首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Prussian blue (PB) is an electrochromic material, which can be used as a signal transducer in the formation of optical urea biosensors. The previous researches in electrochromic properties of PB demonstrated the optical PB response to ammonium ions, which occurs when ammonium ions are interacting with PB layer at a constant 0.2 V vs Ag|AgCl|KClsat potential. In this work PB optical dependence on ammonium ions concentration was applied in the formation of electrochromic urea biosensor. Biosensor was formed by modifying the optically transparent indium tin oxide (ITO) coated glass electrode (glass/ITO) with Prussian blue layer and immobilizing urease (glass/ITO/PB‐urease). Calibration curve showed the linear dependency (R2=0.995) between the change of maximal absorbance (ΔA) and urea concentration in concentration range varying from 3 mM to 30 mM. The highest sensitivity (4 ΔA M?1) of glass/ITO/PB‐urease biosensor is in the concentration range from 7 mM to 30 mM. It was determined that working principle of the glass/ITO/PB‐urease biosensor is not related to pH changes occurring during enzymatic hydrolysis of urea.  相似文献   

2.
Herein, we reported for the first time that gold nanoparticles-catalyzed 3,3′,5,5′-tetramethylbenzidine-H2O2 system can serve as an ultrasensitive colorimetric pH indicator. Gold nanoparticles acted as a catalyst and imitated the function of horseradish peroxidase. The absorbance at 450 nm of the yellow-color product in the catalytic reaction exhibited a linear fashion over the pH range of 6.40–6.60. On the basis of this property, we constructed a novel sensing platform for the determination of urea, urease, and urease inhibitor. The limit of detection for urea and urease was 5 μM and 1.8 U/L, respectively. The half-maximal inhibition value IC50 of acetohydroxamic acid was found to be 0.05 mM. Urea in human urine and urease in soil were detected with satisfied results.  相似文献   

3.
A simple optical fibre biosensor based on immobilised enzyme for monitoring of trace heavy metal ions has been developed. The biosensor recognition system was designed based on the inhibition of urease activity, where the urease is immobilised on ultrabind membrane. The studies of inhibition by the heavy metal ions Hg(II), Ag(I), Cu(II), Ni(II), Zn(II), Co(II) and Pb(II) were performed using a fibre-optic biosensor configuration, where the pH change resulting from the bio-catalytic hydrolysis of urea was monitored at the wavelength 615 nm spectroscopically, using commercial pH indicator strip before and after the exposure to the heavy metal ions. The immobilised urease was regenerated by l-cysteine. The linear response range between 1×10-9–1×10-5 M and the limit of detection 1×10-9 M (0.2 g/L) for Hg(II) ions was achieved by employing the flow method. The optimisation of experimental parameters, including flow method, is also discussed.  相似文献   

4.
Different modifications of the zeolites Na+‐Beta and LTA were applied for improving the working characteristics of a urea biosensor. The bioselective membrane of the biosensor was based on urease and different zeolites co‐immobilized with bovine serum albumin on the surface of a pH‐FET. It was shown that the biosensors modified with the zeolites H+‐Beta30 and H+‐Beta50 are characterized by increased sensitivity to urea. The influence of the zeolite concentration on the sensitivity of the biosensors was studied. The optimal concentration of the zeolites H+‐Beta30 and H+‐Beta50 in the bioselective membrane was 15 %. Different variants of co‐immobilization of urease and zeolite H+‐Beta30 were studied and the optimal method was selected. Thus, a general conclusion is that the urea biosensor sensitivity can be improved using zeolite H+‐Beta30 for urease immobilization in the bioselective membrane.  相似文献   

5.
In this work, urea detection techniques based on the pH sensitivity of CdSe/ZnS QDs were developed using three types of sol-gel membranes: a QD-entrapped membrane, urease-immobilized membrane and double layer consisting of a QD-entrapped membrane and urease-immobilized membrane. The surface morphology of the sol-gel membranes deposited on the wells in a 24-well microtiter plate was investigated. The linear detection range of urea was in the range of 0-10 mM with the three types of sol-gel membranes. The urea detection technique based on the double layer consisting of the QD-entrapped membrane and urease-immobilized membrane resulted in the highest sensitivity to urea due to the Michaelis-Menten kinetic parameters. That is, the Michaelis-Menten constant (Km =2.0745 mM) of the free urease in the QD-entrapped membrane was about 4-fold higher than that (Km =0.549 mM) of the immobilized urease in the urease-immobilized membrane and about 12-fold higher than that (Km =0.1698 mM) of the immobilized urease in the double layer. The good stability of the three sol-gel membranes for urea sensing over 2 months showed that the use of sol-gel membranes immobilized with QDs or an enzyme is suitable for biomedical and environmental applications.  相似文献   

