1.
黄倩  何蔓  陈贝贝  胡斌 《色谱》2014,32(10):1131-1137
制备了苯乙烯(St)和甲基丙烯酸(MAA)共聚物改性的磁性微球Fe3O4@P(St-co-MAA),并将其作为磁固相萃取吸附剂,建立了磁固相萃取(MSPE)-气相色谱(GC)-火焰光度检测(FPD)联用分析有机磷农药(OPPs)残留的新方法。以5种有机磷农药(二嗪农、甲基毒死蜱、杀螟硫磷、毒死蜱和喹硫磷)为目标分析物,考察并优化了吸附和解吸条件,确定了最佳实验条件。在最优的实验条件下,方法对5种OPPs的检出限(S/N=3)为0.013~0.305 μg/L,方法的相对标准偏差(RSD,n=7)为3.1%~8.8%,富集倍数为406~951,线性范围达3个数量级。将该方法应用于新鲜番茄汁、草莓汁样品中的OPPs残留分析,加标回收率为85.4%~118.9%。该方法具有检出限低、分析速度快、富集倍数高等优点,为有机磷农药的残留分析提供了新的技术平台。  相似文献   

2.
This paper describes the extraction of 49 organophosphorus pesti-cides (OPPs) from water samples using solid-phase microextraction (SPME). Three fibers, including a 15-μm XAD-coated fiber, a 85-μm polyacrylate-coated fiber, and a 30-μm polydimethylsilox-ane-coated fiber (PDMS), were evaluated here. The effects of stirring and the addition of NaCl to the sample were examined for the polyacrylate-coated fiber. The precision of the technique was examined for all three fibers and the extraction kinetics were investigated using the XAD- and polyacrylate-coated fibers. With some exceptions, the XAD- and polyacrylate-coated fibers performed better than the PDMS-coated fiber. The superiority of the XAD-nd polyacrylate-coated fiber. The superiority of the XAD- and polyacrylate-coated fibers over the PDMS-coated fibers can be attribuibuted to the aromatic functionalities of the XAD and the polar functionalities in the polyacrylate. The relatively high percent RSDs indicate that the SPME technique needs to be further refined before it can be used for anything other than screening. A more effective form of agitation than mechanical stirring may be neccessary to reduce variability and achieve a faster equilibrium between the sample and the SPME fiber.  相似文献   

3.
Xiao Q  Hu B  Yu C  Xia L  Jiang Z 《Talanta》2006,69(4):848-855
A single-drop microextraction (SDME) procedure was developed for the analysis of organophosphorus pesticides (OPPs) in water and fruit juice by gas chromatography (GC) with flame photometric detection (GC-FPD). The significant parameters affecting the SDME performance such as selection of microextraction solvent, solvent volume, extraction time, stirring rate, sample pH and temperature, and ionic strength were studied and optimized. Two types of SDME mode, static and cycle-flow SDME, were evaluated. The static SDME procedure provided more sensitive analysis of the target analytes. Therefore, static SDME with tributyl phosphate (TBP) as internal standard was selected for the real sample analysis. The limits of detection (LODs) in water for the six studied compounds were between 0.21 and 0.56 ng/mL with the relative standard deviations ranging from 1.7 to 10.0%. Linear response data was obtained in the concentration range of 0.5-50 ng/mL (except for dichlorvos 1.0-50 ng/mL) with correlation coefficients from 0.9995 to 0.9999. Environmental water sample collected from East Lake and fruit juice samples were successfully analyzed using the proposed method, but none of the analytes in both lake water and fruit juice were detected. The recoveries for the spiked water and juice samples were from 77.7 to 113.6%. Compared with the conventional methods, the proposed method enabled a rapid and simple determination of organophosphorus pesticides in water and fruit juice with minimal solvent consumption and a higher concentration capability.  相似文献   

