首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 22 毫秒
1.
A specific and sensitive method based on tandem mass spectrometry with on-line high-performance liquid chromatography using atmospheric pressure chemical ionisation (LC–APCI-MS–MS) for the quantitation of anabolic hormone residues (17β-19-nortestosterone, 17β-testosterone and progesterone) and their major metabolites (17-19-nortestosterone and 17-testosterone) in bovine serum and urine is reported. [2H2]17β-Testosterone was used as internal standard. The analytes were extracted from urine (following enzymatic hydrolysis) and serum samples by liquid–liquid extraction and purified by C18 solid-phase extraction. Ionisation was performed in a heated nebulizer interface operating in the positive ion mode, where only the protonated molecule, [M+H]+, was generated for each analyte. This served as precursor ion for collision-induced dissociation and two diagnostic product ions for each analyte were identified for the unambiguous hormone confirmation by selected reaction monitoring LC–MS–MS. The overall inter-day precision (relative standard deviation) ranged from 6.37 to 2.10% and from 6.25 to 2.01%, for the bovine serum and urine samples, respectively, while the inter-day accuracy (relative error) ranged from −5.90 to −3.18% and from −6.40 to −2.97%, for the bovine serum and urine samples, respectively. The limit of quantitation of the method was 0.1 ng/ml for all the hormones in bovine serum and urine. On account of its high sensitivity and specificity the method has been successfully used to confirm illegal hormone administration for regulatory purposes.  相似文献   

2.
This paper reports an experimental design optimization of a recently proposed silylation procedure that avoids the introduction of false positives and false negatives in the simultaneous determination of steroid hormone estrone (E1) and 17-alpha-ethinylestradiol (EE2) by gas chromatography-mass spectrometry (GC/MS). The figures of merit for several calibration procedures were evaluated under optimum conditions in the silylation step. Internal standardization strategies were applied and global models were constructed by gathering signals recorded on three non-consecutive days. Three calibration models were examined: a univariate model with a sum of six monitorized ions and a three-way PARAFAC-based model (the analyte scores were standardized on the basis of the scores of the internal standard). The global PARAFAC-based calibration model showed the best performance with detection capabilities of 4.3 microg l(-1) and 7.0 microg l(-1) for E1 and EE2, respectively, when the probability of false positives was fixed at 1% and that of false negatives at 5%. Mean relative error in absolute terms for E1 and for EE2 was 11.1% and 8.5%, respectively, and trueness was likewise confirmed. The proposed optimized derivatization procedure using a three-way calibration function was also applied in the determination of E1, 17-beta-estradiol (E2) and EE2 in bovine urine samples: recovery values were 68.5%, 40.4% and 43.4%, respectively, and the detection capability was 18.4, 19.3 and 18.6 microg l(-1) when the probability of false positives was fixed at 1% and that of false negatives at 5%. Mean relative error in absolute terms for E1, E2 and EE2 was 7.4%, 9.4% and 8.6%, respectively, and trueness was likewise confirmed.  相似文献   

3.
A sensitive electrochemical enzyme-linked immunosorbent assay (ELISA) for the detection of 17 beta-estradiol (17 beta-E2) was developed. Optimisation of two ELISA competition assays, using monoclonal or polyclonal antibodies anti-17 beta-estradiol, coupled with the electrochemical detection was firstly performed. The activity of the label enzyme (horseradish peroxidase) was measured electrochemically using 3,3',5,5'-tetramethylbenzidine as substrate. The use of the polyclonal antibody resulted in a more sensitive assay and the detection limit of the assay was estimated to be 20 pg ml-1. The analytical performances of the method were compared to those obtained using a dissociation enhanced lanthanide fluorescence immunoassay (DELFIA). Although sample extraction is not usually required by DELFIA, both extracted and non extracted samples were assayed. The comparison between the two screening techniques revealed similar results for the extracted samples and showed a comparable precision (RSD%), ranging from 6.2 to 13.4 and from 6.7 to 14.3 for DELFIA and ELISA, respectively. The results obtained by these screening assays were confirmed by liquid chromatography atmospheric pressure chemical ionisation tandem mass spectrometry which is currently used to confirm illegal hormone administration for regulatory purposes. The electrochemical enzyme immunoassay appears suitable as a screening tool for routine analysis of bovine serum estradiol and can be extended to other anabolic hormones using appropriate antibodies.  相似文献   

