1.
用电聚合法制备了聚L-组氨酸修饰碳黑微电极,研究了多巴胺在该修饰电极上的电化学行为。实验表明:该修饰电极对神经递质多巴胺的电化学氧化有显著的催化作用,采用二次导数线性扫描伏安法对多巴胺进行测定,在pH 7.0的磷酸盐缓冲溶液中,多巴胺在0.15 V处产生一灵敏的氧化峰,多巴胺的氧化峰电流与浓度在4.0×10-8~1.0×10-4mol/L范围内呈线性关系,检出限(3σ)为1.0×10-8mol/L。该聚合物修饰电极具有良好的选择性,能有效地排除抗坏血酸对测定的影响,用于人工合成样品的分析。  相似文献   

2.
The development of a highly sensitive amperometric sensor for nitrite using a glassy carbon electrode modified with alternated layers of iron(III) tetra-(N-methyl-4-pyridyl)-porphyrin (FeT4MPyP) and cobalt(II) tetrasulfonated phthalocyanine (CoTSPc) is described. The modified electrode showed an excellent catalytic activity and stability for the nitrite oxidation decreasing the peak potentials about 200 mV toward less positive values and presenting much higher peak currents than those obtained on the bare GC electrode. A linear response range of 0.2-8.6 μmol l−1, with a sensitivity of 0.37 μA l μmol−1 and detection limit of 0.04 μmol l−1 were obtained with this sensor. The repeatability of the proposed sensor, evaluated in term of relative standard deviation, was verified to be 1.4% for 10 measurements of 0.2 μmol l−1 nitrite solution. Interference caused by common ions has been investigated in simulated mixtures containing high concentration level of interfering ions and the sensor was found to be tolerant against these ions. The developed sensor was applied for the nitrite determination in water samples and the results were in agreement with those obtained by a comparative method described in the literature. The average recovery for these samples was 100.1 (±0.7)%.  相似文献   

3.
Mesoporous carbon ceramic SiO2/50 wt % C (SBET=170 m2 g?1), where C is graphite, were prepared by the sol‐gel method. The materials were characterized using N2 sorption isotherms, scanning electron microscopy, and conductivity measurements. The matrix was used as support for the in situ immobilization of Mn(II) phthalocyanine (MnPc) on their surface. XPS was used to determine the Mn/Si atomic ratios of the MnPc‐modified materials. Pressed disk electrodes were prepared with the MnPc‐modified matrix, and tested as an electrochemical sensor for nitrite oxidation. The linear response range, sensitivity, detection limit and quantification limit were 0.79–15.74 µmol L?1, 17.31 µA L µmol?1, 0.02 µmol L?1 and 0.79 µmol L?1, respectively, obtained using cyclic voltammetry. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation was 1.7 % for 10 measurements of a solution of 12.63 µmol L?1 nitrite. The sensor employed to determine nitrite in sausage meat, river and lake water samples showed to be a promising tool for this purpose.  相似文献   

4.
A nafion covered carbon nanotubes-paste electrode modified with poly(m-ferrocenylaniline), (Nf/p(FcAni)-CNTsPE), provides a novel voltammetric sensor for the selective determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA). We studied the electrochemical activity of Nf/p(FcAni)-CNTsPE toward DA, UA, and AA by differential pulse voltammetry (DPV). DA and UA anodic peaks appear at 0.30 and 0.45 V, respectively while an anodic peak for AA was not observed. DPV oxidation peak values are linearly dependent on DA concentration over the range 1–150 μM (r2 = 0.992), and on UA concentration over the range 5–250 μM (r2 = 0.997). DA and UA detection limits are estimated to be 0.21 and 0.58 μM, respectively. The modified electrode shows both good selectivity and reproducibility for the selective determination of DA and UA in real samples. Finally, the modified electrode was successfully applied for the determination of DA and UA in pharmaceutical or biological sample fluids.  相似文献   

5.
A series of cross-linked poly(2-hydroxyethylmethacrylate) (polyHEMA) films doped with 1,2-diaminoanthraquinone (DAQ) are described. The synthesis of the DAQ-containing polymers does not require any previous derivatization of the diamine. The films can be used as solid-state colorimetric sensors for nitrite anion as well as for aqueous and gaseous nitric oxide. Polymers show no appreciable leaching of DAQ even after six months of storage in water.  相似文献   

