首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
A relatively noninvasive method consisting of a face mask sampling device, solid-phase microextraction (SPME) fibers, and a gas chromatography-mass spectrometry (GC-MS) for the identification of volatile organic compounds (VOCs) in bovine breath was developed. Breath of three morbid steers with respiratory tract infections and three healthy steers were sampled seven times in 19 days for 15 min at each sampling. The breath VOCs adsorbed on the divinylbenzene (DVB)-Carboxen-polydimethyl siloxane (PDMS) 50/30 microm SPME fibers were transported to a laboratory GC-MS system for separation and identification with an in-house spectral library of standard chemicals. A total of 21 VOCs were detected, many of them for the first time in cattle breath. Statistical analyses using Chi-square test on the frequency of detection of each VOC in each group was performed. The presence of acetaldehyde (P < or = 0.05) and decanal (P < or = 0.10) were associated more with clinically morbid steers while methyl acetate, heptane, octanal, 2,3-butadione, hexanoic acid, and phenol were associated with healthy steers at P < or = 0.10. The results suggest that noninvasive heath screening using breath analyses could become a useful diagnostic tool for animals and humans.  相似文献   

2.
Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Applications range from atmospheric research and ambient air monitoring (indoor and outdoor) to occupational hygiene (personal exposure assessment) and measuring chemical emission levels. Part 1 of this paper reviewed the main sorbent-based air sampling strategies including active (pumped) tube monitoring, diffusive (passive) sampling onto sorbent tubes/cartridges plus sorbent trapping/focusing of whole air samples that are either collected in containers (such as canisters or bags) or monitored online. Options for subsequent extraction and transfer to GC(MS) analysis were also summarised and the trend to thermal desorption (TD)-based methods and away from solvent extraction was explained. As a result of this trend, demand for TD-compatible sorbents (alternatives to traditional charcoal) is growing. Part 2 of this paper therefore continues with a summary of TD-compatible sorbents, their respective advantages and limitations and considerations for sorbent selection. Other analytical considerations for optimizing sorbent-based air monitoring methods are also discussed together with recent technical developments and sampling accessories which have extended the application range of sorbent trapping technology generally.  相似文献   

3.
Effects of ozone on air sampling of standard gas mixtures of aromatic hydrocarbons were tested using solid-phase microextraction (SPME). Standard concentrations of ozone ranging from 10 ppb (v/v) to 6400 ppm (v/v) were generated using an in-house built ozone generator based on corona discharge. Effects of temperature, discharge voltage, and oxygen flow on the ozone generation were tested. The working dc voltage had the greatest effect on generated ozone concentration and was proportional to the ozone concentration. Generation temperature and oxygen flow rate were inversely proportional to ozone concentrations. Produced ozone was mixed with standard benzene, toluene, ethylbenzene, and xylenes (BTEX) gas at less than 100 ppb (v/v). Air samples were collected with poly(dimethylsiloxane) (PDMS) 100 microm SPME fibers and analyzed by gas chromatography (GC)-flame ionization detection (FID) and GC-MS. Significant reductions of BTEX concentrations were observed. In addition, some products of BTEX-ozone-oxygen reactions were identified. SPME worked well as a rapid sampler for BTEX and BTEX-ozone-oxygen reaction products. No significant deterioration of the PDMS coating and no significant reduction of absorption capacity were observed after repeated exposure to ozone.  相似文献   

4.
Practical aspects of the application of solid-phase microextraction (SPME) to the determination of volatile aliphatic amines in air are described. Analytes included methylamine (MA), ethylamine (EA), dimethylamine (DMA), diethylamine (DEA), trimethylamine (TMA) and triethylamine (TEA). New SPME stationary phases were examined. The effects of relative humidity and temperature on analytes uptake were taken into account in analysis. Gas chromatography (GC) with flame ionization detector (FID) was used for the final analysis.  相似文献   

