首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A gas chromatographic-mass spectrometric procedure has been developed for the quantitation in plasma and urine of the enantiomers of rimantadine, an antiviral drug effective against type A influenza. The assay utilizes derivatization with an optically active reagent, selective ion monitoring, methane negative-ion chemical ionization (NICI) mass spectrometry and stable isotope dilution. The method has been used to measure concentrations of each rimantadine enantiomer over a range of 2.5-250 and 12.5-1250 ng/ml in the plasma and urine, respectively, of four male volunteers administered rimantadine. In plasma and urine, no differences were observed in the disposition of the unconjugated enantiomers. In urine, one enantiomer, but not both, was released following enzymatic hydrolysis.  相似文献   

2.
A three-phase liquid-phase microextraction (LPME) method using porous polypropylene hollow fibre membrane with a sealed end was developed for the extraction of mirtazapine (MRT) and its two major metabolites, 8-hydroxymirtazapine (8-OHM) and demethylmirtazapine (DMR), from human plasma. The analytes were extracted from 1.0 mL of plasma, previously diluted and alkalinized with 3.0 mL 0.5 mol L−1 pH 8 phosphate buffer solution and supplemented with 15% sodium chloride (NaCl), using n-hexyl ether as organic solvent and 0.01 moL L−1 acetic acid solution as the acceptor phase. Haloperidol was used as internal standard. The chromatographic analyses were carried out on a chiral column, using acetonitrile-methanol-ethanol (98:1:1, v/v/v) plus 0.2% diethylamine as mobile phase, at a flow rate of 1.0 mL min−1. Multi-reaction monitoring (MRM) detection was performed by mass spectrometry (MS-MS) using a triple-stage quadrupole and electrospray ionization interface operating in the positive ion mode. The mean recoveries were in 18.3-45.5% range with linear responses over the 1.25-125 ng mL−1 concentration range for all enantiomers evaluated. The quantification limit (LOQ) was 1.25 ng mL−1. Within-day and between-day assay precision and accuracy (2.5, 50 and 100 ng mL−1) showed relative standard deviation and the relative error lower than 11.9% for all enantiomers evaluated. Finally, the method was successfully used for the determination of mirtazapine and its metabolite enantiomers in plasma samples obtained after single drug administration of mirtazapine to a healthy volunteer.  相似文献   

3.
Capillary electrophoresis and liquid-phase microextraction using porous polypropylene hollow fibers were employed for the enantioselective analyses of mirtazapine and its metabolites demethylmirtazapine and 8-hydroxymirtazapine in human urine. Before the extraction, urine samples (1.0 mL) were submitted to enzymatic hydrolysis at 37 degrees C for 16 h. Then, the enzyme was precipitated with trichloroacetic acid, the pH was adjusted to 8 with 0.5 mol/L phosphate buffer solution (pH 11) and 15% sodium chloride was further added. The analytes were transferred from the aqueous donor phase, through n-hexyl ether (organic solvent immobilized in the fiber), into 0.01 moL/L acetic acid solution (acceptor phase). The electrophoretic analyses were carried out in 50 mmol/L phosphate buffer solution (pH 2.5) containing 0.55% w/v carboxymethyl-beta-cyclodextrin. The method was linear over the concentration range of 62.5-2500 ng/mL for each mirtazapine and 8-hydroxymirtazapine enantiomer and 62.5-1250 ng/mL for each demethylmirtazapine enantiomer. The quantification limit was 62.5 ng/mL for all the enantiomers. Within-day and between-day assay precision and accuracy were lower than 15% for all the enantiomers. Finally, the method proved to be suitable for pharmacokinetic studies.  相似文献   

4.
A method for the quantitative enantioselective analysis of amphetamine in human plasma by gas chromatography/negative ion chemical ionization mass spectrometry (GC/NICI-MS) is presented. Five-fold deuterated analogues of both enantiomers were used as internal standard. Plasma sample preparation was performed by a rapid liquid-liquid extraction using n-hexane. Derivatization with (S)-(-)-N-(heptafluorobutyryl)prolyl chloride was accomplished directly in the n-hexane extract to avoid loss of amphetamine during sample concentration. The method was validated in the expected concentration range of 0.006 for a pharmacokinetic study. Calibration curves were linear within a range 0.006-50 ng/mL plasma. Precision and accuracy were acceptable over the entire calibration range. Baseline separation of the enantiomers was easily achieved on a 15-m nonchiral apolar column. The method is simple and robust, and has been applied to the batch analysis of amphetamine enantiomers.  相似文献   