6.
卢丽敏  徐景坤 《高分子科学》2014,32(8):1019-1031
A novel graphene oxide doped poly(hydroxymethylated-3,4-ethylenedioxythiophene)(PEDOT-MeOH/GO) composite film was synthesized and utilized as an efficient electrode material for simultaneous detection of rutin and ascorbic acid(AA). PEDOT-MeOH/GO films were synthesized on glassy carbon electrode(GCE) by a facile one-step electrochemical approach and were characterized by scanning electron microscopy, UV-Vis spectroscopy, FTIR spectra and electrochemical methods. Then the PEDOT-MeOH/GO/GCE was applied successfully in the simultaneous detection of rutin and AA. The results showed that the oxidation peak currents of rutin and AA obtained at the PEDOT-MeOH/GO/GCE were much higher than those at the traditional conducting polymer PEDOT/GO/GCE, PEDOT-MeOH/GCE, PEDOT/GCE and bare GCE. Under optimized conditions, the linear ranges for rutin and AA are 20 nmol/L-10 μmol/L and 8 μmol/L-1 mmol/L, respectively. The detection limit is 6 nmol/L for rutin and 2 μmol/L for AA(S/N = 3), which are lower than those of the reported electrochemical sensors.  相似文献   

7.
A simple and very selective electrode, based on a mercury ion imprinted polymer (IIP), and its application for the determination of Hg2+ ions in the real samples is introduced. Mercury ion selective cavities were created in the vinyl pyridine based cross-linked polymer. In order to fabricate the sensor carbon particles and polymer powder were mixed with melted n-eicosane. An explicit difference was observed between the responses of the electrodes modified with IIP and non imprinted polymer (NIP), indicating proper performance of the recognition sites of the IIP. Various factors, known to affect the response behavior of selective electrode, were investigated and optimized. The interference of different ionic species with the response of the electrode was also studied. The results revealed that, compared to previously developed mercury selective sensors, the proposed sensor was more selective, regarding the common potential interferer. This sensor showed a linear response range of 2.5 × 10−9–5.0 × 10−7 M and lower detection limit of 5.2 × 10−10 M (S/N). The sensor was successfully applied to the determination of mercury in real samples.  相似文献   

8.
This work describes the promising activity of silver nanoparticles on the surface of a poly(2-amino diphenylamine) modified carbon paste electrode (CPE) towards formaldehyde oxidation. Electrodeposition of the conducting polymer film on the CPE was carried out using consecutive cyclic voltammetry in an aqueous solution of 2-aminodiphenylamine and HCl. Nitrogen groups in the polymer backbone had a Ag ion accumulating effect, allowing Ag nanoparticles to be electrochemically deposited on the surface of the electrode. The electrochemical and morphological characteristics of the modified electrode were investigated. The electro-oxidation of formaldehyde on the surface of electrode was studied using cyclic voltammetry and chronoamperometry in aqueous solution of 0.1 mol/L NaOH. The electro-oxidation onset potential was found to be around -0.4 V, which is unique in the literature. The effect of different concentrations of formaldehyde on the electrocatalytic activity of the modified electrode was investigated. Finally, the diffusion coefficient of formaldehyde in alkaline media was calculated to be 0.47 × 10-6 cm2/s using chronoamperometry.  相似文献   

9.
Electrochemistry of water-soluble cobalt(II) tetrasulfophthalocyanine (CoTSPc) electrodeposited on glassy carbon nanotube pre-modified with acid-functionalized multi-walled carbon nanotubes (MWCNT) is described. Both charge transfer resistances toward [Fe(CN)6]3−/4− redox probe and electrocatalytic responses toward epinephrine (EP) detection follow the trend: bare GCE < GCE-MWCNT < GCE-CoTSPc < GCE-MWCNT-CoTSPc. EP analysis was then carried out in details using GCE-MWCNT-CoTSPc. The catalytic rate constant value k ch = 2.2 × 107 (mol cm−3)−1 s−1 was obtained from rotating disk electrode experiment. Interestingly, GCE-MWCNT-CoTSPc efficiently suppressed the detection of ascorbic acid (the natural interference of neurotransmitters in physiological conditions) showing good sensitivity (0.132 ± 0.003 A l mol−1), limit of detection (4.517 × 10−7 mol l−1), and quantification (15.056 × 10−7 mol l−1). In addition, GCE-MWCNT-CoTSPc was conveniently used to determine EP in epinephrine hydrochloric acid injection with recovery of 101.1 ± 2.2%.  相似文献   