5.
Summary Solid-phase microextraction is a relatively recent extraction technique for sample preparation. It has been used successfully to analyse environmental pollutants in a variety of matrices such as soils, water and air. In this work, a simple and rapid method for the analysis of volatile organic and polar compounds from polluted groundwater samples by SPME coupled with gas chromatography (GC) is described. Different types of fibres were studied and the extraction process was optimised. The fibre that proved to be the best to analyse this kind of samples was CAR-PDMS. The method was validated by analysis of synthetic samples and comparison with headspace—GC. The optimised method was successfully applied to the analysis of ground-water samples.  相似文献   

6.
Solid-phase microextraction was used as a technique for headspace sampling of extra virgin olive oil and virgin olive oil samples with different off-flavours. A 100 microm coated polydimethylsiloxane fiber was used to extract volatile aldehydes, the sampling temperature was 45 degrees C and the fiber has been exposed to the headspace for 15 min. Nonanal and 2-decenal were present in all the olive oils with extraction off-flavours but were not in extra virgin olive oil sample.  相似文献   

7.
Sorbent tubes/traps are widely used in combination with gas chromatographic (GC) analytical methods to monitor the vapour-phase fraction of organic compounds in air. Target compounds range in volatility from acetylene and freons to phthalates and PCBs and include apolar, polar and reactive species. Airborne vapour concentrations will vary depending on the nature of the location, nearby pollution sources, weather conditions, etc. Levels can range from low percent concentrations in stack and vent emissions to low part per trillion (ppt) levels in ultra-clean outdoor locations. Hundreds, even thousands of different compounds may be present in any given atmosphere. GC is commonly used in combination with mass spectrometry (MS) detection especially for environmental monitoring or for screening uncharacterised workplace atmospheres. Given the complexity and variability of organic vapours in air, no one sampling approach suits every monitoring scenario. A variety of different sampling strategies and sorbent media have been developed to address specific applications. Key sorbent-based examples include: active (pumped) sampling onto tubes packed with one or more sorbents held at ambient temperature; diffusive (passive) sampling onto sorbent tubes/cartridges; on-line sampling of air/gas streams into cooled sorbent traps; and transfer of air samples from containers (canisters, Tedlar® bags, etc.) into cooled sorbent focusing traps. Whichever sampling approach is selected, subsequent analysis almost always involves either solvent extraction or thermal desorption (TD) prior to GC(/MS) analysis. The overall performance of the air monitoring method will depend heavily on appropriate selection of key sampling and analytical parameters. This comprehensive review of air monitoring using sorbent tubes/traps is divided into 2 parts. (1) Sorbent-based air sampling option. (2) Sorbent selection and other aspects of optimizing sorbent-based air monitoring methods. The paper presents current state-of-the-art and recent developments in relevant areas such as sorbent research, sampler design, enhanced approaches to analytical quality assurance and on-tube derivatisation.  相似文献   

8.
A new adsorbent, high-surface-area graphitized carbon black (HSGCB), with a surface area of 560 m2/g, superior to that of commonly traded graphitized carbons, was studied. The evaluation was performed in terms of breakthrough volumes and thermal desorption recoveries of substances representative of the main classes of organic compounds. HSGCB was found to be an interesting alternative to activated charcoal for volatile compounds in that it can be used in thermal desorption.  相似文献   

9.
The ultimate goal of the chemist is to perform sample preparation, and analysis, if possible at the place where a sample is located rather than moving the sample to laboratory, as is common practice in many cases at the present time. This approach eliminates errors and time associated with sample transport and storage and therefore it would result in more accurate, precise and faster analytical data. In addition to portability, two other important features of ideal field sample preparation technique are elimination of solvent use and integration with a sampling step. A method is developed which addresses these requirements for the determination of time-weighted average concentration of gas phase compounds using a solid-phase microextraction device. Quantification of target analytes in air using this method can be carried out without external calibration. The volatile and semi-volatile organic compounds in air diffuse into the fiber coating which is retracted a known distance into its needle housing during the sampling period. The coatings used are poly(dimethylsiloxane) and poly(dimethylsiloxane)-divinylbenzene. The sampling rate at which gas phase analytes load onto the fiber is determined for a wide range of hydrocarbons. There is a good agreement between the theoretical and experimental sampling rates. Sampling time ranges from 1 min to 24 h depending on the coating used and its retraction distance. Effect of the flow-rate on the uptake rate by the fiber is studied. The method is tested in the field and compared with National Institute of Occupational Health and Safety Method 1550. Good agreement between the results is obtained.  相似文献   