5.
An automated chiral chromatography/tandem mass spectrometry bioanalytical method for the determination of albuterol in dog plasma was developed. The method employed on-line sample extraction using turbulent flow chromatography coupled to a Chirobiotic T column for chiral separation using a polar organic mobile phase consisting of methanol, 0.02% formic acid, and 0.1% ammonium formate. The analytes were detected by a tandem mass spectrometer operated in positive ion mode. The (S)- and (R)-isomers were resolved chromatographically with retention times of 5.1 and 5.6 min, respectively. The analytical run time was 8 min. The enantiomers did not interconvert either in mobile phase or in dog plasma at room temperature over the course of at least 2 h. The assay has a linear dynamic range from 2.5-2500 nM for both enantiomers. The lower limit of quantitation (LLOQ) was 2.5 nM for both enantiomers using 50 microL of plasma. The accuracy and precision of intraday validation were determined at five concentration levels of six replicates. The accuracy of the method for the (R)-isomer ranged from 94-103% of nominal concentrations, and the precision (%CV) ranged from 3.6-12%. The accuracy of the method for the (S)-isomer ranged from 94.5-108% of nominal concentrations, and the precision ranged from 3.2-9.3%. Interday accuracy and precision were evaluated for three days at five concentrations for one replicate. The accuracy of the method for the (R)-isomer ranged from 98-110% of nominal concentrations, and the precision ranged from 1.5-10.6%. The accuracy of the method for the (S)-isomer ranged from 96-104% of nominal concentrations, and the precision ranged from 1.5-8.7%. The combination of turbulent flow on-line sample extraction with polar organic mode chiral chromatography provided a specific, rugged, and high-throughput method for the chiral analysis of albuterol in biological fluids.  相似文献   

6.
A peptide-doxorubicin conjugate (I) is a drug candidate that has been evaluated for the treatment of prostate cancer. During the high-performance liquid chromatographic (HPLC)-fluorescence analysis of clinical samples for compound I and its two known metabolites [doxorubicin (II) and leucine-doxorubicin (III)], additional metabolites are observed in postdose human plasma extracts. Using neutral loss, precursor, and product ion tandem mass spectrometric (MS-MS) experiments, two of these metabolites are identified as doxorubicinol (IV) and leucine-doxorubicinol (V), the active 13-hydroxy metabolites of doxorubicin and leucine-doxorubicin, respectively. A third metabolite, 7-deoxydoxorubicinol aglycone (VI), is detected using single-ion monitoring at m/z 399 in the negative ionization mode. The product ion mass spectrum of this metabolite contains a major fragment at m/z 351, resulting from the loss of water and formaldehyde from the pseudomolecular ion. An HPLC-MS-MS method for simultaneous analysis of II, III, IV, V, and VI is developed utilizing gradient HPLC with a combination of positive/negative ionization MS in the multiple reaction monitoring mode and monitoring the appropriate MS-MS transitions. Using this methodology, rat, dog, and human plasma metabolite profiles are compared and found to be qualitatively similar. Simultaneous fluorescence and MS detection experiments confirm that the peaks observed in the HPLC-fluorescence chromatograms of plasma extracts correspond to each of the five metabolites (II-VI).  相似文献   