4.
A method for the determination of trace Cr(III) in aqueous solution by solid-phase microextraction (SPME) coupled with gas chromatography (GC)-flame photometric detection (FPD) was developed. Aqueous Cr(III) was first converted to the volatile chromium trifluoroacetylacetonate (Cr(tfa)3) by derivatization with 1,1,1-trifluoroacetylacetone (Htfa), followed by SPME extraction using a polyimide-coated silica fiber. The distribution constants (K) of derivatized cis- and trans-Cr(tfa)3 between the polyimide phase and aqueous phase were 2012 and 2214, respectively. The two Cr(tfa)3 isomers extracted can be efficiently separated by a DB-210 GC column within 9 min. Selective detection of Cr was performed by a FPD equipped with a 385-nm long-pass filter. Linearity (r> 0.99) over the concentration range 5-300 ng ml(-1) Cr was obtained and the limit of detection was 2 ng ml(-1) Cr. The relative standard deviation was 7% at 10 ng ml(-1) Cr (n = 5). Applicability of this method to water analysis was tested by analyzing the chromium content in a reference standard water sample and an industrial effluent.  相似文献   

5.
Summary The potential of microcolumn liquid chromatography (μlC) and capillary electrophoresis (CE) with on-line, flame photometric detection (FPD) in the P-selective mode has been studied for determination of polar P-containing pesticides, glyphosate and its main metabolite, aminomethylphosphonic acid (AMPA), ethephon, fosetyl-aluminium and acephate. Acephate was determined by reversed-phase μLLC-FPD using large-volume injections with peak compression, the other compounds were determined by μLC-FPD and CE-FPD using simple, large-volume injection procedures to obtain limits of detection of 7.5-500 ng·mL−1 and 1.0 μ·mL−1, respectively. The methods showed acceptable repeatability and robustness and were successfully applied for rapid and selective determination of pesticides in fruit, vegetable and water samples.  相似文献   

6.
Solid‐phase extraction coupled with dispersive liquid–liquid microextraction was developed as an ultra‐preconcentration method for the determination of four organophosphorus pesticides (isocarbophos, parathion‐methyl, triazophos and fenitrothion) in water samples. The analytes considered in this study were rapidly extracted and concentrated from large volumes of aqueous solutions (100 mL) by solid‐phase extraction coupled with dispersive liquid–liquid microextraction and then analyzed using high performance liquid chromatography. Experimental variables including type and volume of elution solvent, volume and flow rate of sample solution, salt concentration, type and volume of extraction solvent and sample solution pH were investigated for the solid‐phase extraction coupled with dispersive liquid–liquid microextraction with these analytes, and the best results were obtained using methanol as eluent and ethylene chloride as extraction solvent. Under the optimal conditions, an exhaustive extraction for four analytes (recoveries >86.9%) and high enrichment factors were attained. The limits of detection were between 0.021 and 0.15 μg/L. The relative standard deviations for 0.5 μg/L of the pesticides in water were in the range of 1.9–6.8% (n = 5). The proposed strategy offered the advantages of simple operation, high enrichment factor and sensitivity and was successfully applied to the determination of four organophosphorus pesticides in water samples.  相似文献   

7.
Wang JX  Jiang DQ  Yan XP 《Talanta》2006,68(3):945-950
A method for determination of toluene, ethylbenzene, p-xylene, o-xylene, 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene in water samples was developed by a fiber-in-tube liquid phase microextraction technique (fiber-in-tube LPME) coupled with GC-flame ionization detector (FID). The method used a tube packed with polytetrafluoroethylene (PTFE) fibers as an extraction medium, improving the stableness of the solvent and the performance of extraction. Certain amounts of curled PTFE fibers were packed into a section of PTFE tube. Because the fibers were curled, they formed network structure in the tube. The fiber packed tube was firstly immersed into organic solvent to be filled with organic solvent and then was exposing to an aqueous solution to extract the target compounds. The extract was then retracted by a conventional GC microsyringe and analyzed by GC-FID. Extraction of the analytes in 8 ml aqueous solution for 15 min yielded enrichment factors of 224-361. The precision (R.S.D., n = 5) was 3.6-8.1% for peak area. The limit of detection (LOD, S/N = 3) for the six substituted benzenes were in the range of 0.3-5.0 μg l−1.  相似文献   