10.
Traditional simultaneous distillation extraction (SDE) and solid-phase microextraction (SPME) techniques were compared for their effectiveness in the extraction of volatile flavor compounds from various mustard paste samples. Each method was used to evaluate the responses of some analytes from real samples and calibration standards in order to provide sensitivity comparisons between the two techniques. Experimental results showed traditional SDE lacked the sensitivity needed to evaluate certain flavor volatiles, such as 1,2-propanediol. Dramatic improvements in the extraction ability of the SPME fibers over the traditional SDE method were noted. Different SPME fibers were investigated to determine the selectivity of the various fibers to the different flavor compounds present in the mustard paste samples. Parameters that might affect the SPME, such as the duration of absorption and desorption, temperature of extraction, and the polarity and structure of the fiber were investigated. Of the various fibers investigated, the PDMS–DVB fiber proved to be the most desirable for these analytes.  相似文献   

11.
Multiple headspace solid-phase microextraction (MHS-SPME) coupled with gas chromatography-mass spectrometry has been applied in order to determine 2,4,6-trichloroanisole (2,4,6-TCA), guaiacol, 1-octen-3-ol and 1-octen-3-one in three samples of cork stoppers. These compounds are responsible for cork taint in wine and can modify the organoleptic properties of bottled wine. Variables such as temperature, addition of water, extraction time, and amount of cork were studied. The extractions were performed with a 50/30 microm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fibre for 45 min at 100 degrees C using 20 mg of cork. For calibration, 50 microL of VOC aqueous solutions were used and the extraction were carried out for 45 min at 75 degrees C. The limits of detection of the method expressed as ng of VOC per g of cork were 0.3 for 2,4,6-TCA, 7.5 for guaiacol, 1.7 for 1-octen-3-one and 1.9 for 1-octen-3-ol. Relative standard deviation of replicate samples was less than 10%. Significant losses of analytes were observed when the samples were ground at room temperature. Finally, a recovery study was performed and the MHS-SPME results were validated using Soxhlet extraction results.  相似文献   

12.
A rapid and solvent-free method for the determination of eight volatile organic sulphur and two selenium compounds in different beverage samples using headspace solid-phase microextraction and gas chromatography with atomic emission detection has been developed. The bonded carboxen/polydimethylsiloxane fiber was the most suitable for preconcentrating the analytes from the headspace of the sample solution. Volumes of 20 mL of undiluted beer were used while, in the case of wines and spirits, sample:water ratios of 5:15 and 2:18, respectively, were used, in order to obtain the maximum sensitivity. Quantitation was carried out by using synthetic matrices of beer and wine, and a spiked sample for spirits, and using ethyl methyl sulphide and isopropyl disulphide as internal standards. Detection limits ranged from 8 ng L−1 to 40 ng mL−1, depending on the compound and the beverage sample analyzed, with a fiber time exposure of 20 min at ambient temperature. The optimized method was successfully applied to different samples, some of the studied compounds being detected at concentration levels in the 0.04–152 ng mL−1 range.  相似文献   

