首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 500 毫秒
1.
自Small等首次采用双柱阴离子色谱法测定无机阴离子以来,单柱阴离子色谱法已被用于测定无机阴离子、有机酸,并利用金属阳离子与EDTA形成的阴离子配合物分离测定阳离子。但用单柱阴离子色谱法同时测定无机阴离子、无机阳离子和有机酸尚未见报道。本文采用EDTA为淋洗液的单柱阴离子色谱法研究了无机阴离子、无机阳离子和有机酸的同时分析测定。  相似文献   

2.
Methyl-capped poly(ethylene oxide) moieties were chemically bonded to silica gel using an amine-reactive modification reagent and evaluated as the stationary phase for ion chromatography. In this work, primary amino groups of an aminopropylsilica packing material were reacted with methyl-PEO12-NHS ester (succinimidyl-{[N-methyl]-dodecaethyleneglycol} ester) in phosphate buffer (pH 7.0) at room temperature. The prepared poly(ethylene oxide)-bonded stationary was evaluated for the separation of inorganic anions, and the retention behavior of inorganic anions on the prepared stationary phase was examined. The elution order of the investigated anions was the same as that observed in common ion chromatography. Both cations and anions of the eluent affected the retention of the analyte anions. Ion exchange was involved for the retention of analyte anions, although the present stationary phase does not possess any discrete ion-exchange sites. The stationary phase was applied to the separation of trace anions contained in tap water and a rock salt.  相似文献   

3.
The ion-exchange separation of organic anions of varying molecular mass has been demonstrated using ion chromatography with isocratic, gradient and multi-step eluent profiles on commercially available columns with UV detection. A retention model derived previously for inorganic ions and based solely on electrostatic interactions between the analytes and the stationary phase was applied. This model was found to accurately describe the observed elution of all the anions under isocratic, gradient and multi-step eluent conditions. Hydrophobic interactions, although likely to be present to varying degrees, did not limit the applicability of the ion-exchange retention model. Various instrumental configurations were investigated to overcome problems associated with the use of organic modifiers in the eluent which caused compatibility issues with the electrolytically derived, and subsequently suppressed, eluent. The preferred configuration allowed the organic modifier stream to bypass the eluent generator, followed by subsequent mixing before entering the injection valve and column. Accurate elution prediction was achieved even when using 5-step eluent profiles with errors in retention time generally being less than 1% relative standard deviation (RSD) and all being less than 5% RSD. Peak widths for linear gradient separations were also modelled and showed good agreement with experimentally determined values.  相似文献   

4.
The present article reviews the use of polyethylene glycol (PEG) or polyoxyethylene (POE) as the stationary phase for the separation of inorganic anions in ion chromatography and discusses about the retention mechanisms involved in the separation of anions on the novel stationary phases. PEG permanently coated on a hydrophobic stationary phase retained anions in the partition mode and allowed us to use high-concentration eluents because the retention of anions increased with increasing eluent concentration for most of the eluents. This situation was convenient to determine trace anions contained in seawater samples without any disturbance due to matrices. Chemically bonded POE stationary phases retained not only anions but also cations. Anions were retained in the ion-exchange mode, although POE chains possess no ion exchange sites. The retention behavior suggested that eluent cations could be trapped among multiple POE chains via ion-dipole interaction, and that the trapped cations worked as the anion-exchange sites. Anions could be separated using crown ether, i.e., cyclic POE, as the eluent additive with a hydrophobic stationary phase, where analyte anions were retained via electrostatic interaction with the eluent cation trapped on the crown ether.  相似文献   