4.
采用气相色谱-质谱联用技术(GC-MS),以N,O-双三甲基硅基三氟乙酰胺为衍生化试剂,系统研究了4种类固醇类环境内分泌干扰物雌酮(E1)、17β-雌二醇(E2)、雌三醇(E3)、17α-乙炔基雌二醇(EE2)的羟基衍生化行为,考察了BSTFA用量、衍生化温度和时间对类固醇类环境内分泌干扰物衍生化效果的影响以及衍生化产物的稳定性、标准曲线、仪器检出限等,并对衍生化产物特征碎片离子的裂解机理进行了解释.结果表明:对于100 μL 0.01 g/L标准混合溶液,BSTFA的最佳用量为25 μL;衍生化过程不需要加热,常温下(20 ℃)下反应10 min就可取得最佳的衍生化效果;衍生化产物的稳定性较好,在-20 ℃下放置48 h,相对响应因子RRF基本没有降低.在优化的实验条件下,各待测物具有良好的线性相关性,E1和E2的检出限为0.3 μg/L,EE2和E3的检出限为5 μg/L.  相似文献   

5.
A novel flow injection method with resonance light scattering detection was developed for the determination of total protein concentrations. This method is based on the enhancement of RLS signals from Methyl Blue (MB) by protein. The enhanced RLS intensities at 333 nm, in a pH 4.1 acidic aqueous solution, were proportional to the protein concentration over the range 2.0-37.3 and 1.0-36.0 microg ml-1 for human serum albumin (HSA) and bovine serum albumin (BSA), respectively. The corresponding limits of detection (3sigma) of 45 ng ml-1 for HSA and 80 ng ml-1 for BSA were attained. The method was successfully applied to the quantification of total proteins in human serum samples, the maximum relative error is less than 1% and the recovery is between 98% and 102%. The sample throughput was 60 h-1.  相似文献   

6.
A new confirmatory method for three macrolides (tylosin, tilmicosin and erythromycin) in bovine muscle, liver and kidney by micro-LC-MS-MS using an atmospheric pressure ionisation source and an ionspray interface has been developed. Roxithromycin was used as internal standard. The molecular related ions, [M+2H]2+, at m/z 435 for tilmicosin, and [M+H]+, at m/z 734 and 916 for erythromycin and tylosin, respectively, were the precursor ions for collision-induced-dissociation and two diagnostic product ions for each macrolide were identified for the unambiguous confirmation by selected reaction monitoring LC-MS-MS. Precision values (relative standard deviations) were all below 14.9%, whereas the overall accuracy (relative error) ranged from -17.7 to -9.8% for tylosin, from -17.5 to -10.7% for tilmicosin and from -19.6 to -13.7% for erythromycin, in all the investigated bovine tissues. The limits of quantification were 30 (muscle) or 40 (liver, kidney) microg kg(-1), 20 (muscle) or 150 (liver, kidney) microg kg(-1), 50 (muscle, liver) or 80 (kidney) microg kg(-1), 20 (muscle, liver) or 50 (kidney) microg kg(-1) for tylosin, tilmicosin, erytromycin and roxithromycin, respectively.  相似文献   