7.
This paper describes a bioanalytical method involving a simple liquid-liquid extraction for the simultaneous HPLC determination of the enantiomers of tramadol, the active metabolite O-desmethyltramadol (M1), and the other main metabolite N-desmethyltramadol (M2) in biological samples. Chromatography was performed at 5 degrees C on a Chiracel OD-R column containing cellulose tris(3,5-dimethylphenylcarbamate) as chiral selector, preceded by a achiral end-capped C8 column (LiChrospher 60-RP-selected B 5 microm, 250 mm x 4 mm). The mobile phase was a mixture of phosphate buffer containing sodium perchlorate (1 M) adjusted to pH 2.5-acetonitrile-N,N-dimethyloctylamine (74.8:25:0.2). The flow rate was 0.5 ml/min. Fluorescence detection (lambda(ex) 200 nm/lambda(em) 301 nm) was used. Fluconazol was selected as internal standard. The limit of quantitation of each enantiomer of tramadol and their metabolites was 0.5 ng/ml (sample size = 0.5 ml). The chiral conditions and the LC optimisation were investigated in order to select the most appropriate operating conditions. The method developed has also been validated. Mean recoveries above of 95% for each enantiomer were obtained. Calibration curves for tramadol enantiomers (range 1-500 ng/ml), M1 enantiomers (range 0.5-100 ng/ml), and M2 enantiomers (range 0.5-250 ng/ml) were linear with coefficients of correlation better than 0.996. Within-day variation determined on four different concentrations showed acceptable values. The relative standard deviation (R.S.D.) was determined to be less than 10%. This method was successfully used to investigate plasma concentration of enantiomers of tramadol, O-desmethyltramadol and N-desmethyltramadol in a pharmacokinetic study.  相似文献   

8.
A parallel chiral/achiral LC-MS/MS assay has been developed and validated to measure the plasma and urine concentrations of the enantiomers of ketamine, (R)- and (S)-Ket, in complex regional pain syndrome (CRPS) patients receiving a 5-day continuous infusion of a sub-anesthetic dose of (R,S)-Ket. The method was also validated for the determination of the enantiomers of the Ket metabolites norketamine, (R)- and (S)-norKet and dehydronorketamine, (R)- and (S)-DHNK, as well as the diastereomeric metabolites hydroxynorketamine, (2S,6S)-/(2R,6R)-HNK and two hydroxyketamines, (2S,6S)-HKet and (2S,6R)-Hket. In this method, (R,S)-Ket, (R,S)-norKet and (R,S)-DHNK and the diastereomeric hydroxyl-metabolites were separated and quantified using a C18 stationary phase and the relative enantiomeric concentrations of (R,S)-Ket, (R,S)-norKet and (R,S)-DHNK were determined using an AGP-CSP. The analysis of the results of microsomal incubations of (R)- and (S)-Ket and a plasma and urine sample from a CRPS patient indicated the presence of 10 additional compounds and glucuronides. The data from the analysis of the patient sample also demonstrated that a series of HNK metabolites were the primary metabolites in plasma and (R)- and (S)-DHNK were the major metabolites found in urine. The results suggest that norKet is the initial, but not the primary metabolite and that downstream norKet metabolites play a role in (R,S)-Ket-related pain relief in CRPS patients.  相似文献   

9.
A stereospecific high-performance liquid chromatographic assay was developed for the quantitation of ketoconazole enantiomers (KTZ) in rat plasma. After protein precipitation of 100 microL plasma using acetonitrile, a wash step was performed using hexane. The supernatant was removed and KTZ enantiomers and amiodarone, the internal standard, were extracted using liquid-liquid extraction with tert-butyl methyl ether. After transfer and evaporation of the organic layer, the residue was reconstituted in mobile phase and injected into the HPLC through a chiral column. The mobile phase consisted of hexane:ethanol:2-propanol with diethyl amine, pumped at 1.5 mL/min. All components eluted within 18 min. KTZ enantiomers were baseline resolved and peaks were symmetrical in appearance with no interferences. Calibration curves were linear over the range 62.5-5000 ng/mL of enantiomer. The intraday and interday CV% assessments were 相似文献   

