was read on a Harshaw Model 3500 TLD reader. The optical fiber had one well-defined glow peak at 327 ± 2 °C at all the radiotherapy energies. The dose response was linear within the clinical relevant dose for all these energies. Reproducibility was mainly within 4–6% (one standard deviation) for high energy photons and electrons. The fiber was found to be energy independent within the MV photon energy range. At room temperature the fading up until 1 month was around 6% which was within the 6% uncertainty of the sensitivity calibration of the fiber. Re-using the fiber four times did not significantly alter the sensitivity factor. The optical fiber was found to be dose rate as well as angular independent. Central axis depth dose curves of both 10 MV photons and 12 MeV electrons using the fiber showed relatively good agreement to standard depth dose curves in water within 4%. The Ge-doped fiber is a promising TL dosimeter but improvements have to be made to reduce the reproducibility within 3% for high energy photons and electrons.  相似文献   

7.
The fast, linearly modulated optically stimulated luminescence (LM-OSL) component in quartz is the main dosimetric signal used for the dating applications of this material. Since the blue light stimulation (470 nm, 40 mW cm ?2) time needed to obtain the fast LM-OSL component is less than 50 s the electron trapping levels responsible for it are still highly populated. In this way an active radiation history is created which could play an important role in the dosimetric characteristics of the fast OSL signal. In the present work the dose response behavior of the fast OSL signal is investigated in quartz samples with an annealed radiation history and quartz samples possessing an artificial radiation history. A computerized curve de-convolution analysis of the LM-OSL curves for 50 s stimulation time showed that it consists of three individual OSL components. The faster component C1 with peak maximum time around 5 s has a linear dose response in virgin samples, which turns to a slight superlinearity as a function of the artificial radiation history. On the other hand the component C2 with peak maximum time at 12 s is slightly superlinear which turns into strong superlinearity as a function of artificial radiation history. Finally, component C3 with peak maximum time at about 45 s is strongly superlinear for both virgin samples and as a function of artificial radiation history. The implications to practical application are discussed.  相似文献   

8.
《Radiation measurements》2007,42(2):144-155
The structure of the linearly modulated optically stimulated luminescence (LM-OSL) signal was studied for four sedimentary quartz samples, collected from different sites around Istanbul, Turkey. Applying a computerized deconvolution analysis to the LM-OSL curves, at least six individual components of first-order kinetics were identified and photoionization cross-section of each component was evaluated. The OSL dose–response curve of each component for each quartz sample was obtained, showing a remarkable differentiation from component to component. The behavior of a highly dosed sample to successive LM-OSL measurements was also studied showing a stable recuperation signal in the position of the “slow” and “medium” components and high resistance to OSL bleaching of the “slow” component. The individual sensitivity of each component as a function of the activation temperature was obtained. The sensitivity of each component was normalized over the respective sensitivity of the glow-peak at 110 °C of quartz in order to investigate the ability of the 110 °C glow-peak to act as a correction factor for all components of the LM-OSL curves examined.  相似文献   

9.
The present work suggests an alternative experimental method in order to not only measure the signal of the deep traps in Al2O3:C without heating the sample to temperatures greater than 500 °C, but also use this signal for high dose level dosimetry purposes as well. This method consists of photo transfer OSL measurements performed at elevated temperatures using the blue LEDs (470 nm, FWHM 20 nm) housed at commercial Risø TL/OSL systems, after the sample was previously heated up to 500 °C in order to empty its main TL dosimetric trap. The influence of this procedure on specific features such as glow curve shape and sensitivity of the main TL glow peak was also studied.  相似文献   

10.
This study presents the first dosimetric evaluation of the alanine-in-glass dosimeter in radiation therapy. The dosimeter is composed of a Pyrex glass tube filled with pure polycrystalline alanine. 6 MV X-ray beams from a linear accelerator were used to irradiate the dosimeter in a solid water phantom to therapy-level doses ranging from 0 to 30 Gy. An X-band electron paramagnetic resonance (EPR) spectrometer was utilized to measure the absorbed dose of the dosimeter. The doses measured by the dosimeter were compared to those from ion chamber dosimetry. It was found that the dosimeter exhibited a linear response in the dose range from 0.1 to 30 Gy. The deviation between measured and delivered doses was 0.11% over the 0.5–30 Gy range, whereas the deviation increased to about 25% at 0.1 Gy. The lowest detectable dose with an acceptable deviation limit of 5% or less was found to be 0.3 Gy. The inaccuracy in measurements at low doses can be attributed to background signals and instrument noise. The accuracy can be improved by proper selection of measurement conditions and better optimization of equipment. The findings of this study show that the alanine-in-glass dosimeter is suitable for dose measurements with acceptable accuracy down to 0.3 Gy. The dosimeter is therefore has the potential to be employed in radiotherapy applications and quality control procedures.  相似文献   

