共查询到20条相似文献,搜索用时 15 毫秒
1.
建立了硅胶G板上分离氟罗沙星(FLX)和司帕沙星(SPLX)并同时测定其在体液中含量的方法 ;用0.27mol·L -1、pH=7的EDTA溶液修饰硅胶G板 ,避免了试样与金属离子的络合作用 ;使用乙醇 -乙酸乙酯 -1,2_二氯乙烷 -10 %(φ)氨水(体积比4∶3∶2∶1)为展开剂 ,FLX和SPLX的Rf值分别为0.40和0.59 ;板上的荧光斑点 ,使用CS_9000双波长薄层色谱扫描仪以285nm为激发波长扫描 ,同板标准工作曲线法定量 ;线性范围分别为0.5~85ng(FLX)和0.5~100ng(SPLX) ,回收率为96 %~102 % ,相对标准偏差≤5.2 % ;该法用于血样与尿样测定 ,具有操作简单 ,灵敏、准确的特点 相似文献
2.
JPC – Journal of Planar Chromatography – Modern TLC - New, simple, rapid, and accurate thin-layer chromatographic methods have been established for determination of fluvoxamine and... 相似文献
3.
采用毛细管电泳高频电导法检测了司帕沙星。探讨了缓冲液的种类、浓度、添加剂以及操作电压和进样时间等因素对分离的影响。选择3.0mmol LHAc-5.0?H5OH(V V)为电泳介质,分离电压20.0kV,在4min内可实现司帕沙星的分离检测。在优化条件下,司帕沙星的线性范围为6 0~280 0μg mL,检出限为1 9μg mL。在该条件下,片剂中的敷料不干扰测定,可成功测定片剂中的司帕沙星,样品回收率为98.7%~101%。 相似文献
4.
Simultaneous determination of two antidiabetic drugs, metformin and glyburide, in pharmaceutical tablet formulations were investigated. Normal phase thin layer chromatography plate (silica gel 60 F 254) was used as stationary phase and water/methanol/ammonium sulfate (2/1/0.5 w/ v) as mobile phase to determine two pharmaceutically active ingredients, in three different formulations of Glucovance ®. This system gave a good resolution for metformin ( R f value of 0.43 ± 0.01) and glyburide ( R f value of 0.64 ± 0.02). Determination was by densitometry in the absorbance mode at 237 nm. The linear regression data for the calibration plot showed a good relationship with r = 0.99581 and 0.99982 for metformin and glyburide, respectively. The method was validated for precision and recovery. The limits of detection and quantification were 25.24 and 84.12 ng spot ?1 for metformin and 12.26 and 40.86 ng spot ?1 for glyburide, respectively. Stability study has been carried out for samples and standard solutions. 相似文献
5.
A new, simple high-performance thin-layer chromatographic method has been established and validated for simultaneous determination
of escitalopram oxalate and clonazepam in a combined tablet dosage form. The drugs were separated on aluminum plates precoated
with silica gel 60 F 254; toluene–ethyl acetate–triethylamine 7:3.5:3 ( v/ v) was used as mobile phase. Quantitative analysis was performed by densitometric scanning at 258 nm. The method was validated
for linearity, accuracy, precision, and robustness. The calibration plot was linear over the ranges 250–2,500 and 50–500 ng band −1 for escitalopram oxalate and clonazepam, respectively. The method was successfully applied to the analysis of drugs in a
pharmaceutical formulation. 相似文献
6.
A gas Chromatographic method has been established for analysis of Cinoxacin in crystalline powder. The method is based on chemicaI derivatization of Cinoxacin as its methyl ester, and n-octacosane is used as an internal standard. Gas chromatographic analysis was proceeded on a glass column packed with 2% OV-1 on Chromosorb W. Quantitation is feasible by measurements of peak area ratios. The method proves to be simple, rapid and accurate. 相似文献
7.
JPC – Journal of Planar Chromatography – Modern TLC - A new, simple, and rapid high-performance thin layer chromato-graphic method coupled with densitometry has been developed and... 相似文献
8.
JPC – Journal of Planar Chromatography – Modern TLC - A new, accurate, rapid TLC method has been established for determination of timolol maleate (Timohexal 0.1%, Timoptic 0.25%) and... 相似文献
9.
应用线性扫描伏安法和循环伏安法研究氟罗沙星在玻碳电极上的电化学行为。在含有铜离子的pH 6.5的0.10mol.L-1磷酸盐缓冲溶液中,铜离子在玻碳电极上分别于-0.136V和-0.728V处形成两个还原峰,加入氟罗沙星后铜离子的还原峰电位不变但峰电流均降低。在优化的试验条件下,于-0.136V处的峰电流降低值Δip与氟罗沙星浓度在6.40×10-7~1.5×10-4 mol.L-1范围内呈线性关系,检出限为2.10×10-7 mol.L-1。方法用于氟罗沙星片剂中氟罗沙星含量的测定,回收率在96.8%~103.5%之间。 相似文献
10.