8.
A liquid‐phase microextraction coupled with LC method has been developed for the determination of organophosphorus pesticides (methidation, quinalphos and profenofos) in drinking water samples. In this method, a small amount (3 μL) of isooctane as the acceptor phase was introduced continually to fill‐up the channel of a 1.5 cm polypropylene hollow fiber using a microsyringe while the hollow fiber was immersed in an aqueous donor solution. A portion of the acceptor phase (ca. 0.4 μL) was first introduced into the hollow fiber and additional amounts (ca. 0.2 μL) of the acceptor phase were introduced to replenish at intervals of 3 min until set end of extraction (40 min). After extraction, the acceptor phase was withdrawn and transferred into a 2 mL vial for a drying step prior to injection into a LC system. Parameters that affect the extraction efficiency were studied including the organic solvent, length of fiber, volume of acceptor and donor phase, stirring rate, extraction time, and effect of salting out. The proposed method provided good enrichment factors of up to 189.50, with RSD ranging from 0.10 to 0.29%, analyte recoveries of over 79.80% and good linearity ranging from 10.0 to 1.25 mg/L. The LOD ranged from 2.86 to 82.66 μg/L. This method was applied successfully to the determination of organophosphorus pesticides in selected drinking water samples.  相似文献   

9.
A new mesoporous silica based on the sol–gel material cyanopropyltriethoxysilane (CNPrTEOS) was successfully synthesized by the hydrolysis and condensation of CNPrTEOS in the presence of ammonium solution as catalyst and methanol as solvent. It was used as a solid‐phase extraction sorbent for the simultaneous extraction of three organophosphorus pesticides, namely, polar dicrotophos and non‐polar diazinon and chlorpyrifos. Analysis was performed using high‐performance liquid chromatography with UV detection. CNPrTEOS was characterized by FTIR spectroscopy, field‐emission scanning electron microscopy and nitrogen gas adsorption. The surface area and average pore diameter of the optimum sol–gel CNPrTEOS are 379 m2/g and 4.7 nm (mesoporous), respectively. The proposed solid‐phase extraction based on CNPrTEOS exhibited good linearity in the range of 0.8–100 μg/L, satisfactory precision (1.15–3.82%), high enrichment factor (800) and low limit of detection (0.072–0.091 μg/L). The limits of detection obtained using the proposed solid‐phase extraction method are well below the maximum residue limit set by European Union and are also lower (13.6–48.5×) than that obtained by using a commercial CN‐SPE cartridge (0.98–4.41 μg/L). The new mesoporous sol–gel CNPrTEOS showed promising alternative as SPE sorbent material for the simultaneous extraction of polar and non‐polar organophosphorus pesticides.  相似文献   

10.
The potential of an interface for the on-line coupling of microcolumn liquid chromatography (LC)and a flame photometric detector (FPD) has been further investigated. With the micro-LC/FPD system, relatively high-molecular-weight polar compounds such as cyclic adenosine monophosphate, guanosine monophos- phate, glucose monophosphate, fructose monophosphate, and phytic acid were separated and selectively detected. In order to increase the sensitivity, on-line preconcentration with a microprecolumn inserted in the rotorof a Valcovalve has been applied. Preliminary results have shown that an injection volume of at least 500 1-11 water containing organophosphorus acids at a 5–50 ng/rnl concentration level is possible.  相似文献   

11.
This paper describes the extraction of 20 organochlorine pesticides (OCPs) from water samples using solid-phase microextraction (SPME). Three fused-silica fibers coated or bonded with polydimethylsiloxane (PDMS) of different film thicknesses (20-, 30-, and 100-μm) were evaluated. The extraction time, the effects of stirring and addition of NaCl to the aqueous sample, the linear range and the precision of this technique, and the effect of carryover were examined for 20 analytes and are presented here. A comparison with results using conventional liquid-liquid extraction demonstrate that the SPME technique is well suited as a fast screening technique for OCPs in water samples.  相似文献   

