1.
菠菜叶绿素的浸提和协同萃取反应   总被引:27,自引:0,他引:27  
有机溶剂;菠菜叶绿素的浸提和协同萃取反应  相似文献   

2.
QuEChERS original method was modified into a new version for pesticides determination in soils. The QuEChERS method is based on liquid–liquid portioning with ACN and was followed by cleanup step using dispersive SPE and disposable pipette tips. Gas chromatographic separation with MS detection was carried out for pesticides quantification. The method was validated using recovery experiments for 36 multiclass pesticides. Mean reco‐veries of pesticides at each of the four spiking levels between 10–300 μg/kg of soil ranged from 70–120% for 26 pesticides with RSD values less than 15%. The method achieved low limit of detection less than 7.6 μg/kg. Matrix effects were observed for 13 pesticides. Matrix effects were compensated by using matrix‐matched calibration. The method was applied successfully using d‐SPE or DPX in the analysis of the pesticides in soils from organic farming and integrated pest management.  相似文献   

3.
Direct injection and solid‐phase extraction methods for the determination of diquat and paraquat in surface and drinking water were developed using liquid chromatography with tandem mass spectrometry. The signal intensities of analytes based on six ion‐pairing reagents were compared with each other, and 12.5 mM nonafluoropentanoic acid was selected as the best suited amongst them. A clean‐up method was developed using Oasis hydrophilic–lipophilic balance; this was compared to the direct injection method, with respect to limits of detection, interference, precision, and accuracy. Limits of quantification of diquat and paraquat were 0.03 and 0.01 μg/L using the direct injection method, and 0.002 and 0.001 μg/L using the hydrophilic–lipophilic balance method. When the hydrophilic–lipophilic balance method was used to analyze target compounds in 114 surface water and 30 drinking water samples, paraquat and diquat were detected within a concentration range of 0.001–0.12 and 0.002–0.038 μg/L in surface water, respectively. When the direct injection method was used to analyze target compounds in the same samples, the detected concentrations of paraquat and diquat were within 25% in samples being >0.015 μg/L using the hydrophilic–lipophilic balance method. The liquid chromatography with tandem mass spectrometry method using direct injection can thus be used for routine monitoring of paraquat and diquat in surface and drinking water.  相似文献   

4.
A method to analyze the performance of an antibody capture method using fluorescent peptides by capillary zone electrophoresis using laser-induced fluorescence (CZE-LIF) for detection has been developed. Fluorescent peptides from the prion protein were synthesized and the corresponding antibodies were produced in rabbits against these peptides. The antibodies were used to capture the fluorescent peptides. The antibodies were then bound to protein A Sepharose. After elution, the amount of fluorescent peptide that was captured vs. the total amount placed in the assay was evaluated by CZE-LIF. Of the three peptides used in this evaluation, it was found that the recovery was approximately 25-35%. When the abnormal prion protein was prepared from scrapie-infected brain samples from hamsters and a sheep using the previously described extraction method and this method, the amount of abnormal prion protein that was measured in the fluorescence immunoassay correlated with amounts estimated from Western blot. We conclude that this method can be used to detect abnormal prion protein in a tissue sample.  相似文献   

5.
Summary Atrazine was extracted from two weathered soil samples with the proposed micro extraction method using ethyl acetate as the extracting agent. The results were compared with other extraction methods tested. The proposed micro method was equally effective as the micro on-line method using acetone for the extraction and more effective than the Soxhlet extraction using acetone and methanol. Therefore, the proposed micro ethyl acetate method can be used for routine analysis.  相似文献   

6.
A high-performance liquid chromatographic (HPLC) method is described for the determination of duloxetine hydrochloride in capsules. The method was based on pre-column derivatization with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole using the fluorimetric detection technique. Duloxetine hydrochloride was analyzed by HPLC using an Inertsil C18 column (5 μm, 150 × 4.6 mm) and mobile phase consisted of methanol and water (65:35, v/v). The fluorescence detector was adjusted at excitation and emission wavelengths of 461 and 521 nm, respectively. The linearity of the method was in the range of 10-600 ng/mL. Limits of detection and quantification were 0.51 and 1.53 ng/mL, respectively. The proposed method was successfully applied for determination of duloxetine hydrochloride in its pharmaceutical preparation. The results were in good agreement with those obtained using a reference method.  相似文献   

7.
Analysis of testosterone was accomplished using corona discharge ion mobility spectrometry. Molecular imprinted polymer was used for the extraction and pre-concentration of testosterone. Analytical parameters including precision, dynamic range and detection limit were obtained. The linear dynamic range was from 10 to 250 ng/mL and the limit of detection was 0.9 ng/mL. The proposed method was used for analysis of testosterone in urine samples. A urine sample from a 3-year-old girl was used as the blank. The RSD was below 10%. The obtained results from the method were also compared with the standard method for analysis of testosterone using SPE-HPLC analysis. The results demonstrate the accuracy of the method.  相似文献   