5.
Guo H  Chu C  Li Y  Yang B  Liang X 《The Analyst》2011,136(24):5302-5307
Ion chromatography (IC) is one of the most powerful analysis technologies for the determination of charged compounds. A novel click lysine stationary phase was prepared via Cu(I) catalyzed alkyne-azide 1,3-dipolar cycloaddition (CuAAC) and applied to the analysis of inorganic ions. The chromatographic evaluation demonstrated good performance (e.g. the plate number of thiocyanate is ~50,000 plates m(-1)) and effective separation ability for the common inorganic anions with aqueous Na(2)SO(4) eluent. The separation mechanism was observed to be mainly dominated by ion exchange interaction. The retention of these analytes is highly dependent on the pH value of eluent. Compared with the lysine stationary phase prepared via the conventional manner, the click lysine exchanger demonstrated shorter retention time and better ion separation characteristics under the same chromatographic conditions, which is a great advantage for rapid separation and analysis of inorganic ions.  相似文献   

6.
This work focuses on problems regarding empirical retention modelling and optimization of separation in ion chromatography. Influences of eluent flow rate and concentration of eluent competing ion (OH) on separation of seven inorganic anions (fluoride, chloride, nitrite, sulphate, bromide, nitrate, and phosphate) were investigated. Artificial neural networks and multiple linear regression retention models in combination with several criteria functions were used and compared in global optimization process. It can be seen that general recommendations for optimization of separation in ion chromatography is application of chromatography exponential function criterion in combination with artificial neural networks retention model.  相似文献   

7.
A two-dimensional ion chromatography (2D-IC) approach has been developed which provides greater resolution of complex samples than is possible currently using a single column. Two columns containing different stationary phases are connected via a tee-piece, which enables an additional eluent flow and independent control of eluent concentration on each column. The resultant mixed eluent flow at the tee-piece can be varied to produce a different eluent concentration on the second column. This allows analytes strongly retained on the first column to be separated rapidly on the second column, whilst maintaining a highly efficient, well resolved separation of analytes retained weakly on the first column. A group of 18 inorganic anions has been separated to demonstrate the utility of this approach and the proposed 2D-IC method provided separation of this mixture with resolution of all analytes greater than 1.3. Careful optimisation of the eluent profiles on both columns resulted in run times of less than 28 min, including re-equilibration. Separations were performed using isocratic or gradient elution on the first column, with an isocratic separation being used on the second column. Switching of the analytes onto the second column was performed using a gradient pulse of concentrated eluent to quickly elute strongly retained analytes from the first column onto the second column. The separations were highly repeatable (RSD of 0.01–0.12% for retention times and 0.08–2.9% for peak areas) and efficient (typically 8000–260,000 plates). Detection limits were 3–80 ppb.  相似文献   

8.
A vitamin U-bonded stationary phase was prepared and the retention behavior of inorganic anions was examined using ion chromatography. Inorganic anions were retained on the vitamin U-bonded stationary phase under acidic as well as neutral eluent conditions in the ion-exchange mode. The elution order of the examined anions under neutral eluent conditions was nearly the same as that observed in common ion exchange mode, while the elution order observed under acidic eluent conditions was completely different from that observed in common ion exchange mode. The retention of the analyte anions under the neutral eluent conditions was due to the sulfonium groups of the vitamin U, while protonated primary amino groups caused retention of the analyte anions with different selectivity under acidic conditions. The retention factor of the analyte anions increased with decreasing eluent concentration under both eluent conditions. The present system was applied to the determination of bromide and nitrate contained in seawater.  相似文献   

9.
In this work, three different methods for modeling of gradient retention were combined with several optimization objective functions in order to find the most appropriate combination to be applied in ion chromatography method development. The system studied was a set of seven inorganic anions (fluoride, chloride, nitrite, sulfate, bromide, nitrate, and phosphate) with a KOH eluent. The retention modeling methods tested were multilayer perceptron artificial neural network (MLP-ANN), radial-basis function artificial neural network (RBF-ANN), and retention model based on transfer of data from isocratic to gradient elution mode. It was shown that MLP retention model in combination with the objective function based on normalized retention difference product was the most adequate tool for optimization purposes.  相似文献   

