首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
An electrolytic hydride generation system for determination of another hydride forming element, cadmium, by catholyte variation electrochemical hydride generation (EcHG) atomic absorption spectrometry is described. A laboratory-made electrolytic cell with lead-tin alloy as cathode material is designed as electrolytic generator of molecular hydride. The influences of several parameters on the analytical signal have been evaluated using a Plackett-Burman experimental design. The significant parameters such as cathode surface area, electrolytic current, carrier gas flow rate and catholyte concentration have been optimized using univariate method. The analytical figures of merit of procedure developed were determined. The calibration curve was linear up to 20 ng ml−1of cadmium. The concentration detection limit (3σ, n = 8) of 0.2 ng ml−1 and repeatability (relative standard deviation, n = 7) of 3.1% were achieved at 10.0 ng ml−1. It was shown that interferences from major constituents at high concentrations were significant. The accuracy of method was verified using a real sample (spiked tap water) by standard addition calibration technique. Recovery of 104% was achieved for Cd in the spiked tap water sample.  相似文献   

2.
The analytical performance of a miniature quartz trap coupled with electrochemical hydride generator for antimony determination is described. A portion of the inlet arm of the conventional quartz tube atomizer was used as an integrated trap medium for on-line preconcentration of electrochemically generated hydrides. This configuration minimizes transfer lines and connections. A thin-layer of electrochemical flow through cell was constructed. Lead and platinum foils were employed as cathode and anode materials, respectively. Experimental operation conditions for hydride generation as well as the collection and revolatilization conditions for the generated hydrides in the inlet arm of the quartz tube atomizer were optimized. Interferences of copper, nickel, iron, cobalt, arsenic, selenium, lead and tin were examined both with and without the trap. 3σ limit of detection was estimated as 0.053 μg l− 1 for a sample size of 6.0 ml collected in 120 s. The trap has provided 18 fold sensitivity improvement as compared to electrochemical hydride generation alone. The accuracy of the proposed technique was evaluated with two standard reference materials; Trace Metals in Drinking Water, Cat # CRM-TMDW and Metals on Soil/Sediment #4, IRM-008.  相似文献   

3.
采用HNO3/HClO4(体积比10∶1)消解冶金废水样品,经6mol.L-1 HCl溶液酸化后,加入碘化钾(3%)、抗坏血酸(1%)及硫脲(1%)混合溶液进行还原,用氢化物-原子吸收光谱法(HG-AAS)测定了样品中的As含量.结果表明,该方法的检出限为0.297μg/L,相对标准偏差RSD为5.463%,样品加标回收率为93%~108%;其操作方便、选择性好、灵敏度高、干扰少,适合于复杂废水中微量和痕量As的测定.  相似文献   

4.
A novel method for speciation analysis of inorganic arsenic was developed by on-line hyphenating microchip capillary electrophoresis (chip-CE) with hydride generation atomic fluorescence spectrometry (HG-AFS). Baseline separation of As(III) and As(V) was achieved within 54 s by the chip-CE in a 90 mm long channel at 2500 V using a mixture of 25 mmol l(-1) H3BO3 and 0.4 mmol l(-1) CTAB (pH 8.9) as electrolyte buffer. The precisions (RSD, n=5) ranged from 1.9 to 1.4% for migration time, 2.1 to 2.7% for peak area, and 1.8 to 2.3% for peak height for the two arsenic species at 3.0 mg l(-1) (as As) level. The detection limits (3sigma) for As(III) and As(V) based on peak height measurement were 76 and 112 microg l(-1) (as As), respectively. The recoveries of the spikes (1 mg l(-1) (as As) of As(III) and As(V)) in four locally collected water samples ranged from 93.7 to 106%.  相似文献   

5.
Flow injection — microwave oven — hydride generation — atomic absorption spectroscopy (FI-MO-HG-AAS) has been optimized for the determination of the total and toxic arsenic in urine with and without persulfate, respectively. With microwave oven assisted digestion of urine with 5% (w/v) K2S2O8 and 5% (w/v) NaOH all arsenicals completely can be converted to arsenate, which is determined by HG-AAS to give the total concentration of the six species present in urine. The detection limits of 4–6 g l–1, the relative standard deviation of 3–7% and the high sample throughput make the methods suitable for rapid routine on-line determination. Application of the proposed procedures to the analysis of urine from people on a diet rich in seafood revealed a significant increase in total urinary arsenic due to the rapid excretion of organoarsenicals. Efficient decomposition and quantitative recovery of all arsenic species in spiked urine is achieved by using 5% K2S2O8 in 5% NaOH at 4.6 ml min–1, microwave power of 700 W and a 1.5 m coil.  相似文献   