7.
Liu X  Liu R  Tang Y  Zhang L  Hou X  Lv Y 《The Analyst》2012,137(6):1473-1480
In this work, antibody goat anti-human IgG as a scaffold was employed for the synthesis and biofunctionalization of HgS nanoparticles (NPs) via a facile one-pot process. After a complete sandwich-type immunoreaction among primary antibody, human IgG and secondary antibody labeled with HgS NPs, a large number of mercury ions released from captured HgS NPs dissolution were quantitatively detected by chemical vapor generation atomic fluorescence spectrometry (CVG-AFS). Taking advantage of the signal amplification property of HgS NPs and the high sensitivity of CVG-AFS, the assay detected human IgG with a limit of detection (S/N = 3) of 0.6 ng mL(-1) (4.0 fmol mL(-1) or 0.4 fmol) and the response was linear over a dynamic range from 1.0 to 5.0 × 10(4) ng mL(-1) with a correlation coefficient of 0.996. A relative standard deviation (RSD) of 1.0 × 10(2) ng mL(-1) human IgG was 1.5% for within-batch (intra-assay) and 4.5% for between-batch (inter-assay). Other proteins, such as goat anti-rabbit IgG, goat anti-human IgG, rabbit anti-human IgG, carcinoembryonic (CEA), α-fetoprotein (AFP), human serum albumin (HSA) and bovine serum albumin (BSA) did not significantly interfere with the assay for human IgG. The analytical result of HgS NPs with AFS-based immunoassay technology for the quantification of human IgG in human serum from patients is in good agreement with the result obtained by conventional immunoturbidimetric method. The consequence shows that the novel immunosensor possessed satisfactory precision, extremely high sensitivity, high selectivity and could be applied for the quantification analysis of real samples.  相似文献   

8.
Disposal of animal wastes comprises a primary source of hormones present in the environment. Accurate quantification of hormones in animal wastes is essential to assess the potential risk associated with waste disposal, but represents a significant challenge. In this study, high performance liquid chromatography (HPLC) coupled with fluorescence detection was used to analyse 17β-estradiol (E2) and 17α-ethinylestradiol (EE2) in poultry litter. This method involves the use of dichloromethane/methanol (2:1, v/v) mixture to extract the analytes from litter matrix followed by a clean-up procedure using normal-phase open column chromatography to remove lipid contents. Three different types of normal-phase media (commercial silica gel, commercial florisil gel, and self-packed silica gel) were tested and compared for clean-up efficiency. Silica gel was selected and recovery ratios of 73% and 57% were achieved for E2 and EE2, respectively. Detection limits were 4.0 μg/kg and 2.6 μg/kg for E2 and EE2, respectively. Using this method, E2 in stacked broiler litter at different depths and over different stacking times was analysed. It was found that the E2 concentration was as high as 719 μg/kg in the top layer of the litter pile and tends to be lower in deeper layers. We also found that the E2 concentrations decreased significantly over time.  相似文献   

9.
An analytical method is presented which permits trace level determination of 17alpha-ethynylestradiol (EE2), 17beta-estradiol (E2), and estrone (E1). Using this method, the estrogenic steroids were analyzed in drinking water, surface water, and wastewater (sewage influents and effluents) at concentrations down to 0.1 ng/L. Sample volumes between 100 and 500 mL are concentrated using automated solid-phase extraction. Analysis is performed by liquid chromatography with detection by tandem mass spectrometry. Applying simple clean-up procedures and internal standard calibration, recovery losses resulting from matrix-dependent ion suppression during electrospray ionization could be compensated for all of the investigated compounds. Recoveries around 100% were obtained for all analytes after correction using the internal standards. Limits of quantification (LOQ) were between 0.1 and 0.4 ng/L for purified sewage, surface, ground, and drinking water and between 1 and 2 ng/L in the case of raw sewage. Water treatment by wastewater treatment plants (WWTPs) or by a surface water treatment plant affected the removal of all estrogenic steroids. Thus, E1, E2, and EE2 were removed in the municipal WWTPs to the extent of 93%, 93%, and 80%, respectively. In the effluents of the WWTP in Ruhleben (Berlin, Germany), E1, E2, and EE2 were detected at the low ng/L level. E2 and EE2 were, however, not present in the Berlin surface water above the LOQ (0.2 ng/L). E1 was the only compound that could be detected in surface water samples. After additional surface water treatment it was still detectable but only at trace-level concentrations with a mean value of 0.16 ng/L.  相似文献   