11.
The post-IR IRSL protocol with single K-feldspar grains was applied to three samples taken from a fluvial sedimentary sequence at the archaeological site of the Dali Man, Shaanxi Province, China. K-feldspar coarse grains were extracted for measurement. Approximately 30–40% of the grains were sufficiently bright to measure, and after application of rejection criteria based on signal strength, recuperation, recycling ratio and saturation dose, ~10–15% of the grains were used for De calculation. The relationship of signal decay rate and form of De(t) with the recovery dose were investigated. The dose recovery ratios of the samples after initial bleaching with the four different light sources were within uncertainties of unity. No anomalous fading was observed. The over-dispersion of the recovered dose and De values were similar, suggesting neither incomplete resetting of the post-IR IRSL signals nor spatially heterogeneous dose rates significantly affected the natural dose estimates. The values of De obtained with the single K-feldspar grain post-IR IRSL protocol were in the range ~400–490 Gy. Combining all of the measured single-grain signals for each of the individual samples (into a ‘synthetic single aliquot’) increased the De estimates to the range ~700–900 Gy, suggesting that the grains screened-out by the rejection criteria may have the potential to cause palaeodose over-estimation, although this finding requires a more extensive investigation. Thermally transferred signals were found in the single K-feldspar grains post-IR IRSL protocol, and the proportion of thermally transferred signal to test-dose OSL signal (stimulation at 290 °C) from the natural dose was higher than from regenerative doses, and the proportion was grain- and dose-dependent. As such, TT-post-IR IRSL signals at 290 °C have the potential to cause dose underestimation, although this may be reduced by using larger test-dose irradiations. Our study demonstrates considerable potential in the post-IR IRSL method in providing chronological control in studies relevant to human evolution in the later-Pleistocene.  相似文献   

12.
Pulsed OSL is applied to nine fine-grained sediment samples from Sichuan province, China, using stimulating pulses of 10 μs on and 240 μs off, with an infrared exposure prior to each OSL measurement. Comparison of fading rates between pulsed and non-pulsed signals, the latter also obtained with a preceding IR exposure, shows that fading is significant for mainly the non-pulsed signals. Presence of a pulsed IRSL and the magnitudes of b-value to correct for lower alpha efficiency suggest that pulsing does not fully remove a significant feldspar signal, only a fading component. Comparison with ages of quartz extracts shows that pulsed OSL ages are consistent, while CW-OSL ages are slightly older and CW-IRSL ages are much older. The older ages suggest a less well-bleached feldspar component.  相似文献   

13.
Optically stimulated luminescence (OSL) measurements of quartz are widely used to measure equivalent dose (De). At radiation doses above ~100 Gy, saturation of traps results in a decrease in the rate of growth of the OSL signal, and this makes calculation of De increasingly difficult. A series of dose recovery experiments was undertaken using single grains of quartz from Kalambo Falls, Zambia to explore saturation of single grains. When the OSL signal from many grains is averaged, the characteristic dose (D0) is 47 Gy, typical of published values for quartz. However, D0 for individual grains varies from ~10 to 100 Gy. Doses up to two times the average D0 could be accurately recovered, but above this dose the De became increasingly underestimated. Overdispersion for this type of experiment should be zero, but was observed in all data sets; furthermore the value of overdispersion increased with De. An additional acceptance criterion, the Fast Ratio, is suggested for single grain OSL analysis. This criterion assesses the relative contribution of the fast component of the OSL signal. Including this as an additional acceptance criterion leads to an improved precision, with overdispersion reduced to zero, and improved accuracy in dose recovery at high doses.  相似文献   

14.
《Radiation measurements》2009,44(2):149-157
In this study, we applied optically stimulated luminescence (OSL) dating to two fine grain sediment samples collected at Jeongokri, Korea. A single aliquot regenerative dose (SAR) procedure was applied to both polymineral grains and to chemically isolated (H2SiF6) quartz grains of 4–11 μm diameter. For polymineral fine grains, the OSL IR depletion ratio and the equivalent dose (De) plateau test appear to be equally sensitive indicators of appropriate IR stimulation time for use in the ‘double SAR’ protocol. Additionally, the OSL IR depletion ratio test gives an indication of the relative mineral composition of the samples, hence providing an assessment of the likelihood of obtaining a quartz-dominated [post-IR] OSL signal. Use of higher preheat temperatures would assist in thermally eroding the non-quartz component of the [post-IR] OSL signal from polyminerals. For the quartz fine grains, data from both natural De determinations and laboratory dose recovery tests are required to identify the appropriate preheat temperatures for dating, due to problems of thermal transfer. This phenomenon is particularly exaggerated for these samples due to the large De values (≥350 Gy) and hence low slope of the dose–response curve. The double SAR method cannot be applied ubiquitously, even after careful and rigorous study of one sample from a section. Quartz OSL dating using a range of preheat temperatures is suggested to be the most suitable method for OSL dating of fine grain sediments.  相似文献   