10.
ABSTRACT

A modified carbon paste electrode has been developed for the determination of Pb(ΙΙ) ions based on Fe3O4/eggshell magnetic nanocomposite. The structure and morphology of Fe3O4/eggshell were analysed by X-ray diffraction (XRD) and scanning electron microscopy (SEM). The prepared nanocomposite was also characterized by Fourier transform infrared spectroscopy (FT-IR) and vibrating sample magnetometer (VSM). The electrochemical procedure was based on the accumulation and determination of Pb(ΙΙ) ions at the surface of the modified carbon paste electrode with Fe3O4/eggshell nanocomposites and carbon nanotubes by differential pulse anodic stripping voltammetry (DPASV). Various experimental parameters involved in the preconcentration of Pb(ΙΙ) ions and voltammetric stripping step were studied. Under the optimum conditions, the voltammetric peak current of Pb(ΙΙ) occurs at a potential about ?0.5 V. Also, the voltammetric peak current increased linearly with Pb(ΙΙ) concentration in the range of 0.5–200 ng mL?1 and a detection limit of 0.15 ng mL?1 was obtained for Pb(ΙΙ). The selectivity of the proposed electrode for Pb(ΙΙ) ions in the presence of some cations was also examined. The practical application of the proposed modified electrode was evaluated by the determination of Pb(ΙΙ) ions in human hair and water samples. The results were satisfactory for the spiked samples.  相似文献   

11.
ABSTRACT

A simple, highly sensitive voltammetric method for the determination of urapidil at poly(sodium4-styrenesulfonate) functionalized graphene-modified electrode (PSS-Gr/GCE) was described. Based on the PSS-Gr composites-modified glassy carbon electrode as a simple voltammetric sensor, it exhibited good conductivity and high sensitivity to urapidil. Under the optimize condition, a good linear relationship was obtained between peak currents and urapidil concentrations in the wider range of 2.0 × 10?9–8.0 × 10?8 mol L?1 and 2.0 × 10?7–2.0 × 10?5 mol L?1 with detection limit of 8 × 10?10 mol L?1 (S/N = 3). Based on the high sensitivity and good selectivity of the proposed electrode, the proposed method could apply to the detect of urapidil in urapidil sustained release tablets with satisfactory results.  相似文献   

12.
Su PG  Sun YL  Lin CC 《Talanta》2006,69(4):946-951
A novel ceramic nanowires of TiO2 and poly(2-acrylamido-2-methylpropane sulfonate) (TiO2 NWs/PAMPS) composite material films coated on quartz crystal microbalance (QCM) was prepared as a low humidity sensor. The 50 wt.% of TiO2 NWs/PAMPS composite material films showed excellent sensitivity (2.63 −ΔHz/Δppmv) at 31.5 ppmv), linearity (R2 = 0.9959) and acceptable response time (64 s at 34.6 ppmv). The low humidity sensing mechanism was discussed in terms of surface texture and nanostructured morphology of the composite materials. Moreover, the adsorption dynamic analysis, molecular mechanics calculation (association constant), was used to elucidate the effect of adding 50 wt.% TiO2 NWs into PAMPS in the increased sensitivity of low humidity sensing.  相似文献   

13.
Despite the outstanding properties of hyperbranched polyglycerols such as biocompatibility and multifunctionality, enough attention has not been paid to the synthesis of their functional copolymers. This problem has limited the structural diversity of hyperbranched polyglycerols and hampers further developments and their practical usage. In this work, butyrolactone segments were incorporated into the backbone of polyglycerols by one‐pot ring‐opening copolymerization of a mixture of glycidol and γ‐butyrolactone in the presence of tin(II) 2‐ethylhexanoate. Poly(glycerol‐oligoγ‐butyrolactone)s were then crosslinked by 2,5‐thiophenediylbisboronic acid to obtain polymeric nanonetworks with 140 nm average size. Afterwards, the gold electrode was modified by the polymeric nano‐networks, and it was used for the determination of glucose, glycated hemoglobin, and Escherichia coli in phosphate buffer solution (pH = 9.0) through cyclic voltammetry and impedance spectroscopic. Taking advantage of the straightforward synthesis, cheap precursors and multifunctionality of poly(glycerol‐oligoγ‐butyrolactone)s, they could be used for real‐time sensing of a wide range of biosystems. © 2019 Wiley Periodicals, Inc. J. Polym. Sci., Part A: Polym. Chem. 2019, 57, 1430–1439  相似文献   