6.
An improved urea enzyme electrode is applied for the determination of urea in blood samples. The electrode is based on the enzymatic hydrolysis of urea, and potentiometric detection of the ammonium ion produced. A silicone rubber-based nonactin ammonium ion-selective electrode serves as the sensor. The selectivity coefficients of this electrode were 6.5 for NH4+/K+; 750 for NH4+/Na+, and much higher for other cations. The reaction layer of the electrode was made of urease enzyme chemically immobilized on polyacrylic gel. The prepared gel was stable at 4° for over four months. The electrodes retained their activity for over one month. A three-electrode system, which allowed dilution to a constant interference level, was applied to avoid interfering effects in blood samples. Analyses of blood sera showed good agreement with a standard spectrophotometric method. Routine clinical assays of blood urea are feasible.  相似文献   

7.
Capillary ion electrophoresis–capacitively coupled contactless conductivity detection (CIE-C4D) with a polyvinyl alcohol chemically coated capillary (PVA capillary) was used to analyze inorganic cations (Na+, K+, NH4+, Mg2+, and Ca2+) commonly found in human saliva. The PVA capillary, which was made by our laboratory, minimized electro-osmotic flow in the wide pH range of the background electrolyte (BGE), and the PVA layer adsorbed to capillary wall did not affect the conductimetric background level. In this study, we determined an optimized BGE of 30 mM lactic acid/histidine plus 3 mM 18-crown-6 for the CIE-C4D system using the PVA capillary, which could simultaneously improve the separation of Mg2+ and Ca2+ from Na+ and that of K+ from NH4+. This system obtained highly reproducible separation of cations in human saliva samples within 8 min at 20 kV without deprotonation. The quantifiability of cations in human saliva samples on the CIE-C4D system was demonstrated through identification by ion chromatography with satisfactory results.  相似文献   

8.
Chang G  Tatsu Y  Goto T  Imaishi H  Morigaki K 《Talanta》2010,83(1):61-65
Optical biosensor arrays for rapidly determining the glucose concentrations in a large number of beverage and blood samples were developed by immobilizing glucose oxidase (GOD) on oxygen sensor layer. Glucose oxidase was first encapsulated in silica based gels through sol-gel approach and then immobilized on 96-well microarrays integrated with oxygen sensing film at the bottom. The oxygen sensing film was made of an organically modified silica film (ORMOSIL) doped with tris(4,7-diphenyl-1,10-phenanthroline) ruthenium dichloride (Ru(dpp)3Cl2). The oxidation reaction of glucose by glucose oxidase could be monitored through fluorescence intensity enhancement due to the oxygen consumption in the reaction. The luminescence changing rate evaluated by the dynamic transient method (DTM) was correlated with the glucose concentration with the wide linear range from 0.1 to 5.0 mM (Y = 13.28X − 0.128, R = 0.9968) and low detection limit (0.06 mM). The effects of pH and coexisting ions were systemically studied. The results showed that the optical biosensor arrays worked under a wide range of pH value, and normal interfering species such as Na+, K+, Cl, PO43−, and ascorbic acid did not cause apparent interference on the measurement. The activity of glucose oxidase was mostly retained even after 2-month storage, indicating their long-term stability.  相似文献   

9.
In this study, a novel, sensitive electrochemical enzyme-based biosensor for urea detection was presented. This biosensor combines a three-electrode system consisting of a classic Glassy Carbon Electrode (GCE) as the working electrode, a platinum counter electrode, and Ag/AgCl as the reference electrode. To construct this urea platform, a GCE was modified with a polyaniline (PANi) film. Then, bacterial urease from Proteus mirabilis was immobilized on the modified GCE (Pm-Urease-PANi-GCE). For the characterization of surface modification, Cyclic Voltammetry (CV) and Scanning Electron Microscope (SEM) were applied, while the Square Wave Voltammetry (SWV) technique was performed for urea detection. The main analytical characteristics of the Pm-Urease-PANi-GCE biosensor showed a good linear range from 0.1 to 10 mM of urea, a limit of detection (LOD) of 0.1 mM, a Michaelis-Menten Km of 0.23 mM, and a sensitivity value 46 μA/mM/cm2. This biosensor allows the detection of urea in solutions, and it could be improved for further medical, environmental, or engineering applications.  相似文献   