12.
A method based on immersed solid-phase microextraction (SPME) and gas chromatography mass spectrometry detection (GC-MS) for the determination of organophosphorous pesticides (OPPs) in aqueous samples was developed. A sol-gel based coating fiber was prepared using 3-(trimethoxysilylpropyl) amine as precursor. The synthesized fiber was prepared in a way to impart polar moiety into the coating network and would be more suitable for extracting polar and semi-polar organic pollutants. Important parameters influencing the extraction process were optimized and an extraction time of 40 min at 30 °C gave maximum peak area, when NaCl (20% w/v) was added to the aqueous sample. The linearity for disulfoton, phorate and sulfotep was in the concentration range of 0.01 to 5 ng mL− 1 and for parathion and O,O,O-triethylthiphosphate was in the range of 0.01 to 50 ng mL− 1. Limits of detection ranged from 1 ng L− 1, for parathion, to 0.05 ng L− 1, for disulfoton using time-scheduled selected ion monitoring (SIM) mode, and the RSD% values were all below 10.5% at the 1 ng mL− 1 level. The developed method was successfully applied to real water samples while the relative recovery percentages obtained for the spiked water samples were from 80 to 115%.  相似文献   

13.
A novel method was described for the rapid determination of atrazine using dispersive liquid phase microextraction in combination with high performance liquid chromatography (HPLC). Possible impact parameters such as sample pH, extraction and disperser solvents, salting-out effect, and extraction time were investigated. The experimental results indicated that proposed method possessed an excellent analytical performance, The linear range, detection limit, and precision (R.S.D.) were 0.1- 50 ng mL- 1 (R2 = 0.9955), 0.601 ng mL- 1 and 6,4%, respectively. The proposed method was validated with the real water samples, and the spiked recoveries were in the range of 69.9-89.8%, respectively. These results indicated that the established method with high enrichment factor, short extraction time was an excellent alternative for the routine analysis of atrazine in environmental samples. 2007 Qing Xiang Zhou. Published by Elsevier B.V. on behalf of Chinese Chemical Society. All rights reserved.  相似文献   

14.
A multiresidue method has been developed and validated for the simultaneous determination of organophosphorus insecticides and their toxic metabolites in sugarcane juice and refined sugar by gas chromatography with flame photometric detection. Limits of quantification of the method varied between 0.007 and 0.01 μg/g. Ethyl acetate based extraction followed by dispersive solid‐phase extraction cleanup with primary secondary amine yielded internationally acceptable recoveries of acephate, chlorpyrifos, dichlorvos, monocrotophos, malathion, malaoxon, phorate, phorate‐sulfoxide, phorate‐oxon, phorate‐sulfone, and quinalphos from selected matrices. The recoveries of target analytes from cane juice were 75.55 ± 0.5–102.57 ± 4.2, 77.45 ± 4.7–103.33 ± 3.3, and 80.55 ± 6.6–105.82 ± 9.8% at 0.01, 0.02, and 0.1 μg/g levels of fortification, respectively. The recoveries from cane sugar were 73.24 ± 3.5–104.47 ± 1.9, 75.23 ± 1.5–116.10 ± 3.7, and 70.75 ± 5.7–110.15 ± 2.7%, respectively at 0.01, 0.02, and 0.1 μg/g levels of fortification. Matrix effect and measurement uncertainty were within the permissible limit (less than 20%) as prescribed for pesticide residue analysis.  相似文献   

15.
建立了一种以液相微萃取(Liquid Phase Microextraction,LPME)与气相色谱-氢火焰(LPME-GC-FID)联用技术为基础的测定尿样中氨基比林、安替比林和巴比妥的方法。考察了萃取溶剂、萃取时间、pH对萃取效果的影响。氨基比林、安替比林、巴比妥线性范围分别为1.67~333、133~667、60~300 mg/L,检出限分别为1、4、12 mg/L。  相似文献   

16.
Polyol‐enhanced dispersive liquid–liquid microextraction has been proposed for the extraction and preconcentration of some organophosphorus pesticides from different samples. In the present study, a high volume of an aqueous phase containing a polyol (sorbitol) is prepared and then a disperser solvent along with an extraction solvent is rapidly injected into it. Sorbitol showed the best results and it was more effective on the extraction recoveries of the analytes than inorganic salts such as sodium chloride, potassium chloride, and sodium sulfate. Under the optimum extraction conditions, the method showed low limits of detection and quantification within the ranges of 12–56 and 44–162 pg/mL, respectively. Enrichment factors and extraction recoveries were in the ranges of 2799–3033 and 84–92%, respectively. The method precision was evaluated at a concentration of 10 ng/mL of each analyte, and relative standard deviations were found to be less than 5.9% for intraday (n = 6) and less than 7.8% for interday (n = 4). Finally, some aqueous samples were successfully analyzed using the proposed method and four analytes (diazinon, dimethoate, chlorpyrifos, and phosalone) were determined, some of them at ng/mL level.  相似文献   