10.
Li Y  Dong F  Liu X  Xu J  Li J  Kong Z  Chen X  Song W  Wang Y  Zheng Y 《Journal of chromatography. A》2011,1218(38):6667-6674
A novel and sensitive method was developed for the simultaneous determination of fenbuconazole and its main metabolites enantioselectively using chiral liquid chromatography coupled with tandem mass spectrometry. The separation and determination were performed using reversed-phase chromatography on a cellulose chiral stationary phase, a Chiralcel OD-RH (150 mm×4.6 mm) column, under isocratic conditions at 0.5 mL/min flow rate. The effects of three cellulose-based columns and three amylose-based columns on the separation were also investigated. The elution orders of the eluting enantiomers were identified by an optical rotation detector. The QuEChERS (acronym for Quick, Easy, Cheap, Effective, Rugged and Safe) method and solid-phase extraction (SPE) were used for the extraction and clean-up of the soil and water samples, respectively. Parameters including the matrix effect, linearity, precision, accuracy and stability were evaluated. Under optimal conditions, the mean recoveries for all enantiomers from the soil samples were 82.5-104.1% with 2.7-9.5% intra-day relative standard deviations (RSD) and 5.7-11.2% inter-day RSD at 5, 25 and 50 μg/kg levels; the mean enantiomer recoveries from the water samples were 81.8-104.6% with 2.6-11.4% intra-day RSD and 5.3-10.4% inter-day RSD at 0.25, 0.5 and 2.5 μg/L levels. Coefficients of determination R2≥0.9991 were achieved for each enantiomer in the soil and water matrix calibration curves within the range of 1.0-125 μg/L. The limits of detection (LOD) for all enantiomers in the soil and water were less than 0.8 μg/kg, whereas the limit of quantification (LOQ) did not exceed 2.5 μg/kg. The results of the method validation confirm that this proposed method is convenient and reliable for the enantioselective determination of the enantiomers of fenbuconazole and its main metabolites in soil and water.  相似文献   

11.
Zopiclone is a hypnosedative with clinical effects similar to benzodiazepines but thought to have less potential for rebound insomnia and withdrawal effects. Zopiclone is administered as a racemic mixture, and an enantiospecific method of analysis of zopiclone in plasma is desirable in the study of pharmacokinetic drug interactions. We report a modification of an HPLC method reported by Foster et al. using a closely related structural analogue of zopiclone as internal standard. Zopiclone was detected at 306 nm and linear calibration curves were constructed in the range of 1.0-250 ng/mL for each enantiomer. The % CV at 2.5 ng/mL was 12.0% for (-)-zopiclone and 14.3% for (+)-zopiclone, and the limit of quantification of each enantiomer was 2.5 ng/mL. At higher concentrations, the coefficient of variation was less than 10%. The nominal concentration of quality control samples was predicted with an accuracy within a range of +/-11.6%. The method was used in the analysis of plasma obtained from psychiatric patients. One sample obtained following a non-fatal overdose with zopiclone contained the metabolites (-)-N-oxide zopiclone and both enantiomers of desmethyl zopiclone. The metabolite enantiomers were resolved on the column with retention times similar to zopiclone. The N-oxide metabolite co-eluted with internal standard.  相似文献   

12.
Liquid chromatographic analysis of propafenone enantiomers in human plasma   总被引:1,自引:0,他引:1  
A convenient and sensitive high-performance liquid chromatographic method for analysis of the enantiomers of propafenone (PPF) in human plasma was developed. Racemic propafenone and (-)-ephedrine (internal standard) were first extracted from plasma samples into a mixture of hexane-2-propanol-heptafluorobutanol (95:5:1.25, v/v). After evaporation of the organic layer, the samples were derivatized with R(-)-naphthylethyl isocyanate. The derivatization reached its maximum within 30 s at room temperature with an efficiency of 93.9 +/- 2.8% (mean +/- S.D.). The formed diastereomers were subsequently separated on a silica column with a mobile phase of hexane-2-propanol-isobutanol (96:2:2, v/v) at a flow-rate of 1.5 ml/min. The ultraviolet detection wavelength was set at 220 nm. Using 1 ml plasma, the detection limit was 6.25 ng/ml for the propafenone enantiomers. The assay was successfully employed to measure propafenone enantiomers in plasma samples of a healthy subject after oral administration of a single 150-mg dose of the racemate.  相似文献   