10.
In this research a novel osmium complex was used as electrocatalyst for electroreduction of oxygen and H2O2 in physiological pH solutions. Electroless deposition at a short period of time (60 s), was used for strong and irreversible adsorption of 1,4,8,12‐tetraazacyclotetradecane osmium(III) chloride (Os(III)LCl2) ClO4 onto single‐walled carbon nanotubes (SWCNTs) modified GC electrode. The modified electrode shows a pair of well defined and reversible redox couple, Os(IV)/Os(III) at wide pH range (1–8). The glucose biosensor was fabricated by covering a thin film of glucose oxidase onto CNTs/Os‐complex modified electrode. The biosensor can be used successfully for selective detection of glucose based on the decreasing of cathodic peak current of oxygen. The fabricated biosensor shows high sensitivity, 826.3 nA μM?1cm?2, low detection limit, 56 nM, fast response time <3 s and wide calibration range 1.0 μM–1.0 mM. The biosensor has been successfully applied to determination of glucose in human plasma. Because of relative low applied potential, the interference from electroactive existing species was minimized, which improved the selectivity of the biosensor. The apparent Michaelis‐Menten constant of GOx on the nanocomposite, 0.91 mM, exhibits excellent bioelectrocatalytic activity of immobilized enzyme toward glucose oxidation. Excellent electrochemical reversibility, high stability, technically simple and possibility of preparation at short period of time are of great advantages of this glucose biosensor.  相似文献   

11.
Different techniques have been used (physical adsorption, physically entrapped sandwich and microencapsulation) for the immobilization of urease enzyme in tetramethylorthosilicate (TMOS) derived sol-gel matrix on the sensing surface of glass-pH-electrode. No significant leaching of enzyme occurs from the microencapsulated and physically entrapped enzyme sandwich films. Potentiometric techniques have been used for the estimation of urea concentration in each instance. Various parameters of biosensor performance have been studied which indicates that microencapsulation technique is a better method of enzyme immobilization in sol-gel films derived from TMOS. The advantage of microencapsulated biosensor over others include higher sensitivity (dpH/dp(C) = 2.4), lower detection limit of 52 μg mL−1, larger linear range (0.01-30 mM) of urea determination and reasonably long-term stability of about 25 days with 80% response signal.  相似文献   

12.
Nickel oxide nanoparticle (NiO?NP) and polypyrrole (PPy) composite were deposited on a Pt electrode for fabrication of a urea biosensor. To develop the sensor, a thin film of PPy?NiO composite was deposited on a Pt substrate that serves as a matrix for the immobilization of enzyme. Urease was immobilized on the surface of Pt/PPy?NiO by a physical adsorption. The response of the fabricated electrode (Pt/PPy?NiO/Urs) towards urea was analyzed by chronoamperometry and cyclic voltammetry (CV) techniques. Electrochemical response of the bio‐electrode was significantly enhanced. This is due to electron transfer between Ni2+ and Ni3+ as the electro‐catalytic group and the reaction between polypyrrole and the urease‐liberated ammonium. The fabricated electrode showed reliable and demonstrated perfectly linear response (0.7–26.7 mM of urea concentration, R2= 0.993), with high sensitivity (0.153 mA mM?1 cm?2), low detection of limit (1.6 μM), long stability (10 weeks), and low response time (~5 s). The developed biosensor was highly selective and obtained data were repeatable and reproduced using PPy‐NiO composite loaded with immobilized urease as urea biosensors.  相似文献   

13.
A biosensor for the determination of urea in human serum was fabricated using a combination of inkjet printed polyaniline nanoparticles and inkjet printed urease enzyme deposited sequentially onto screen-printed carbon paste electrodes. Chronocoulometry was used to measure the decomposition of urea via the doping of ammonium at the polyaniline-modified electrode surface at -0.3 V vs. Ag/AgCl. Ammonium could be measured in the range from 0.1 to 100 mM. Urea could be measured by the sensor in the range of 2-12 mM (r(2)=0.98). The enzyme biosensor was correlated against a spectrophotometric assay for urea in 15 normal human serum samples which yielded a correlation coefficient of 0.85. Bland-Altman plots showed that in the range of 5.8-6.6 mM urea, the developed sensor had an average positive experimental bias of 0.12 mM (<2% RSD) over the reference method.  相似文献   