10.
Poly(butylene succinate) (PBSu), poly(butylene succinate-co-adipate) (PBSA) and poly(butylene terephthalate-co-adipate) (PBTA) microcapsules were prepared by the double emulsion/solvent evaporation method. The effect of polymer and poly(vinyl alcohol) (PVA) concentration on the microcapsule morphologies, drug encapsulation efficiency (EE) and drug loading (DL) of bovine serum albumin (BSA) and all-trans retinoic acid (atRA) were all investigated. As a result, the sizes of PBSu, PBSA and PBTA microcapsules were increased significantly by varying polymer concentrations from 6 to 9%. atRA was encapsulated into the microcapsules with an high level of approximately 95% EE. The highest EE and DL of BSA were observed at 1% polymer concentration in values of 60 and 37%, respectively. 4% PVA was found as the optimum concentration and resulted in 75% EE and 14% DL of BSA. The BSA release from the capsules of PBSA was the longest, with 10% release in the first day and a steady release of 17% until the end of day 28. The release of atRA from PBSu microcapsules showed a zero-order profile for 2 weeks, keeping a steady release rate during 4 weeks with a 9% cumulative release. Similarly, the PBSA microcapsules showed a prolonged and a steady release of atRA during 6 weeks with 12% release. In the case of PBTA microcapsules, after a burst release of 10% in the first day, showed a parabolic release profile of atRA during 42 days, releasing 36% of atRA.  相似文献   

11.
The highly complex matrix of activated sludge in sewage treatment plants (STPs) makes it difficult to detect endocrine-disrupting chemicals (EDCs) which are usually present at low concentration levels. To date, no literature has reported the concentrations of steroid estrogens in activated sludge in China and very limited data are available worldwide. In this work, a highly selective and sensitive analytical method was developed for simultaneous determination of two classes of EDCs, including estrone (E1), 17β-estradiol (E2), estriol (E3), 17α-ethynylestradiol (EE2), 4-nonylphenol (NP) and bisphenol A (BPA), in the liquid and solid phases of activated sludge. The procedures for sample preparation, extracts derivatization, and gas chromatography–mass spectrometry (GC–MS) quantification were all optimized to effectively determine target EDCs while minimizing matrix interference. The developed method showed good calibration linearity, recovery, precision, and a low limit of quantification (LOQ) for all selected EDCs in both liquid and solid phases of activated sludge. It was successfully applied to determine the concentrations of EDCs in activated sludge samples from two STPs located in Beijing and Shanghai of China, respectively.  相似文献   

12.
Li XF  Ma M  Scherban K  Tam YK 《The Analyst》2002,127(5):641-646
A liquid chromatographic-electrospray mass spectrometric method was developed for the determination of ginkgolides and bilobalide and was applied to the analysis of commercial products of Ginkgo biloba leaf extracts. Adducts of these compounds with ammonium, proton and sodium were detected and their relative abundance depended on the electrospray fragmentor voltage. The relative standard deviation (RSD) was improved from > 17% to < 6%, when three adduct ions of (M + H)+, (M + NH4)+ and (M + Na)+ were used for quantification compared with single ion monitoring. The characteristic mass spectra of bilobalide were different from those of ginkgolides; in particular, dimers of (2M + Na)+ were observed for bilobalide only. Analysis of 26 commercial ginkgo products revealed large variations in the composition and concentrations of ginkgolides and bilobalide in herbal products.  相似文献   