6.
A simple procedure was developed for the direct determination of As(III) and As(V) in water samples by flow injection hydride generation atomic absorption spectrometry (FI–HG–AAS), without pre-reduction of As(V). The flow injection system was operated in the merging zones configuration, where sample and NaBH4 are simultaneously injected into two carrier streams, HCl and H2O, respectively. Sample and reagent injected volumes were of 250 μl and flow rate of 3.6 ml min−1 for hydrochloric acid and de-ionised water. The NaBH4 concentration was maintained at 0.1% (w/v), it would be possible to perform arsine selective generation from As(III) and on-line arsine generation with 3.0% (w/v) NaBH4 to obtain total arsenic concentration. As(V) was calculated as the difference between total As and As(III). Both procedures were tolerant to potential interference. So, interference such as Fe(III), Cu(II), Ni(II), Sb(III), Sn(II) and Se(IV) could, at an As(III) level of 0.1 mg l−1, be tolerated at a weight excess of 5000, 5000, 500, 100, 10 and 5 times, respectively. With the proposed procedure, detection limits of 0.3 ng ml−1 for As(III) and 0.5 ng ml−1 for As(V) were achieved. The relative standard deviations were of 2.3% for 0.1 mg l−1 As(III) and 2.0% for 0.1 mg l−1 As(V). A sampling rate of about 120 determinations per hour was achieved, requiring 30 ml of NaBH4 and waste generation in order of 450 ml. The method was shown to be satisfactory for determination of traces arsenic in water samples. The assay of a certified drinking water sample was 81.7±1.7 μg l−1 (certified value 80.0±0.5 μg l−1).  相似文献   

7.
The capabilities and limitations of the continuous flow injection hydride generation technique, coupled to atomic absorption spectrometry, for the speciation of major antimony species in seawater, were investigated. Two pre-concentration techniques were examined. After continuous flow injection hydride generation and collection onto a graphite tube coated with iridium, antimony was determined by graphite furnace atomic absorption spectrometry. The low detection limits obtained (∼5 ng l−1 for Sb(III) and ∼10 ng l−1 for Sb(V) for 2.5 ml seawater samples) permitted the determination of Sb(III) and total antimony in seawater with the use of selective hydride generation and on-line UV photooxidation. The number of samples that can be analyzed is about 15 per hour for Sb(III) determinations and 10 per hour for total antimony determinations. The analysis of seawater samples showed that Sb(V) was the predominant species, even in the presence of important biological activity.  相似文献   

8.
采用三毛细管微型在线氢化发生技术和装置, 建立了氢化物发生-电热石英管原子吸收法测定纺织品中痕量As、 Sb的分析方法. 研究了共存离子对As、 Sb检测的干扰及消除方法. 结果表明: 该方法除Co、 Sn对As和Ni对Sb有干扰外, 其它干扰元素允许量都较大. 采用酒石酸和KI混合掩蔽剂可抑制Co、 Sn对As和Ni对 Sb的干扰. As和Sb的检出限分别为0.7和0.4 ng/L, 已用于测定纺织品中痕量As和Sb的分析.  相似文献   

9.
An electrochemical hydride generation system was developed for the detection of Te by coupling an electrochemical hydride generator with atomic fluorescence spectrometry. Since TeH2 is unstable and easily decomposes in solution, a reticular W filament cathode was used in the present system. The TeH2 generated on the cathode surface was effectively driven out by sweeping gas from the cathode chamber. In addition, a low temperature electrochemical cell (10 °C) was applied to reduce the decomposition of TeH2 in solution. The limit of detection (LOD) was 2.2 ng ml− 1 and the relative standard deviation (RSD) was 3.9% for nine consecutive measurements of standard solution. This method was successfully employed for determination of Te in soldering tin material.  相似文献   

10.
An integrated electrochemical hydride generation cell, mainly composed of three components (a gas liquid separator, a graphite tube cathode and a reticulate Pt wire anode), was laboratory constructed and employed for the detection of arsenic by coupling to atomic fluorescence spectrometry. This integrated cell was free of ion-exchange membrane and individual anolyte, with the virtues of low-cost, easy assembly and environmental-friendly. Using flow injection mode, the sample throughput could come to 120 h−1 attributed to the small dimension of the cathode chamber. The operating conditions for the electrochemical hydride generation of arsenic were investigated in detail and the potential interferences from oxygen or various ions were also evaluated. Under the optimized conditions, no obvious oxygen quenching effects were observed. The limit of detection of As (III) for the sample blank solution was 0.2 ng mL−1 (3σ) and the relative standard deviation was 3.1% for nine consecutive measurements of 5 ng mL−1 As (III) standard solution. The calibration curve was linear up to 100 ng mL−1. The accuracy of the method was verified by the determination of arsenic in the reference materials GBW08517 (Laminaria Japonica Aresch) and GBW10023 (Porphyra crispata) and the developed method was successfully applied to determine trace amounts of arsenic in edible seaweeds.  相似文献   