13.
An automatic calibration apparatus for the dynamic generation of organic vapours was developed. The accurately controlled stream of nitrogen was drawn at a low flow-rate through a thermostated container filled with the standard substance, thus generating a continuous stream of saturated vapour of the compound. The compound holder vessel was thermostated at −16°C. A large stream of pure carrier gas was mixed with a low stream of substance in a mixing chamber for dilution. The fittings were manufactured from PTFE, and tubes were made of special PTFE with an inert inner surface to eliminate the wall adsorption and to decrease the cross-diffusion. Moisture interferences were reduced using a Nafion membrane filter. The vapour generator was validated by diffusive sampling and gas chromatographic methods. Standard mixtures have been prepared containing toluene at concentrations ranging from 3 to 3000 ppm. The combined uncertainty of preparative and analytical error components associated with the concentration of the analytes at the 95% confidence level typically ranges from 2 to 5% relative, depending upon the concentration. The measured and the calculated values were compared and good correlation (r2>0.99) was found.  相似文献   

14.
Microwave processing offers an alternative to blanch fruits and vegetables, since the application of high temperature and short time often results in minimum damage. An experimental design was used to investigate the effect of microwave time, pH, and avocado leaves (independent variables) on avocado flavor (response) using solid-phase microextraction (SPME)-GC-MS. Among the fully characterized flavor volatiles, 19 compounds were derived from lipid oxidation and only 4 from the avocado leaves. The main components derived from lipids were aldehydes, ketones and alcohols. Terpenoids, estragole, and 2-hexenal [E] were volatiles derived from avocado leaves. When leaves were added to fresh and microwaved avocado terpenoids and 2-hexenal [E]/hexanal ratio increased, this behavior was considered to have a positive effect on the sensorial quality of the product. From the statistical analysis of the experimental design, it was possible to determinate that the most important factors influencing the abundance of flavor compounds derived from lipids were microwave time and pH. Maximum values of these compounds were detected at high levels of microwave time and low values of pH. On the other hand, response surface of terpenoids and estragole showed an increment when microwave time and avocado leaf was increased. The region of optimum response was 30 s microwave time, pH 5.5, and 1% of avocado leaf.  相似文献   

15.
P. Popp  A. Paschke 《Chromatographia》1997,46(7-8):419-424
Summary A new 80 μm Carboxen-polydimethylsiloxane (PDMS) fiber for solid phase microextraction (SPME) was tested for the enrichment of volatile organic compounds from water and air. Detection limits between 13 ng L−1 (CH2Cl2) and 0.1 ng L−1 (CHCl2Br and CHClBr2) for the combination: Carboxen-PDMS fiber and GC-ECD and between 35 ng L−1 and 45 ng L−1 (BTEX compounds) for the combination: Carboxen-PDMS and GC-FID using the headspace procedure were determined. Comparisons with the 100 μm PDMS fiber and further coatings show the advantages of the Carboxen-PDMS fiber with respect to extraction efficiency. Disadvantages of the new fiber compared with the 100 μm PDMS fiber are poorer repeatability and prolongation of equilibrium time. Distribution coefficients of the BTEX compounds between aqueous solution and SPME fiber coating were calculated and compared with the results of other researchers and with octanol-water partition coefficients.  相似文献   

16.
An injection method for a large amount of headspace gas which enables determination of trace amounts of very volatile organic compounds (VVOCs), dichlorodifluoromethane, chloromethane, vinyl chloride, bromomethane, chloroethane and trichlorofluoromethane in all kinds of environmental water was developed. A gas phase equilibrated with the water phase in a vial was purged with helium for a short time. The VVOCs were then introduced into a trapping tube packed with Tenax TA, which had been cooled using carbon dioxide. After trapping, the VVOCs were thermally desorbed and put into a GC–MS system for subsequent analysis. This method is applicable to various types of samples.  相似文献   

17.
Headspace solid phase microextraction (headspace SPME) has been demonstrated to be an excellent solvent-free sampling method. One of the major factors contributing to the success of headspace SPME is the concentrating effect of the fiber coating toward organic compounds. The affinity of the fiber coating toward very volatile analytes, such as chloromethane, may, however, not be large enough for detection at the parts per trillion concentration level. Static headspace analysis, on the other hand, is very effective for these very volatile compounds. As analyte volatility decreases, the sensitivity of static headspace analysis drops. The complementary nature of these two sampling methods can be exploited by combining the SPME device with a gastight syringe. The sensitivity of the new sampling device is better than that of SPME for very volatile compounds or that of static headspace analysis for less volatile compounds. This new method can sample a wide range of compounds from chloromethane (b.p. −24°C) to bromoform (b.p. 149°C) with estimated limits of detection at the low parts per trillion level.  相似文献   