13.
A reliable method for the confirmation of the synthetic hormone stanozolol and its major metabolite, 16beta-hydroxystanozolol, in bovine urine by liquid chromatography coupled with tandem mass spectrometry has been developed. [2H3]Stanozolol was used as internal standard. Sample preparation involved enzymatic hydrolysis, liquid-liquid extraction and purification on an amino solid-phase extraction column. The analytes were ionized using atmospheric pressure chemical ionization with a heated nebulizer interface operating in the positive ion mode, where only the protonated molecules, [M+H]+, at m/z 329 and m/z 345, for stanozolol and 16beta-hydroxystanozolol, respectively, were generated. These served as precursor ions for collision-induced dissociation and three diagnostic product ions for each analyte were identified for the unambiguous hormone confirmation by selected reaction monitoring liquid chromatography-tandem mass spectrometry. The accuracy ranged from 19.7 to 14.9% and from 18.9 to 13.2% for stanozolol and 16beta-hydroxystanozolol, respectively. The precision ranged from 12.4 to 2.4% and from 13.1 to 1.8% for stanozolol and 16beta-hydroxystanozolol, respectively. The limit of quantification of the method was 1 ng/ml in the bovine urine for both stanozolol and 16beta-hydroxystanozolol. The developed method fulfils the European Union requirements for confirmatory methods.  相似文献   

14.
This paper reports the assembly of a disposable immunosensor based on the direct competitive enzyme-linked immunosorbent assay (ELISA), for simple and fast measurement of 17β-estradiol (17β-E2) in bovine serum, using screen-printed electrodes (SPEs) and a Palm-Sens portable electrochemical detector. The immunosensor strip was assembled immobilising, by passive adsorption, anti-rabbit IgG onto the surface of the working SPE electrode. After the interaction between anti-rabbit IgG and rabbit anti-17β-E2 polyclonal antibodies (PAb), the competition was performed using 17β-estradiol-alkaline phosphatase conjugate (17β-E2-AP) synthesised in our laboratory. The enzymatic substrate used for signal generation was 1-naphthylphosphate and its conversion to an electroactive product (1-naphthol) was measured using differential pulse voltammetry (DPV). To develop a prototype for field measurements, the entire competitive protocol has been optimised directly in a blank non-extracted bovine serum.According to the new EU criteria established by the Commission Decision 2002/657/EC for qualitative and quantitative screening methods, the detection capability (CCβ), was determined. The CCβ value resulted below the action limit (40 pg mL−1) fixed for 17β-E2.Spiked and real samples were analysed using the electrochemical immunostrips obtaining precision values (relative standard deviation, R.S.D.%) ranging from 8.6 to 17.0% and a recovery (R%) from 88.2 to 120.0%.Results obtained on real samples were confirmed by liquid chromatography coupled on-line with tandem mass spectrometry (LC-MS/MS) using an atmospheric pressure chemical ionisation (APCI) source and a heated nebulizer (HN) interface; this is the method currently used to confirm illegal hormone administration for regulatory purposes. The disposable immunosensor appears suitable as a screening tool for field analysis of bovine serum estradiol.  相似文献   

15.
Ocaña JA  Barragán FJ  Callejón M 《The Analyst》2000,125(12):2322-2325
A spectrofluorimetric method to determine the antibiotic moxifloxacin is proposed and was applied to pharmaceuticals, human urine and serum. The fluorimetric method allows the determination of 30-300 ng mL-1 moxifloxacin in aqueous solution containing phosphoric acid-phosphate buffer (pH 8.3) with lambda exc = 287 nm and lambda em = 465 nm. Detection and quantification limits were 10 and 30 ng mL-1, respectively, with a relative standard deviation (n = 10) of 2%. This method was applied to the determination of moxifloxacin in three Spanish commercial pharmaceutical formulations. Another variant of the method in micellar medium allows the direct measurement of moxifloxacin in human serum and urine by standard additions. The enhanced fluorescence of moxifloxacin in 8 mM sodium dodecyl sulfate (SDS) solution at pH 4.0 (acetic acid-acetate buffer) for lambda exc = 294 nm and lambda em = 503 nm shows the same linear range as the aqueous method with a 25% lower slope (with detection and quantification limits of 15 and 60 ng mL-1, respectively, and a relative standard deviation of 1.3%), but permits the background fluorescence for urine and serum blanks to be minimized. Hence, sufficient sensitivity is reached to determine therapeutic concentrations of the drug in urine (average recovery 102 +/- 2%) and serum (average recovery 105 +/- 2%) samples.  相似文献   