14.
We have developed a lactate biosensor based on a bionanocomposite (BNC) composed of titanium dioxide nanoparticles (TiO2-NPs), photocatalytically reduced graphene, and lactate oxidase. Graphene oxide was photochemically reduced (without using any chemical reagents) in the presence of TiO2-NPs to give graphene nanosheets that were characterized by atomic force microscopy, Raman and X-ray photoelectron spectroscopy. The results show the nanosheets to possess few oxygen functionalities only and to be decorated with TiO2-NPs. These nanosheets typically are at least 1 μm long and have a thickness of 4.2 nm. A BNC was obtained by mixing lactate oxidase with the nanosheets and immobilized on the surface of a glassy carbon electrode. The resulting biosensor was applied to the determination of lactate. Compared to a sensor without TiO2-NPs, the sensor exhibits higher sensitivity (6.0 μA mM?1), a better detection limit (0.6 μM), a wider linear response (2.0 μM to 0.40 mM), and better reproducibility (3.2 %).
?  相似文献   

15.
A simple, sensitive and effective method to detect glucose in ultra-low ionic strength solution containing citrate-capped silver nanoparticles (CCAgNPs) was developed by monitoring the change of solution conductance. Glucose was catalyzed into gluconic acid firstly by glucose oxidase in an O2-saturated solution accompanied by the reduction of O2 into hydrogen peroxide (H2O2). Then, CCAgNPs was oxidized by H2O2 into Ag+ and the capping regent of citrate was released at the same time. All these resulted Ag+, gluconic acid and the released citrate would contribute to the increase of solution ionic strength together, leading to a detectable increase of solution conductance. And a novel conductance glucose biosensor was developed with a routine linear range of 0.06–4.0 mM and a suitable detection limit of 18.0 μM. The novel glucose biosensor was further applied in energy drink sample and proven to be suitable for practical system with low ionic strength. The proposed conductance biosensor achieved a significant breakthrough of glucose detection in ultra-low ionic strength media.  相似文献   

16.
A label-free electrochemical biosensor for detecting DNA hybridisation was developed by monitoring the change in the voltammetric activity of ferrocenecarboxylic acid at the biosensor–solution interface. The biosensor was constructed by initially immobilising on a glassy carbon electrode an anchoring layer consisting of chitosan, carboxyl group functionalised carbon nanofibres and glutaraldehye. Chitosan acted as an adhering agent and carbon nanofibres were strategically used to provide a large surface area with binding points for DNA immobilisation, while glutaraldehye was a linker for DNA probes on the electrode surface. Based on a two-factorial design, cyclic voltammetry of [Fe(CN)6]3−/4− was performed to optimise the composition of the anchoring layer. Next, a 17-base pair DNA probe was attached to the anchoring layer, followed by its complementary target. Zr(IV) ion, known to exhibit affinity for oxygen-containing electroactive markers, for example, ferrocenecarboxylic acid, was then coordinated in the DNA duplex. In this way, ferrocenecarboxylic acid was attracted towards the biosensor for oxidation. A change in the voltammetric oxidation current of ferrocenecarboxylic acid pre- and post-hybridisation was used to provide an indication of hybridisation. A linear dynamic range between 0.5 and 40 nM and a detection limit of 88 pM of DNA target were then achieved. In addition, the biosensor exhibited good selectivity, repeatability and stability for the determination of DNA sequences.  相似文献   