18.
Volatile organic compounds (VOCs) are toxic compounds in the air, water and land. In the proposed method, ultrasound-assisted emulsification microextraction (USAEME) combined with gas chromatography-mass spectrometry (GC-MS) has been developed for the extraction and determination of eight VOCs in water samples. The influence of each experimental parameter of this method (the type of extraction solvent, volume of extraction solvent, salt addition, sonication time and extraction temperature) was optimized. The procedure for USAEME was as follows: 15 μL of 1-bromooctane was used as the extraction solvent; 10 mL sample solution in a centrifuge tube with a cover was then placed in an ultrasonic water bath for 3 min. After centrifugation, 2 μL of the settled 1-bromooctane extract was injected into the GC-MS for further analysis. The optimized results indicated that the linear range is 0.1-100.0 μg/L and the limits of detection (LODs) are 0.033-0.092 μg/L for the eight analytes. The relative standard deviations (RSD), enrichment factors (EFs) and relative recoveries (RR) of the method when used on lake water samples were 2.8-9.5, 96-284 and 83-110%. The performance of the proposed method was gauged by analyzing samples of tap water, lake water and river water samples.  相似文献   

19.
建立了顶空固相微萃取(HSSPME)-气相色谱(GC)-质谱(MS)联用测定纺织品中甲苯、4-乙烯基环己烯、苯乙烯、萘和1-苯基环己烯5种挥发性有机物(VOCs)的分析方法。选择聚二甲基硅氧烷(PDMS)作为萃取涂层,优化了SPME的萃取条件,包括平衡时间、萃取时间、萃取温度、顶空体积、离子强度、搅拌速度、解吸温度和时间以及GC—MS仪器条件。对于甲苯、4-乙烯基环己烯、苯乙烯、萘和1-苯基环己烯方法线性范围分别为0.087~870、3.32~3320、2.28~2280、0.015~150和0.050~50.0ng/g;检出限分别为0.005、0.042、0.670、0.008和0.011ng/g。实际样品加标回收率在80.1%~122%之间,RSD在0.8%~8.6%之间。方法符合纺织品中痕量VOCs的快速分析要求。  相似文献   

20.
In this study, the cooling effect was applied to an evanescent wave type infrared (IR) chemical sensing method to effectively trap volatile organic compounds (VOCs), which have been absorbed in the hydrophobic film coated around the internal reflection element (IRE). The detection of VOCs in aqueous solutions was taken in the headspace of the aqueous solution. This method eliminates the long-term instability of hydrophobic film soaked in an aqueous solution and the potential spectral interference caused by the matrix of the aqueous solution. Thermal energy has been applied to the aqueous solution to assist in the evaporation of VOCs out of the aqueous matrix. By applying a cooling system to the IRE, the excess thermal energy can be removed leading to more stable IR signals. After examination of organic compounds with vapour pressure (Pv) ranging from 0.017 to 150 Torr, significant differences were found between IR signals from cooled and un-cooled systems. Because the thermal conductivity of the IRE used in IR detection is typically low; the efficiency in removing the thermal energy is limited. By heating the aqueous solutions to different temperatures, the IR signals showed that the sample temperature was limited to around 80 °C. The IR signal determination results for five different volatility organic compounds indicated that the optimal heating temperature was not necessary to match with the volatilities of organic compounds in cooling system. The linear regression coefficient (R2) of the standard curve for sample concentrations in the range 5-200 μg ml−1 was generally higher than 0.991 and the detection limit was around a few hundred ng ml−1, which was two to three times lower than that of un-cooled system.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