13.
A simple and robust method for quantification of zolpidem in human plasma has been established using liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI MS/MS). Es-citalopram was used as an internal standard. Zolpidem and internal standard in plasma sample were extracted using solid-phase extraction cartridges (Oasis HLB, 1 cm3/30 mg). The samples were injected into a C8 reversed-phase column and the mobile phase used was acetonitrile-ammonium acetate (pH 4.6; 10 mm) (80:20, v/v) at a flow rate of 0.7 mL/min. Using MS/MS in the selected reaction-monitoring (SRM) mode, zolpidem and Es-citalopram were detected without any interference from human plasma matrix. Zolpidem produced a protonated precursor ion ([M+H]+) at m/z 308.1 and a corresponding product ion at m/z 235.1. The internal standard produced a protonated precursor ion ([M+H]+) at m/z 325.1 and a corresponding product ion at m/z 262.1. Detection of zolpidem in human plasma by the LC-ESI MS/MS method was accurate and precise with a quantification limit of 2.5 ng/mL. The proposed method was validated in the linear range 2.5-300 ng/mL. Reproducibility, recovery and stability of the method were evaluated. The method has been successfully applied to bioequivalence studies of zolpidem.  相似文献   

14.
MK-0767, (+/-)-5-[(2,4-dioxothiazolidin-5-yl)methyl]-2-methoxy-N-[[(4-trifluoromethyl)phenyl]methyl]benzamide, is a thiazolidinedione-containing dual peroxisome proliferator-activated receptor (PPAR) alpha/gamma agonist that has been studied as a potential treatment for patients with type 2 diabetes. MK-0767 contains a chiral center at the C-5 position of the thiazolidinedione ring and was being developed as the racemate, due to the rapid interconversion of its enantiomers in biological samples. In the present work the in vitro and in vivo concentration ratios of the (+)-(R) to (-)-(S) enantiomers of MK-0767 were determined in plasma from humans (in vitro only) and nonclinical species used in the toxicological evaluation of rac-MK-0767, namely CD-1 mice, Sprague-Dawley rats, beagle dogs, New Zealand white rabbits, and rhesus monkeys. The R/S ratio was determined by chiral liquid chromatography/tandem mass spectrometry. Species differences were observed in the in vitro and in vivo enantiomeric ratios, as well as differences between in vitro and in vivo in some species. The in vitro R/S ratio was similar in dogs and humans (approximately 1.5-1.7). In rats and monkeys, the ratio was approximately unity, both in vitro and in vivo. In mice, the ratio was higher in vitro (approximately 1) than in vivo (approximately 0.6), while in rabbits it was higher in vivo (approximately 1) than in vitro (approximately 0.5). These results suggested that differential binding of the MK-0767 enantiomers to plasma and tissue proteins and other macromolecules may be affecting the R/S ratio both in vitro and in vivo, since in protein-free systems MK-0767 exists as the racemate.  相似文献   

15.
A sensitive and selective liquid chromatography–tandem mass spectrometric (LC–MS/MS) assay method has been developed and validated for the enantioselective determination of manidipine in human plasma using isotope‐labeled compounds as internal standards. After solid‐phase extraction, R ‐(−)‐manidipine and S ‐(+)‐manidipine were chromatographed on a Chiralpack IC‐3 C18 column using a isocratic mobile phase composed of 2 mm ammonium bicarbonate and acetonitrile (15:85, v /v). The precursor ion to product ion transitions for the enantiomers and internal standards were monitored in the multiple reaction monitoring and positive ionization mode using an API‐4000 mass spectrometer. The method was linear over the concentration range of 0.05–10.2 ng/mL for both enantiomers. The precision and accuracy results over five concentration levels in five different batches were well within the acceptance limits. The mean extraction recovery was >80% for both enantiomers. A variety of stability tests were executed in plasma and in neat samples, which complies with the FDA guidelines. After complete validation, the method was successfully applied to a pharmacokinetic study of a manidipine 20 mg oral dose in 10 healthy South India subjects under fasting conditions. The assay reproducibility is shown through incurred samples reanalysis of 20 subject plasma samples.  相似文献   

16.
Aminoacyl derivatives of aminoadamantanes amantadine and rimantadine have been investigated in regard to their antiviral properties. So far, few studies on the mass spectrometric fragmentation pathway of these compounds have been reported using high-resolution mass spectrometry (HRMS). Two major fragmentation pathways have been observed. For the rimantadine derivatives, losses of rimantadine and N-(1-adamantyl) ethylformamide were described. Similarly, in case of amantadine derivatives, there were losses of amantadine and N-(1-adamantyl) formamide. The loss of the aminoacyl group was common to all of the studied compounds. Understanding the fragmentation mechanism can bring new insight into the characterization of these compounds.  相似文献   