11.
Electrochemical hydride generation (EC-HG) has been proposed as a valid alternative to chemical generation as a sample-introduction technique in atomic spectrometry. In this review fundamental aspects of the technique are revised, including designs of electrolytic cells, mechanisms of the generation process, and interferences caused by the presence of different species. Special attention is paid to the role of the configuration of the cathodes and their materials on the efficiency of hydride generation and on interferences from concomitant species. An overview of the application of EC-HG to the analysis of real samples is also given.  相似文献   

12.
Electrochemical hydride generation of thallium   总被引:1,自引:0,他引:1  
An electrochemical hydride generation (ECHG) technique was developed to improve the determination of thallium by atomic spectrometry. The technique is based on the catholyte variation system for production of thallium hydride. Using Pb-Sn alloy as cathode, a transient peak shaped signal was achieved and its height, the maximum absorbance value, was taken as an analytical parameter. Parameters that might affect the hydride generation efficiency were investigated and the analytical performance of the method under the optimized experimental conditions was assessed. The linear range was 1-250 ng mL−1 for thallium and the relative standard deviation of the method was 4.2% (RSD, n = 7). The LOD for thallium was found to be 0.8 ng mL−1, showing a significant improvement relative to conventional chemical hydride generation techniques. The proposed method was applied to the determination of thallium in unalloyed zinc standard reference material. This method offers high sensitivity, simplicity, rapidness, freeness from reagent and low acid consumption.  相似文献   

13.
Five closed-vessel microwave digestion methods were compared for the accurate determination of arsenic and selenium in NIST SRM 1645 River Sediment by flow-injection hydride-generation atomic absorption spectrometric methods. The digestion methods using five different acid mixtures (HNO3/ H2SO4, HNO3/HCl04, HNO3/HCl, HNO3/HCl/HF, HNO3/H2SO4/HClO4) were all found to be reliable for the determination of the analytes. Taking into consideration the safety and suitability for the analysis of other metals, the methods based on the use ofaqua regia are recommended for closed vessel microwave digestion with pressure control. Using the quick digestion program, the presence of up to 10% organic content in soil samples did not adversely affect the closed vessel digestion and did not cause the loss of volatile analytes. After digestion, opening the vessel under an inner pressure of below 345 kPa (50 psi) had no effect on the accuracy of the results. The recommended digestion methods (HNO3/HCl and HNO3/ HCl/HF) for the reliable determination of arsenic and selenium in different sediment samples were demonstrated. The calculated detection limits (3 b ) were less than 0.030 g/g and 0.033 g/g for arsenic and selenium, respectively. All analytical results for arsenic and selenium in SRM 1645 River sediment, NRCC BCSS-1 Marine Sediment and NIES CRM Pond Sediment were within or near the certified and reported ranges, with the exception of selenium in NIES CRM No. 2 Pond Sediment.  相似文献   

14.
The interferences between arsenic and antimony on each other during the hydride generation atomic absorption spectrometry (HGAAS) determination of arsenic and antimony using a quartz tube atomizer (QTA) were examined. In order to eliminate or reduce such interferences by selective heat decomposition of arsine and stibine, a Pyrex adsorption U-tube trap containing glass wool was placed between the drying tube and the quartz tube atomizer. Although at 250 °C stibine decomposes and is held almost completely by the trap, arsine is also decomposed to an extent of 24% and, therefore, thermal decomposition is not useful to eliminate antimony interference on arsenic determination. The effect of coating the glass wool in the U-tube with antimony on the arsenic suppression of the antimony signal was studied. The results showed that the antimony coating in the U-tube could not hold arsenic effectively and its interference on the antimony signal could not be eliminated by this means. In the second part of the study, oxygen was supplied to the quartz tube atomizer during atomization in order to study the effect of supplying oxygen on the antimony signal and on the interference of arsenic in the antimony determination. Sensitivity was increased in the presence of oxygen and interferences of arsenic on antimony determination was decreased by about 10% when oxygen was supplied. It was also observed that the extent of interferences depended mainly on the interferent concentration rather than the analyte concentration.  相似文献   

15.
运用以聚苯胺修饰的石墨电极为阴极的电化学氢化物发生装置实现了锡元素的电化学氢化物发生.在电极表面聚合一层聚苯胺,能够有效地提高锡元素的电化学氢化物发生效率,通过与原子荧光光谱仪联用,成功地测定了食品中的锡含量.本工作对各种实验参数和干扰情况进行了详细研究.方法对锡的检出限为1.2 ng/mL(3σ);样品分析精密度(R...  相似文献   