15.
16.
《Radiation measurements》2007,42(2):190-197
An optically stimulated luminescence (OSL) age obtained from a Japanese tephra using quartz phenocrysts severely underestimated the known age. The characteristics of the OSL signals were investigated in order to understand the cause of the underestimation; the main OSL component of volcanic quartz has a thermodynamic lifetime of about 1700 years at room temperature, and it also seems to fade anomalously (i.e. athermally). Measurement of conventional red thermoluminescence (RTL) using a Ga–As photomultiplier tube was difficult due to the presence of a strong thermal background, although RTL gave an age consistent with the independent age. Furthermore, red isothermal TL (RITL) at 380 °C allowed the RTL signal to be separated from to the thermal background, and RITL ages of three volcanic quartz samples show good agreement with independent ages.  相似文献   

17.
Regularities of afterglow at room temperature and of thermoluminescence at further heating up to 673 K have been studied in bulk aluminum nitride single crystals. It has been established that after exposure to β-irradiation luminescence decay at RT may be described by superposition of two exponential components: fast (59 s) and slow (606 s) ones, caused by defects of the anion crystal sublattice ON- and VN-centers, respectively. The afterglow spectrum is shown to be characterized by the 3.43 eV band with FWHM=0.61 eV that dominates also in the thermoluminescence under study. From analysis of the TL curves in terms of the general order formalism it has been concluded that variation of the activation energy observed within the 0.46–0.85 eV range with increasing storage of the samples from 5 min to 3 days may be caused by energy distribution of traps on the basis of oxygen-related centers. For the first time the compensation effect has been found, and phenomenologically interpreted for the TL processes of the AlN single crystals. Isokinetic temperature has been estimated within the framework of empiric and non-empiric relations.  相似文献   

18.
Hf metal with ∼ 3 wt% Zr impurity has been reinvestigated by perturbed angular correlation (PAC) spectroscopy using a LaBr3(Ce)–BaF2 detector set up to understand the microscopic behavior of this metal with temperature. From present measurements, five quadrupole interaction frequencies have been found at room temperature where both pure hcp fraction (∼33%) with 12 nearest neighbor Hf surrounding the probe 181Hf atom and the probe–impurity fraction (∼33%) corresponding to 11 nearest neighbor Hf plus one dissimilar Zr atom are clearly distinguished. At room temperature, the results for quadrupole frequency and asymmetry parameter are found to be ωQ=51.6(4) Mrad/s, η=0.20(4) for the impurity fraction and ωQ=46.8(2) Mrad/s, η=0 for the pure fraction with values of frequency distribution width δ=0 for both components. At 77 K, only 1 NN Zr impurity (∼93%) and pure hcp (∼7%) components have been found with a value of δ ∼ 10% for the impurity fraction. A drastic change in microstructural configuration of Hf metal is observed at 473 K where the impurity fraction increases to ∼ 50% and the pure hcp fraction reduces to ∼ 15% with abrupt changes in quadrupole frequencies for both components. The pure fraction then increases with temperature and enhances to ∼50% at 973 K. In the temperature range 473–973 K, quadrupole frequencies for both components are found to decrease slowly with temperature. Using the Arrhenius relation, binding energy (B) for the probe–impurity pair and the entropy of formation are measured from temperature dependent fractions of probe–impurity and pure hcp in the temperature range 473–773 K. The three other minor components found at different temperatures are attributed to crystalline defects.  相似文献   

19.
The feasibility of utilizing the pre-dosed OSL signal in the estimation of the equivalent dose has been investigated. The results based on (i) the behavior of growth curve, (ii) dose recovery tests and (iii) non-bleachability of reservoir centres, R-centres, suggests that (i) the pre-dosed OSL does not seem to work satisfactorily in dose estimation unlike the pre-dosed 110 °C TL emission and (ii) it may not be applicable in case of bleached specimen.  相似文献   

20.
Lead iodide polycrystalline films have been deposited on corning glass substrates using solution evaporation in oven. Films 6 μm-thick were obtained with full coverage of the substrates as verified by scanning electron microscopy. Some pin-holes were observable. X-ray diffraction revealed a crystalline structure corresponding to the 4 H–PbI2 polytype formation. Polarized Raman scattering experiments indicated a lamellar structure. Anisotropy was also investigated using depolarization ratio calculations. The optical and electrical properties of the samples were investigated using photoluminescence and dark conductivity as a function of temperature, respectively. Activation energies of 0.10 up to 0.89 eV were related to two main electrical transport mechanisms. Films were also exposed to X-ray irradiation in the mammography X-ray energy range. The detector produced was also exposed to X-ray from 5 mR up to 1450 mR. A linear response was observed as a function of dose with a slope of 0.52 nA/mm2 per mR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号