17.
A nonaqueous capillary electrophoresis/electrospray mass spectrometry method for the separation of lidocaine (LID) and two of its metabolites, monoethylglycinexylidide (MEGX) and glycinexylidide (GX), has been developed. The separation medium was: 70 mM ammonium formate and 2.0 M formic acid in acetonitrile/methanol (60:40 v/v). With a sheath liquid of methanol/water (80:20 v/v) containing 2% formic acid and positive ion detection, reproducible determinations (8-11% relative standard deviation (RSD)) of lidocaine and its metabolites were performed in spiked human plasma. The limits of detection (LODs) were between 69.1 and 337 nM. The influences of sheath liquid composition, nebulizing gas pressure and drying gas temperature on the separation were examined.  相似文献   

18.
A potent and selective sulfonamide beta3 agonist with an excellent pharmacokinetic profile has recently been synthesized. During the analysis by liquid chromatography/tandem mass spectrometry (LC/MS/MS) of metabolites of the sulfonamide N-[4-[2-(2-hydroxy-2-pyridin-3-ylethylamino)ethyl]phenyl]-4-[4-(4-trifluoromethylphenyl)thiazol-2-yl]benzulfonamide (compound A), we observed loss of 64 Da for a few of the metabolites in the negative ion mode. Accurate mass measurements performed with Fourier transform ion cyclotron resonance (FTICR) mass spectrometry and quadrupole time-of-flight (Q-TOF) mass spectrometry suggested that the loss of 64 Da corresponded to the loss of SO(2). The same phenomenon was observed for a group of structurally related and commercially available compounds that also contain a sulfonamide moiety. MS/MS analysis of the fragment ions that had lost SO(2) in the ion source suggested that these ions were covalently bound rather than ion-molecule complexes. The neutral loss involving the cleavage of two bonds was unanticipated and suggested a complex rearrangement process. A mechanism for the loss of SO(2) has been proposed.  相似文献   

19.
A capillary electrophoresis/mass spectrometry method for the simultaneous chiral analysis of enantiomers of methamphetamine (MA), amphetamine (AP), dimethylamphetamine (DMA), ephedrine (EP), norephedrine (NE) and methylephedrine (ME) in urine has been developed. The background electrolyte was 1 M formic acid (pH 1.7). Using 0.85 mM heptakis(2,6-diacethyl-6-sulfato)-beta-cyclodextrin as the chiral selector, the 12 enantiomers were completely separated within 25 min. The detection limits were 0.01 microg mL(-1) for the enantiomers of MA, AP, DMA, EP and ME, and 0.02 microg mL(-1) for the enantiomers of NE using selected ion monitoring. The reproducibilities of within-run (n = 4) for the migration times and peak areas of the standard mixture were under 0.58% and 7.83%, respectively. The calibration curves of the peak areas of the 12 enantiomers were linear in the range of 0.05 - 10 microg mL(-1). This method was applicable to the analysis of urine samples.  相似文献   

20.
A capillary electrophoresis (CE) method coupled to electrospray ionization ion trap tandem mass spectrometry (ESI-IT-MS/MS) is described for the rapid analysis of carnitine, acetylcarnitine, and propionylcarnitine in human plasma. Optimization of the procedure was achieved by a reduced sample pretreatment and after examining several physicochemical parameters that influence both the CE separation and the MS analytes detection. The analysis of total carnitine in human plasma after hydrolysis of short-chain metabolites is also shown. The analysis of carnitine and metabolites was obtained in less than 10 min using a 200 mM ammonium formate buffer, pH 2.5, with high sensitivity and specificity using the MS detection in product ion scan mode. The method was tested for quantitative recovery using dialyzed human plasma as matrix and showed linearity in the concentrations ranges 20–160, 1–32, and 0.25–8 μM for carnitine, acetylcarnitine, and propionylcarnitine with (squared) correlation coefficients of 0.9984, 0.9995, and 0.9991, respectively. The intraday and intermediate analysis repeatability and accuracy are within 15% of relative standard deviation (RSD) at low, medium, and high concentration and within/or slight exceeding 20% at the lower limit of quantitation (LLOQ). The method is sensitive for determining carnitine and its metabolites in human plasma with high specificity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号