16.
A novel analytical technique was developed where gaseous hydrogen selenide formed by sodium tetrahydroborate reduction is transported to and trapped on a resistively heated gold-coated W-coil atom trap for in situ preconcentration. Gold coating on W-coil was prepared by using an organic solution of Au. The atom trap is held at 165 °C during the collection stage and is heated up to 675 °C for revolatilization; analyte species formed are transported to an externally heated quartz T-tube where the atomization takes place and the transient signal is obtained. The carrier gas consisted of 112.5 ml min− 1 Ar with 75 ml min− 1 H2 during the collection step and 112.5 ml min− 1 Ar with 450 ml min− 1 H2 in the revolatilization step. The half width of the transient signal obtained is less than 0.5 s. The RSD for the measurements was found to be 3.9% (n = 11) for 0.10 µg l− 1 Se using peak height measurements.  相似文献   

17.
设计了一种新的电化学氢化物发生装置, 用于测定不同价态的硒. 通过对传统的平板电解池的改进, 设计了全新的圆盘电解池并采用螺纹密封的方式, 极大地缩短了电解池的装配时间, 提高了电解池的使用寿命和密封性能. 结合热水浴在线还原技术, 将 Se(Ⅵ)在高浓度HCl介质中120 s内还原成Se(Ⅳ), 通过电化学氢化物发生技术生成氢化物, 成功的进行硒的在线价态分析. 对各种实验参数进行了详细的研究, Se(Ⅳ) 和Se(Ⅵ)的相对标准偏差分别为2.6% 和 3.1% (n=11);Se(Ⅳ)和总硒的检出限分别为0.32和0.27 μg/L (3σ).  相似文献   

18.
Thallium hydride was generated from aqueous solutions by merging sample and sodium tetrahydroborate reductant in a batch system. In situ preconcentration of volatile thallium hydride in a preheated graphite furnace coated with palladium, which was used as both the collection medium and atomizer, greatly improved the sensitivity for the determination of thallium by hydride generation atomic absorption spectrometry. The presence of tellurium can increase the generation efficiency of thallium hydride. The operating conditions were optimized. The calibration graph is linear up to 100 ng and the characteristic mass for thallium was 0.92 ng which is seventeen times lower than that obtained with the heated quartz tube atomizer.  相似文献   

19.
Hydride generation atomic fluorescence spectrometry was for the first time utilized to determine trace toxic element arsenic in the skeleton fossils of four dinosaurs unearthed in Sichuan Province of China. The instrumental limit of detection (LOD) for arsenic was 0.03 μg/L under optimal experimental conditions, which compared favorably to that by ICP-AES and ETAAS. The samples were digested with aqua regia in boiling water bath. The recoveries of standard addition were found to be from 97 to 109%, and the analytical results were found in good agreement with those by ICP-AES. It is a simple, reliable, sensitive yet relatively inexpensive analytical method, compared to ICP-AES, ICP-MS or ETAAS. Interesting analytical results were found that the arsenic concentrations were all abnormally high in the skeleton fossils. The established analytical method and the analytical results may be helpful in revealing the mystery of the mass extinction of the dinosaur fauna. The analytical results, together with other data available to date, supported the argument that the arsenic toxicosis could be a contributing factor for the mass extinction of the dinosaur fauna in Sichuan Province of China.  相似文献   

20.
Modular L-design of hydride atomizers for atomic absorption spectrometry   总被引:1,自引:0,他引:1  
A novel modular L-shaped design of hydride atomizer for atomic absorption spectrometry is described. It makes it possible to replace the optical tube of the atomizer and, mainly, to employ optical tubes made also from other materials than fused quartz. The design is useful mainly for further improvement of hydride atomizers based on the multiatomizer concept. Employing selenium hydride as the analyte and arsine as the interferent, a preliminary evaluation of performance of three types of L-shaped multiatomizers based on various optical tubes in terms of sensitivity, linearity of calibration graph and resistance to atomization interferences is made. The “classical” T-shaped multiatomizer was employed as a reference.The L-shaped multiatomizer with the optical tube analogous to that employed in the “classical” T-shaped multiatomizer offers virtually the same performance as the reference multiatomizer. Optical tube made of fused quartz with holes with smaller diameters does not offer significantly better performance compared to the reference T-shaped multiatomizer. However, the L-shaped multiatomizer with optical tube fabricated from porous quartz glass overpowers all the other multiatomizers substantially in terms of the resistance against interferences: even the maximum As interferent concentration of 5 µg ml− 1 does not significantly influence the observed signal. This should be compared with multiatomizers based on plain fused quartz tubes with holes: tolerance limit around 0.5 µg ml− 1; interferent concentration of 1 µg ml− 1 causing 20% signal depression.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号