17.
The molecular emission of heteroelements such as phosphorus and sulfur is the basis of the selective response of the flame photometric detector. The behavior of the FPD towards phosphorus compounds has been studied and design improvements sought with regard to burner configuration and temperature distribution. The possibility of differentiating between compounds containing phosphorus atoms and those containing both phosphorus and sulfur atoms has also been examined. Detection limits and response characteristics have been reported for organophosphorus pesticide residues in samples of natural origin  相似文献   

18.
A novel method based on simultaneous liquid-liquid microextraction and carbon nanotube reinforced hollow fiber microporous membrane solid-liquid phase microextraction has been developed for the determination of six organophosphorus pesticides, i.e. isocarbophos, phosmet, parathion-methyl, triazophos, fonofos and phoxim, in water and watermelon samples prior to high-performance liquid chromatography (HPLC). Under the optimum conditions, the method shows a good linearity within a range of 1-200 ng/mL for water samples and 5-200 ng/g for watermelon samples, with the correlation coefficients (r) varying from 0.9990 to 0.9997 and 0.9986 to 0.9995, respectively. The limits of detection (LODs) were in the range between 0.1 and 0.3 ng/mL for water samples and between 1.0 and 1.5 ng/g for watermelon samples. The recoveries of the method at spiking levels of 5.0 and 50.0 ng/mL for water samples were between 85.4 and 100.8%, and at spiking levels of 5.0 and 50.0 ng/g for watermelon samples, they were between 82.6 and 92.4%, with the relative standard deviations (RSDs) varying from 4.5-6.9% and 5.2-7.4%, respectively. The results suggested that the developed method represents a simple, low-cost, high analytes preconcentration and excellent sample cleanup procedure for the determination of organophosphorus pesticides in water and watermelon samples.  相似文献   

19.
A method based on solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC/MS) for the determination of 18 organophosphorus pesticides (OPPs) in textiles is described. Commercially available SPME fibers, 100 μm PDMS and 85 μm PA, were compared and 85 μm PA exhibited better performance to the OPPs. Various parameters affecting SPME, including extraction and desorption time, extraction temperature, salinity and pH, were studied. The optimized conditions were: 35 min extraction at 25 °C, 5% NaSO4 content, pH 7.0, and 3.5 min desorption in GC injector port at 250 °C. The linear ranges of the SPME-GC/MS method were 0.1-500 μg L−1 for most of the OPPs. The limits of detection (LODs) ranged from 0.01 μg L−1 (for bromophos-ethyl) to 55 μg L−1 (for azinphos-methyl) and the RSDs were between 0.66% and 9.22%. The optimized method was then used to analyze 18 OPPs in textile sample, and the determined recoveries were ranged from 76.7% to 126.8%. Moreover, the distribution coefficients of the OPPs between 85 μm PA fiber and simulative sweat solution (Kpa/s) were determined. The determined Kpa/s of the OPPs correlated well with their octanol-water partition coefficients (r = 0.764 and 0.678) and water solubility (= −0.892 and −0.863).  相似文献   

20.
Two-dimensional gas chromatography with two capillary columns of different polarity (SP 2100 and OV 225) is used for pesticide residue analysis in food samples. By means of “live chromatography” applying pneumatic switching technique according to Deans, unequivocal identification of 57 organophosphorus pesticides in food samples is achieved at trace concentrations. The instrument is equipped with only one injection port and one flame photometric detector. On-line data processing is very helpful, especially in calibration and checking the system's reliability with the multitude of test compounds. The complete pesticide residue analysis including clean-up of about six food samples can be completed by one person in 8 hours.  相似文献   