17.
A biosensor system for simultaneous determination of creatinine and urea in blood serum and dialysate samples was developed. It consisted of creatinine and urea biosensors based on a potentiometric transducers with two identical pH‐sensitive field‐effect transistors. In creatinine biosensor, creatinine deiminase immobilized via photopolymerization in PVA/SbQ polymer on one transistor served as a biorecognition element, while bovine serum albumin in PVA/SbQ polymer placed on the second transistor was used for reference. The urea biosensor was created in the same way but recombinant urease was used instead of creatinine deiminase. The linear ranges of creatinine and urea measurement were 0.02–2 mM and 0.5–15 mM, correspondingly, which allowed simultaneous determination of the metabolites. Response time of the biosensor system was 2–3 min; RSD of responses did not exceeded 5 %. The biosensors demonstrated absence of non‐selective response towards components of blood dialysate and serum. Urea and creatinine concentrations were determined in 20 samples of blood dialysate and serum. The results correlated well with traditional methods of analysis. Creatinine and urea biosensors were stable during five months of storage (during this time the responses decreased by about 10 %). The proposed biosensor system can be effectively used for analysis of serum samples and for hemodialysis control.  相似文献   

18.
《Electroanalysis》2017,29(5):1267-1277
Graphite rod (GR) modified with electrochemicaly deposited gold nanoparticles (AuNPs) and adsorbed glucose oxidase (GOx) was used in amperometric glucose biosensor design. Enzymatic formation of polypyrrole (Ppy) on the surface of GOx/AuNPs/GR electrode was applied in order to improve analytical characteristics and stability of developed biosensor. The linear glucose detection range for Ppy/GOx/AuNPs/GR electrode was dependent on the duration of Ppy‐layer formation and the linear interval was extended up to 19.9 mmol L−1 after 21 h lasting synthesis of Ppy. The sensitivity of the developed biosensor was determined as 21.7 μA mM−1 cm−2, the limit of detection – 0.20 mmol L−1. Ppy/GOx/AuNPs/GR electrodes demonstrated advanced good stability (the t 1/2 was 9.8 days), quick detection of glucose (within 5 s) in the wide linear interval. Additionally, formed Ppy layer decreased the influence of electroactive species on the analytical signal. Developed biosensor is suitable for the determination of glucose in human serum samples.  相似文献   

19.
《Electroanalysis》2004,16(22):1891-1895
An ISFET based enzymatic biosensor was developed for the determination of urea. Immobilization of urease was accomplished by the use of liquid mixture which contained vinylpyrrolidone, oligouretane metacrylate and oligocarbonate metacrylate and which can form a polymer under the influence of ultraviolet. The biosensor has the following characteristics: the linear field of responses is in the range of 0.05–20 mM, curve slope – 38 mV/pC, and response time 5–10 min. The increase of the temperature from 28 to 41 °C leads to 15% increase in the intensity of the response of the biosensor. The maximum response is observed at pH 6.0–6.5. At the increase of the NaCl concentration in solution up to 300 mM the biosensor response drops off and achieves half of its initial level. NH4Cl causes a stronger inhibition of enzyme activity comparing to NaCl. The results obtained with the developed biosensor correlate with the data of standard calorimetric methods. The intensity of the biosensor response decreases gradually during 40 days up to 80% of the initial level. The biosensors prepared with a fresh membrane or membrane preserved during 46 days at 2 °C gave similar responses in solution with an equal concentration of a substrate. It is concluded that the developed enzymatic biosensor is perspective for its clinical application for the determination of urea in blood and that the proposed method to prepare a selective biological membrane may be in a simple way included in integral technology of the semiconductor transducer manufacturing.  相似文献   

20.
《Electroanalysis》2004,16(23):1992-1998
A carbon nanotubes‐based amperometric cholesterol biosensor has been fabricated through layer‐by‐layer (LBL) deposition of a cationic polyelectrolyte (PDDA, poly(diallyldimethylammonium chloride)) and cholesterol oxidase (ChOx) on multi‐walled carbon nanotubes (MWNTs)‐modified gold electrode, followed by electrochemical generation of a nonconducting poly(o‐phenylenediamine) (PPD) film as the protective coating. Electrochemical impedance measurements have shown that PDDA/ChOx multilayer film could be formed uniformly on MWNTs‐modified gold electrode. Due to the strong electrocatalytic properties of MWNTs toward H2O2 and the low permeability of PPD film for electroacitve species, such as ascorbic acid, uric acid and acetaminophen, the biosensor has shown high sensitivity and good anti‐interferent ability in the detection of cholesterol. The effect of the pH value of the detection solution on the response of the biosensor was also investigated. A linear range up to 6.0 mM has been observed for the biosensor with a detection limit of 0.2 mM. The apparent Michaelis‐Menten constant and the maximum response current density were calculated to be 7.17 mM and 7.32 μA cm?2, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