16.
A method based on gas chromatography (GC) separation followed by ion trap tandem mass spectrometry detection in EI mode (ITD-MS/MS), using isotope dilution, was developed for the determination of ten native polybrominated diphenyl ethers (PBDEs) and four (13)C(12)-labeled congeners in biological (fat tissue and human serum) and food samples. The highest-mass fragment ions were used as precursor ions for those congeners with molecular ions with m/z values higher than the maximum of the instrument. In these cases (hepta-BDEs and (13)C(12)-hexa-BDEs) no fragmentation was achieved under the experimental conditions employed. Repeatability (lower than 9%) and reproducibility (lower than 13%), expressed as relative standard deviation (RSD, n = 3 and 4, respectively), were satisfactory. Similarly, the coefficient of variation (n = 4) of the isotopic ratio between the two most abundant product ions was lower than 10 and 6% for native and labeled congeners, respectively. To evaluate the feasibility of the method, the optimized isotope dilution GC/ITD-MS/MS method was used for the quantitation of selected PBDE congeners in different samples including adipose tissue, human serum and foodstuff samples, from three inter-laboratory comparative exercises, covering a wide range of concentrations. A solid-phase extraction procedure, previously developed for PCB determination in small-size bird serum samples, was successfully applied to quantification of PBDEs in 1 mL samples of human serum.  相似文献   

17.
Steroid determination by immunoassays results in significant interferences and inaccurate results. This study describes the development and validation of a new gas chromatographic-mass spectrometric method for the simultaneous quantification of 17alpha-hydroxyprogesterone (17alphaOHP), testosterone (T), dehydroepiandrosterone (DHEA), androstenedione (Delta4-A), cortisol (F) and pregnenolone (Preg) in serum of neonates. Steroids were extracted and purified from 0.5 mL serum using diethyl ether and Extrelut mini NT1 column. The extracts were derivatized with N-methyl-N-trimethylsilyl-trifluoroacetamide (MSTFA)/trimethylsilyl iodide (TMSI)/dithioerythritol (DTE) and the resulting trimethylsilyl derivatives were quantified by gas chromatography-selected ion monitoring-mass spectrometry (GC-SIM-MS). The detection limit for all steroids was lower than 0.1 ng/mL. The limit of quantification was 0.1 ng/mL for all steroids except cortisol which was at 0.25 ng/mL. d3-Testosterone and methyltestosterone served as internal standards. Precision for all compounds at the concentrations of 0.5, 1, 5 and 10 ng/mL (n = 10) in fortified steroid-free serum samples ranged from 0.8% to 16.6%. Accuracy was calculated at the concentrations of 0.5, 1, 5 and 10 ng/mL and ranged from -9.2% to 10.6% (n = 10). Linear calibration equations were obtained for all five steroids (0.125-31.25 ng/mL) and for cortisol (0.125-200 ng/mL). Relative recoveries at concentrations 1.0 and 12.5 ng/mL ranged from 70.5% to 97.5%. Absolute recoveries at the same concentrations ranged from 73.2% to 96.6%. Reference intervals were estimated for infants aged from 9 to 40 days. The proposed steroid profile is suitable for routine analysis and provides meaningful data for samples within normal range as well as those with elevated levels.  相似文献   

