Matthias Harder Anna Fiegl-Lechner Herbert Oberacher Ulrike E. I. Horvath Andreas Schlager Martina Jeske Sylvia Kerndler Falko Schüllner Günther K. Bonn Matthias Rainer 《Biomedical chromatography : BMC》2022,36(4):e5340
In this study, different injection solutions containing opioid and nonopioid compounds used for patient-controlled analgesia in hospice and palliative care were evaluated in terms of analyte stability. Investigated injection solutions contained different combinations of morphine, hydromorphone, metamizole and esketamine. For the practical implementation, samples from infusion pumps were daily drawn over a period of 7 days at 22 and 37°C. Quantitative measurements were performed on a high-performance liquid chromatography system with ultraviolet detection applying a validated analytical method. All compounds apart from morphine showed no evident changes in concentration. However, a significant loss of morphine was observed for injection mixtures containing both morphine and metamizole at 37°C. After 7 days, only 72% of the initially measured morphine concentration was measured in the binary and 77% in the ternary mixture. Furthermore, an additional compound was detected that could represent the morphine-metamizole-adduct, “metamorphine”. Based on these results, a significantly reduced morphine concentration must be expected after only 3 days if an injection solution mixture containing both morphine and metamizole is administered to a patient at 37°C. Since the analgesic effects of morphine–metamizole adducts have not yet been thoroughly investigated, further clinical studies are necessary before accurate conclusions can be drawn in this regard. 相似文献