JPC – Journal of Planar Chromatography – Modern TLC - A simple, precise, accurate, and rapid HPTLC method for quantitative analysis of venlafaxine hydrochloride in the tablet dosage... 相似文献
11.
High performance liquid chromatography has been the most popular choice for the determination of atorvastatin. In this study, two-step isocratic chromatography on silica gel 60F254 HPTLC layer and densitometric quantitation at λ = 280 nm was developed for the separation of atorvastatin from plasma constituencies and sodium diclofenac as peak-tracer. The established HPTLC method was validated in terms of LOD/LOQ, linearity, recovery and repeatability. The calibration function of the analyte was linear in the range 101–353.5 ng zone ?1 and the correlation coefficient was 0.9969. The limits of detection and quantitation were 30.3 and 101 ng zone ?1. The recovery and relative standard deviation obtained from between-days analysis were 97.5–103.0 and 1.7–3.4%. 相似文献
12.
Fleroxacin is a third generation fluoroquinolone with broad spectrum antibacterial activity. In this work an LC-DAD method for the analysis of fleroxacin was developed and validated using UV detection at 286 nm. The method was validated for linearity, precision, robustness, LOD, LOQ, specificity and accuracy at concentrations of 0.2–20.0 μg mL−1 and r
2 = 1. The LOD and LOQ were 0.059 and 0.197 μg, respectively, the recoveries were 99.92–102.0% and the CV was less than 2.0%. The LC-DAD validated method provided analytical sensitivity, specificity and reproducibility suitable for quality control analysis. 相似文献
13.
司帕沙星是一类喹诺柄类抗菌药物,该文采用反相高效液相色谱法对其生产进行质控分析,测定中选用C18柱,以甲醇-水(内含40mmol.L^-1的磷酸二氢钾和30mmol.L^-1的四乙基溴化铵,V甲醇:V水=45:55)为流动相,于298nm进行检测,样品测定的回收率为97.9%~100.2%,相对标准偏差不大于2%。 相似文献
14.
JPC – Journal of Planar Chromatography – Modern TLC - New simple TLC methods with densitometry and videoscanning have been developed for the quantitation of bezafibrate in Bezamidin... 相似文献
15.
JPC – Journal of Planar Chromatography – Modern TLC - Two new, simple, rapid, and accurate thin-layer chromatographic methods have been developed for determination of fluoxetine in... 相似文献
16.
An HPTLC method has been developed that coelutes both the isomers of cefpodoxime proxetil (CFP). CFP was chromatographed on a silica gel 60 F254 TLC plate using toluene:acetonitrile (6:4) as a mobile phase and was quantified at 234 nm. The method was validated with respect to linearity, accuracy, precision and specificity. The limit of detection and limit of quantification for CFP were found to be 0.150 and 0.4 μg spot−1, respectively. The proposed method was successfully used to determine the amount of CFP present in the marketed tablets and self-nanoemulsifying systems. 相似文献
17.
Fleroxacin is a third generation fluoroquinolone with broad spectrum antibacterial activity. In this work an LC-DAD method
for the analysis of fleroxacin was developed and validated using UV detection at 286 nm. The method was validated for linearity,
precision, robustness, LOD, LOQ, specificity and accuracy at concentrations of 0.2–20.0 μg mL −1 and r
2 = 1. The LOD and LOQ were 0.059 and 0.197 μg, respectively, the recoveries were 99.92–102.0% and the CV was less than 2.0%.
The LC-DAD validated method provided analytical sensitivity, specificity and reproducibility suitable for quality control
analysis. 相似文献
18.
An HPTLC method has been developed that coelutes both the isomers of cefpodoxime proxetil (CFP). CFP was chromatographed on a silica gel 60 F 254 TLC plate using toluene:acetonitrile (6:4) as a mobile phase and was quantified at 234 nm. The method was validated with respect to linearity, accuracy, precision and specificity. The limit of detection and limit of quantification for CFP were found to be 0.150 and 0.4 μg spot ?1, respectively. The proposed method was successfully used to determine the amount of CFP present in the marketed tablets and self-nanoemulsifying systems. 相似文献
19.
以 C18柱为分离柱 ,三乙胺·磷酸溶液-乙腈 (体积比 82∶ 18)为流动相 ,检测波长为 286 nm的液相色谱法测定氟罗沙星胶囊中的氟罗沙星含量 ,在 0.005~ 2.5 μ g 范围内进样量与主峰面积线性关系良好 (r=0.999 9),最小检测量 0.005 μ g,检出限 0.000 2 μ g,平均回收率为 100.2% ,重复进样相对标准偏差 0.50%。 相似文献
20.
JPC – Journal of Planar Chromatography – Modern TLC - A simple, rapid, and reliable HPTLC method has been developed for determination of ethamsylate in tablets. Identification and... 相似文献
|