14.
A sensitive and efficient electroanalytical method for trace determination of cadmium(II) was developed using hybrid material-modified carbon paste electrodes. The hybrid materials were obtained by modifying the commercial bentonite (BC) and locally collected clay (LC) using the hexadecyltrimethylammonium bromide (HDTMA) as to obtain the organo-modified clay samples (BH and LCH). Moreover, the local clay was pillared with aluminium and modified with the HDTMA (LCAH). The carbon paste electrode was modified with the BC/BCH/LC/LCH/LCAH hybrid materials. Cyclic voltammetric analytical data showed that the modified electrodes were possessed a characteristic reversible behaviour of Cd(II) in aqueous media. Moreover, a significant increase in cathodic or anodic current was obtained using the modified electrodes, BCH, LCH and LCAH. The electroactive surface area of modified electrodes was increased significantly compared to the pristine clay-modified carbon paste electrodes. The response of the modified electrode was not affected significantly varying the pH within the pH region 2.0–10.0. Fairly, a good linearity between the anodic current and concentration of Cd(II) (5.0–40 μg/L) was achieved using the modified electrodes (BCH, LCH and LCAH). The presence of different cations and anions as coexisting ions were studied in order to simulate the real water matrix measurements. Additionally, the real matrix analysis was simulated using the Cd(II) spiked tap water, which showed a good linearity between the concentration of Cd(II) and anodic current.  相似文献   

15.
This study used square-wave voltammetry and cyclic voltammetry to investigate the electrochemical oxidation of Thioctic Acid (TA) on a Carbon Paste Electrode (CPE) modified with copper-cobalt nanostructures and poly (1,5-Diaminonaphthalene). The voltammetric sensor was sensitive to the oxidation of TA. In addition, we optimized the effects of multiple cycles of deposition of Cu-Co nanostructures, and electro-polymerization of monomer 1,5-DAN, scan rate, and pH. The sensor showed good identification capabilities for TA. The linear responses obtained ranged from 0.6 μM to 150 μM with a detection limit of 0.48 μM for the modified CPE. The adsorption process controlled the oxidation of TA. We used the proposed sensor and method to determine TA in real samples.  相似文献   

16.
17.
《Comptes Rendus Chimie》2014,17(1):62-68
A manganese complex of meso-tetrakis(p-hydroxyphenyl)porphyrin immobilized onto functionalized multi-wall carbon nanotubes has been synthesized and characterized. The catalytic activity of this heterogeneous catalyst was investigated in the oxidation of various olefins with hydrogen peroxide under ultrasonic irradiation. The role of the stoichiometric amounts of acetic anhydride/or acetic acid as an activator that introduces in situ peracetic acid is discussed. This heterogeneous catalyst was highly reusable in the oxidation reactions and reused several times without significant loss of its catalytic activity.  相似文献   

18.
A multi‐residue method has been developed and validated to determine 46 pesticides in spinach using liquid chromatography tandem mass spectrometry. The method is based on modified quick, easy, cheap, effective, rugged, and safe sample preparation, where high‐surface‐area graphitized carbon black was used first as sorbent material in the dispersive solid‐phase extraction. The method was compared with the quick, easy, cheap, effective, rugged, and safe method. The morphology, surface area, pore size, and pore volume of the sorbent was determined. The results obtained show that the sorbent consists of high surface area (233 m2/g) and large pore volume (1.5 cm3/g). The calibration curve correlation coefficient (R2) of the method was at least 0.99. The average recoveries ranged from 74 to 116%, and limits of detection and quantification from 0.0001 to 0.002 mg/kg and from 0.0002 to 0.005 mg/kg, respectively. Using the method, the pesticides exhibited low matrix effect (< 20%), except for nicosulfuron (29.86%), methomyl (26.77%), and flufenoxuron (24.65%). The method showed better potential to remove pigments than the quick, easy, cheap, effective, rugged, and safe method. It is demonstrated that the proposed method could be useful alternative for sample preparation of spinach and other matrices in future.  相似文献   

19.
The operational characteristics of a novel poly(tetrafluoroethylene) (PTFE) bead material, granular Algoflon®, used for separation and preconcentration of metal ions via adsorption of on-line generated non-charged metal complexes, were evaluated in a sequential injection (SI) system furnished with an external packed column and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used material, Aldrich PTFE, which had demonstrated that PTFE was the most promising for solid-state pretreatments. By comparing the two materials, the Algoflon® beads exhibited much higher sensitivity (1.6107 μg l−1 versus 0.2956 μg l−1 per integrated absorbance (s)), and better retention efficiency (82% versus 74%) and enrichment factor (20.8 versus 17.2), although a slightly smaller linear dynamic range (0.05-0.25 μg l−1 versus 0.05-1.00 μg l−1). Moreover, no flow resistance was encountered under the experimental conditions used. The results obtained on three standard reference materials were in good agreement with the certified values.  相似文献   