10.
研究了用硅胶整体柱和直接电导检测的离子相互作用色谱快速分析常见无机阴离子的方法。实验采用氢氧化四丁铵和邻苯二甲酸为淋洗液,讨论了包括淋洗液浓度、流速和pH对分离的影响。当以1.5 mmol/L氢氧化四丁铵和1.1 mmol/L邻苯二甲酸为淋洗液(pH 5.5),流速6 mL/min时,可以在1 min内分离Cl-、NO2-、Br-、NO3-、ClO3-、SO42-和I-7种阴离子。方法的检出限为0.3~1.9 mg/L,峰面积、峰高的相对标准偏差(RSD,n=5)分别为0.4%~2.2%和0.1%~1.5%。将该法用于测定矿泉水和地下水中的阴离子,加标回收率在97.9%~100.3%之间。  相似文献   

11.
Methods for separation of ions by ion-exchange, ion-pair, and zwitterion ion chromatography share at least one common thread--the induced formation of a cation-anion pair in the stationary phase. Selectivity can be defined as the relative ability of sample ions to form such a pair. Examples are given in anion-exchange chromatography to show the effect of variations in the geometry, bulkiness and polarity of the resin cation on selectivity. The type of resin matrix, the hydrophobic nature of the resin surface and the degree of solvation also affect chromatographic behavior. The selectivity series observed in ion chromatography seems to be best explained by the interplay of two components: electrostatic attraction (ES) and the enforced-pairing (EP) that is brought about by hydrophobic attraction and by water-enforced ion pairing. Selectivity in ion-pair chromatography (IPC) and in zwitterion ion chromatography (ZIC) is affected by both the mobile phase cation and anion. This leads to elution orders for anions that are different from conventional ion-exchange chromatography (IC) of anions where cations are excluded from the stationary phase and have little effect on a separation. The elution order of anions in ZIC is similar to that in IC except for small anions of 2-charge, which are retained more weakly in ZIC. A unique advantage of ZIC is that sample ions can be eluted as ion pairs with pure water as the eluent and a conductivity detector. The mechanism for separation of anions on a zwitterionic stationary phase has been a subject for considerable debate. The available facts point strongly to a partitioning mechanism or a mixed mechanism in which partitioning is dominant with a weaker ion-exchange component.  相似文献   

12.
Short reversed-phase columns (50 mm x 4.6 mm Gemini C(18)) were dynamically coated with carboxybetaines of the general structure, C(12)H(25)N(+)(CH(3))(2)(CH(2))(n)COOH, namely (N-dodecyl-N,N-dimethylammonio)undecanoate, DDMAU (n=10) and (N-dodecyl-N,N-dimethylammonio)butyrate, DDMAB (n=3), and investigated for the separation of inorganic anions in ion chromatography. The role of the ionic strength of coating surfactant solutions on their adsorption and resultant column capacity was studied. The retention of inorganic anions was investigated with different eluents at various concentrations and pH. Interestingly, no retention for anions was found with pure water as the eluent, but the addition of small amounts of electrolytes, up to 0.1 mM, caused a sharp increase in the retention of analytes. The effect of increasing anion retention with an increase in eluent cation charge was also observed. Based on this effect a new cation charge gradient concept was proposed and applied to the separation of a standard mixture of anions.  相似文献   

13.
The mixed-mode separation of a selection of anionic and cationic pharmaceutically related compounds is studied using ion-exchange columns and eluents consisting of ionic salts (potassium hydroxide or methanesulfonic acid) and an organic modifier (methanol). All separations were performed using commercially available ion-exchange columns and an ion chromatography instrument modified to allow introduction of methanol into the eluent without introducing compatibility problems with the eluent generation system. Isocratic retention prediction was undertaken over the two-dimensional space defined by the concentration of the competing ion and the percentage of organic modifier in the eluent. Various empirical models describing the observed relationships between analyte retention and both the competing ion concentration and the percentage of methanol were evaluated, with the resultant model being capable of describing the separation, including peak width, over the entire experimental space based on six initial experiments. Average errors in retention time and peak width were less than 6% and 27%, respectively, for runs taken from both inside and outside of the experimental space. Separations performed under methanol gradient conditions (while holding the competing ion concentration constant) were also modelled. The observed effect on retention of varying the methanol composition differed between analytes with several analytes exhibiting increased retention with increased percentage methanol in the eluent. An empirical model was derived based on integration of the observed tR vs. %methanol plot for each analyte. A combination of the isocratic and gradient models allowed for the prediction of retention time using multi-step methanol gradient profiles with average errors in predicted retention times being less than 4% over 30 different 2- and 3-step gradient profiles for anions and less than 6% over 14 different 2- and 3-step gradient profiles for cations. A modified peak compression model was used to estimate peak widths under these conditions. This provided adequate width prediction with the average error between observed and predicted peak widths being less than 15% for 40 1-, 2- and 3-step gradients for anions and less than 13% over 14 1-, 2- and 3-step gradients for cations.  相似文献   