8.
An improved analytical method for airborne lead traces is reported. It is based on using a Venturi scrubber sampling device for simultaneous thin-film stripping and droplet entrapment of aerosol influxes. At least threefold enhancement of the lead-trace pre-concentration is achieved. The sampled traces are analyzed by square-wave anodic stripping voltammetry. The method was tested by a series of pilot experiments. These were performed using contaminant-controlled air intakes. Reproducible calibration plots were obtained. The data were validated by traditional analysis using filter sampling. LODs are comparable with the conventional techniques. The method was successfully applied to on-line and in situ environmental monitoring of lead.  相似文献   

9.
10.
偶氮苯衍生物Langmuir-Blodgett膜的结构与红外热释电性能   总被引:1,自引:0,他引:1  
利用Langmuir-Blodgett(LB)方法,在镀有金属膜的盖玻片和CaF_2衬底上转移了双嗜性偶氮苯衍生物多层LB膜.用线性红外二向色性光谱方法研究了分子的各跃迁矩的取向和分子长轴的取向.利用X射线衍射方法研究了LB膜的有序周期结构,讨论了双周期结构与高热释电活性的关系.  相似文献   

11.
ICP-AES测定钼铁中杂质元素   总被引:6,自引:0,他引:6  
陆军  刘琰 《理化检验(化学分册)》2005,41(12):905-906,909
研究了用ICP-AES测定钼铁中硅、磷和铜的方法,建立了最佳工作条件,采用基体匹配方法,应用软件中谱线干扰校正程序消除了干扰,检出限小于0.005%,回收率在93%-108%之间,RSD小于1.0%。方法简便、快速、准确。  相似文献   

12.
A method for the fast sequential extraction of toxic elements in contaminated soil samples using an ultrasonic water bath, followed by determination with inductively coupled plasma optical emission spectrometry (ICP-OES), was developed and compared with other methods introduced in the literature. The five-step sequential extraction (Tessier scheme) was shortened using ultrasound-assisted sequential extraction (UASE). The optimization of the five-step sequential extraction was based on the analysis of SRM 2710 using Tessiers’s method as a reference. Several extracting solutions with different sonication times and temperatures were tested in the optimization procedure. Concentrations of arsenic, cadmium, copper, lead, and zinc were determined in SRM 2710, SRM 2711, and contaminated soil samples with high accuracy and precision. The certified acid-leachable concentrations of the SRM 2710 were obtained for all elements investigated by using an optimized UASE method. Tessiers’s method yielded total element concentrations that were too high. The determination of zinc in SRM 2711 yielded concentrations that were too low, whereas arsenic determination yielded concentrations that were too high by the UASE method and analysis by ICP-OES. The analysis of the SRMs showed that the UASE method is highly comparable with the other methods used for such purposes. The major advantages of the UASE method are the high treatment rate (40 samples simultaneously with a sonication time of 54 min) and a low sample and reagent usage.  相似文献   

13.
The detection of a sample current under atmospheric conditions was applied to XAFS measurements of a Ni foil and NiO powders, and the feasibility of the conversion electron yield (CEY) detection was examined. The obtained XAFS spectra were compared with those obtained using the conventional transmission method; it is concluded that fairly good statistics can be obtained using the CEY method and that the obtained spectra show an identical structure to those obtained using the transmission method.  相似文献   

14.
An analytical method was developed to detect mandipropamid residues in sesame leaves using high‐performance liquid chromatography–ultraviolet detection. Samples were extracted with acetonitrile and were prepurified using a solid‐phase extraction (SPE) cartridge with an additional dispersive‐SPE (d‐SPE) sorbent application. The method was validated using an external calibration curve prepared using pure solvent. The linearity was excellent with determination coefficient = 1. The limits of detection and quantification were 0.003 and 0.01 mg/kg, respectively. Recoveries at three spiking levels – 0.1, 0.5, and 1.0 mg/kg – were in the range 80.3–90.7% with relative standard deviations <2%. This method was applied to field‐treated samples collected from two different areas, Gwangju and Muan, in the Republic of Korea and the half‐lives were similar, 5.10 and 5.41 days, respectively. The pre‐harvest residue limit was also predicted for both sites. The proposed method is sensitive and able to quantify trace amounts of mandipropamid in leafy vegetables. The combination of SPE and d‐SPE effectively removed the matrix components in sesame leaves. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

15.
采取沸水浴法、回流法、微波法及超声波法探讨信阳红茶和印度红茶的抗氧化性,通过测定吸光度利用Fenton反应表征提取物对羟自由基的清除率.不同的提取方法对红茶抗氧化活性有一定的影响,羟自由基的清除率与红茶的抗氧化活性成正比.结果表明:信阳红茶沸水浴法提取率较高,印度红茶超声波法提取率较高.  相似文献   