18.
Protein quantification based upon mass spectrometry is gaining ground in diverse applications of biological and clinical relevance. The present article focuses on one of the most complex biological fluids - serum - and provides a novel ICPL based quantification protocol. The results are compared to a label-free (data independent alternate scanning) absolute quantification method. The validation is performed using MRM based protein quantification technique. Regarding the ICPL approach, serum samples used in this study were depleted of high abundant proteins, labeled with ICPL and fractionated according to their respective pI (3-5, 5-7 and 7-12). The samples were further subjected to tryptic digestion followed by treatment with the Glu-C enzyme. The peptides were analyzed on a 2D-nano-LC system using four different concentrations of salt injections (45, 75, 150 and 500 mM ammonium acetate). The LC system was connected on-line with the electrospray ion-trap mass spectrometer. For the label-free quantification the serum samples were depleted and digested with trypsin. A proteome-wide comparison was performed using highly reproducible LC and data independent alternate scanning in conjunction with a high mass accuracy orthogonal time-of-flight mass spectrometer. Selected proteins, found by both methods, were validated using the MRM approach. For this purpose non-depleted tryptically digested serum samples were analyzed by LC coupled with a triple-quadrupole MS. The relative protein quantification using ICPL and mass spectrometry allowed for the detection of approximately 200 proteins, whereas about 2/3 of those contained the ICPL label and could therefore be quantified. Label-free approach used no fractionation, less sample and was able to identify and quantify over 110 proteins. The identified proteins covered generally 3-4 orders of magnitude of protein concentration in human serum. Changes in relative abundance of eight proteins were validated using MRM. This study, for the first time, shows the ability of the relative protein quantification based upon ICPL and 2D-LC-MS/MS to quantify serum biomarkers. It provides two additional label-free approaches that could validate and bring additional value to the label-based results, offering a starting point for comprehensive proteomics studies aiming at revealing biomarkers of clinical relevance.  相似文献   

19.
A new and simple method for the determination of fat-soluble vitamins (retinol, alpha-tocopherol, and beta-carotene) in human serum was developed and validated by using liquid chromatography-tandem mass spectrometry with atmospheric pressure chemical ionization (LC-APCI-MS-MS). Different solvent mixtures were tested to obtain deproteinization and extraction of the analytes from the matrix. As a result, a volume of 240 microL of a 1:1 (v/v) ethanol/ethyl acetate mixture added to 60 microL of serum was found to be suitable for both protein precipitation and antioxidants solubilization, giving the best recovery for all three analytes. Deproteinized samples (20 microL) were injected after dilution, without the need for concentration or evaporation to dryness and reconstruction of the sample. Vitamins were separated on a C-8 column using a 95:5 (v/v) methanol/dichloromethane mixture and ionized in the positive-ion mode; detection was performed in the selected-reaction monitoring mode. Linearity of the LC-APCI-MS-MS method was established over 5 orders of magnitude for retinol and alpha-tocopherol, whereas in the case of beta-carotene it was limited to 4 orders. Lower limits of quantitation were 1.7, 2.3, and 4.1 nM for retinol, alpha-tocopherol, and beta-carotene, respectively. Serum concentrations of retinol, alpha-tocopherol, and alpha+beta-carotene determined in a group of healthy volunteers were 2.48, 38.07, and 0.50 microM, respectively, in samples collected in winter ( n=122) and 2.69, 45.88, and 0.90 microM during summer ( n=66).  相似文献   

20.
A novel approach to the determination of 17beta-estradiol in bovine plasma is presented. The observed enhanced sensitivity is gained by the application of tandem mass spectrometry (MS) fragmentation to a stable, well characterized negative ion produced by chemical ionization (methane as reagent gas). A specific derivatizing reactant is employed (pentafluorobenzyl bromide), combined with bis-trimethylsilyltrifluoroacetamide, to favor the formation of a diagnostic precursor negative ion. Plasma samples are purified through a C18 solid phase extraction column and derivatized before gas chromatography-MS analysis. The accuracy and the precision of the method, tested over a set of spiked samples, were satisfactory. The limit of detection was found to be 5 pg ml(-1) and the limit of quantification was fixed at 20 pg ml(-1). The fragmentation pattern is fully explained and the method is applicable for the official analysis of bovine plasma for the detection of 17beta-estradiol according to the European criteria 256/93 and to the draft SANCO/1805/2000 rev. 3. The quantification of incurred positive samples was performed according to the proposed procedure and compared with the results obtained by standardized radio immuno assay; the estimated concentrations were significantly similar.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号