14.
An ion chromatography method for rapid and direct determination of iodide in seawater and edible salt is reported. Separation was achieved using a laboratory-made C30 packed column (100 mm x 0.32 mm i.d.) modified with poly(ethylene glycol) (PEG). Effects of eluent composition on retention behavior of inorganic anions have been investigated. Both cation and anion of the eluent affected the retention of analyte anions. The retention time of anions increased with increasing eluent concentration when lithium chloride, sodium chloride, potassium chloride, sodium sulfate, magnesium sulfate were used as the eluent, while it decreased with increasing eluent concentration when ammonium sulfate was used as the eluent. The detection limit for iodide obtained by injecting 0.2 microl of sample was 9 microg/l (S/N = 3). The present method was successfully applied to the rapid and direct determination of iodide in seawater and edible salt samples. Partition may be involved in the present separation mode.  相似文献   

15.
单一阴离子交换柱同时分离有机酸和无机阴阳离子   总被引:8,自引:0,他引:8  
丁明玉  陈培榕 《分析化学》1997,25(2):161-164
研究了用乙二胺四乙酸(EDTA)作淋洗液时,性质迥异的有机酸、无机阴离子和碱土金属离子(Ca^2+、Mg^2+)在同一阴离子交换柱上的同时分离以及保留机理,结果表明,在离子交换机理之外,非离子交换机理对有机酸及钙镁的EDTA络阴郭的保留行为起一定的辅助作用,9种有机酸和无机阴阳离子在10min内得到了较好的分离。各离子的电导检测灵敏度在10^-9至10^-11mol,能满足环境和食吕分析的要求。  相似文献   

16.
建立了离子色谱-直接电导检测同时测定三氟甲烷磺酸根,氟硼酸根及常见无机阴离子(F-,Cl-,Br-,NO3-,SO24-)的方法。实验采用Shim-pack IC-A3阴离子交换色谱柱,分别选用对羟基苯甲酸-三(羟甲基)氨基甲烷-硼酸,邻苯二甲酸-三(羟甲基)氨基甲烷,邻苯二甲酸氢钾为淋洗液,考察了淋洗液种类,浓度及色谱柱温度对分离测定三氟甲烷磺酸根,氟硼酸根及常见无机阴离子的影响。最佳色谱条件为:以1.2mmol/L邻苯二甲酸氢钾为淋洗液,柱温30℃,流速1.0mL/min。在此条件下,可同时基线分离7种阴离子,且色谱峰形对称。所测阴离子的检出限(S/N=3)为0.02~1.88mg/L,保留时间和峰面积的相对标准偏差(n=5)分别小于0.17%和2.05%。应用本方法测定离子液体中三氟甲烷磺酸根,氟硼酸根及常见无机阴离子,加标回收率在97.0%~102.8%之间。本方法简单,准确,可靠,具有较好的实用性。  相似文献   