16.
采用反相悬浮聚合法制备了甲基丙烯酸羟乙酯(HEMA)与N-乙烯基吡咯烷酮(NVP)的交联共聚微球HEMA/NVP,然后采用"接出"法,实施了甲基丙烯酸(MAA)在交联微球表面的接枝聚合,制得了接枝微球PMAA-HEMA/NVP.以溶菌酶(LYZ)为模型碱性蛋白,深入研究了接枝微球PMAA-HEMA/NVP对碱性蛋白的吸附性能与吸附机理.测定了微球PMAA-HEMA/NVP的zeta电位,考察了PMAA接枝度、介质pH值及离子强度等因素对体系吸附性能的影响.结果表明,在较大的pH范围内,接枝微球PMAA-HEMA/NVP的zeta电位为绝对值较大的负值,即其表面携带有高密度的负电荷.在强静电相互作用的驱动下,接枝微球PMAA-HEMA/NVP对溶菌酶表现出很强的吸附能力.随介质pH值的增高,接枝微球对溶菌酶的吸附容量呈现先增大后减小的变化趋势,在与溶菌酶等电点接近的pH值处(pH=9),具有最大的吸附容量(90mg.g-1);离子强度对接枝微球的吸附能力也有较大的影响,当pH9时,溶菌酶吸附容量随NaCl浓度的增高而减小;当pH9时,吸附容量随NaCl浓度的增高而增大.  相似文献   

17.
A sensitive and selective method has been developed for the simultaneous detection in blood of eleven trichothecenes of widely varying polarity. The procedure involved precipitation of blood proteins with acetone followed by a clean-up using reversed-phase Sep-Pak C18 cartridges. The extracted trichothecenes were derivatised as their pentafluoropropionyl esters, separated using capillary gas chromatography and detected using electron-capture negative ion chemical ionisation with methane reagent gas and selected-ion monitoring. Optimum sensitivity and selectivity were obtained using low source temperatures (60 degrees C indicated) and high source pressures (1 Torr indicated). Detection limits on 1-ml blood samples were in the range 0.1-5 ppb. The method was readily adaptable to the detection of other trichothecenes. A protocol was used which minimised the risk of cross-contamination. The method was validated in collaborative studies by the successful analysis of 42 blood samples spiked and submitted blind by two independent laboratories for analysis.  相似文献   

18.
A simple and rapid detection method of oligosaccharides using high-performance liquid chromatography with a charged aerosol detection (HPLC-CAD) was studied. The direct detection of a sialylglycopeptide (SGP) derived from egg yolk was accomplished by HPLC-CAD using an amido-silica column, and its limit of detection was 0.40 pmol [signal-to-noise ratio (S/N) = 3]. The sensitivity of this method was lower than that of the fluorescence detection; however, the method showed approximately 5 times higher sensitivity than that using the conventional UV absorbance detection. Furthermore, this method was used for the analysis of the acid hydrolysis products of SGP. Monosialo- and asialo-oligosaccharides as well as free sialic acid were detected without using fluorescent derivatization. These results indicate that the present method is a new tool for the analysis of oligosaccharides.  相似文献   

19.
A simple confirmatory method for the determination of spiramycin and its metabolite neospiramycin in raw milk using LC ESI MS/MS is presented. Macrolide residues in raw milk were extracted by ACN, and sample extracts were further cleaned up and concentrated using SPE cartridges. Both spiramycin and neospiramycin were protonated in electrospray positive ion mode to form singly and/or doubly charged pseudomolecular ions. Data acquisition was achieved using multiple reaction monitoring, i.e., two transitions, for quantification and confirmation. Matrix‐matched standard calibration curves were utilized to achieve the best accuracy for the method. The method performance was evaluated according to both a conventional validation procedure and a designed experimental result. The measurement uncertainty arising from accuracy and precision was estimated. The method accuracy, expressed as a percentage of an overall recovery, was from 82.1 to 108.8%, and its intermediate precision was less than 20%. LC/ESI‐MS/MS method LODs (S/N ? 3:1) of spiramycin and neospiramycin were less than 1.0 μg/kg.  相似文献   

20.
Here are reported two new sampling method approaches for the determination of naphthalene in ambient air for concentrations from 0.25 to 18.7?µg/L. The first method used for gas phase naphthalene analysis produced an average recovery of 88.8% and the second method using headspace sampling produced an average recovery of 93.8%. The second method showed better recovery than the former, so it was used for subsequent comparative gas-phase determination of naphthalene. The second method was validated at various naphthalene concentrations and humidity using a naphthalene gas generator to produce various naphthalene standards and a naphthalene-monitoring instrument. The naphthalene concentrations generated using the gas generator and determined second sampling method with gas chromatography–mass spectrometry (GC–MS) were compared to the sensor measurements and were in good agreement. In summary, the sampling methods presented provided reliable gas-phase naphthalene determination when coupled with GC–MS.  相似文献   