17.
The preparation and evaluation of zirconium-adsorbing silica gel (Zr-Silica) as an ion-exchange stationary phase in ion chromatography for inorganic anions and cations was carried out. The Zr-Silica was prepared by the reaction of silanol groups on the surface of the silica gel with zirconium butoxide (Zr(OCH2CH2CH2CH3)4) in ethanol. The ion-exchange characteristics of the Zr-Silica were evaluated using 10 mM tartaric acid at pH 2.5 as eluent. The Zr-Silica was found to act as a cation-exchanger under the eluent conditions. The retention behavior of alkali and alkaline earth metal cations was then investigated. The Zr-Silica column was proved to be suitable for the simultaneous separation of alkali metal cations and ammonium ion. Excellent separation of the cations on a 15 cm Zr-Silica column was achieved in 25 min using 10 mM tartaric acid as eluent.  相似文献   

18.
Effects of eluent composition on retention behavior of inorganic anions have been investigated in ion chromatography using anion-exchangers modified with heparin. Both cation and anion of the eluent affected the retention of analyte anions and unusual retention behavior was observed on the modified stationary phase. The retention time of anions decreased with decreasing eluent concentration when sodium sulfate, magnesium sulfate and chlorides of alkali metals were used as the eluent, whereas it increased with decreasing eluent concentration when aluminum sulfate, copper sulfate and sulfuric acid were used as the eluent. The retention of nitrate increased in the order of Li+, Na+, K+, Rb+ and Cs+ when their chlorides were used as the eluent. When sodium perchlorate and chlorides of alkaline-earth metals were used as the eluent, the eluent should include heparin. Otherwise, the modifier was partially bled from the column.  相似文献   

19.
The aim of this work is the development of an artificial neural network model, which can be generalized and used in a variety of applications for retention modelling in ion chromatography. Influences of eluent flow-rate and concentration of eluent anion (OH-) on separation of seven inorganic anions (fluoride, chloride, nitrite, sulfate, bromide, nitrate, and phosphate) were investigated. Parallel prediction of retention times of seven inorganic anions by using one artificial neural network was applied. MATLAB Neural Networks ToolBox was not adequate for application to retention modelling in this particular case. Therefore the authors adopted it for retention modelling by programming in MATLAB metalanguage. The following routines were written; the division of experimental data set on training and test set; selection of data for training and test set; Dixon's outlier test; retraining procedure routine; calculations of relative error. A three-layer feed forward neural network trained with a Levenberg-Marquardt batch error back propagation algorithm has been used to model ion chromatographic retention mechanisms. The advantage of applied batch training methodology is the significant increase in speed of calculation of algorithms in comparison with delta rule training methodology. The technique of experimental data selection for training set was used allowing improvement of artificial neural network prediction power. Experimental design space was divided into 8-32 subspaces depending on number of experimental data points used for training set. The number of hidden layer nodes, the number of iteration steps and the number of experimental data points used for training set were optimized. This study presents the very fast (300 iteration steps) and very accurate (relative error of 0.88%) retention model, obtained by using a small amount of experimental data (16 experimental data points in training set). This indicates that the method of choice for retention modelling in ion chromatography is the artificial neural network.  相似文献   

20.
A new ion chromatographic (IC) system has been established by using micelles of 3-(N,N-dimethylmyristylammonio)propanesulfonate (Zwittergent 3-14) loaded onto a reversed-phase packed column as the separation column with an electronic rotary switching valve packed-bed suppressor for conductometric detection of inorganic anions. An aqueous H3BO3-Na2B4O7 solution has been demonstrated to be the most desirable eluent for this IC system. The relationship between retention time and the concentration of the borate eluent was determined for a series of model anionic analytes and this relationship was found to be opposite to that exhibited in a conventional anion-exchange IC system. The rapid elution and complete separation of monovalent inorganic anions were obtained by initially using a high-concentration borate solution as the eluent for a short-period, and then switching to a lower-concentration borate eluent to complete the separation. Detection limits for nitrite, bromide, nitrate, and chlorate were 0.85, 0.88, 0.95 and 4.8 microM, respectively, when a 7.0 mM Na2B4O7 eluent was used. Moreover, the ability to directly detect these monovalent anions in samples containing high concentrations of sulfate and/or chloride ions provided a major advantage of this approach.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号